| 1 | Taking down of ceiling fan of sweep 1200/1400mm of any make from any height of the building for maintenance and safety checking and fixing back in its original position including checking the internal wiring all as specified and as directed.Note:- (i) Defective/unserviceable minor accessories like rubber real, clamps, bolts, nuts, washers, safety pin etc will be measured and paid separately as supply only.Cost of labour element required for replacing the spares shall be deemed to be included in the unit rate quoted(ii) Rewinding /overhauling of fans will be measured seperately. |
| 2 | Supply only Rubber real bushes for ceiling fan of sweep 1200/1400mm |
| 3 | Supply only Safety pins with nuts and bolt with washers for ceiling fan |
| 4 | Mateiral and labour for Oiling and greasing of ceiling fan |
| 5 | Supply only blades of ceiling fan of any size |
| 6 | Supply only ceiling fan canopies |
| 7 | Preparation of old ceiling fan surfaces and applying spray painting to fan unit of sweep 1200 /1400mm (consisting of Fan motor, blades, canopy and downrod) with one coat of synthetic enamel paint of existing colour and marking the MES number on the fan motor with suitable paints all as directed. |
| 8 | Disconnection and removing unserviceable winding from ceiling fan motor of any sweep, cleaning the slots and rewinding same with suitable gauge super enamelled copper winding wire, insulating and heating properly including testing and commissioning complete all as directed. |
| 9 | S&F in repairfan bearing of suitable size for ceiling fan 1200mm /1400 mm sweep |
| 10 | S&F in repairfanbush of suitable size for ceiling fan 1200mm /1400 mm sweep |
| 11 | Servicingof pedastal fan of sweep 630mm from the location / MES store or shifting from site /MES store to work shop, disconnection and removing the unserviceable winding from the motor cleaning the slots and rewinding with suitable gauge super enamelled copper winding wire, insulating and heating properly testing and commissioning complete all as directed. |
| 12 | S&F in repair bearing of suitable size for pedastal fan of 630mm sweep |
| 13 | S&F in repairs bush of suitable size for pedastal fan of 630mm sweep |
| 14 | Preparation of old pedestal surfaces and spraypainting the fan of 630mm sweep with one coat of synthetic enamel paint of existing colour and marking the MES number with suitable paints complete all as directed. |
| 15 | Taking down of wall mounted fan of sweep 630/450/400mm of any make from any height of the building for maintenance and safety checking, refixing in original position, reconnecting the cables and testing complete all as directed.Note:- Defective/unserviceable minor accessories like rubber real, clamps, bolts, nuts, washers, safety pin etc will be measured and paid separately. |
| 16 | Disconnection and removing the unserviceable winding from the motor of wall mounted fan of sweep 630/450/400mm, cleaning the slots and rewinding the same with suitable gauge super enamelled copper winding wire, insulating and heating properly including testing and commissioning complete all as directed. |
| 17 | S&F in repairs bearing of suitable size for wall mounted fan of 630/450/400mm sweep. |
| 18 | S&F in repairs fan bush of suitable size for wall mounted fan of 630/450/400mm sweep |
| 19 | Taking down exhaust fan of sweep 450/300mm of any make from any height of the building for maintenance and safety checking, reconnecting in original position, reconnecting the cables and testing complete all as directed.Note:- Defective/unserviceable minor accessories like rubber real, clamps, bolts, nuts, washers, safety pin etc will be measured and paid separately. |
| 20 | Disconnection and removing the unserviceable winding from the motor of exhaust fan of sweep 450mm, cleaning the slots and rewinding the same with suitable gauge super enamelled copper winding wire, insulating and heating properly including testing and commissioning complete all as directed. |
| 21 | Disconnection and removing the unserviceable winding from the motor of exhaust fan of sweep 300mm, cleaning the slots and rewinding the same with suitable gauge super enamelled copper winding wire, insulating and heating properly including testing and commissioning complete all as directed. |
| 22 | S&F in repairsfan bearing of suitable size for exhaust fan of 450 mm sweep including greasing. |
| 23 | S&F in repairsfan bearing of suitable size for exhaust fan of 300 mm sweep including greasing. |
| 24 | S&F in repairs fan bush of suitable size for exhaust fan of 450 mm sweep |
| 25 | S&F in repairs fan bush of suitable size for exhaust fan of 300 mm sweep |
| 26 | Preparation of exhaust fan surface and applying spray painting for fan of 450mm sweep with one coat of synthetic enamel paint of existing colour and marking the MES number with suitable paints including required shifting complete all as directed. |
