| 1 | PART-I : REPAIR / REPLACEMENT OF PERIMETER LIGHT, SECURITY LIGHT, POLE PAINTING AND ALL CONNECTED E/M ITEMS |
| 2 | Excavation in trenches, n.exc 1.5 m wide and n exc 1.5 m in depth; for foundation laying of cables ,etc or for shafts,wells,cesspits,manholes,pier holes,etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/lose soil, complete all as specified and directed. |
| 3 | Returning, filling in including spreading,levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil under floor, complete all as specified and directed. |
| 4 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed. |
| 5 | M&L for filling clean dry, dirtless, river sand in trenches / ducts for cushioing to cable protection, complete all as specified and directed.[Note : Only punned thickness shall be taken for payment.] |
| 6 | Supply and laying common burnt clay building bricks, sub-class ‘B’ designation 75 for cable protection, complete all as specified and directed. |
| 7 | Taking out old cable cover (Bricks) of any size from any location, keeping in safe custody and relaying with same brick for using cable cover protection of any location, complete all as specified and directed. |
| 8 | Taking down old unserviceable, underground cable of any size from any location, complete all as specified and directed. |
| 9 | Boring of horizontal holes / trenchless hole for 50 mm bore pipe under the road below 1.50 mtr from the road / hard surface by trencheless technology using ultrasonic technique and including necessary machine without damaging the existing road and getting out in any type of soil and disposal of soil to a distance not exceeding 50 m from the site of work, complete all as specified and directed.[Note : Pipe shall be measured and paid seperately.] |
| 10 | S&F galvanised iron tubing 40 mm bore, light grade with all fittings & fixture as in cable protection laid in trenches / floor or on the Pole etc., complete all as specified and directed. |
| 11 | Supply, laying, fixing, testing on completion XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 35 Sqmm 4 core, complete all as specified and directed. |
| 12 | Supply, laying, fixing, testing on completion XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 25 Sqmm 4 core, complete all as specified and directed. |
| 13 | Supply, laying, fixing, testing on completion XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 16 Sqmm 4 core, complete all as specified and directed. |
| 14 | Supply, laying, fixing, testing on completion XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 10 Sqmm 2 core, complete all as specified and directed. |
| 15 | M&L straight through joint, heat shrinkable type, suitable for LT under ground cable of size 16 sqmm to 25 sqmm, 3.5/4 core, complete all as specified and directed. |
| 16 | S&F in repairs 70 watt LED street light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning, over voltage & short circuit, IP66 Protection and fixing on 40 mm dia of bracket, complete all as specified and directed. |
| 17 | S&F in repairs 45 watt LED street light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning, over voltage & short circuit, IP66 Protection and fixing on 40 mm dia of bracket, complete all as specified and directed. |
| 18 | S&F in repairs 120 watt LED flood light fitting made up of pressure die cast aluminum housing with toughened glass and high powered individual LEDs with secondary optics, constant current driver with in built protection against lightning, over voltage & short circuit, IP66 Protection, complete all as specified and directed. |
| 19 | S&F in repairs Power contactors MNX 63 Amp coil voltage 230V AC, complete all as specified and directed. |
| 20 | S&F in repairs \"C\" series, TPN, MCB for AC applications conforming to IS / IES 60898-2002, 63 Amp, 10 KA, complete all as specified and directed. |
| 21 | Taking down high mast light of size 12/15/16 mtr from its base wih help of crane, cleaning, greasing and overhauling of all movavable parts like pullies, steel wire, chain, winches etc., replace unserviceable light if required, and refix the mast on its original position, complete all as specified and directed.[Note : (i) Including charges - Labour charges, Hire charge of crane, greasing and overhauling.(ii) Excluding charges - Serviceable flood light.] |
| 22 | Rewinding of three phase electric motor 1.5 HP for highmast system of suitable size, with copper wire, complete all as specified and directed.[Note : Cost of copper binding wire is included in quoted rate.] |
| 23 | Cleaning the swaged steel tubular street light poles 9 meters height including GI pipe of street light fitting and prepare surfaces cleaning including scrapping up of old corroded paint dirt / dust / rust carefully and M&L & applying two coats of aluminium paint over one coat of zinc chrome red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including writing of pole numbers and two coats colour washing of PCC coping, complete all as specified and directed. |
