| 1 | Dismantling of split air conditioning of capacity 1.5/2.0 TR complete with indoor/outdoor unit from any location of BKT Campus and deposited to MES yard and making good to disturbed surfaces matching as existingcomplete all as specified and directed. |
| 2 | Dismantling of desert cooler ,Water cooler & refrigerator any type and capacity from any location of BKT Campus and deposited to MES yard complete all as specified and directed. |
| 3 | Supply, installation,commissioning and testing of hi wall split type air conditioner inverter type of capacity1.5 TR (4500 K Cal/hr ) single phase suitable for 230 V + 10 %, 50Hz AC supply complete with cordless remote control unit using Non CFC refrigerant Gas,minimum 5 star rating and energy efficient complete comprising of following :-(a) indoor unit with three speed blower fan with motor of appropriate capacity including PCB,thermostatic control,air filter and drain for condensing water(b) Outdoor unit comprisingcompressor ,air cooledcopper condensor with fan and motor unit shall be installed outside the building / on roof(c) Refrigerant copper pipe for suction and discharge line with insulation ,condensing water drain pipe & protected by suitable size offlexible PVC conduit with control valves & safty accessories including control wiring for evaporator & condensing Unit with suitable size of copper cableMake: Daikin/Hitachi/Llyod/O\" General Note :-(i).Cutting holes in walls/windowof any thickness with cutting machine for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .(ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer inclusive in above rate. (iii) Powder coatedMS bracket/wall stand for fixing out door unit in wall or rooftop with necessary grouting MS hold fast ,boltsetc is included above rate. |
| 4 | Ditto- all as per item No. 03here in before but capacity 2 TR(6000 K cal/hr)complete all as specified and directed. |
| 5 | Ditto- all as per item No. 03 here in before but capacity 3 TR(7500 K cal/hr) 3 phase suitable for 415 V + 10 %, 50Hz AC supply complete all as specified and directed. |
| 6 | Supply and installation and testing of window type Air conditioner inverter type complete with cordless remote control unit using Non CFC refrigerant Gas ecofreindelywith minimum 5 star rating and energy efficient of capacity 1.5 TR (4500 K cal/hr) consisting of compressor, evaporator coil,copper condensor coil, candensor fan with motor and, PCB for better air flow complete all as specified and approved by EIC. Make: Daikin/Hitachi/O\" General/LloyedNote :-.(i) Electrical cable required to connectto voltage stabilizer to power supply point deemed to be inclusive in above rate.(ii) drain piping is included in above rate. (iii)cutting / opening of window any type for fixing of window AC including making wooden frame in existing window ofsuitable size for fixing of window AC complete packing of window after installation of AC complete all as per required at site is included in above rate. |
| 7 | Supply and installation of window type Desert 61L Air Cooler electric driven single phase 230 volt, 50 Hz, 235 watt power consumption , plastic body (extruded polystyrene) of air flow capacity 4000 CFM with movable stand including high efficiency Aspen cooling pad ,powerful double blower ,fully closeble louvers ,cool flow dispenser complete.Make :- symphony model JUMBO 65 DB or equivalent make in Havells/ voltas as approved by GE in writting. |
| 8 | Supply, installation/fixingelectric driven single phase 230 volt 50 Hz desert cooler (evaporator type) 6000 CMH steel body factory made fabricated with 22 mm gauge thick galvanised steel body and water storage tank of 100-120 ltr with powder coated paint in white silver color complete inner and outer side and anticorrosive paint inner side of tank .Desert cooler should have complete with wood wool cooling media ,manual air defusing system on grill,3 speed control regulator ,on/ off switch ,3 mtr long 3 core copper cable,single phase 18 inch exhaust fan 1400 rpm single phase 230 volt AC with air flow minimum 20ft ,water pumping set of suitable wattege (HP)submersible type single phase complete all as specified and directed. Make of exhaust fan/submersible motor : Bajaj/ Crompton/ Usha/ havells |
| 9 | Supply, installation and testing for refrigerator ,electric driven single phase 230 volt, 50 Hz, of capacity 210litrs (or next nearest capacity) frost free,minimum5 star rating complete all as specified and directed.Make - Samsung/ LG/ Whirlpool |
| 10 | Supply installation and testing for refrigerator ,electric driven single phase 230 volt, 50 Hz, of capacity 320 litrs (or next nearest capacity) frost free,minimum5 star rating complete all as specified and directed.Make - Samsung/ LG/ Whirlpool. |
| 11 | Supply,installation and testing water cooler fully stainless steel, electric driven (single phase) having approx storage capacity of 150 litres & nominal cooling capacity of 150 ltr per hoursincluding neceesary PVC connection pipe , Brass Stop Cock 15 mm ISI marked , PVC drainage pipe and electric connection complete minimum 5 star rating all as specified and directed Make:- Blue Star/ Voltas/ Usha ShriRam/ LG. |
