| 1 | Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 2 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 3 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 4 | Supply and erection of 150 mm dia. G.I. pipe (medium class) complete in all respect. |
| 5 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 6 | Supply and erection 33 KVisolator L and E as per DHBVN latest norm, and as perthe entire satisfaction of Engineer-in-charge of the work. |
| 7 | Supply and erection 33 KV pin insulator polymer type as per DHBVN latest norm, and as perthe entire satisfaction of Engineer-in-charge of the work. |
| 8 | Supply and erection 33 KV disc insulatorpolymer type as per DHBVN latest norm, and as perthe entire satisfaction of Engineer-in-charge of the work. |
| 9 | Supply and Erection of PCC pole as per DHBVN latest specification :- 11 mtr. long with working load of 400 kg PCC Pole. |
| 10 | Supply and Erection of PCC pole as per DHBVN latest specification :- 9 mtr. long with working load of 200 kg PCC Pole. |
| 11 | Supply and erection of TR-XLPE 33 KV HT aluminum size 300sqmm x 3 core, as per DHBVN approved GTP/drawings and approved vendors ISI mark laid in existing pipe/trenches/ surface with all labour and material required to complete the job in all respect upto the entire satisfaction of engineer in charge of the work. Make:- HAVELLS/CCI/PolyCab/KEI. |
| 12 | Supply and erection of 400 KVA 33-11/.433 KV off load oil filled transformers 3 phase 50 Hz, copper double wound, Oil Immersed, Naturally Cooled, Core type transformer conforming to IS : 1180 EEL as per latest IS-1180, amendment No.04. The foundation should be as per approved by manufacturer. The Makes and specification as per DHBVN latest Norm. |
| 13 | S/I/T/C of BIS Approved ISO 9001-2015 and ISO 14001 – 2015, ISI mark- 100 KVA (BIS LEVEL-2), 33-11/0.433 KV (Dual Ratio Type) 3 Phase, 50Hz, ONAN Cooled, Copper Wound (Outdoor type) Step down Distribution Transformer complete with first filling of ISI Marked transformer oil and all other fittings/accessories as per IS: 1180 Part 1 2014 Amnd. 4. The Makes and specification as per DHBVN latest Norms. 100KVA |
| 14 | Supply and Erection of 33KV, 36 KV switch without fuse units (LBS) consisting of a vaccum based load break switch cum isolator without fuses. The vaccum interrupter based load break switch cum isolator usable for switching and isolation and the fuse to protect the transformer/line against short circuit faults. The VI based SFU unit shall have three poles and three position (Open closed, earthed). It should be suitable to operate under on load and off load conditions. The mechanical and electrical interlocking system between the VI based load break switch and isolator with earth switch to be provided for operational/maintenance safety purpose. The total unit should be enclosed in CRCA cubical panel with IP 55 protection which is suitable for outdoor installation with complete in all respect upto the entire satisfaction of engineer in charge of the work. The foundation should be as per approved by manufacturer |
| 15 | Supply and erection LT Cables of various size armored cable as per IS specification. Make:- HAVELLS/CCI/PolyCab/KE. 630sqmm x 1 Core (A) |
| 16 | Providing and fixing of chemical earthing with 3 mtr. long 75 mm diaG.I pipe complete in all respect upto entire satisfaction of Engineer-in-charsge of the work. |
| 17 | Supply and erection of LT fuse unit suitable for 200/400 KVA transformer including cost of MS clamps Nut and Bolts etc. complete in all respect upto entire satisfaction of Engineer-in-charge of work. |
| 18 | S/E of ACSR conductor of various sizes single steel wire including jointing and binding with insulators at supports confirming to relevant ISS specifications :-ACSR Conductor 80sqmm |
| 19 | Supply and erection of PVC insulated ACSR Conductor with steel wire rope 20 sqmm complete in all respect. |
| 20 | Supply and erection of GSL wire 8 SWG complete in all respect as per ISS 280/1978 and IS 7806/1963 with latest amendment. |
| 21 | Supply and erection of LT stay set on 9.00 Mtr. long PCC pole 20mm dia 6` long GI stay set with 20mm 1 No.turn buckle, egg insulator large size of 110x110, elbow 20mm dia GI round welded firmly on MS angle of size 50x50x6 stay wire 7/8 SWG, GI nut and bolts 50x16mm stay clamp of size 50x6mm MS flat with primer and aluminium paint two Nos. 450mm long MS cross channel of size 75x40x6 with primer and 6 SWG GI wire complete in all respect as per drawing and as per DHBVN specification. |
| 22 | Supply and erection of LT guards made from GI wire 8 SWG and suitable for guard real and insulator and provided between neutral and earth wire complete in all respect as per DHBVNL specification and between two earth conductor for LT lines. complete in all respect upto entire satisfaction of Engineer-in-Charge of the work. |
| 23 | Supply and erection of MS Rod earthing set (HT/LT) 20 mm dia 2.5 mtr. long MS rod, 6 SWG thick conduct pipe 25 mm dia and 3 mtr. long enameled black paint and 6 SWG GI wire complete in all respect upto entire satisfaction of engineer in-charge of work. |
