Tender For Work For Repair, Reconstruction, Construction And Infrastructure Facilities In Janta Inter College Sujra Baghpat (Vk Baghpat) - Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5 m in width as well as 10sqm on plan including getting out and disposal of excavated earth upto 50m and lift upto 1.5m,as directed by Engineer Incharge in cartage DSR 2.8.1. 2 Diluting and injecting chemical emulsion for post constructional antitermite treatment.treatment of soil under existing floor udsing chemical emulsion @ one litre per hole,300mm apart including drilling 12mm diameter holes and plugging with cement mortar 1:2 (one cement:2 coarse sand DSR NO 2.35.3.1 3 Filling avilable excavated earth (excluding rock) in trenches,plinth,sides of foundation etc in layers not exceeding 20cm in depth ,consoliding each deposited layer by ramming and watering upto all lift5th km lead DSR NO 2.25(a) 4 P/LayingIN position cement concrete of 1:5:10 ( 1cement:4coarse sand: 8 graded stone aggrgate 40mm nominal size derved from natural sourse DSR NO 4.1.10. 5 Brick work with common burnt clay (non modular) bricks of class desination 7.5 in foundation in cement mortar 1:4( 1 cement :4 coarse sand ) DSR NO6.1.1. 6 Reinforced cement concrete work in beams, suspended floors ,roofs, having slope upto 15 degree landing, balconies, shelves, chajjas , lintels bands.plain window sills, above plinth level.uptofloor level five .excludingthe cost of centering and shuttering,finishing and reinforcement with 1:1.5:3 drived from natural source DSR N05.3 A 7 supplying and filling in plinth with sandunder floor, including watering, ramming,consolodating and dressing complete.DSR N02.27 8 Brick work with common burnt clay machine non moulded perforated bricks class desination 7.5 confirming to IS2222 in Super structure above plinth level upto floor level five in cement mortar 1:6 DSR NO 6.32.2 9 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer.Complete al Complete all as perDSR 10.2 10 providing and laying in position cement concrete in sill of window andhold fast .excuding cost of centering and shuttering DSR 4.1.3 in 1:2:4 ratio 11 providing and laying in position specified grade of reinfocement cement concrete, excluding the cost of centering and shuttering upto plinth level in1:1.5:3 I (1cement:1.5 coarse sand:3 graded stone grite 20mm nomina size DSR NO 5.1.2 12 Reinforced cement concrete work in beams, suspended floors ,roofs, having slope upto 15 degree landing, balconies, shelves, chajjas , lintels bands.plain window sills, above plinth level.uptofloor level five .excludingthe cost of centering and shuttering,finishing and reinforcement with 1:1.5:3 drived from natural source DSR N05.3 13 Steel reinforcement for R C Cwork including strainthening, cutting, bending,placing in position and binding all complete Fe 500 D .DSR NO 5.22.6 14 S/F of fan box etc all complete. As per DSR NO10.18 15 12 mm thick plaster over wall of 1:6 cement & Coarse sand mortar over even surface including supply of all materials, labour and T&P etc. as per DSR NO 13.4.2 16 15 mm thick plaster over wall of 1:6 cement & Coarse sand mortar over rough surface including supply of all materials, labour and T&P etc. as per DSR NO.13.5.2 17 12 mm thick plaster over wall of 1:4 cement & coarse sand mortar over even surface including supply of all materials, labour and T&P etc. as per DSR NO13.4.1 18 15 mm thick plaster over wall of 1:4 cement & coarse sand mortar over rough surface including supply of all materials, labour and T&P etc. as per DSR NO 13.5.1. 19 S/Fixing of glass stripsfor 4 mm thickness in joint of floor etc all complete. as per DSR NO11.13.1 20 40mm thick P.C.C. flooring in 1:2:4 cement coarse sand and 20mm stone gritfinished with a floating coat of neat cement,including cement slurry.complete. 40mm thick Asper DSR NO11.3.1 21 P/Fixing of 110mm dia Rain water P V C down pipe with bendall complete. as per DSR NO12.41.2. 22 Distempering two coat with oil bound distemper of approvedbrand i/c all complete as per DSR NO 13.41.1 23 Finishing of wall with two coat of water proofing cement paint of approved quality and makeas per DSR NO13.44.1.. 24 Providing wall putty 2mm thick over new surface of approved quality and brand like Berger/j.k./Birla or similar two coats as per DSR 13.80. 25 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per code.No. -13.62.1 26 Supply and Fixing of 20 mm thick Kota stone in flooring and joint filled with 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 25 mm thick base coat in 1:2 with cement and coarse sand mortar and polished with hand machine required for proper completion of work as per DSR NO11.26.1 27 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. as per SI no. 11.37 A 28 Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) Complete all as perDSR 22.14.1 29 Chequerred precast cement concrete tiles 22 mm thick in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning of tilesetc. complete on 20 mm thick bed of cement mortar 1:4 (cement & coarse sand) Dark shade pigment using ordinary cementas per D.S.R.No.11.20.3 30 Providing and fixing stainless steel (Grade-304) railing made of hollow tubes, channel and plates etc including welding, grinding, bufing ,polishing and making curvature etc. complete sa per D.S.R. No.10.28. 31 supply and fixing Galvanised mosquitos proof heavy quality iron wire gauge or expended metal heavy quality over windos and including supply supply flat iron 25mmx4mm and including,supply of necessary screws all materials, labour T&P etc required for proper completion of the work DSR NO10.29.1 32 Centering and shuttering including stutting,proppingetc,and removing of form beam,slab,bandDSR NO 5.9.3 33 Centering and shuttering including stutting,proppingetc,and removing of form collumn n5.9.6 34 Centering and shuttering including stutting, propping etc. and removal of form.Foundation as per SI- 5.9.1 35 Suppy and fixing M S sign boardand complete with all respect. 36 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. As per DSR E&M Ser No1.10.2 Group B 37 Wiring forcircuit/submain wiringalongwithearthwire withthe following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq.mm + 1 X 2.5 sqmm earth wireAs per DSR E&M Ser No 1.14.2 38 Wiring forcircuit/submain wiringalongwithearthwire withthe following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4. sq.mm + 1 X 4 sqmm earth wireAs per DSR E&M Ser No1.14.3 39 Supplyingandfixing two modulesteppedtypeelectronicfan regulatorontheexistingmodularplateswitchboxincluding connections but excluding modular plate etc. as required. As per DSR E&M Ser No 1.25 40 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin5/6Amodularsocketoutletand5/6Amodularswitch, connections etc. as required. As per DSR E&M Ser No 1.31 41 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch. connections etc. as required. As per DSR E&M Ser No 1.32 42 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mmFRLS PVC insulated, copperconductor,single corecable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.As per DSR E&M Ser No 1.45 43 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providingand fixing 25 A modular socketoutletand25 AmodularSPMCB, C curveincluding connections, paintingetc. as required.As per DSR E&M Ser No 1.57