Repair And Renovation Work At Pension Nideshalay, U.P. Sector 24/2, Ifmtr Campus, Indira Nagar, Lucknow. , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. , Demolishing R.C.C. Work By Mechanical Means And Stockpiling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1 Kilometre, Stacking Serviceable And Unserviceable Material Separately Including Cutting Reinforcement Bars. , Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Pregranite Stone Slab Of Colour Black, Cherry/Ruby Redlaid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing Of Edges To Give High Gloss Finish Etc. Complete At All Levels. , Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. , Excavation In Foundation In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.50 Meter And Lead Upto 30 Meter And Including Filling, Watering And Ramming Of Excavated Earth Into The Trenches Or Into The Space Between The Building And Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Sur-Plus Earth As Directed By The Engineer Incharge Up To A Distance Of 30 Meters From The Foundation Trenches. , Providing And Laying Of Pcc 1:4:8 In Position Ready Mixed Or Site Batched Design Mix Cementconcrete For Plain Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana/ Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering And Finishing As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Minimum Specified Cement Content, The Contractor Shall Have Discretion To Eithe.R Re-Design The Mix Or Bear The Cost Of Extra Cement. Concrete Of M10 Grade With Minimum Cement Content Of 220 Kg /Cum , Sand Filling In Plinth Including Supply Of Necessary Quantity Of Sand From A Distance Not Exceeding 8 Kms. From The Site Of Work And Including Watering, Dressing Etc Rate To Include Cost Of All Materials Labour T & P Etc Required For Proper Completion Of Work. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chaijjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Lll) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). R.C.C. Works Above Plinth Lvl , P/F Mild Steel Or Iron In Plain Work Such As Reinforced Concrete Or Reinforced, Brick Work (When Not Included In Over All Rates ) Wrought To Required Shape As Necessary Including Bending For Proper Completion Of The Work And Including Supply Of All Steel And And Over Lapping & Hooks. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : Suspended Floors, Roofs, Landings, Balconies And Access Platform. , 15 Mm Plinth Plaster (1 Cement :4 Coarse Sand) F.M.-2.25 , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Fixing 12Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer In Charge (Door Handle, Lock And Stopper Etc. To Be Paid Separately) , Supply And Fixing Of Led Tube Light With Batten Suitable For Up To 1 X 22 Watt Led Tube Light Fitting Including Tube On Surface Complete In All Respect , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Amps Modular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required. , Providing And Laying Cement Concrete 1:4:8 (1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) Including Supply Of All Materials, Labour T & P Rtc Required For Proper Completion Of The Work And Curing Complete Also Including Cost Of Formwork In Foundation & Floors. , Providing And Injecting Chemical Emulsion For Preconstructional Antitermite Treatment And Creating A Chemical Barrier Under And Around The Column Pits Wall Trenches Basement Excavation Top Surface If Plinth Filling Junction Of Wall And Floor, Along The The External Perimeter Of Binding Expansion Joints, Surrounding Of Pipes And Conduits Etc, Complete (Plinth Area Of The Building At Ground Floor Only Shall Be Measured As Per I.S.6313(Partii 1981)Alderine Emulsifiable Concentrate Or Any Other Approved Material Such As Heptrachlor Or Chlordane Will Be Used. The Rate Of Application Of Chemical Emulsion Shall Be As Follows : (1)Treatment For Masonary & Foundation 5 Liters Per Sqm. (2) Back Fill In Immediate Contact With Foundation 7.5 Liters/Sqm (3) Treatment Of Top Surface Of Plinth Filling 5 Liters/Sqm (4) Treatment Of Soil Along External Perimeter Of Building 7.5 Liters/Sqm.(5) Treatment Of Soil Under Apron Along External Perimter 5 Liters/Sqm. , Rcc Work For Thelighterbeams I.E. Having Spans Upto 6 M. (Using 1:1.5:3 Mix Concrete) [1 Cement :1.5 Coarse Sand :3 Stone Aggregate] M-20 , Class 150 Brick Work In 1:6 (One Cement And Six Coarse Sand Sand Of 2.25 Fineness Modulus) Mortar Infoundation & Plinth Including Supply Of All Materials, Labour And T & P Etc Required For Proper Completion Of The Work. , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii): 4 Graded Stone Aggregate 12.5Mm Nominal Size) , Providing And Applying A Coat Of Bitumen Gradevg 10 Etc Complete. , R.C.C. Work With Cement Approved Coarse Sand And 20 Mm. Guage Approved Stone Grit Im The Proportion Of 1:1.5:3 [1 Cement :1.5 Coarse Sand :3 Stone Aggregate] In Lintels Of Doors And Windows Excluding Supply Of Reinforcement And Its Fixing And Binding The Same With 24 Bwg Binding Wire And Including Necessary Centering And Shuttering Etc.And Also Including Supply Of All Materials, Labour And Tools And Plants Etc, Required For Proper Completion Of The Works. Strength Of The Concrete Shall Not Beless Than M-20 , As In Item No. 1 Above But For Slabs (Using 1:1.5:3 Mix Concrete). [1 Cement :1.5 Coarse Sand :3 Stone Aggregate] M-20 , Brick Work In Super-Structure Above Plinth Level Up To Floor Two Level (Up To Two Storeys) Includingnecessary Cutting And Moulding Of Bricks As Requiredand Also Including Honey Comb