}

Tender For Supply Of Smps Based Ips For Lc Gate, jaipur-Rajasthan

North Western Railway has published Tender For Supply Of Smps Based Ips For Lc Gate. Submission Date for this Tender is 06-01-2025. Railway Ancillaries Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

46595029
Tender For Supply Of Smps Based Ips For Lc Gate
Open Tender
Indian
Rajasthan
Jaipur
06-01-2025

Tender Details

Supply Of Supply Of Smps Based Ips For Lc Gatesupply Of Smps Based Ips For Lc Gate,Supply Of Smps Based Ips System Suitable For Auto Hut/ Midsection Interlocked Lc Gate In Re Area And Conforming To Rdso Specn. No. Rdso/Spn/165/2023 Version 4.0 With Amendment-1, Along With Remote Indication Panel. The Total Number Of Supplies And Their Modules Rating/Capacity Of Each Type Of Supply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 2 V/300 Ah Lmla Batteries (55 Nos+5 Nos.) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenance Of Ips And Set Of Spare As Recommended/ Mentioned In Rdso Specn. No.Rdso/Spn/165/ 2023 Version 4.0 With Amendment-1. It Includes Supply Of Proper Hard Wood Stand For Keeping Batter Ies As Per Sample Approved By Engineer At Site. The Length Of Cables To Be Supplied With Each Ips Syst Em Will Be As (A) Cable From Ips System To Battery Bank - 25 Mtrs. (25 Sq Mm) (B) Cable From Ips Syste M To Asm Box - 35 Mtrs. (12 C X 1.5 Sq Mm). The Technical Specification Of These Above Said Cables Will Be As Per Rdsos Letter Sts/E/Ips/Genl Dated 03.04.18 Installation And Commissioning Is Not Required. ] , Supply Of Smps Based Ips System Suitable For Auto Hut/ Midsection Interlocked Lc Gate In Re Area And Conforming To Rdso Specn. No. Rdso/Spn/165/2023 Version 4.0 With Amendment-1, Along With Remote Indication Panel. The Total Number Of Supplies And Their Modules Rating/Capacity Of Each Type Of Supply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 2 V/300 Ah Lmla Batteries (55 Nos+5 Nos.) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenance Of Ips And Set Of Spare As Recommended/ Mentioned In Rdso Specn. No.Rdso/Spn/165/ 2023 Version 4.0 With Amendment-1. It Includes Supply Of Proper Hard Wood Stand For Keeping Batter Ies As Per Sample Approved By Engineer At Site. The Length Of Cables To Be Supplied With Each Ips Syst Em Will Be As (A) Cable From Ips System To Battery Bank - 25 Mtrs. (25 Sq Mm) (B) Cable From Ips Syste M To Asm Box - 35 Mtrs. (12 C X 1.5 Sq Mm). The Technical Specification Of These Above Said Cables Will Be As Per Rdsos Letter Sts/E/Ips/Genl Dated 03.04.18. Installation And Commissioning Is Not Required . ] , Supply Of Smps Based Ips System Suitable For Auto Hut/ Midsection Interlocked Lc Gate In Re Area And Conforming To Rdso Specn. No. Rdso/Spn/165/2023 Version 4.0 With Amendment-1, Along With Remote Indication Panel. The Total Number Of Supplies And Their Modules Rating/Capacity Of Each Type Of Supply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 2 V/300 Ah Lmla Batteries (55 Nos+5 Nos.) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenance Of Ips And Set Of Spare As Recommended/ Mentioned In Rdso Specn. No.Rdso/Spn/165/ 2023 Version 4.0 With Amendment-1. It Includes Supply Of Proper Hard Wood Stand For Keeping Batter Ies As Per Sample Approved By Engineer At Site. The Length Of Cables To Be Supplied With Each Ips Syst Em Will Be As (A) Cable From Ips System To Battery Bank - 25 Mtrs. (25 Sq Mm) (B) Cable From Ips Syste M To Asm Box - 35 Mtrs. (12 C X 1.5 Sq). The Technical Specification Of These Above Said Cables Will Be As Per Rdsos Letter Sts/E/Ips/Genl Dated 03.04.18. Installation And Commissioning Is Not Required. ] , Supply Of Smps Based Ips System Suitable For Auto Hut/ Midsection Interlocked Lc Gate In Re Area And Conforming To Rdso Specn. No. Rdso/Spn/165/2023 Version 4.0 With Amendment-1, Along With Remote Indication Panel. The Total Number Of Supplies And Their Modules Rating/Capacity Of Each Type Of Supply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 2 V/300 Ah Lmla Batteries (55 Nos+5 Nos.) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenance Of Ips And Set Of Spare As Recommended/ Mentioned In Rdso Specn. No.Rdso/Spn/165/ 2023 Version 4.0 With Amendment-1. It Includes Supply Of Proper Hard Wood Stand For Keeping Batter Ies As Per Sample Approved By Engineer At Site. The Length Of Cables To Be Supplied With Each Ips Syst Em Will Be As (A) Cable From Ips System To Battery Bank - 25 Mtrs. (25 Sq Mm) (B) Cable From Ips Syste M To Asm Box - 35 Mtrs. (12 C X 1.5 Sq Mm).The Technical Specification Of These Above Said Cables Will Be As Per Rdsos Letter Sts/E/Ips/Genl Dated 03.04.2018. Installation And Commissioning Is Not Requi Red. ] , Supply Of Smps Based Ips System Suitable For Auto Hut/ Midsection Interlocked Lc Gate In Re Area And Conforming To Rdso Spec. No.Rdso/ Spn/165/2023 Amendement-1, Along With Digital R Emote Indication Panel. The Total Number Of Supplies And Their Modules Rating/Capacity Of Each Type O F Supply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 110V/300 Ah Lmla Batteries (55 Nos+5 Nos.) