| 1 | S&F electric water heater, storage type, steel body, vertical type,of capacity 25 litres ,BEE approved 4/5 star rating with steel inner tank and heating element (Incoloy 800 glass coated) upto 2 KW complete with all accessories such as safety valve, thermostate cutout temprature (0ºC to 75ºC), water proof degree IPX4, Class of appliances -Class-I, rated pressure 0.8MPa, NRV, connection pipe etc. including anchor bolt fastners and making good surface as per existingcomplete all as specified and directed. Make:- Fabia of Havells/HSE-VAS-X of AO Smith/ Crest Plux of Bajaj |
| 2 | Supply, installation, testing & commissioningair cooled , split unit air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 1.5 TR, BEE5 Star rated with cooling and intelligent heating facility and Digital Inverter twin rotary including its fixing accessories with following specification: (i ) Rated cooling capacity: 18000 Btu/Hr (ii) Rated Current cooling : 7.8 Amp (iii) Rated heating capacity: 18000 Btu/Hr, (iv) Copressor type: High EER twin Rotary (v) Anti dust/Anti-bacterial Filter, (vi) Dehumidifier (vii) Refrigerant gas: R32, (viii) Operation: LCD Remote with self dignosis facility all as specified and directed. Note: The quoted rate shall deemed toinclude powder coated stand (bracket) for fixingoutdoor unit and cutting, chasing of wall/surface and making goodas per existing. |
| 3 | Supply, installation, testing & commissioningair cooled , split unit air conditioner electric driven AC 230 V, 50 Hz single phase of capacity 2.0 TR, BEE3/5 Star rated with cooling and intelligent heating facility and Digital Inverter twin rotary including its fixing accessories with following specification: (i ) Rated cooling capacity: 24000 Btu/Hr (ii) Rated Current cooling : 12.8 Amp (iii) Rated heating capacity: 24000 Btu/Hr, (iv) Copressor type: High EER twin Rotary (v) Anti dust/Anti-bacterial Filter, (vi) Dehumidifier (vii) Refrigerant gas: R32, (viii) noise level -33db (ix) Operation: LCD Remote with self dignosis facility all as specified and directed. Note: The quoted rate shall deemed toinclude powder coated stand (bracket) for fixingoutdoor unit and cutting, chasing of wall/surface and making goodas per existing. |
| 4 | Supply and installation, testing and commissioning of refrigerators, electric driven , capacity more than 195 Litres & upto210 Litres .BEE 5 star rated, suitable for operation on single phase, 240 volt, 50 Hz AC supply complete all as specified and directed . |
| 5 | Supply and installation, testing and commissioning of refrigerators, electric driven , capacity more than 310 Litres & upto to 360 Litres .BEE 5 star rated, suitable for operation on single phase, 240 volt, 50 Hz AC supply complete all as specified and directed . |
| 6 | Supply and installationof desert cooler with steel body having 450mm fan size (heavy duty) with Aluminium blades ISI Marked) electric driven (Single phase) operating switch three step having nominal air flow capacity 4000 CFM with wall thickness of sheet 1 mm and water tank & body pillar 1.5 mm thick sheet including prewired electric control panel with immersed pump of suitable size & capacity(ISI marked) pump and Fan motor including provn of floot valve of suitable sizecomplete all as specified and directed. |
| 7 | M&L for aluminium strip 25mmx3.15mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed |
| 8 | S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed |
| 9 | M&L for test points terminal block made ofgun metal orphosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos, 8mm dia, 25 mm long hexagonal head screw complete all as specified and directed . |
| 10 | S&F Galvanised iron strip 32 x 6 mm buried in ground complete all as specified and directed . |
| 11 | M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregates) as in supporting foundation of air termination rod complete all as specified and directed . |
| 12 | M & L for complete earthingwith galvanised mild steel earth plate electrode of size600x600x6mm thick burried directly in ground(in vertical) earth pit not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected togalvanised iron strip 32×6mm as earthing lead by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth strip protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSRPart-I and testing on completion all as specified and directed . |
| 13 | M&Lfor GI pipe 40 mm dia, light gradeforair termination rodfixed with clamps, nuts, bolts complete all as specified and directed . |
| 14 | Taking down chowkats or frames with shutter without taking off shutter from the frame exc 1.5 sqm & n. exe 4 sqm each including cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed . |
| 15 | S&F powder coated (Radiation lead line door) galvanised steel metal door frame and shutter,door frame of hollow section 105mmx57mm havingthickness not less than 1.6 mm andthickness of powder coated metal 1.20mm for door shutter& overall door thickness 46 mm. Hollow portionof door filled with rock wool/honeycomb and 2mm lead sheet in middle of the door complete all as specified and directed .Note : The radiation door shall be made from authorised manufacturers.The contractor shall submit the company profile & get itapproved from GEbefore purchasing . |
| 16 | S&F heavy duty stainless steel two ball bearing hinge of size 4\"x3\"x3mm, flat button, fixed with machine screws complete all as specified and directed |
| 17 | S&F anchor fastner CSK head type with GI plating size: 8mm x 80 mm with PVC sleeve (for door frame fixing in wall) fixed with gitties complete all as specified and directed |
| 18 | S&F heavy duty steel overhead rack and pinion door closerwith adjustable closing speed and adjustable latching actionwith mounting plate complete all as specified and directed |
| 19 | S&F heavy duty mortise dead lock with 70 mm cyllinder complete all as specified and directed |
| 20 | S&F heavy duty stainless steel\"D\" shape handle, 19 x 250 mmcomplete all as specified and directed |
| 21 | S&F lead line fix window powder coated galvanised steel metal frame ofhollow section 105mmx57mm & thicknes not less than 1.6 mm and lead glass thickness 10 mm, type ZF3, refracton index 1.7172, Density 4.46, Lead equivalent 3.10, Light Transmittane >85%, PB%-61.03% and X Ray Peak Voltage (KV) -150 complete all as specified and directed. Note : The radiation window shall be made from authorised manufacturers.The contractor shall submit the company profile & get itapproved from GEbefore purchasing |
| 22 | Taking down cement plaster from brick walls /ceiling or concerete of any description, raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material outside the premises complete all as specified and directed. |
| 23 | M&L for rendering 15mm thick in cement mortar 1:6 on brick/stone work and surface finished even and smooth without using extra cementcomplete all as specified anddirected . |
| 24 | M&L for preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over two coats of wall care putty of 1 to 2 mm thick each overone coat of primer complete all as specified and directed. |