| 12 | S&F Submain wiring with two single core PVCinsulated FRLSH multistrand copper conductor cable of size 4 Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCconduit not less than 25mm size ISI markedwith allfittings / accessories and 04 Sq mm FRLSH multistrand copper conductorcable as continuous earth wire complete all as specified & directed. Make- Polycab/ Finolex / Plaza/Grandlly/Havells. |
| 13 | S&F Submain wiring with two single core PVCinsulated FRLSH multistrand copper conductor cable of size 6 Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCconduit not less than 25mm size ISI markedwith allfittings / accessories and 06 Sq mm FRLSH multistrand copper conductorcable as continuous earth wire complete all as specified & directed. Make- Polycab/ Finolex /Plaza/Grandlly/Havells. |
| 14 | S&F Submain wiring with two single core PVCinsulated FRLS-H multistrand copper conductor cable of size 10 Sq mmdrawn into and including non metallic heavy duty rigid concealedPVCconduit not less than 25mm size ISI marked with allfittings / accessories and 10 Sq mm FRLS-H multistrand copper conductorcable as continuous earth wire complete all as specified & directed.Make- Polycab/ Finolex /Plaza/Grandlly/Havells. |
| 15 | S&F Sheet metal enclosure TPN 4 way double door distribution board,415 volt complete all as specified and directed |
| 16 | S&F Sheet metal enclosure SPN 8 way double door distribution board ,415 volt complete all as specified and directed |
| 17 | S&F MCB TPN100 Amps,240 V,50 Htz,10KA breaking capacity \"C\" curved type complete all as specified and directed. |
| 18 | S&FMCB SPN 63 Amps 240 volt,50 hz,10 KA breaking capacity \"C\" curved type complete all as specified and directed. |
| 19 | S&F MCBsingle pole, 6 to 32Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified and directed. |
| 20 | S& F sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete all as specified and directed by Engineer-in-Charge Make- Legrand/Havells/Anchor |
| 21 | S & F socket outlet5 pin 20 Amps modular type,2 module with suitable size of module metal flux boxes and including modular front cover plate and back plate for mounting modular type switch & socket with one single pole modular type MCB of capacity 20 amps (1 module) including electrical connection all as specified and directed.Make- Gold metal /Crab tree Legrand/Havells. |
| 22 | M&L for Chemical earthingcomplete with copper plate electrode of size 900mm x 600mm x5mm burried directly in ground vertically to a depth not less than 4.70 mtr below normal ground level (with top edge ofearth plate not less than 3.60 mtrs below ground level ) of earth pit size 1200mm x 600mm x 4700mmconnected to copper strip of size 32 mm x 6 mm as main earthing lead by means of brass nut and bolt / brazing at all joints and connected to earth test pointand testing on completion with and including necessary excavation and earth work in any type of soil and GI pipe medium grade 40 mm bore for protection of copper strip from earth electrode to earth test point with adequate quality of charcoal dust, common salt,magnesium sulphate,copper sulphate and bentonite powder solution in alternate layers of 150 mm thick layers all around the earthing plate and PCC (1:2:4) type B-1 using 20mm graded stone aggregate chamber/pit of size 300x300x300 mm on 900mm x 600mm x 100mm PCC (1:4:8) base intype C-2 using 40 mm graded crushed stone with RCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate )cover of size 400mm x400mm x50 mmreinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel flushed type handle 12 mm dia, PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering complete all as specified and directed as shown in drawing.Note- (a)Cost of copper strip and GI protection pipe up to distance 7.5 mtr shall deemed to be included in the quotated unit rate of above items.(b) On testing after completion of job , If desired earth resistance(less than 2 ohm) is not found the earthing shall be redone at no extra cost to govt. |
| 23 | M&L for earthing complete with copper plate electrode of size60cm x 60cm x 3.15 mm thick burried directly in ground vertically at a depth not less than 3.25 metredeep below normal ground level with top edge of the plate not lessthan2.5 metre below normal groundlevel surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using copper strip 20mm x 3 mm by means of bolts, nuts, check nuts and washers made of copper and protected by light grade 40 mm dia GI pipe connected to test pointand GI pipe medium grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1: 2:4) type C2 using 40mm graded stone aggregate including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 3 of SSR Part I ,complete all as specified and directed. |
| 24 | M&L forEarthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel beside welding at all joints as shown on drawing and inccluding excavation and earth work , GI pipe light grade 40mm bore for protection of gi strip from earth electrode toconnected upto test pointincluding the earth test point of galvanised iron/steel . supplying and laying of charcoal dust ,common salt ,PCC (1:2:4) type B-1 using 20mm graded stone aggreate chamberand RCC cover 40 mm thick (1:2:4 ) type B-1 using 20 mm graded stone aggregatereinforced with 6mm dia round bars @75mm c/c both ways with MS handle 12 mm diaPGI funnel and wire mesh ,20mm dia GI pipe medium grade for wateringall as shown in electrical plate No. 3 SSR Part -I and connected to earthing test point all as specified or indicated complete all as sufficient and directed. |