| 1 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 3 | Demolition of brickwork or stone / boulder masonry built in cement mortar or cement lime mortar incl all quoins, arches, pillars etc., but excluding ashlar facings, dressed stone work and precast concrete articles. |
| 4 | Taking down chowkats or frames with shutters (without taking off shutters from frames) exc. 1.5 Sqm but n. exc 4 Sqm each including making good disturbed surfaces |
| 5 | All as per item No 4 above butn exc 1.5 Sqm each. |
| 6 | M & L forglazed ceramic coloured joint free tiles in vertical surfaces,350 x 250 x 7mm or 450 x 350 x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement including cement screed 10mm thick in CM 1:3 all as specified and as directed. |
| 7 | M & L for 25 mm thick Cement concrete type 1:2:4 B-1, using 20mm graded stone aggregate as in levelling course. |
| 8 | M & L for Non skid ceramic coloured joint free tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm,in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:4complete all as directed |
| 9 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces finishedeven and smooth without using extra cement in CM 1:4 with liquid water proofing liquid as per manufacturers instructions on sunken slab of toilets.Note : Water proofing and LW+measured and paid separately |
| 10 | M&L for APP based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3mm thick reinforced with polyester non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete including taking down existing water proof membrane, cement screed, concrete surfaces (or) mudpuska of any type and any thickness etc and removal of debris obtained from removal of existing roofing incl mtrl incl screed mtrl as specified herein and deposited to the locations all as specified and directed . The laying of water proofing treatment shall be as per the Guide lines given in SSR/Zonal specification (latest) and as directed and specified. |
| 11 | M&L for plain cement concrete 1:5::10 type E-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete |
| 12 | M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM 1:4 incl pointing in white cement 1:2 using marble dust with admixture of pigment or mat. |
| 13 | M & L for Rounding to edges of Granite / stone slabs one edge such as in steps, cooking platforms and other similar situations. |
| 14 | Cutting out bricks, forming toothing for and bonding new into old work including value of new materials entering old walls and jointing and pointing in CM 1:6 (measured on vertical face in contact with old wall only). |
| 15 | M&L for old size Brick work with fly ash bricks straight or curved on plan and 6 metre mean radius built in CM 1:6 all as specified |
| 16 | M&L for old size Brick work with fly ash bricks straight or curved on plan and 6 metre mean radius in half brick thick walls built in CM 1:4 all as specified |
| 17 | M&L for Anodised aluminium (minimum 50 micron)frame for doors, windows, ventilators and grills/guard bars etc with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 18 | M&L for Anodised aluminium window and ventilator shutters, sliding typewithout sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. anodised alum fittings such as peg stays, handles complete all as specified |
| 19 | M&L for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified. |
| 20 | M&L for Figured glass, pin head type 4mm thick, and glazing with oil putty in square n exc 0.5 sq. m in each pane and fixed to aluminium frame using rubber packing complete all as specified and as directed. |
| 21 | S&F Solid PVC door Frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing. |
| 22 | S&F Factory Made Solid PVC Moulded Door Shutters28 to 30mm thick with wood free EPS (stiles) with 2,4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face. supplying & fixing in frame at site as per manufacturers instructions. |
| 23 | Cutting openings through brick walls built in cement mortar for door, window and other openings or enlarging existing openings converting window into door openings etc., or cutting out defective brickwork for underpinning fixing and removing shoring cleaning etc., all as specified |
| 24 | Forming jambs etc., to openings (to foregoing item) including cutting toothing and properly bonding into old work also facing jointing and pointing to match existing work complete in CM 1:4 all as specified |
| 25 | S&F 100 mm size mild steel butt hinges, medium weight, cold rolled fixed with stainless steel screw with frame |
| 26 | S&F 75 mm sizemild steel butt hinges, medium weight, cold rolled fixed with stainless steel screw with frame |
| 27 | S&F Aluminium anodised barrel tower bolts of extruded section 200 mm size |
| 28 | S&F Aluminium anodised barrel tower bolts of extruded section 125mm size |
| 29 | S&F Extruded aluminium alloy handles, fabricated type, anodised 150 mm long |
| 30 | S&F Extruded aluminium alloy handles, fabricated type, anodised 125 mm long |
| 31 | S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 32 | M & L for RCC nominal mix 1:2:4 type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams etc., |
| 33 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work incl sides of slab, n exc 200mm thick (Horizontal or sloping) for flat rough finished surfaces of concrete. |
