Bids Are Invited For 1 Taking down existing unserviceable street light fittings , all electrical connections all as specififed and directed. Each 15.00 2 Supply and fixing solar integrated system LED street light fitting 32 watt with Lithium ferrous phosphate battery dimming version(LFP),PIR inbuilt option of MPPT charge controller available solution with Li-Ion seperately available power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired with IP 66 or better ingress protection with inbuilt Lithium Battery 11.1V/12.8Volt 33Ah, provided with 2 LED indicators : a green light to indicate charging in progress and a red LED to indicate deep discharge condition of the battery, green LED glow only when the battery is actually being charged, battery included in the luminary enclosure, with water proof (IP 66 or better) and corrosion resistant, material of construction of solar light fitting shall be FRP, LED lamp 32 watt (W-LED, 180-200 lm/watt, CRI>70) with 120Degree vide angle lens for better light distribution and colour temp-5700-6500K, Solar PV Module mono crystalline, > = 66 Wp. complete including warranty for light fitting 2 years after completion of the work complete all as specified Each 15.00 3 Supply, Lay, Test & Commissioning cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 16 Sqmm, 4 core complete all as specified. RM 400.00 4 Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge. Cum 97.20 5 Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed by the Engineer-in- Charge Cum 43.86 6 Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge Cum 20.07 7 Supply and laying DWC HDPE pipes of pressure rating of size 32 mm bore laid in trenches for passing of cable complete all as specified and directed. 8 Dismantling exsting RCC & steel tubular poles with bracket & light and in lieu S&F 5 metre long hot dipped galvanised octagonal poles with top A/F 70 mm bottom A/F 130 mm, made out of 3mm thick HT sheet alongwith base plate of size 220*220*12mm, including 1500mm long single arm bracket made out of 48mm dia, GI pipe, M20 in PCD 205mm, 700mm long and projected 100mm, J type EN8 grade set of 4 Nos foundation bolts alongwith templates, also including provision of the followings :- (a) MCB,SP,6A,230V, B series, 10KA mounted on and including 3mm thick plastic laminated sheet-01 No. (b) 4 way connector, bolt type having locking arrangement, weather proof and water proof control space : 01 No. Notes: (a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete of the pole concrete. (b) The earth work, RCC foundation reinforcement and form work will be measured and paid separately. (c) The quoted rate shall also be deemed to include for fixing of old light fitting retrived from dismantling. Make : BAJAJ Model BOP-7030 or its equivalent in Crompton/Philips / Wipro as approved by the GE. Each 8.00 9 Dismantling exsting RCC & steel tubular poles with bracket & light and in lieu S&F 7 metre long hot dipped galvanised octagonal poles with top A/F 70mm bottom A/F 130 mm, made out of 3mm thick HT sheet alongwith base plate of size 220*220*12mm, including 1500mm long single arm bracket made out of 48mm dia, GI pipe, M20 in PCD 205mm, 700mm long and projected 100mm, J type EN8 grade set of 4 Nos foundation bolts alongwith templates, also including provision of the followings :- (a) MCB,SP,6A,230V, B series, 10KA mounted on and including 3mm thick plastic laminated sheet-01 No. (b) 4 way connector, bolt type having locking arrangement, weather proof and water proof control space : 01 No. Notes: (a) The rate quoted shall also be deemed to include the cost for provision of 50mm bore PVC pipe from cable trench to centre of the pole concrete of the pole concrete. (b) The earth work, RCC foundation reinforcement and form work will be measured and paid separately. (c) The quoted rate shall also be deemed to include for fixing of old light fitting retrived from dismantling. Make : BAJAJ Model BOP-7030 or its equivalent in Crompton/Philips / Wipro as approved by the GE. Each 13.00 10 M&L for reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) for foudations, footings,columns, postd, pillars etc & in any location, complete all as specified and directed.