Strengthening Of Street Light Poles In Sector-60, Noida - Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection. UPPWD-2018, PS-1455 CAT-AAA 2 Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20 mm) of specifiedsize and shape including form work, plastering if required, curing etc. as required. (volume of pole/ pipe not to be deducted) DSR-2018, 11.5 3 Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mmthick suitable for wind velocity as per IS 875 part 3 &having no circumferential weld, with accessories forhigh mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor platesetccomplete in all respect as per direction of E/I. UPPWD-2018, PS-651 4 Supply and burying of 600 mm x 600 mm x 6.0 mm GI plate, vertically for eathing with its top at least 3 meters below ground level complete with 20 mm dia. GI Pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 12 mm. dia. GI Pipe up to switch board (from appron to switch board the cost of GI pipe and GI wire will be extra) 30 cm. square GI Frame with hinged cover, masonry housing, alternate layers of charcoal/coke and salt at least 150 mm. thick alround etc. as per direction of Engineer-in-charge complete in all respects (This will apply for earthing of poles also). UPPWD-2018, PS-702 5 S/L of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects (P.S. No. 716) 6 S/L of Al. armoured cable PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I.Complete in all respects . The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(PS No. 501) UPSR -2018a)- 16 sq. mm 4 core 7 b)- 10 sq. mm 2 core 8 c)- 16 sq. mm 2 core 9 d) 50 Sq.mm. 3.5 Core 10 S/F of Plain or Pin type copper tin plated cable socket (Lug)to the cable lead, insulating with tape and making connector etc. Complete in all respects as per Direction of E/I (PS No. 504) UPSR-2018a)-16 sq. mm 11 Supply and fixing Following automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN,UPPWD-2018, PS-8071. 40 AMP SPN 12 2. 40 AMP TPN 13 Painting of the electric pole with 2 coats of aluminium paint after cleaning of pole. Complete in all respects as per direction of E/I. UPPWD-2018 P.S. No. 634 14 Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. UPPWD-2018 PS-627 15 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Complete in all respect as per direction of E/I. Above 10 Mtr and 12 MtrDSR-2018(Electrical) 11.3.4 16 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. E/I. UPPWD-2018 PS No. 1423 Catt-AAA 17 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR-18 (Elect.) Item No-14.16-a)-63 mm dia (OD-63 mm & ID-51 mm nominal) DSR-18 (Elect.) Item No-14.16.1 18 b)-90 mm dia (OD-90 mm & ID-76 mm nominal) DSR-18 (Elect.) Item No-14.16.2 19 M.S. Strip (50x6mm ) Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2019) pg-53 20 FRP Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2019) pg-53 21 Excavation in foundation in ordinary soil (Loam, clay or sandy) including lift upto 1.50 M and lead upto 30 M. And including filling watering and ramming of excavated earth into the tenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I upto a distance of 30 M. from the foundation trenches (Where machine con not reach/move) For Building work only as in item 251A P.W.D. (SOR) 22 Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR-2018 12.34 23 S/F of Pole Junction Box of size 240x130x110 mm with NOIDA Embossing, hinged & locking arrangement and M.S. Clamps made of 50x6 mm. flat as per drawing including 2 Nos. HDPE. Pipe 32 mm dia having 0.75 Mtr. length each.complete in all respects as per direction of E/I. Make- Sintex/Equivalent make(AOR) 24 Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&Pcomplete in all respect as per direction of E/I. UPPWD-2018, PS-647 25 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect..P.S. No-641 26 S/F of 2.5 sq.mm x 3 core cable as per AOR 27 Demolishing R.C.C. Work Manually by mechnical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of E/I. (AOR) 28 Laying old Cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. All complete as per the direction of engineer (AOR) 29 Taking out existing CC interlocking from footpath/central verge, including removal of rubbish etc, disposal of unserviceable material to the dumping ground, for wich payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of E/I. (AOR) 30 S/L of Al. Armoured cable XLPE insulated served & sheathed cable 1100 V grade at 750 mm ground level protective with brick 25 sq.mm x 2 core, Complete in all respects as per direction of E/I. (AOR) 31 Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.(DSR-2018, 12.42) 32 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metreDSR-2018, 11.3.1 33 S/F of straight MS Channel 125x65 mm (13.1 per kg) 175 mtr. Long including packing piece clamp & all nuts and bolts fixing on pole. complete in all respects. As per direction of E/I. (UPERC-2019 P-45) 34 S/F of 11 KV pin 12 long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc. complete in all respects as per direction of E/I (UPERC-2019) Pg-39 35 Supply and fixing of following type plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer- Incharge. UPPWD-2019 (PS No. 504) -1. 185 Sq.mm. 36 S/E testing & commissioning of 63 KVA copper wound outdoor type distribution transformer as per ISS : including inspection fees etc. complete in all respect (UPER-2019) pg-51