}

Tender For Provision Of Ladies / Gent Toilets & Additional / Alternator To Roof Parapetsunder Age B/R Iii At Chandimandir, chandimandir-Haryana

Statutory Bodies & Commissions/Committees has published Tender For Provision Of Ladies / Gent Toilets & Additional / Alternator To Roof Parapetsunder Age B/R Iii At Chandimandir. Submission Date for this Tender is 18-12-2024. Toilet Bathroom Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

46412103
Corrigendum : Tender For Provision Of Ladies / Gent Toilets & Additional / Alternator To Roof Parapetsunder Age B/R Iii At Chandimandir
Open Tender
Indian
Haryana
Chandimandir
18-12-2024

Tender Details

Tender For Provision Of Ladies / Gent Toilets & Additional / Alternator To Roof Parapetsunder Age B/R Iii At Chandimandir; 1 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. 2 Excavation over areas in hard/dense soil not exceeding 1.50 metre in depth and getting out complete, all as specified. 3 Excavation over areas in hard/dense soil exceeding 1.50 metre but n.exc 3.00metrein depth and getting out complete, all as specified. 4 Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. 5 Removal excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified & directed. 6 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. 7 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in flooring etc, complete all as specified and directed. 8 Moorum /red bajri filling as in sub base for floors or pavings, laid in layers n.exc. 15cm thick, spreading, leveling and ramming including watering complete all as specified and directed. 9 Hard core of gauge of broken stone or boulders, not exc 63mm , deposited spread and lavelled in layers n-exc 25 cm watered & rammed to a true surface ,complete all as specified. 10 Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete, all as specified. 11 Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. 12 Plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection, 75mm thick, laid to slope of 1:20, finished even and smooth, with 10mm wide joints to full depth @ 2.5m c/c and at corners, filled with mastic mortar, including dismantling of PCCof complete all as specified and directed. 13 Mild steel TMT bars 10mm dia and over ,cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed. 14 Material and labour for mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified. 15 Plain cement concrete type B-0, 1:2:4 using (2012.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. 16 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate)as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). 17 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate)as in coloumns, pillars etc complete all as specified and directed (reinforcement shall be measured and paid for separately). 18 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5 metre span and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). 19 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate)as in chajja etc, shelves and the like complete, all as specified and directed. 20 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, balconies, roofs, canopies shelves and the likecomplete all as specified and directed (reinforcement shall be measured and paid for separately). 21 Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed. 22 Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. 23 Form work to sides of pillars, coloumns and similar items (square, rectangular or polygonal) including edges rough finished surface of concrete flat complete all as specified and directed. 24 Form work to soffits of suspended slabs such as roof slabs rough finished surface of concrete flat not exc 200mm thick complete all as specified and directed. 25 Form work to chullah hoods, chajjas and similar items including edges / sides and soffits of lintelsetcrough finished surface of concrete flat complete all as specified and directed. 26 Form Work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work exc10cm but n.exc 20cm wide complete all as specified and directed. 27 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. 28 Brick work with sub class ‘B’ bricks of old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. 29 All as per serial item No 28 herein before but except bricks (using old serviceable bricks) –ditto- 30 Brick work with sub class ‘B’ bricks ofold size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. 31 Preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper overand including a coat of primer complete all as specified and directed. 32 Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick rendering in cement mortar 1:6 complete all as specified and directed. 33 Glazed ceramic coloured tiles of size 1200mmx600mmx 7mm thick as in dado, set and jointed in neat cement slurry and grouted in white cement complete as on vertical surfaces over and including 10mm thick bedding layer in CM 1:4complete all as specified and directed. 34 Glazed ceramic coloured tiles of size 300mmx450mmx 7mm thick as in dado, set and jointed in neat cement slurry and grouted in white cement complete as on vertical surfaces over and including 10mm thick bedding layer in CM 1:4complete all as specified and directed. 35 Rendering 15mm thickon fair faces of brick worksurfaces, finished even and fairin cement mortar (1:4), inclunding using water proofing compound, complete all as specified.Note : WPC shall be measured and paid separately. 36 10mm thick rendering in Cement and Sand mortar 1:6 over concrete /brick surfacesfinished even and smooth without using extra cement, complete all as specified & directed. 37 5mm thick rendering in Cement and Sand mortar 1:3 concrete surfaces as in ceiling / chajjas facia at any position finished even and smooth without using extra cement complete all as specified and directed. 38 Supply only Integral waterproofing compound, all as specified. 39 Cement concrete tiles 200mm x 200mm x 20mm thickset, jointed and pointed in neat cement slurry with grey cement as in roof tiless, laid over and including 20mm thick screed bed in cement mortar 1:4, complete all as specified and directed. 40 Preparation of new plastered surfaces of walls and applying two coats of cement base paint (any colour) including all necessary scaffolding and safety arrangements, complete all as specified and directed. 41 Vitreous china squatting pan, “Orissa” pattern size 580mm x 440mm white, with integral foot rests(excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, set with cement concrete, complete all as specified & directed. 