| 24 | Cleaning the swaged steel tubular street light poles 11 meters height including GI pipe of street light fitting and prepare surfaces cleaning including scrapping up of old corroded paint dirt / dust / rust carefully and M&L & applying two coats of aluminium paint over one coat of zinc chrome red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including writing of pole numbers and two coats colour washing of PCC coping, complete all as specified and directed. |
| 25 | M&L for numbering of pole number using stensils with black colour of synthetic enamel paint, complete all as specified and directed. |
| 26 | M & Learthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized Iron earth strip 25 X 4 mm thick by means of nuts bolts washers etc as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, galvanized iron pipe light grade 15 mm diameter for protection of earthing wire, (To be concealed in wall/floor) connected to earthing test point, all as shown in electrical plate No. 3 of MES Schedule Part I. , connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with aPCC (1 3 6) type C1 using 20mm graded stone aggregate earth chamber ,40mm thick RCC cover type B1 (1 2 4 ) B1 using 20mm graded stone aggregate with 8 mm dia tor reinforcrment 100mm c/cand 12 nn dia MS bar handle on top of cover on ground level, 20 mm dia GI watering pipe, funnel, etc. complete and testing resistance in completion all as specified and directed. |
| 27 | S&F in repairs PVC insulated, unsheathed 1.5 sqmm 3 core industrial copper cable for 230 Voltage, complete all as specified and directed. |
| 28 | Taking down unserviceable light fitting from 9/11 mtr electric pole and S&F Drivers for LED street lights 45W/60/70W, 230 Volts, 50 HZ existing make and after replace unserviceable driver with new refix again existing place, complete all as specified and directed. |
| 29 | Taking down unserviceable light fitting from 9/11 mtr electric pole and S&F Drivers for LED Flood lights 100W/120W, 230 Volts, 50 HZ existing make and after replace unserviceable driver with new refix again existing place, complete all as specified and directed. |
| 30 | Supply and replace aluminium lugs suitable for 25 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers, complete all as specified and directed. |
| 31 | Supply and replace aluminium lugs suitable for 16 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers, complete all as specified and directed. |
| 32 | S&F HOT moulded (FRP) jucntion box for street light pole with locking arrangement with IP-65 protection of size 250 x 250 x 150 with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP with two steel bracket to fix with pole and aluminium bus bar of rating 200 Amps, complete all as specified and directed. |
| 33 | PART-II : REPAIR / MAINT OF REFRIGERATION AND SUMMMER COOLING APPLIANCES, ACs AND OTHER CONNECTED WORKS |
| 34 | Taking out Split type AC of capacity up to 1.5 Ton (both Indoor & Outdoor unit) from the site and make for servicing, cleaning with air blower of fins, cleaning of condensing unit, cooling coil and evaporative coilwith caustic soda mix water, taking out all dirt / sludge etc. by using pressure pump, cleaning of air filter incl. Oiling and greasing of condensing fan motor, find out leakage of condensor / cooling unit, Replacement of remote cell / battery replacing worn out rubber, bushes / rubber packing rectification of unusual noise. Replacement of minor parts such as nut / bolts, washers etc. and reassembly of complete AC unit & refixing the unit both indoor & outdoor in same position and testing complete for smooth functioning to entire satisfaction of Engineer-in-Charge. |
| 35 | Supply & charging only of refrigerant (as per existing refrigerant) to Air conditioner of any type, make and capacity, complete all as specified and directed. |
| 36 | S&F in replacement of defective PCB card suitable for split / window AC, any type or size, complete all as specified and directed. |
| 37 | S&F in replacement of electric fan / blower motor (copper wounded), AC volt, single phase with recommended RPM etc. suitable for AC of any type and size, complete all as specified and directed. |
| 38 | Supply and charging only of suitable refrigerant (as per existing refrigerant) gas for refrigerator / water cooler of any type, make and capacity, complete all as specified and directed. |
| 39 | S&F in replacement of defective electric fan motor (copper wounded), for water cooler of 40/80 cooling capacity, complete all as specified and directed. |
| 40 | S&F in replacement of fan motor (copper wounded) for deep freezer of cooling capacity upto 345 ltrs, complete all as specified and directed. |
| 41 | Dismantling to voltage stablizer upto 5 KVA for repair including assembling, testing after repair work & refixing in old position, complete all as specified and directed. |
| 42 | Taking down old unserviceable / worn out sub main wiring any size and M&L for Sub main wiring complete with two single core 4 sqmm, 1100 volts grade, PVC insulated, stranded copper conductor FRLSH cable with continuous copper earth conductor of 4 sqmm of FRLSH in and including PVC casing caping incl accessories, complete all as specified and directed.[Note : (i) Making good of disturbed surfaces will be done by contractor without any claims.(ii) 3 runs of 4 Sqmm conductor and one run of PVC casing caping shall be measured as one unit length.] |