| 34 | M & L for RCC nominal mix 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.50m clear span, lintel bands, roof bands and other similar items incl necessary form work all as specified. |
| 35 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking, hooking ends and binding with MS wire annealed not less than 0.9mm dia or securing with clips. |
| 36 | All as per item no 35 above but 6mm to 8mm dia |
| 37 | All as per item no 35 above but 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders. |
| 38 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1 : 3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring etc., in brick walls and making good, cutting exc 10 cm but n exc 20 cm girth |
| 39 | S&FVitreous china wash down water closet (pedestal pattern), white, of style and pattern as existing, complete with and including providingplastic seat cover, white fixedall as directed.(Make: Hindware / Parryware) |
| 40 | S & FChromium platedhealth faucet with CP connection and hook fixed all as directed. Make ; Parryware Cat no: T9937A1 or equivalent. |
| 41 | S & FPVC valveless syphonic action type, flushing cistern, low level, white, 10 ltrs, with inlet ball valve, float, handle and flush pipe incl. brackets including 32 mm dia flush pipe |
| 42 | S&F Vitreous China wash basin, white, oval shaped counter top size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets cutting for and pinning in ends of brackets or erecting or fixing of supply and waste pipe all as specified |
| 43 | S & F brass chromium plated 32mm bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed. |
| 44 | S & F PVC connection 15 mm size with PTMT nuts of length 450mm. |
| 45 | S & F low density 32mm dia bore polythene waste pipe (LDPE) of pressure rating 6 Kgf / Cm2 |
| 46 | S&F Pillar taps15mm borecastcopperalloywithcapstan heads chromium plated, fancy type, screweddown high pressure with or without lettered \"hot\" or \"cold\" with long screwed shanks and fly nuts screwed for iron pipe. |
| 47 | S&FBibtaps15mm borecastcopperalloywithcrutch or butter fly handle chromiumplatedscreweddown forironpipeorfor brassferrulefixed. |
| 48 | S&F450 x 600 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers fixing complete. |
| 49 | S&Fstop valves15 mm bore chromium plated with long shank and cup (Concealed type) high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed |
| 50 | S & F Brass chromium plated, tubular towel rail, 20mm dia, D type, 60cm long between flanges. |
| 51 | S & F 5mm thick Glass shelves for bath room corner set of three (10\",8\",6\") all as directed. |
| 52 | M&L toilet paper holder brass chromium plated as in repair complete .(Make: Jaquar continental Cat No .ACN -1151N -or equivalent.) |
| 53 | S& F stainless steel peg set of 5 as approved. |
| 54 | Demolition and breaking up drain pipes any type set in cement mortar |
| 55 | S&FPVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floor , 75mm bore. |
| 56 | S&FPVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed to walls, 75mm bore. |
| 57 | S&FPVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid inwalls, 110 mm bore. |
| 58 | S&FPVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed to walls, 110 mm bore. |
| 59 | S&F PVC (SWR) bend 110 mm bore. |
| 60 | S&F PVC (SWR) floor trap with grating including jointing to solvent cement wastepipe 75 mm dia. |
| 61 | S&F PVC (SWR) Gullytrap 125 / 110mm setting and jointing withsolvent cement. |
| 62 | S&F PVC (SWR) vent cowl 110 mm |
| 63 | S&F PVC (SWR) junction single, (Single T) equal or unequal for 110 mm bore pipe with access door |
| 64 | S&F PVC (SWR) junction single, (Single T) equal or unequal for 75 mm bore pipe with access door |
| 65 | S&F PVC (SWR) bend 75 mm bore. |
| 66 | Grating doom 100mm dia of PTMT Minimum weight 25gms) |
| 67 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof Bore of pipe 110 mm |
| 68 | S & F in repairs three layered rotational moulded polyethylene water storage tanks of capacity 1000 litres (cylindrical, vertical with closed top) hoisted and fixed in position all as specified including taking down old tanks |
| 69 | S & F Ball valves 25 mmhigh pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. Minimum weight 25mm - 455gms |
| 70 | S&F in repairs25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe. |
| 71 | S&F in repairs50mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe. |
| 72 | Taking up or taking down steel/iron tube of 20 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 73 | Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/floors complete all as specified. |
| 74 | Taking up or taking down steel/iron tube of 25 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 75 | Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/floors complete all as specified. |
| 76 | Taking up or taking down steel/iron tube of 50 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 77 | Supplying and laying of 50 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/floors complete all as specified. |
| 78 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc |
| 79 | M&L for Rendering 10mm thickin CM 1:6 on fair faces of brick work or concrete surfaces and finishedeven and smooth without using extra cement on internal wall surfaces. |
| 80 | M & L for rendering 10mm thick in CM 1: 6 as under layer and 5mm thick in CM 1:4 mixed with water proofing compound as finishing layer to external wall surfaces and finishing the surface even and smooth includingtaking down existing cement plaster if necessary. |
