| 1 | Excavation for Foundation |
| 2 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
| 3 | P.C.C. Below Foundation M20 Grade- Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 4 | R.C.C. M35 Grade for Foundation Slab- Plain/reinforced cement concrete in foundation complete as per drawing and Technical Specifications Clauses 1200, 1500 & 1700 MORT&H Specification |
| 5 | HYSD Bar for foundation Slab- Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and Technical Specification Clause 1000 and 1202. |
| 6 | R.C.C. M-35 Grade for Sub Structure (Upto 5.0 m height)- Providing and laying reinforced cement concrete in superstructure as per drawing and Technical Specification Clauses 800, 1205.4 and 1205.5. |
| 7 | R.C.C. M-35 Grade for Sub Structure (Height from 5.0 m to 10.0 m)- Providing and laying reinforced cement concrete in superstructure as per drawing and Technical Specification Clauses 800, 1205.4 and 1205.5. |
| 8 | HYSD Bar for Sub Structure- Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 9 | Weepholes- Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 10 | Back Filling by Granular materials- Backfillingbehind abutment,wing wall and return wall complete as per drawing and Technical specification. |
| 11 | Back Filling by Sandy materials- Backfillingbehind abutment,wing wall and return wall complete as per drawing and Technical specification. |
| 12 | FilterMedia- Providingand laying of Filtermediawith granularmaterials/stone crushedaggregates/brickaggregates/riverbedmaterialssatisfyingtherequirementslaid down in clause 2504.2.2 of MoRT&H Specifications to a thickness of not less than 600 mm with smaller size towardsthe soil andbigger size towards the wall and provided overthe entire surface behind abu tment, wingwall and return wall to the full height compacted to afirmcondition complete asperdrawing and technical specification. |
| 13 | Elastomeric Bearing- Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete, including all accessories as per drawing and Technical Specification Clause 1207.1. |
| 14 | POT-PTFE Bearing- Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC : 83 Parts I & II respectively and other parts conforming to BS : 5400, Sections 9.1 & 9.2 and Clause 2006 of MORT&H Specifications complete as per drawing and approved Technical Specifications. |
| 15 | R.C.C. M-35 Grade for Super Structure (Height from 5.0 m to 10.0 m)- Providing and laying reinforced cement concrete in superstructure as per drawing and Technical Specification Clauses 800, 1205.4 and 1205.5. |
| 16 | HYSD Bar for Super Structure- Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 |
| 17 | Wearing Coat- Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and Technical specification Clauses 800 and 1206.3. |
| 18 | R.C.C. Railing of M25 Grade- Construction of R.C.C. railing of M25 grade in cast in situ with 20 mm nominal size aggregate, true to line and grade tolerance of vertical railing post not to exceed 1 in 500, centre to centre spacing between vertical posts not to exceed 2000 mm as per drawing and Technical Specification Clauses 800, 900 and 1208.3. |
| 19 | Drainage Spouts- Drainage spout complete as per drawing and Technical Specification clause 1209. |
| 20 | PCC(M15) Below Approach Slab- P.C.C. M15 concrete ordinary grade (1: 2: 4) leveling course below approach slab complete as per drawing and Technical Specification Clauses 800 and 1211. |
| 21 | Filler Joint- Providing&fixing2mmthickcorrugated copperplateinexpansionjointcompleteas per drawing & Technical Specification. |
| 22 | Filler Joint- Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification. |
| 23 | Filler Joint- Providing andfixinginposition20mmthick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto20mm,coveredwithsealant complete as per drawing and technical specifications. |
| 24 | Expansion Joint- Providing and laying of an elastomeric slab seal expansion joint complete as per approved drawing and approved specifications to be installed by manufacturer/ supplier or their authorized representative ensuring compliance to the manufacturer\"s instructions for installation and as per Technical Specification Clause 1207.2.5. |
| 25 | Pitching on Slopes- Providing and laying pitching on slopes laid over prepared filter media as per drawing and Technical Specifications Clause 1302. |
| 26 | Filter Material- Providing and laying filter material underneath pitching in slopes complete as per drawing and Technical Specification Clause 1302. |
| 27 | PCC Toe wall- Construction of toe walls for protection of slopes as per drawing and Technical Specification Clause 1302.5.I. P.C.C. M10 (Nominal Mix 1:3:6) |
| 28 | Citizen Information Board- Logo Board at starting point (As per fig. 107 of Road signage under PMGSY published by the NRRDA on Dec\"06) |
| 29 | Temporary Island- Providing and constructing temporary island 16 m diameter for construction of Well Foundation for 8 m dia well as per drawing and Technical Specification Clause 1200 MORT&H Specification |
| 30 | Service Road- Providing and constructing one span service road to reach island location from one pier location to another location. |
| 31 | Dismantling of Structures (Reinforced Cement Concrete by Mechanical Means)- Dismantling of existing structures like culverts, bridges, retaining walls and other structures comprising of Lime Concrete, Cement Concrete, Reinforced Cement Concrete, etc. including T&P and scaffolding whenever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and of 1000 m as per Technical Specification Clause 202. |
| 32 | Clearing and grubbing road land for Approach Road- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. of Specification of Rural Roads. |
| 33 | Construction of Embankment / Shoulder with Materials obtained from Borrow pits- Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 34 | Construction of Embankment / Shoulder with Materials obtained from Borrow pits- Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 35 | Construction of GSB (Gr-II)- Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. |
| 36 | Water Bound Macadam Base ; WBM Grading II- Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. |
| 37 | Wet Mix Macadam Base ; WMM - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with smoothwheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. |
| 38 | Bituminous Concrete- Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 percentof mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achievethe desired compaction as per MORTH specification Clause : 509 complete in all respects |
| 39 | Prime coat low porosity- Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 |
| 40 | Excavation in Hard Rock (Blasting Prohibited)- Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 |
| 41 | Good and Service Tax (18%) |