| 27 | Preparation of exhaust fan surface and applying spray painting for fan of 300 mm sweep with one coat of synthetic enamel paint of existing colour and marking the MES number with suitable paints including required shifting complete all as directed. |
| 28 | S&F in repairs 2.5 MFD capacity ceiling /exhaust fan condensors |
| 29 | S&F in repairs 4 MFD capacity ceiling /exhaust fan condensors |
| 30 | S & F in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as directed. |
| 31 | S&F in repairs metal louvers of suitable size for exhaust fan of 450 mm sweep |
| 32 | S&F in repairs metal louvers of suitable size for exhaust fan of 300 mm sweep |
| 33 | Supply and replacement of down rod of 2 to 3 feet length for ceiling fan with 15mm dia GI pipe medium grade, screwed and drilled with clamps rubber real, nut , bolts, and safty pin etc including painting complete all as directed. |
| 34 | Taking down carefully storagewater heater (geyser) 25 Ltr/35 ltr /50 Ltrfrom location after disconnecting electrical connection and water connections, shifting to work shop / MES Store, refixing in location after carrying out necessary repair works including provision of 3 core 7/20 copper cable and testing as specified and as directed.all as directed.Note:- Replacement of defective spares will be measured and paid under relevant itemsmentioned here in after separately. |
| 35 | Supply and fix in repairs, heating coil 1500 W including rubber washer/packing suitable for geyser. Make:- Theeta/Swarna (ISI Marked) |
| 36 | Supply and fix in repairs, heating coil 2000 W including rubber washer/packing suitable for geyser. Make:- Theeta/Swarna (ISI Marked) |
| 37 | Supply and fix in repairs, thermostat range of 30-80 degree suitable for geyser of 25/35/50 litres capacity |
| 38 | Brazing of inner copper tank of Geysers using good quality of copper electrode blow lamp welding process, brazing length not exc 10 cm complete all as directed. |
| 39 | Supply and fix in repairs, glass wool for insulator of Geysers any capacity and any make complete all as directed. |
| 40 | Supply and fix in repairs pressure relief valve CP brass suitable 15mm size |
| 41 | Supply and fix in repairs, Non return valve brass suitable 15mm size |
| 42 | Supply and fix in repairs, indicator lamp suitable for storagewater heater (geyser) 25 /35/50 Ltr |
| 43 | Preparation of water heater surfaces and spraypainting storagewater heater (geyser) of 25 /35 Ltr with one coat of synthetic enamel paint of existing colour and marking the MES number with suitable paints complete all as directed. |
| 44 | Preparation of water heater surfaces and spraypainting storagewater heater (geyser) of 50 Ltr with one coat of synthetic enamel paint of existing colour and marking the MES number with suitable paints complete all as directed. |
| 45 | Supply and fix in repairs, indoorassembly of any type made out of brass with inlet and out let and fixing plate complete including Gasket and nut blots as required at site for 25 Ltr capacity Geyser, any make complete all as directed. |
| 46 | Supply and fix in repairs, indoorassembly any type made out of brass with inlet and out let and fixing plate complete including Gasket and nut blots as required at site for 35/50 Ltr capacity Geyser, any make complete all as directed. |
| 47 | Supply and fix in repairs, PVC connecton 45 cm long both end brass nut suitable for hot / coldwater supply andscrew down 15mm GI pipe. |
| 48 | Material and labour, for grouting 4 Nos of M12 X100mm mild steel bolt in stone /brick masonary wall and making good the surface to match with the existing surface in cement mortar 1:4 suitable for hanging geysers, complete all as directed. |
| 49 | Over hauling & servicingthe solar water heater 100/200 ltr capacity by repair / replacing the spares and blocks in the solar cells removed by the acid cleaning and damaged solar cells to be replaced as directed.Note: Supply and replacement of spares will be measured and paid separately. |
| 50 | Supply and fix in repairs of Anode for solar water heater 100/200Ltr capacity |
| 51 | Supply and fix in repairs of solar gasket as per exisiting type. |
| 52 | Supply and fixing in repairs Bib taps suitable for bore dia of pipe 15 mm, fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule . |
| 53 | S&F in repairs Stop valves, 20 mm Bore dia of pipe, fancy type, chromium plated cast copper alloy, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. |
| 54 | Supply and fix in repairs of MCB SPN 32 amps 240 V 10 KA |
| 55 | Supply and fix in repairs of industrial type metal clad plug top & socket single pole and a natural link earth enclosure with MCB SP 20 Amp complete. |
| 56 | Disconnecting and removing unserviceable heat exchanger along with its connected items and provision of new solar water heater collector (heat exchanger) for 100 ltrs solar water heater of same size and capacity complete connecting up of connections complete all as specified and as directed. |