| 81 | Supply only liquidwater proofing chemical. |
| 82 | Complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer over 3mm thick wall care putty to internal wall surfaces complete all as specified and as directed. |
| 83 | Preparing new plasteredwall surfacesandapplying two coats of oil bound distemper over a coat ofprimerall as specified and as directed. |
| 84 | Complete removal of existing treatment on walls and applying two coats of exterior weather proof paint over a coat of weather proof primer to all external wall surfaces complete all as specified and as directed. |
| 85 | S & F 605 x 605mm anodised aluminium snap grid frame work for false ceiling including suspending wire all as specified |
| 86 | M & L for providing 12mm thick Gypsum board in ceiling fixed with screw as per manufacturers instructions. |
| 87 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil |
| 88 | All as per item No 102 here-in-before but depth exc 1.5m and n.exc 3m |
| 89 | Cement concrete 1:4:8 type D2 as in foundations using 40mm graded stone aggregate, filling and mass concrete |
| 90 | Cement concrete 1:2:4 type B2 as in foundations using 40mm graded stone aggregate, filling and mass concrete |
| 91 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat rough finished surfaces of concrete |
| 92 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surfaces of concrete, square |
| 93 | M & L for RCC nominal mix 1:2:4 type B-1 using 20mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass |
| 94 | M & L for RCC nominal mix 1:2:4 type B-1 using 20mm graded aggregate as in Columns, pillars, piers, posts and struts |
| 95 | M & L for RCC nominal mix 1:2:4 type B-1 using 20mm graded aggregate as in coping, lintels upto 1.50m clear span, lintel bands, roof bands and other similar items incl necessary form work |
| 96 | M & L for MS Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 97 | Framed work such as portions framed and hung as gatesincluding pintle hinges, stops, hand-made sliding bolts, etc , grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; and similar work conforming to Fe.290.Gde-E-165 |
| 98 | All as per item No 112 above but ornamental and intricate design |
| 99 | M&L for Rendering 10mm thickin CM 1:3 on fair faces of brick work or concrete surfaces and finishedeven and smooth without using extra cement on internal wall surfaces. |
| 100 | Finishing walls with Acrylic Smooth exterior paint of required shade. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer including priming coat of exterior primer incl preparing wall surfaces plastered |
| 101 | Two coats of synthetic enamel paint over a coat red oxide primer incl preparing Surfaces of any description, over 10cm in width or girth, not otherwise described |
| 102 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/ dense soil |
| 103 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 104 | M & L for providing broken stone boulders hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface. |
| 105 | M & L for providing 75mm thick cement concrete 1:4:8 type D2, using 40mm grades stone aggregate as in sub base to flooring. |
| 106 | 40mm thick Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate |
| 107 | Brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, in CM 1:4 |
| 108 | M&L for Rendering 15mm thickin CM 1:4 on fair faces of brick work or concrete surfaces and finishedeven and fairon external wall surfaces. |
| 109 | Preparing new plasteredwall surfacesandapplying three coats of white wash |
| 110 | S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.,conforming toFe-290 (Gde E-165). |
| 111 | S & F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified |
| 112 | S & F hand rails, half round or other steel section, drilled and countersunk for balusters, wind ties for roof including securing bolts, posts and struts in fencing etc., conforming toFe-290 (Gde E-165). |
| 113 | Two coats of synthetic enamel paint over a coat red oxide primer incl preparing Surfaces of any description, girth n.exc 10cm in width or girth not otherwise described |
| 114 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface, in hard/dense soil |
| 115 | S & F Plate girder or single stanchions, base plate, Post, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections incl welding etc, Fe 410W (Gde-E-250) Quality-A |
| 116 | S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates |
| 117 | Cutting holes into or through brickwalls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required, Superficial arean.exc 150 sq cm |
| 118 | S & F Mild steel Diameter of neck, 11 to 15mm screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long |
| 119 | M&L for flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 for wind ties of roof including securing bolts. |
| 120 | Two coats of synthetic enamel paint over a coat red oxide primer incl preparing Surfaces of any description, but n.exc 10cm in width or girth, not otherwise described |
| 121 | S & F plastic speed breaker of 250mm x 370mm x 65mm Model No. SW065ABS of make \"Sloway\" or equivalent, material made up of ABS and fixing the speed breaker as per manufactures instructions and all as specified and as directed. |