| 24 | S/E of MSD strap type II made of 375mm long MS flat of size 50x6mm suitable for LT shackle insulator large size (115x110mm) with red oxide two coat paint. |
| 25 | Supply and erection of LT shackle insulator brown glazed size 110mm x 90mm suitable for 415/240 volts confirming to IS 1545/1977 with latest amendment thereof. |
| 26 | S/E of L.T PVC spacer 4 way for proper space between phase conductors upto the entire satisfaction of engineer in charge of the work. |
| 27 | S/E of 70 Watt LED street light luminaire with multiple LED with highly efficient high power LED light with lens, pressure die cast aluminum housing, reflector and enclosed with toughened/ Polycarbonate glass, IP-66 level, having light efficacy 120 Lumens/watt up to the entire satisfaction of Engineer -in-charge of the work. (Make: Bajaj/Philips/LT/ Panasonic/Anchor) (With 3 years free replacement warranty at site including labour charges free of cost). |
| 28 | Supply and erection of G.I. Pipe bracket 1.00 Mtr. long made of 32mm dia G.I. pipe (B-Class) Jindal Hisar Make suitable for street light fitting including M.S. Clamps of M.S. Flat size 50x6mm, 06 Nos. Nut and Bolts of size 50x16mm and priming and painting complete in all respect upto the entire satisfaction of Engineer-in-Charge. |
| 29 | Supply and erection of PVC and sheathed Aluminum conductor cable 1 core 2.5sqmm 1100 volt grade in pipe etc. of suitable size excluding cost and erection of pipe complete in all respect upto the entire satisfaction of Engineer in charge of the work. |
| 30 | S/E of underground cable loose in existing pipe or trenches complete with necessary connections Make Havells. Plaza, Grandly, Ploycab300mm²x 3½ core armored. |
| 31 | S/E of underground cable loose in existing pipe or trenches complete with necessary connections Make Havells. Plaza, Grandly, Ploycab16sqmm x 4core armored. |
| 32 | Supply and erection of L.T. Aerial bunched cable of size 120 Sqmm X 4 core with messenger conductor of size 95 Sqmm single core including making of necessary connection of make Polycab/ Havell’s /KEI complete in all respect up to the entire satisfaction of Engineer-in-charge. (Rate without GST) |
| 33 | Providing HDPE Pipe 160 mm (PE-63) PN-4 for Trenchless horizontal boring 1.5 Mtr. below ground level of various sizes complete in all respect up-to the Entire satisfaction of Engineer-In-Charge. (Rate without GST) |
| 34 | Providing Trenchless horizontal boring 1.5 Mtr. below ground level including laying of HDPE pipe of size 160 mm (excluding the cost of pipe) complete in all respect up-to the Entire satisfaction of Engineer-In-Charge. (Rate without GST) |
| 35 | Supply and erection of 33KV, 630A, 25KA/1sec, Outdoor type, non extensible, manual, 3 way CVV type Ring Main unit (RMU) with termination kit suitable for 1RXCX400 sqmm (Make of termination kit-NKT/NEXANS/CELLPACK) as per approved GTP and drawings of DHBVN as per entire satisfaction of Engineer-in-charge. Make- ABB/Siemens/Schneider/Alstom |
| 36 | [13.27]Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 37 | [13.32]Providing and fixing bolts including nuts and washers complete. |
| 38 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA |
| 39 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole |
| 40 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE |
| 41 | [23.27.3]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof .The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 3. M.S. pedestal of size 750 mm wide , 1200 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 |
| 42 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. |
| 43 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. |
| 44 | [24.3.6.3]HT CABLE 6.3. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required :240 to 400 sqmm |
| 45 | [24.3.7.3]HT CABLE 7.3. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required : 240 to 400 sqmm |
| 46 | [24.3.8.2]HT CABLE 8.2. Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required : 185 to 300 sqmm |
| 47 | [24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 145/123 mm outer dia/ inner dia |
| 48 | [27.3]Plastering (12 mm thick) with cement mortar (1:3 ) on brick work in sub-structure as per MoRTandH Specifications 1300 & 2200 |
| 49 | [34.29.3]GI barbed wire fencing 3. Fencing With Welded Steel Wire Fabric 75 mm x 50 mm Providing 1.20 metre high fencing with angle iron posts 50 mm x 50 mm x 6 mm at 3 metre centre to centre with 0.40 metre embedded in M15 grade cement concrete, corner, end and every 10th post to be strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or 75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and bolts etc. complete in all respects.i) Adopt any one type of welded steel wire fabric 75 x 50 mm or 75 x 25 mm as per approved design.ii) The item of excavation and cement concrete in foundation shall be measured and paid separately |
| 50 | [4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 51 | [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 52 | [7.20.1]Brick work with common burnt clay modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) |