| 57 | Disconnecting and removing unserviceable heat exchanger along with its connected items andprovision of new solar water heater collector (heat exchanger) for 200 ltrs solar water heater of same size and capacity complete connecting up of connections complete all as specified and as directed. |
| 58 | Material and labour for, mild steel frame work for staging / frame work using standard sections like angle iron / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A / MS tube including necessary welding suitable for fixing 300 ltrs PVC water tank complete, including dismantling existing stage all as specified and directed. |
| 59 | Supply and fixsolar water tank of stainless steel alongwith puff insulation of capacity 100 Ltrs with electrical heating backup of 2 KW including taking down existing all as specified and as directed. |
| 60 | Supply and fixsolar water tank of stainless steel alongwith puff insulation of capacity 200 Ltrs with electrical heating backup of 2 KW including taking down existingall as specified and as directed. |
| 61 | M&L for point wiring with 1100 Vgrade with 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistrandedpassing through including heavy duty PVC concealed with all accessories surface type on wall/roof/floor/with concealed MS box / Surface type PVC box as required at site with laminated top cover duly earthed with 1.5 sq mm multistranded PVC insulated copper conductor cable for one fan pointcontrolled byone switch and taking down existing point wiring except PVC conduit all as specified and directed. |
| 62 | M&L for point wiring complete as specified with 1100 Vgrade with 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistrandedpassing through including heavy duty PVC casing capping with all accessories surface type on wall/roof/floor/with concealed MS box / Surface type PVC box as required at site with laminated top cover duly earthed with 1.5 sq mm multistranded PVC insulated copper conductor cable for one fan pointcontrolled byone switch and taking down existing point wiring except PVC conduit all as specified and directed. |
| 63 | M&L for Point wiringfor 15 Amps S/S combinationcomplete with 2 runs of2.5 sqmm , PVC insulated, unsheathed FRLS cable 1100 volts grade, multi stranded copper conductor drawnin existingPVC conduiton surface/ in wall/ roofetc. and including provision of one run of PVCinsulated 2.5 sqmm copper conductor for earth continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6mm thick MS sheet concealedin wall and laminated sheet cover of 3mm thick on top for housing theswitch socket complete and taking down existing point wiring except PVC conduit all as specified and directed. |
| 64 | Material and labour for, Sub main wiring with 2 runs of 4sqmm PVC insulated, unsheathed FRLS multi stranded copper conductor cable, 1100 volts grade, drawn through and including suitable size of PVC conduit pipe and accessories on surface/wall/ roofetc. with one run of PVC insulated, 4 sqmm FRLS cable, copper conductor for earth continuity conductor and removing existing u/s sub main wiring complete all as specified and as directed.Note: - 2 runs of main copper conductor, 1 run of earth continuity and 1 run of conduit will be measured as one unit length. |
| 65 | Material and labour for, Sub main wiring with 2 runs of 2.5 sq mm PVC insulated, unsheathed FRLS cable, 1100 volts grade, multi stranded copper conductor, drawn through and including suitable size of PVC conduit pipe and accessories on surface / wall / roofetc. with one run of PVC insulated, 2.5sqmm FRLS cable, copper conductor for earth continuity conductor and removing existing u/s sub main wiring complete all as specified and as directed.Note: - 2 runs of main copper conductor, 1 run of earth continuity and 1 run of conduit will be measured as one unit length. |
| 66 | Supply and fix in repairs, switch socket combinationflush type universal2 in 1, 3 pin 15Amps 230 volts ISI Marked. |
| 67 | Supply and fix in repairs, DOL starter mk-I suitable for three phase air circulator fan all as specified and as directed. |
| 68 | Supply, Jointing, testing and laying in trench / floor / wall etc pipes galvanised iron \"Medium Grade \" ISI marked with all running fittings of size 25 mm bore complete all as specified and as directed |
| 69 | Supply, Jointing, testing and laying in trench / floor / wall etc pipes galvanised iron \"Medium Grade \" ISI marked with all running fittings of size 20 mm bore complete all as specified and as directed |
| 70 | Supply, Jointing, testing and laying in trench / floor / wall etc pipes galvanised iron \"Medium Grade \" ISI marked with all running fittings of size 15 mm bore complete all as specified and as directed |