(Note:Reinforcement and dorm work will be measured and paid separetly) Cum 13.1 11 M &L for TMT steel bars 10 mm dia and over in reinforcement cut to length,bent to shape required, including cracking bending spirally forhooping for coloumns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm di or ecuring with clips etc, complete all as specified and directed kg 214.22 12 M&L for TMT steel bars 6 to 8 mm dia as in strirups, spacers,binders cut length bent to shape required, including cracking binding spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm di or ecuring with clips etc,complete all as specified and directed kg 269.39 13 M&L for use and waste of formwork to sides of concret foundations,footing,columns posts pillars etc and in any location for fair finished surfaces,completeall as specified and directed. Sqm 13.64 14 M & L in repairs for PVC copper cable 2.5 sqmm 3 core copper conductor 1100 Volt grade multi core multi stranded PVC insulated unsheated drawn through and including PVC conduit and accessories fixing on poles/ wall with clamps, nuts bolts etc from FRP box to street light fiting complete all as specified and direcetd RM 200 15 Supply and fix 4 Mtr Double arm Decorative type tubler Pole made Di-Cast Aluminium having LED Lanterns 30W each 2 Nos with IP-66 Protection Covered with Glass including Cable connection of 3 core Copper wire not less than 2.5sqmm for . The Tubler pole of thickness not less 3mm made shall be painted with Zinc Phospate Primer coated over coloured paint all as per IS : 2713 (1980) suitable for street Roads all as directed by the Engineer-in-Charge make : Suncity/Bajaj/Surya As Approved by The GE. Note: The above pole cost Including of J bracket bolt of 04 Nos suitable size, provision of Connector.Note :Excavation and Pole RCC Foundation work for each pole paid and measured Seperataly. Each 10.00 16 Supply, install and testing of out door type (Double door) LT Panel Powder coated, free standing type compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved company make as per CA factory fabricated by made out of 3.00 mm thick CRCA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Aluminum bus bars. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The out Going MCCB Shall be provided with copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame (Height 0.45 Mtr from GL) made of angle iron of size not less than 50 mm x 50mm x 6mm & detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back center openable lockable /openable by key from both sides. Make: Legrand/HPL/Seimens/Universal or equivalent. Location-: Opposite Samagri Bhawan Outdoor Panel (i)Aluminum bus bar Phases & Neutral for 600 Amps- 01 set (ii) MCCB 4 pole 400 Amp with breaking capacity 36 KA adjustable type with exended terminals -01 Nos Make: Legrand/Schneider/siemens/L&T (Incommer) (iii) MCCB 4 Pole 160 Amps 25 KA adjustable type with exended terminals -01 Nos Make: Legrand/Schneider/siemens/L&T- 01 Nos.(Out going) (iii) MCCB 4 Pole 100 Amps 25 KA adjustable type with exended terminals -01 Nos Make: Legrand/Schneider/siemens/L&T- 01 nos.(Out going) (iii) MCB SPN 63 Amps 10 KA- 24 Nos.(Out going) (iv) Manualy Change over 400 Amps (iv) Digital volt meter with CTs - 01 nos. (v) Digital Amp meter with CTs- 01 nos. Each 1.0 17 Supply, install and testing of indoor type (single door only front door openable) LT Panel Powder coated, free standing type compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved company make as per CA factory fabricated by made out of 2.00 mm thick CRCA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Aluminum bus bars. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The out Going MCCB Shall be provided with copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame (Height 0.45 Mtr from GL) made of angle iron of size not less than 50 mm x 50mm x 6mm & detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back center openable lockable /openable by key from both sides. Make: Legrand/HPL/Seimens/Universal or equivalent. Location-: MOORA Power House indoor Panel (i)Aluminum bus bar Phases & Neutral for 800 Amps- 01 set (ii) MCCB 4 pole 400 Amp with breaking capacity 36 KA adjustable type with exended terminals -01 Nos Make: Legrand/Schneider/siemens/L&T (Incommer) (iii) MCCB 4 Pole 160 Amps 25 KA adjustable type with exended terminals -04 Nos Make: Legrand/Schneider/siemens/L&T- 01 Nos.(Out going) (iii) MCCB 4 Pole 100 Amps 25 KA adjustable type with exended terminals -04 Nos Make: Legrand/Schneider/siemens/L&T- 01 nos.(Out going) (iii) MCCB TPN 63 Amps 16 KA- 04 Nos.(Out going) (iv) MCB SPN 40 Amps, 10 KA-02 (v) Digital volt meter with CTs - 01 nos. (vi) Digital Amp meter with CTs- 01 nos. Each 1 18 M&L for earthing using GI earthing strip 32 x 6mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm medium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick with one lifting handle made of 8mm dia MS bar funnel wie mesh and testing on completion including making test point on wall as per SSR specification all as specified and directed. Total Quantity : 1716