42 PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection with PTMT nuts and 32mm dia CP flush pipe (long type for squatting pan), complete all as specified & directed. 43 Single Piece WC with UF Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fitting, Fixing Accessories, Size: 375x650x800 mm, P Trap- 180 mm, fixed in position, complete all as specified and directed. Make : Jaguar ARS-WHT-39751P180UFSMZor equivalent as approved in Appx C 44 Viterous china bowl 385x325x635 urinal with Consealed sensor, ivory/ white colour with CP Brass urinal spreader, urinal coupling CP Brass and discharge pipe including providing & fixing plugs, waste pipe , bedding urinal against wall in CM 1:2, securing urinal to plugs screws, pointing around urinal back in white cement complete all as specified and directed.Make : Urinal : Jaguar-URS-WHT-13253N, Urinal Sensor: Jaguar-SNR-STL-51087or equivalent as approved in Appx C 45 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type moulded door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. 46 Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. 47 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement,complete all as specified & directed. 48 PVC(SWR) waste pipe, 110mm bore, single socketed in any length with cement/ rubber ring joints, laid in trenches or infloor,complete all as specified and directed. 49 PVC(SWR) waste pipe, 75mm bore, single socketed in any length with cement/ rubber ring joints, laid in trenches or infloor,complete all as specified and directed. 50 PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc,complete all as specified and directed. 51 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed. 52 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed. 53 4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading)in square n.exc 0.5 Sqm in each panes complete all as specified and directed. 54 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, float valve, ball valve 20mm PTMT,compelte all as specified in SSR Part-I and all as directed by Engineer-in-charge. 55 Table top wash basin, of Size 575x 430 x 175mm, white colour, including waste pipe, CP angle valve, CP waste coupling etc fixed in position,complete all as specified and directed.Make : Jaguar Cat Part ACS-WHT-87901 or equivalent as approved in Appx C 56 Beveled edge looking mirror, 5.5mm thick of selected quality glass, including wood finish PVC mouldingmounted on 6mm thick ply or of PVC frame fixed to wall with screw and rawl plugs,complete all as specified and directed. 57 Steel water tubes, 15mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors,complete all as specified and directed. 58 Steel water tubes, 20mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors,complete all as specified and directed. 59 Steel water tubes, 25mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors,complete all as specified and directed. 60 Bib tap, short body, fancy typecast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union,suitable for 15mm bore pipe, complete all as specified and directed. 61 Brass stop valve,screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 20mm bore pipe,complete all as fixed as in repair specified and directed. 62 Stop valve, cast copper alloy, chromium plasted screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed. 63 4mm thick False ceiling fibre cement board, white in colour , 595mm x 595mm in size, fire and moisture resistance, fixed with and including standard GI snap grid framing (Powder coated) and suspended not exceeding 900mm below from ceiling with 3mm dia wire including clips and misc fittings etc in pattern as approved by GE, fixed as in repair (size of panel shall be of 605 x 605mm and GI snap grid framing shall be of 1mm thick standard section i.e. channels, angles, tee etc),complete all as specified and directed. 64 10mm thick toughned glass as in partitions and similar work including cutting to shape, drilling holes required complete all as specified and directed. 65 Granite stone slabs, 16 to 18mm thick,width and length as per site requirement, best qualitymachine cut andpolished to be fixed infloors,cooking plateform, tread, raiser of steps and vertical surfaces etc and jointed with gray cement slurry and pointed in white cement mixed with marble dust (1:2) with admixture of pigment to match the shade of slab, rubbing, cutting / rounding of edgesand corners where required with and including 15 mm thick screed bed in cement mortar 1:4, Complete all as specified and directed. 66 Hand Shower (Health Faucet) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer), fixed in position, complete all as specified and directed. Make : Jaguar Cat Part ALD-573 or equivalent as approved in Appx C 67 Sensor operatedcast copper alloy chromium plated Tall body pillar tap opal prime sensor faucet for wash basin (9V transformer) complete all as specified and directed. Make : Jaguar Cat Part SNR-15017PMEB or equivalent as approved in Appx C 68 PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specified and directed. 69 75mm size,butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge. 70 200mm aluminum anodized barrel tower bolts of extruded section, complete all as specified. 71 150mm size aluminium handle (ISI Marked), cast type, anodised complete all as specified & directed 72 Plain cement concrete type C-2, 1:3:6 using 40mm graded crushed stone aggregate as in bed to drain pipes including cradle of 150mm bore pipe after the pipes are laid and tested , complete all as specified and directed. 73 RCC pipes class NP2150mm dia bore, with collars, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed (excavation, earthworkand PCC shall be measured and paid for separately) 74 Demolition of brickwork built in cement mortar or cement lime mortar, including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed 75 Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar, demolition of mud phuska of any thickness includingremoval of rubbish from site complete all as specified & directed. 76 40mm thick brick tileswith including 20mm thick cement mortar 1:4 jointedgrouted and pointed complete mixed with crude oil5%by weight of cementcomplete all as specified and directed. 77 All as per serial item No 76 herein before but except tiles –ditto- 78 PCC 1:3:6 type C-1 (20 mm graded stone aggs) as in roof padding, roof kerbs rounded or chamfered on edgescomplete all as specified and directed. 