Supply, Installation, Testing & Commissioning of Electrical System, Library and IT Building at COEP Technological University Pune- 1 WIRING Concealing of Conduits 2 Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. 3 Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. 4 PVC Flexible 5 Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit 6 Bunch of Wires 7 Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 8 Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 9 Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 10 Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BWRate As per Note - 1 11 Modular switches and Accessories 12 Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. 13 Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. 14 Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. 15 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 16 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 17 Point Wiring 18 Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW 19 Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW 20 Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SW 21 Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW 22 Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG 23 FITTINGS INDOOR FITTINGS 24 Supplying and erecting of 20W, OPTIMA, LINEAR 4FT SUSPENDED BATTEN WITH 2000LM. PROPOSED CCT IS 5700K (LL24-251-XXX-57-CD) with required accessories 25 Supplying and erecting of 10W BULKHEAD LIGHT FIXTURE(IP 66) with required accessories 26 Supplying and erecting of WIPRO-CRCO10R038HP57GL-36W LED 2X2 LUMINAIRE SUITABLE FOR RECESSED ON GRID/POP CEILING) with required accessories 27 Supplying and erecting of WIPRO-ID06-171-XXX-57-XX-15W RECESSED MOUNTED CIRCULAR DOWNLIGHTS with required accessories 28 Supplying and erecting of WIPRO-LD80-171-XXX-60-SM- 18W IRIS SLIM, SURFAC EMOUNTED LED DOWN LIGHT with required accessories 29 Supplying and erecting of WIPRO-LD06-111-XXX-57-XX 9W RECESSED CIRCULAR LED DOWN LIGHT with required accessories 30 Supplying and erecting of WIPRO-LL20-111-XXX-65-NE1 10W, 2FT LIENAR, MIRROR LIGHT with required accessories 31 Supplying and erecting of WIPRO-LL13-181-65SESL-20W,4FT LINEAR LED TUBE CEILING MOUNTED with required accessories 32 FANS 33 Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF 34 Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. 35 APPLIANCES 36 Supplying, erecting, testing and commissioning of 15kVA capacity online pure sine wave with backup time of 15Min. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 1 phase output complete with all protections as per specification no. AP-UPS 37 Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS 38 Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete 39 Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete 40 SWITCHGEAR MCCBS 41 Providing & erecting 3 Pole MCCB, 415V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 42 Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 100A MCCB (Set of 8) 43 Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 100A MCCB. 44 MCBS 45 Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 46 Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 47 Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 48 Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 49 MCB DBS 50 Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB 51 Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB 52 Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB 53 Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness,surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB 54 Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB 55 RCCB / RCBO 56 Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 57 ENCLOSURES 58 Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. 59 MAIN PANEL 60 MAIN PANELIncoming from 630KVA Transformer-1One No. 1000A TP EDO ACB, 50kA along with requires quantity of NO/NC contact terminal for PLC signal with an arrangement for cable connection on one side & bus-bars connection on other side. ACB’s shall be completed with all the in built protections and as required.( U/V,O/C,S/C,E/F etc ) Incoming from 650KVA DG SET-1One No. 1000A TP EDO ACB, 50kA along with requires quantity of NO/NC contact terminal for PLC signal with an arrangement for cable connection on one side & bus-bars connection on other side. ACB’s shall be completed with all the in built protections and as required.( U/V,O/C,S/C,E/F etc ) Each Incoming Breaker Should be installed withDigital flush type class - I accuracy multifunction meter with 3 Nos. current transformers of 1000/5 ratio, 15 VA Class 1.0 metering.6 nos NO/NC contacts for remote opening & closing.Red/Green/Amber ON/OFF/TRIP indicating lamps with 2A SP MCB backup protection.1 set of three phase indicating lamps along with 2A SP MCB backup protection.Spring charge & DC supply healthy indicating lamp with 2A SP MCB backup protection.Motor wound spring closing mechanism.Suitable arrangement to receive incoming cable/busduct 1200 Amps.T-N-C Breaker control switch & RESET push button.Control fuses, control terminals & wiring as required.1 no.auto/manual selector switch.Reverse Power realy.Required relays for AMF logic.One automatic Battery charger consisting of:Transformer & Rectifier.DCAmmeter.DC Voltmeter.ON/ OFF/Trickle/Boost selector switch.Charger ON, OFF/ TRICKLE/ BOOST indications .12 Window annunciation panel for following indication / LampsSet fails to start.Engine overheatHigh Temperature.Low lube oil pressure.Over SpeedLow Fuel oil levelCooling water Flow failure.Breaker Trip.Generator fault.DC control supply failure.Spare.Spare.Panel for each incomer (1 From trafo. & 1 from DG)Incoming ACB with standard protections shall be provided with the following :Voltmeter (96 x 96 sq. mm. of range 0 - 240 Volt. with selector switch and required PT.Ammeter (96 x 96 sq. mm. ) of range 0-2500A for transformer and DG incomingwith selector switch and required CTs. 1 Sets of 3 Nos. phase indicating lamps suitable for 230 V/AC fittings with individually 6 A TP MCB back up.1 Nos.multi function meter with required CTs / PTs 3 Nos. phase indicating lamps suitable for 110 VAC fittings with 6 A DP MCB backup.1 Nos. indicating lamp on each incomer feeder for indicating the status of feeder with 6A DP MCB back up.MANUAL / AUTO SYNCRONIZING + AMF PANEL(PLC CONTROL PANEL)1 No. 630 KVA TransformerBus Bars1sets of 1000 AmpsTPN Aluminium Bus Bars of suitable length. Bus bars shall be colour coded and insulated by heat shrinkable sleeves & clip on shrouds for joints. Bus-Bars should be sized for a current carrying capacity of 1.0A/ sqmm.1 nos. TVSS suitable for 1000A bus barsOutgoing FeedersEach Outgoing ACB/MCCB with standard protections shall be provided with the following :1 Sets of 3 Nos. phase indicating lamps suitable for 230 V/AC fittings with individually 6 A TP MCB back up.All outgoing feeders shall be provided with ON/OFF,Trip indicating lamps with 6 A DP MCB protection1 Nos. multi function meter with required CTs / PTs 3 Nos. phase indicating lamps suitable for 110 VAC fittings with 6 A DP MCB backup.400 A FP 25kA MCCB -02 Nos.100 A FP 25kA MCCB -10 Nos.63 A FP MCB 10 KA C CURVE -08 Nos40 A FP MCB 10 KA C CURVE -02 Nos32 A FP MCB 10 KA C CURVE -06 Nos25 A SP MCB 10 KA C CURVE -03 NosSupply, installation, testing & commissioning of Main Panel as described as aboveand as per specification complete in all respects.[NON CSR] 61 Earthing 62 Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI 63 Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP. 64 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP. 65 Supplying and erecting annealed bare copper wireof high purity of required sizesused forearthing onwall with necessarycopperclampsfixedon wall/cable/conduitwithscrews complete. 66 LT Cables (Aluminium) 67 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 68 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 69 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 70 LT Cables (Copper) 71 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 72 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 73 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 74 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 75 Supplying, erecting & terminating 1CX10 Sq mm Cu. Flexible Cable erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification 76 Cable Tray 77 Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. 78 Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware. 79 Raceways 80 Supply and installation of single or multi compartment GI raceway of cross section given below laid in floor complete as specified. a) Raceway b) All bends, joints, supports, end plates couplers earth conductivity. i. 50 x 32 Single compartment 81 Supply and installation of single or multi compartment GI raceway of cross section given below laid in floor complete as specified. a) Raceway b) All bends, joints, supports, end plates couplers earth conductivity. ii. 100 x 32 Double compartment 82 Supply and installation of single or multi compartment GI raceway of cross section given below laid in floor complete as specified. a) Raceway b) All bends, joints, supports, end plates couplers earth conductivity. iii. 150 x 32 Double compartment 83 Supply and installation of single or multi compartment GI raceway of cross section given below laid in floor complete as specified. a) Raceway b) All bends, joints, supports, end plates couplers earth conductivity. iv. 225 x 32 Triple compartment 84 Supply and installation of single or multi compartment GI raceway of cross section given below laid in floor complete as specified. a) Raceway b) All bends, joints, supports, end plates couplers earth conductivity. v.300x 32 Triple compartment 85 Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. 86 Supply and installation of single or multi compartment GI junction box of cross section given below with tile cover, laid in floor or above false ceiling complete as specified i. 150 x 150 x 65 - 90mm with metal cover 87 Supply and installation of single or multi compartment GI junction box of cross section given below with tile cover, laid in floor or above false ceiling complete as specified ii.225 x 225 x 65 - 90mm with metal cover 88 Supply and installation of single or multi compartment GI junction box of cross section given below with tile cover, laid in floor or above false ceiling complete as specified iii. 300 x 300 x 65 - 90mm with metal cover