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintena Nce Of Ips And Set Of Spare As Recommended/ Mentioned In Rdso Spec. No. No.Rdso/ Spn/165/2023 A Mendement-1. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Appro Ved By Engineer At Site. The Length Of Cables To Be Supplied With Each Ips System Will Be As : (A) Cable From Ips System To Battery Bank-25 Mtrs. (25 Sq Mm) (B) Cable From Ips System To Asm Box-35 Mtrs. ( 12 C X 1.5 Sq Mm Signalling Cable As Per Rdso Spec No 63/2014). Installation And Commissioning Is No T Required. ] , Supply Of Smps Based Ips System Suitable For Mid Section Lc Gate In Re Area And Confor Ming To Rdso Specification No: Rdso/Spn/165/2023 Version 4.0 With Amendment-1, Along With Remo Te Indication Panel. The Total Number Of Supplies And Their Modules Rating/Capacity Of Each Type Of Su Pply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 110V/300 Ah Lmla Bat Teries (55 Nos.+5 Nos.) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenanc E Of Ips And Set Of Spare As Recommended/ Mentioned In Rdso/Spn/165/2023 Version 4.0 With Amen Dment-1. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Approved B Y Engineer At Site. This Includes Transportation To Consignee Depot.Commissioning Of Integrated Power Supply System After Duly Filling Pre-Commissioning Check List By Rdso Approved Vendor And Railway Re Presentative Jointly.The Length Of Cables To Be Supplied With Each Ips System Will Be As (A) Cable From Ips System To Asm Box-70 Meters (Oem Shall Supply 12 Core X1.5 Sq.Mm Signalling Cable As Per Irs:S 63/2014) .(B) Cable From Ips To Battery Bank-30 Meters (25 Sq Mm). Installation Is Not Required. ] , Supply Of Smps Based Ips System Suitable For Mid Section Lc Gate In Re Area And Confor Ming To Rdso Specification No: Rdso/Spn/165/2023 Version 4.0 With Amendment-1, Along With Remo Te Indication Panel. The Total Number Of Supplies And Their Modules Rating/Capacity Of Each Type Of Su Pply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 110V/300 Ah Lmla Bat Teries (55 Nos.+5 Nos.) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenanc E Of Ips And Set Of Spare As Recommended/ Mentioned In Rdso/Spn/165/2023 Version 4.0 With Amen Dment-1. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Approved B Y Engineer At Site. This Includes Transportation To Consignee Depot.Commissioning Of Integrated Power Supply System After Duly Filling Pre-Commissioning Check List By Rdso Approved Vendor And Railway Re Presentative Jointly.The Length Of Cables To Be Supplied With Each Ips System Will Be As (A) Cable From Ips System To Asm Box -70 Meters (Oem Shall Supply 12 Core X1.5 Sq.Mm Signalling Cable As Per Irs:S 63/2014) .(B) Cable From Ips To Battery Bank-30 Meters (25 Sq Mm). Installation Is Not Required. ] , Supply Of Smps Based Ips System Suitable For Mid Section Lc Gate In Re Area And Confor Ming To Rdso Specification No: Rdso/Spn/165/2023 Version 4.0 With Amendment-1, Along With Remo Te Indication Panel. The Total Number Of Supplies And Their Modules Rating/Capacity Of Each Type Of Su Pply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 110V/300 Ah Lmla Bat Teries (55 Nos.+5 Nos.) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenanc E Of Ips And Set Of Spare As Recommended/ Mentioned In Rdso/Spn/165/2023 Version 4.0 With Amen Dment-1. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Approved B Y Engineer At Site. This Includes Transportation To Consignee Depot.Commissioning Of Integrated Power Supply System After Duly Filling Pre-Commissioning Check List By Rdso Approved Vendor And Railway Re Presentative Jointly.The Length Of Cables To Be Supplied With Each Ips System Will Be As (A) Cable From Ips System To Asm Box-70 Meters (Oem Shall Supply 12 Core X1.5 Sq.Mm Signalling Cable As Per Irs:S 63/2014) .(B) Cable From Ips To Battery Bank- 30 Meters (25 Sq Mm). Installation Is Not Required. ] , Supply Of Smps Based Ips System Suitable For Mid Section Lc Gate In Re Area And Confor Ming To Rdso Specification No: Rdso/Spn/165/2023 Version 4.0 With Amendment-1, Along With Remo Te Indication Panel. The Total Number Of Supplies And Their Modules Rating/Capacity Of Each Type Of Su Pply Shall Be As Per Attached Drawing Of Nwr. This Item Also Includes Supply Of 110V/300 Ah Lmla Bat Teries (55 Nos.+5 Nos.) It Covers Supply Of Tool Kit Containing All Type Of Tools Required For Maintenanc E Of Ips And Set Of Spare As Recommended/ Mentioned In Rdso/Spn/165/2023 Version 4.0 With Amen Dment-1. It Includes Supply Of Proper Hard Wood Stand For Keeping Batteries As Per Sample Approved B Y Engineer At Site. This Includes Transportation To Consignee Depot.Commissioning Of Integrated Power Supply System After Duly Filling Pre-Commissioning Check List By Rdso Approved Vendor And Railway Re Presentative Jointly.The Length Of Cables To Be Supplied With Each Ips System Will Be As (A) Cable From Ips System To Asm Box -70 Meters (Oem Shall Supply 12 Core X1.5 Sq.Mm Signalling Cable As Per Irs:S 63/2014) .(B) Cable From Ips To Battery Bank -30 Meters (25 Sq Mm). Installation Is Not Required. ]

Key Value

Document Fees
Refer document
EMD
INR 801120.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail