| 1 | THERMAL INSULATION WORKS PERTAINING TO BOILER AREA OF 250 MW, UNIT-7, PTPS, PANIPAT as per scope of work of e-NIT |
| 2 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Coal Feed Pipe, Temp. upto 150oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness and insulation thickness 60 mm. |
| 3 | Providing insulation work of Boiler Area of 250 MW, Unit-7on PRDS drain line & tracing line, Temp. upto 250oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness and insulation thickness 60 mm |
| 4 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Inlet & Outlet , Temp. upto 150oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness and insulation thickness 60 mm |
| 5 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Flue Gas duct from Eco outlet to RAH inlet & Hot PA Duct , Temp. upto 350oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 60 mm and Flue Gas duct from RAH outlet to ESP inlet & ESP outlet to chimney , Temp. upto 150oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 60 mm |
| 6 | Providing insulation work of Boiler Area of 250 MW, Unit-7on PA/FD/ID Fan casing , Temp. upto 75oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness and insulation thickness 60 mm |
| 7 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Mixing Box & Mill Steam inerting line , Temp. upto 250oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness and insulation thickness 60 mm |
| 8 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Boiler Furnace , Temp. upto 400oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 120 mm |
| 9 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Central section & opening of APH , Temp. upto 350oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 120 mm |
| 10 | Providing insulation work of Boiler Area of 250 MW, Unit-7on CRH line , Temp. upto 350oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 150 mm |
| 11 | Providing insulation work of Boiler Area of 250 MW, Unit-7on PRDS charging line from CRH line , Temp. upto 350oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 150 mm |
| 12 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Coal Mill hot air box , Temp. upto 250oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 150 mm |
| 13 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Re-heater, Platen SH, Final SH, Headers inside the pent house without cladding , Temp. upto 540oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 150 mm |
| 14 | Providing insulation work of Boiler Area of 250 MW, Unit-7on PRDS charging line from MS line , Temp. upto 540oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 200 mm |
| 15 | Providing insulation work of Boiler Area of 250 MW, Unit-7on HRH line , Temp. upto 540oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 250 mm |
| 16 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Main Steam line , Temp. upto 540oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 250 mm |
| 17 | Providing insulation work of Boiler Area of 250 MW, Unit-7on Ring Header & Z panel , Temp. upto 350oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 250 mm |
| 18 | Providing insulation work of Boiler Area of 250 MW, Unit-7with Cladding only (Pressure Part & ESP) Temp. upto 400oC , with GI wire netting & Old Cladding to be used & insulation thickness 120 mm |
| 19 | Providing insulation work pertaining to Turbine Area of 250MW, Unit-7 on HP turbine module including adjoining area (including HP shaft sealing cover, elow etc.), Temp. max. 550oC , & insulation thickness max. 440 mm & as per actual in adjoining area, Cladding spray insulation |
| 20 | Providing insulation work pertaining to Turbine Area of 250MW, Unit-7 on MS and HRH Strainer & HP / IP Pipe lines , Temp. upto 540oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 250/300 mm |
| 21 | Providing insulation work pertaining to Turbine Area of 250MW, Unit-7 on BPE-1 & 2, MS & HRH Drain etc , Temp. upto 540oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 200 mm |
| 22 | Providing insulation work pertaining to Turbine Area of 250MW, Unit-7 on MAW 10, MAW 55, MAW-15 & BP 3,4,6,8 and steam piping etc , Temp. upto 350oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 100 mm |
| 23 | Providing insulation work pertaining to Turbine Area of 250MW, Unit-7 on Valve, piping & Dearator etc , Temp. upto 250oC , with GI wire netting & Cladding of AI. Sheet 0.56 mm thickness & insulation thickness 60 mm |
| 24 | Providing insulation work pertaining to Turbine Area of 250MW, Unit-7 with Cladding only of AI. Sheet 0.56 mm thickness |