Brick Work Thickness Of Wall Not To Be Less Than 1.5 Brick Thick. (1:6 Cement & Coarse Sand) , Same As In Item No. 3 But In1:4 Cement And Coarse Sand Mortar In Superstructure For Wall Thickness 12 Cms & Below Brick Work. , Providing And Laying Brick Coba 120Mm Thicklaid With M-150 Class Brick Bat Coba 7.50Cm Thick With Gap Of 15Mm To Eachother,Over 20 Mm Thick Base Of Cement Mortar1:4Cementand Coarse Sand Mixed With Water Proofing Compound Spreading Cement Slurry Mixed With Acrelic Cement Concrete Water Proofing Compound Filled Gaps Of Coba & Top Of Coba Mortar Mixed With Water Proofing Compound In 1:4 Cementandcoarsesandmortar Finised Smooth & Top Mashed False Square 30 Cm X 30 Cm And Side Wall Parapet Shall Be Mono Tythic Plaster Wall Up To 30 Cm Higher And Junction And Corner Shall Be Rounded By Brickballastcement And Coarse Sandmasonany Cobawithtop Finised Plaster Mixed With Acetic Water Proofing Compound@ 2%Byweight & Including S/O All Material, Labour, T& P Etc Complete For Proper Completion Of Work. , Providing & Fixing Isi Marked Flush Door Shutters Conforming Is: 2202 Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters(A) 35Mm Thick Including Isi Marked Stainlesssteel Butt Hinges With Necessary Screws. Double Leaf , Mild Steel Or Iron Work Of Small Sizes And Sections Such As Holding Down Bolts, Hold Fast Tierods,Gratings Etc. ( When Not Included In An Over All Rates) Wrought To Required From Including Supply Of Steel And Its Wastage Including Cost Of Bolts, Nuts If Required For And Welding, Grinding And Making Holes As Required Completion Of Work Fabrication Of Holes Doors, Chaukhats Nosing. Hold Fast For Chaukhats Of Doors/Windows. , Fly Proof Stainless Steel Grade 304 Wire Gauge With 0.5 Mm Dia. Wire And 1.4Mm Wide Aperture With Matching Wood Beading , Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : (A) 4 Mm Thick. , Fixing Of Door, Windows/Ventilators Chaukhats In Position.(A) Door/Window Chaukhats, , 12Mm Cement Plaster In 1:6 Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. , Cement Concrete Flooring 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 12-20Mm Nominal Size Laid In One Layer Neat Cement (25 Mm Thick Floor). , Painting Ist Coat Over Priming Coat (But Excluding Cost Of Priming Coat) On Steel Andothermetalsurfacesup To 10 Cm.Widthorgirthorsmall Articles Not Exceeding 0.10Sqm In Area White Superior Synthetic Enamel Such As Luxol3,Hi-Gloss Apcolitesuperlac,Dulux Specified Brushingtogiveanevenshadeand Including Cleaningthe Surfaceofall Dirt,Dust And Other Foreignmatter Sand Paperingand Stopingincluding Cost Of All Materials, Labour Toolsandplants Etc. Required Forpropercompletion Of The Work. (M.S. Works) , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade : New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) With Base , Distempering (Two Coat) With Oil Bound Distemper Of Approved Brand And Manufacture & Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over & Including A Priming Coat With Cement Primer Of Approved Brand & Manufacture Such As Berger,J&N, Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Droppings & Other Foreign Matters & Also Including Preparing The Surface Even With Plaster Of Paris Or Approved Synthetic Material & Sand Papered Smooth Including Cost Ofall Materials. , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete : 250X16 Mm , Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete :(A) 250 Mm X 10Mm , Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete : 125 Mm , Providing And Fixing On Wall Face Unplasticised-Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10Mm Gap For Thermal Expansion. 110 Mm Including Bend, Shoe,Khurras, Clamps Etc , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size M.S. Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Group Controlled (Looped) Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Midium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group C , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required2 X 2.5 Sq.Mm. + 1 X 2.5 Sq.Mm. Earth Wire , Supplying And Fixing Following Modular Switch / Socket On Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc As Required.5/6 Amps Switch , 15/16 Amp Switch,Socket Etc , Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm(Tolerance As Per Is : 374- 2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin,Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 1200 Mm Sweep Ceiling Fan , Supply Of Led Tube Light 20 Watt Polycarbonate Tube Light Complete Including Tube Etc Suitable For Both Surface & Surface Complete In All Respects. , Supply Of 7W Bulkhead Light Fixture With Specification Complete As Per Architectural Design , Supplying And Fixing Cable End Box (Loose Wire Box) Suitable For Triple Pole And Neutral, Sheet Steel, Vertical Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Testing And Commissioning Etc. As Required. , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Suplly And Burring Of Safe Earthing Electrode T-39 Cu Copper Coated, Length 2000Mm, Outer Pipe 76.3Mm X 3.2 Inner Pipe 42.4Mm X 2.6Mm, Terminal Dia 12Mm, Coating 80-100 Micron Filled With Crystalline Conductive Mixture (Ccm) Having Anti Corrosive & Conductive Property With 50Kgs Activated Soil (Bfc) Capable Of Reucing The Soil Resistivity With Good Mixture Of Retaining Capacity Along With 30Cm Square C.I. Frame Withhinged Cover & Mansonry Housing.(From Electrode Terminal To Switch Board, Cost Of 25X3 Copper Strip Will Be Extra) Make: As Approved In U.P.P.W.D & C.P.R.I. All Respects.