| 122 | S & F Powder coated anodised aluminium frame / shutters for doors, Partitionswith one or more rebates including jointing cleat for fixing etc., complete all as specified. |
| 123 | M & L for 9mm thick pre laminated particle board, interior grade, prelaminated both side with decorative choice laminations fixed with aluminium glazing clipalum snap beading, screws etc., complete all as specified. |
| 124 | S&F 100 mm sizestainlesssteel butt hinges, medium weight, cold rolled fixed with stainless steel screw with frame |
| 125 | S & Aluminium (extruded section body)Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed |
| 126 | S & F Sheet glass 5.5mm thick, ordinary quality and glazing with rubber gasket in square exc 0.5 Sqm in each pane |
| 127 | Supply only Rubber gasket to fix Gazing in Aluminium shutters / Partitions. |
| 128 | M & L for 100mm size Mortise latch with two levers (vertical type) brass body |
| 129 | M&L for rendering 10 mm thick in CM (1:3) on ceiling surfacesof chajjas and finishing the surface even and smooth. |
| 130 | M&L for preparation of new ceiling surfaces and applying two coats of oil bound distemper over a coat of primer on new plastered ceiling surfaces complete all as specified and as directed. |
| 131 | Taking down carefully copper/ Aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, making good the disturbed surfaces and taken as credit all as directed. |
| 132 | Material and Labour for Point wiring complete with 1.5 sqmm FRLS single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor drawn through and including non-metallic rigid PVC conduit PVC conduit fittings and conduit accessories concealed in walls, roofs and floors etc., including Modular flush boxes and Modular cover plates for switches concealed in walls, roof and socket / electronics fan regulator / telephone socket,including provision of 1.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for one light/fan point controlled by one way switch complete including cutting chases, pinning in, making good tofacing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10 Cm girth all as specified and as directed. |
| 133 | (a) One light point controlled by one switch. |
| 134 | (b) One 3 pin 5 amps switch socket on independent board. |
| 135 | (c) One 3 pin 5 amps switch socket on same board along with other switches. |
| 136 | (d)One exhaust point controlled by one switch |
| 137 | All as per item No.88 above but with 4 sqmm FRLS copper conductor cable with 2.5 sqmm PVC copper conductor cable as earth continuity conductor for one socket outlet 15/16 amps controlled by one switch15/16 Amps on independent board all as specified and as directed. |
| 138 | M&L for sub main wiring with PVC insulated, 1100 volts grade single core FRLS multistranded copper conductor cable conforming to IS specifications, 2 runs of 10 sqmm including one run of 10 sqmmsingle core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories or casing capping incl accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old unsvall as specified and directed. |
| 139 | Supply and fix Wall mountedLED 20W Batten Basic all purpose surface and wall mounted LED batten with Aluminium housing & Integrated electronic driver all as specified and as directed. |
| 140 | Supply and fixing wall mounted LED batten, Extruded aluminium housingprovided efficient heat dissipation withpolycarbonate diffuser with integrated electronic driver high efficacy.short circuit & voltage cut off protection, wide operating voltage range of 140V to 270V wide, lumen output of 1050,10W including lamp with complete all as specified and as directed. |
| 141 | Supply and fix MCB Distribution board , 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link,04ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. |
| 142 | Supply & FixMCB SPN230 volts, 40amps \"C\" Curve 10 kA Capacity including taking down Old MCB completeall as directed. |
| 143 | Supply & FixMCB SP 230 volts,40amps \"C\" Curve 10 kA Capacity including taking down Old MCB completeall as directed. |
| 144 | S & F Ceiling rose surface Bakelite 65mm x 50 mm two to three terminals all as directed. |
| 145 | S & F Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed |
| 146 | S & F Modular switch 1 way 16A, 1 module, 240 Volts complete all as specified and directed |
| 147 | S & F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed |
| 148 | S & F Modular socket 6 A/ 16 A -2/3 pin combined 2 module complete all as specified and directed |
| 149 | Supply and exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers includuing all accessories as per site requirement complete all as specified and as directed. |
| 150 | Supply and fixmetal clad socket single pole and neutral enclosure with a two pin and earth plug top and socket complete with one single pole MCB 240 Volts 20Amps all as specified and as directed. |
| 151 | Supply and Fix wallfan of size 300 mm sweep white in colour of white , plastic bodyall as specified and as directed. Make: Havells FHWPCPTWHY16 or equivalent in Bajaj/ CG/ Usha |
| 152 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified. |
| 153 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 380m sweep with, blades, and frame and louvers complete all as specified. |
| 154 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers complete all as specified. |
| 155 | Taking down fan, sealing cable end, Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store |