| 43 | S&F in replacement of sheet metal enclosure with single pole and neutral with a two pin and earth plug and socket complete with one double pole 20 Amp MCB, complete all as specified and directed. |
| 44 | M&L & Taking out defective compressor Sealed Rotary / Reciprocating unit of Split AC of capacity 1.5 Ton incl. cutting of copper tubing without any damage to existing other parts and Material and labour for replacement of compressor / sealed unit complete with erection of compressor in same location with suitable base, jointing of copper refrigerant pipe line, charging of gas to required level, leakage testing, NRV etc. including testing for smooth functioning, complete all as specified and directed.[Note : (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fittings, etc. complete with necessary guarantee period including oiling and environment friendly gas charging, testing etc.(ii) Purchase Voucher, Test Certificate & Guarantee Certificate shall be submitted for claiming of payment.] |
| 45 | All as per Item Ser No. 2.11 above but Split type AC of capacity 2.0 Ton, complete all as specified and directed. |
| 46 | All as per Item Ser No. 2.11 above but Refrigerator / deep freezer Compressor (235-280 litre), complete all as specified and directed. |
| 47 | All as per Item Ser No. 2.11 above but water cooler Compressor (40/80 Ltr), complete all as specified and directed. |
| 48 | S&F in repairs electronic refrigerator / water cooler defrost thermostat as per OEM, complete all as specified and directed. |
| 49 | S&F in repairs / replacement wiring kit complete suitable for Split type AC 1.5 Ton capacity complete with lugs, thimbles and selector switch, complete all as specified and directed. |
| 50 | S&F in repairs / replacement of running capacitor, 45/60 mfd suitable for 1.5Ton capacity window/split type AC of approved make, complete all as specified and directed. |
| 51 | S&F capacitor 6/10 mfd suitable for split / window type AC, complete all as specified and directed. |
| 52 | S&F in repairs / replacement of starting and running relay suitable for window / split type AC 1.5/2 Ton capacity of approved make, complete all as specified and directed. |
| 53 | S&F in repairs / replacement of over load protection relay suitable for window / split type AC 1.5 Ton capacity of approved make, complete all as specified and directed. |
| 54 | Taking out unserviceable drain out pipe of split type AC unit and supply and fix new drain out pipe of approved make, complete all as specified and directed. |
| 55 | S&F in repairs / replacement of evaporating coil of split type AC of capacity 1.5 Ton, complete all as specified and directed. |
| 56 | S&F in repairs / replacement of condensing coil unit complete of outdoor unit of split type AC of capacity 1.5 Ton with approved make, complete all as specified and directed. |
| 57 | M&L replacement of chocked copper tube of size 1/4\" of split type AC 1.5 ton capacity, complete all as specified and directed. |
| 58 | M&L replacement of chocked copper tube of size 1/2\" of split type AC of 1.5 toncapacity, complete all as specified and directed. |
| 59 | M&L insulation coating / PVC air bubling insulation of circular dia to copper tube to upkeep the required temperture and over all protection to copper tubing of size 1/4\" or 1/2\", complete all as specified and directed. |
| 60 | Replacement of unserviceable remote with new suitable for machine of 1.5 TR split type AC, complete all as specified and directed. |
| 61 | S&F replacement of defective swing motor with new motor suitable for 1.5 ton window and split type AC, complete all as specified and directed. |
| 62 | S&F Push type Bib Tap for water cooler made of brass cromium plated for water cooler upto 120 Ltr capacity, complete all as specified and directed. |
| 63 | S&F in repairs 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded, complete all as specified and directed. |
| 64 | M&L finding out leakage with the pressure testing of the condensor / cooling unit / compressor of deep freezer / refrigerator 320 Ltr capacity, stop leakage by brizing / soldering including charging with existing refrigerant to required level and testing the refrigerator for the entire satisfaction of Engr-in-Charge, complete all as specified and directed. |
| 65 | S&F Ball brass valves size 15mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule, complete all as specified and directed. |
| 66 | M&L & replacement of fan blade of water cooler / blower as per existing sample at the ground, complete all as specified and directed. |
| 67 | Finding out leakage of condensor / cooling unit of water cooler of 40/80 Ltr capacity including dismantling the same for recharging and stop leakage by brazing / soldering with S&F of required materials including supply & charging with existing gas up to required level and testing complete as to the entire satisfaction of Engr-in-Charge, complete all as specified and directed. |
| 68 | S&F water tray suitable upto 120 Ltr capacity water cooler made of Stainless Steel and all as per sample, complete all as specified and directed. |
| 69 | S&F plug top 15 amps, 230 V, complete all as specified and directed. |