Bids Are Invited For 60 Kva Avr Supply Of Indoor ,Servo Controlled Automatic Voltage Regulator Of 415Volts,3 Phase,50 Hz, 60 Kva Capacity Conforming To The Technical Specifications In Section Ii 1.00 Capacity Of Avr 60 Kva (Continuous) 1.1 Input Vol, Shivamogga-Karnataka

Ministry of Information and Broadcasting has published Bids Are Invited For 60 Kva Avr Supply Of Indoor ,Servo Controlled Automatic Voltage Regulator Of 415Volts,3 Phase,50 Hz, 60 Kva Capacity Conforming To The Technical Specifications In Section Ii 1.00 Capacity Of Avr 60 Kva (Continuous) 1.1 Input Vol. Submission Date for this Tender is 18-12-2024. Voltage Regulator Tenders in Shivamogga Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

46655892
Bids Are Invited For 60 Kva Avr Supply Of Indoor ,Servo Controlled Automatic Voltage Regulator Of 415Volts,3 Phase,50 Hz, 60 Kva Capacity Conforming To The Technical Specifications In Section Ii 1.00 Capacity Of Avr 60 Kva (Continuous) 1.1 Input Vol
Open Tender
Indian
Karnataka
Shivamogga
18-12-2024

Tender Details

Bids Are Invited For 60 Kva Avr Supply of indoor ,servo controlled automatic voltage regulator of 415Volts,3 Phase,50 Hz, 60 KVA capacity conforming to the technical specifications in Section II 1.00 Capacity of AVR 60 KVA (continuous) 1.1 Input Voltage 360 V to 460 V Three Phase, 50 Hz, 4 wire 1.2 Output Voltage 415 V +/-1% adjustable 5% for 3 phase 1.3 Voltage regulation plus/minus 1% from no load to full load 1.4 Frequency 47-60 Hz 1.5 Duty Cycle Continous 1.6 Distortion AVR should not introduce any output distortion (to be shown on dual trace CRO) 1.7 AVR Type Indoor, free floor standing, servo controlled with individual phase sensing and control for regulating unbalance incoming voltage and suitable for unbalanced loads. The unbalance in load can be of the order of 50% of rated load. The output voltage stability with this unbalance (upto 50%) should be within +/- 5% of the Nominal voltage. It should be possible for independent voltage sensing and regulation in each phase. 1.8 No load current Shall not exceed 5% of the rated output current. 1.9 Type of Servo Micro Controller based True RMS sensing and correction 1.1 Servo motor drive Triac based AC step synchronous motor 1.11 Waveform distortion NIL 1.12 Effect of load power factor NIL 1.13 Overloading Upto 20% more rated current for 30 minutes 1.14 Speed of correction > 25 V/sec 1.15 Efficency Better than 95% 1.16 Transformer Winding Electrolytic prime grade copper of 99.9% certificate to be provided during inspection 1.17 Lamination of Transformer & Dimmerstat M4 Grade - CRGO 0.27 mm thickness Watt loss/Kg 1.2W 1298352/2024/AIR Proj, Zonal Office (SZ)ents of the AVR shall be capable of with standing high voltage of 2.5 KV at the rated frequency for 1 minute applied between line parts and body. 1.19 Insulation Class As per IS amended up to date 1.20 Mode of operation Automatic and Manual mode selection 1.21 Type of cooling Air cooled 1.22 Output protection with Audio Visual Alarms Short circuit, single phase preventor, over current/over load protection with earth fault protection, high cut and low cut feature so that the unit gives minimum output in case of output feedback failure. Over load and short circuit protection should be through MCCB of suitable rating of reputed make. The unit should have auto restoration feature after time delay in case of tripping due to over voltage. Both audio and visual alarms to be provided. 1.23 Operating Temperature AVR shall work satisfactorily under ambient temperature of 0-50 deg and relative humidity of 95% 1.24 Front panel Controls Auto/Manual selection Switch, Voltage Buck-Boost Switch, Voltmeter input/output phase wise selector switch, Ammeter phase to phase & phase to neutral wise selector switch. The switches are of reputed make. 1.25 Front panel displays True RMS Voltmeter & Ammeter preferably digital, indicating lamps on each phase, over-load indicator, high cut-low cut indicator,phase reversal/failure indicator. The indicators should be of LED type. 1.26 Rear panel terminals Separate heavy duty terminal blocks for input and output connections. 1.27 Time Delay switching An adjustable time delay device shall be provided so that the output is connected to load about 10 to 20 sec (adjustable) after the input is / switched on/restored after Power Supply failure or momentary interrurtion during which period the AVR output voltage will stabilize to the desired preset value. 1.28 No Load Losses at 415 V & 50 Hz 1% of the rated KVA 1.29 Max loss at full load current 3% of rated KVA 1.3 Designation Lables Suitable designation lables for all control & indicating lamps etc shall be engraved on the panel and shall be distinctly visible. Total Quantity : 2

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document