79 Demolition of reinforced cement concrete of any description, in any position not specifically provided for, complete all as specified and directed. 80 Taking down cement plaster on brick / stone walls or ceiling (up to 10 mtr height) including raking out joints, hacking for key, scrubbing down with water, etc , complete all as specified and directed. 81 Rendering 15mm thick (average thickness) plaster in cement mortar 1:4 mixed with WPCon concrete roof surfaces including flashings and junction of parapets etc ,finishing the surface even and fair without using extra cement all as specified and directed by Engineer-in-charge. Note :- WPC will be measured & paid separately as supply only). 82 3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, over primer coat bonding material of blown bitumen 85/25 grade heated to working temperature of 180° C applied @1.2Kg/Sqm. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructionsincluding dismantling of existing felt /treatment, complete all as specified & directed. 83 Preparation of new surfaces of any description of wall, facia, ceiling, RCC etc and applying two coats of oil bound destemper over one coat of interior wall primer including wall care putty (average thickness 1.5 to 2.5mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering for making the surfaces even and smooth complete all as specified and directed. 84 Complete removal of existing treatment of any type/ descriptin viz distemper, white wash etc from plastered / un plastered surface of wall, chajjas, facia, cantilivers, RCC etc with mechanical means / grinder completely and applying two coats of oil bound distemper over and including one coat of interior wall primer including interior grade wall care putty (thickness vary from 1.5 to 2.5mm as required for desired smoothness and leveling of surfaces in two or more layers)and sand papering, making the surfaces even and smoothcomplete all as specified and directed. 85 Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0,all as specified and directed. 86 Two coats of synthetic enameled painton steel and iron surfacesover 10 cm width or girthincluding preparation of new surfaces complete all as specified & directed. 87 Repair to RCC sunshades, chajjas, balconies, coloumns, bands, beams and similar RCC work at any position / height by dismantling loose / disintegrated portion including necessary scafolding and safety arrangements and dubbing out with cement concrete 1:1.5:3, 20mm thick, using 6 to 12mm graded stone aggregate to make up and finished the required shape including provision of necessary scaffolding and formwork up to three storey bldg if required and finished with 5mm thick rendering in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed. 88 Preparation of old existing plastered / unplastered surfaceand applying two coats of exterior emulsion paint in approved tint over one coat of exterior wall primer on existingsurface of building(all as per manufactures instructions) with and including necessary scafolding and safety arrangements complete all as specified and directed. 89 Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified & directed by Engineer-in-charge. 90 1mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed with self tapping screws etc complete all as specified & directed . 91 Conventional LLDPE septic tank of capacity 1000 litre, designed to carry sewage and sullage water, connection etc complete all as specified and directed. MAKE : SINTEX or equivalent as approved by Engineer-in-Charge 92 Precast SFRC cover of size 1200 x 600mm complete all as specified and directed. 93 Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. 94 All as per serial item 93 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed 95 All as per serial item 93 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 96 All as per serial item 93 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor 97 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 98 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 99 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 100 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 101 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 102 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 103 LED lamp9 watts, B-22 type complete all as specified . 104 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. 105 MCB, SP, 240 volt,40 Amps, 10 KA , B series including connection with suitable size aluminium / copper lugs complete all as specified and directed 106 MCB ,SP, 240 volt, 6 Amps to 32 Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 107 LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed. 108 Slim LED lights fitting, 4 feet,1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 109 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cableshall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth 110 LED panel surface mounted -2x2 - 36 wattscool day light fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed complete all as specified and directed. 111 Ultorn 17 watt wall light 220 volt (warm white) size 54.50cm x 10cm x 3.50cm including connecting up with three core flexible copper conductorcabble of suitable size complete all as specified and directed. 112 ABS plastic1800W White Crescent Wall Mounting hand dryer machine (ISI Marked) suitable for bathroom compelte all as specified and directed. 113 Wall mounted type automatic sanitary NakshatraTechnologyautomatic sanitary napkin destroyer incinerator machine 230 volt of capacity 8 to 10 Napkins per load , of size 230 x 230x 320mm for ladies toilet complete all as specified and directed.MAKE : NAKSHATRA, Model Blue or equivalent as approved by Engineer-in-Charge. 114 Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed. 115 Flourish waterproof classy and smart look bollard garden light grey, with bulb corded electric metal, including connection complete all as specified and directed. 116 XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 2core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. 117 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 11-12-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-12-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 99500.0 /-
Tender Value
INR 49.75 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail