Electrical Work of Sub Divisional Offices of University Works Department, Jammu University Campus, Jammu- 1 Part-A (Sanctioned Schedule items) Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (WireMake ISI Marked Havells/Anchor /HPL /KEI/PolycabConduit Make - ISI Marked Anchor/High Power /AKG/Equivalent make of required specification to be approved by the Engineer In charge(Group ‘B’) 2 Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Wire Make ISI Marked Havells/Anchor/HPL/KEI/polycab/)Equivalent make of required specification to be approved by the Engineer In charge) i.2x1.5 Sq mm +1x1.5 Sq mm 3 ii.2x2.5 Sq mm + 1x2.5 Sq mm 4 iii.2x6 Sq mm + 1x6 Sq mm 5 iv.4x10 Sq mm + 2x6 Sq mm 6 Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required-ISI Marked Anchor/High Power /AKG/)Equivalent make of required specification to be approved by the Engineer In charge25 mm dia 7 Supplying and fixing 5 Amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.i.Single pole(Make Havells/Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) 8 Supply and Fixing following ratings, four pole, 415 volts, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as reqd. 63 Amp ratings (Make Havells/Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) 9 Supply and fixing of metal Box of following size on the surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 125mm x 60mm deep 10 Supply & fixing 15/16 amp piano type switch on the existing switch box or cover including connection as required. (Make:Anchor/Havells /HPL/Great White/ Equivalent make of required specification to be approved by the Engineer In charge) 11 Supply & fixing 6 pin 15/16 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/ HPL/Anchor/Great White/ Equivalent make of required specification to be approved by the Engineer In charge) 12 Supply & fixing 5/6 amp piano type switch on the existing switch box or cover including connection as required (Make :Havells/ HPL /Anchor /Great White/ Equivalent make of required specification to be approved by the Engineer In charge) 13 Supply & fixing 3 pin 5/6 amp socket outlet on the existing switch box or cover including connection as required(Make: Havells/ HPL /Anchor /Great white/ Equivalent make of required specification to be approved by the Engineer In charge) 14 Supplying and fixing following ways horizontal type three pole , and Neutral, sheet steel MCB Distribution Board 415V on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators. i.8 way(4+24),Double doorHavells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge 15 Supply & fixing two module stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. as required. (Make Havells/ HPL /Anchor /SSK/ C&S/Great White/ Equivalent make of required specification to be approved by the Engineer In charge) 16 Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL /Anchor / C&S/Great White/Equivalent make of required specification to be approved by the Engineer In charge) 17 Providing and fixing following rating and breaking capacity MCCB with Thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL/I.A/ Equivalent make of required specification to be approved by the Engineer In charge) 100 AMP 16K TP MCCB 18 200 AMP 36K FP MCCB 19 Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (WireMake ISI Marked Havells/HPL/Anchor/KEI/Polycab/ Equivalent make of required specification to be approved by the Engineer In charge)i.1x1.5 sqmm 20 Supply and Drawing of UTP 4 pair Cat 6 LAN Cable in the existing surface/recessed Steel/PVC conduit as required.1 run of cable 21 Part-B (Non Schedule items)Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/ Syska/Bajaj/ Greatwhite/ Philips/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)a.18 to 22watt, 220volts, 50Hz, 1200mm with rated input 140V to 270V,lumen efficiency 100 lumens/watt,driver efficiency 90%,starting voltage 90v,Thd<20,CRT>80, CT6500K,Life 25000 hours,surge 2.5 KV,P.F=0.95,made of high grade polycarbonate body LED batten complete. 22 Supply, installation, testing, commissioningof 1200 mm sweep ceiling fans complete with bladesBEE 1 to 3 star rated.(Make: Havells /Anchor/Orient/Crompton/USHA Equivalent make of required specification to be approved by the Engineer In charge) 23 Supply, installation, testing, commissioning of heavy duty 300 mmsweep exhaust fan.Make: ( Anchor/Havells/Bajaj /Crompton/ Equivalent make of required specification to be approved by the Engineer In charge) 24 Supply /Installation testing and commissioning of 450 mm sweep wall mounted fan including the electronic regulators and connection with testing and commissioning etc complete JobBEE 3 to 5 star rated energy efficient. Make: (Anchor /Bajaj /Crompton/ Havells ) 25 Supply & installation of CAT 6 2 module toll lessinformation outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations upto 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type complete as required.(Make Legrand/Delton/Havells/HPL/Anchor) 26 Providing/fixing 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissioning complete Job. (Havells/Anchor/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) 27 Supplying and fixing following ways horizontal typeMCB Distribution Board 415V on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators.i.4 way,For A.CHavells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge 28 Supply, testing and commissioning and Laying of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPECable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Gloster)Equivalent make of required specification to be approved by the Engineer In charge)3.5 core 35 sq mm armoured cable 29 Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, OUTGOINGSpace for1 No. 200AFP MCCBand Along withAl. Bus bar of equal cross section for power load/light/A.C load.Dimensions2x2’x1’6”