}

Tender For Provision Of Additional Cctv Surveillance System In Mata Gujri Hospital, Tilak Nagar Under Mcd West Zone.-Provision Of Additional Cctv Surveillance System In Mata Gujri Hospital, Tilak Nagar Under Mcd West Zone., Dsr Dar Electrical (With Cp Onl, Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Provision Of Additional Cctv Surveillance System In Mata Gujri Hospital, Tilak Nagar Under Mcd West Zone.-Provision Of Additional Cctv Surveillance System In Mata Gujri Hospital, Tilak Nagar Under Mcd West Zone., Dsr Dar Electrical (With Cp Onl. Submission Date for this Tender is 21-11-2024. Security Cameras Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

46202227
Tender For Provision Of Additional Cctv Surveillance System In Mata Gujri Hospital, Tilak Nagar Under Mcd West Zone.-Provision Of Additional Cctv Surveillance System In Mata Gujri Hospital, Tilak Nagar Under Mcd West Zone., Dsr Dar Electrical (With Cp Onl
Open Tender
Indian
Delhi
Delhi
21-11-2024

Tender Details

Provision of additional CCTV surveillance system in Mata Gujri Hospital, Tilak Nagar under MCD West Zone.-Provision of additional CCTV surveillance system in Mata Gujri Hospital, Tilak Nagar under MCD West Zone., DSR DAR ELECTRICAL (WITH CP ONLY)-2022, DAR ELECTRICAL-2022 and approved items; 2 122.2.46:SITC of 4MP fixed lens Dome IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better ** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better ** Lens: 2.8mm fixed Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE, DDNS, IEEE802.1X IR Range: Minimum 25m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL 3 122.2.47:SITC of 4MP fixed lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better** S/N ratio: >45 dB Lens: 2.8mm fixed Video Compression: H.265 or better** Resolution: (2650x1440) or better** Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 30m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard: IP66 or better** Safety standard: UL 4 122.2.60:SITC of 32 channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better** Network Throughput :200Mbps or better** USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 2 SATA port suitable for 6TB each Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL 5 122.2.62:SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch 6 122.2.68:SITC of 10 TB surveillance HDD 7 122.2.70:SITC of full HD LED Monitor,42 INCHES complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 300 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz at sitewith connections andalong with all accessories etc.complete as required. 8 122.2.72:SITC of IP65 box(without PoE switches)of dimention 310mmX160mmX140 mm onpole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 nos. 15/16 amp modular switch socket set 9 122.2.78:SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 5KVA 10 122.2.80:SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.6 U 11 DSR 2022 12 17.5.1:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 13 1.53.1:Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 14 1.53.2:Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable 15 1.53.3:Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable 16 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 17 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

Key Value

Document Fees
INR 590 /-
EMD
INR 20943.0 /-
Tender Value
INR 10.25 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail