}

Urgent Repairing And Replacement Of Faulty Compound Light Installation And Rewiring Of Generator Building At Dr.H.C. Mukherjee Memorial Health School, Hooghly-West Bengal

Government Departments has published Urgent Repairing And Replacement Of Faulty Compound Light Installation And Rewiring Of Generator Building At Dr.H.C. Mukherjee Memorial Health School. Submission Date for this Tender is 15-11-2024. Storage Chests and Cabinets and Trunks Tenders in Hooghly West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

46051426
Urgent Repairing And Replacement Of Faulty Compound Light Installation And Rewiring Of Generator Building At Dr.H.C. Mukherjee Memorial Health School
Open Tender
Indian
West Bengal
Hooghly
15-11-2024

Tender Documents

Tender Details

Urgent Repairing And Replacement Of Faulty Compound Light Installation And Rewiring Of Generator Building At Dr.H.C. Mukherjee Memorial Health School- 1 S & Fixing of 70W HPSV Lamp (SON - T)(make-Philips) 2 S & Fixing of 150W HPSV Lamp (SON - T)(make-Philips) 3 S &Fixing of 250W HPSV Lamp (SON - T)(make-Philips) 4 S & Fixing of 250W HPSV Ballast(make-Philips) 5 S & Fixing of 150W HPSV Ballast(make-Philips) 6 S & Fixing of 70W HPSV Ballast(make-Philips) 7 S & Fixing of 70 W/150W /250W Ignitor(make-Philips) 8 S & Delivery of1.5 sqmm. Cu. Wire.(make-finolex/KEI/Havells) 9 S & Delivery ofPVC insulation Tape (Steel Grip Red-Yellow-Blue-Black/Green) 10 Supply and Fixing of 240V, 70 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Crompton Geaves-Cat no.- CRP-409-70-57-SL-GL-NSG or equivalent make of Philips/Bajaj//wipro/Magik) on existing MS Pipe/Mini Pole as per direction of E.I.C.[NS] 11 Supply and Fixing of 240V, 45 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection (Crompton Geaves-Cat no.CRP-409-45-57-SL-GL-NSG or equivalent make of Philips/Bajaj//wipro/Magik) on existing MS Pipe/Mini Pole as per direction of E.I.C.[NS] 12 Supply and fixing of 150W LED Flood light(Make-Crompton Geaves-Cat no.-LFTN-150-CDL/60M or equivalent of Philips) 13 S/F Stainless Steel water proof looping cable box of size 200x150x100mm having hinged top Cover with rubber gasket lining, railway type mechanical locking anangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 16 A SPMCB unit, one NL on porcelain insulator etc. and housing the same on pole above 5ft from ground level by necessary pole clamp . [NS] 14 S & D 1 phase 230V,MF-1 Starter with over load relay for compound light(Make: L & T , MF-1 cat No :SS97227OOCO or equivalent as approved by EIC) [NS] 15 Fixing only starters (for motor control) on flatiron frame for Direct on Line starter for motor (upto 5 HP)[7(a)/C-1] 16 Supply of4/3.5/2 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Polycab/Havells as approved E.I.C] [NS] 17 2 Core 10 Sq. mm 18 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 19 2 Core 10 Sq. mm 20 Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 21 2 Core 10 Sq. mm 22 Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed[ 1(a)/ F- 2 ] 23 Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting[2(a)/ F- 1 ] 24 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish 25 Avg run 8 Mtr [2(c)/ E-4 ] 26 Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Keytype switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish 27 on board [4(a)/E-15] 28 Supplying and fixing PVC Rigid Conduit FR [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works 29 20 mm size[ 7(a)/ E- 16 ] 30 25 mm size[ 7(b)/ E- 16 ] 31 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire(Brand approved by E.I.C) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. 32 2x(2.5 sqmm) + 1x(1.5 sqmm)[ 1(s) / E-9 ] For 16 A Plug Point 33 2x (6 sqmm) + 1x (4 sqmm) [ 1(y) / E- 9 ]for SPNDBs 34 S & F solderless Copper socket by crimping of Copper wires. 35 2.5 sq mm [9(i) / F-5] 36 4 sq mm[9(ii) / F-5] 37 6 sq mm [9(iii) / F-5] 38 Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS 39 175 x 100 x 65 [11(c)/E-4 ,13(c)/E-5] 40 Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making bhousing for switch by cutting bakelite/perspex cover and making necessary connections as required.[14(a) / E-5] 41 Supply & Fixing 240 V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required[14(b) / E-5] 42 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connectionswith PVC wire and earth continuity wire etc.[15(a) / E-5] 43 Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combinedplug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc..[15(b) / E-5] 44 Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cuttingbakelite/perspex top cover incl. making necy. connections etc.[18(a)/E-6] 45 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 46 2+8 Way [ Make - Legrand/Siemens/L&T as approved by E.I.C).[ 13 / D- 9 & D-10 ] 47 Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ] 48 40 A DP [ 6 / D- 5 ] 49 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ] 50 6-32 SP[ 7 / D- 6] 51 Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube [NS] 52 Twin fittings [Philips make Cat No. TMC-501 P2xT-LED 22W P3242 or equivalent make CG / Bajaj / Wipro/Mazik] incl. 2 no. 18W Master LED Tube 53 Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent make CG / Bajaj / Wipro/Mazik] incl. 1 no. 18W Master LED Tube 54 Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [ 22/D-13 ] 55 Supply of 14 W LED bulb(Bajaj/CG/Philips/wipro) on existing batten holder. [NS] 56 Supplying & Fixing of LED bulk head light fitting(Make-Crompton LBHP-10-CDL/Philips/Wipro) 57 Fixing only single/twin LED Batten light fitting complete with all accessories Directly on wall/ceiling as per GS.[ 14d/C-2 ] 58 Fixing only lamp[ 11/C-2 ] 59 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level[By TATA-Medium GI pipe] [2(a)/G-1]. 60 Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1] 61 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2] 62 Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS 63 No.-4 SWG [5(a)(i)/G-2] 64 No.-10 SWG [5(a)(iv)/G-2] 65 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required[4(a)/G-2] 66 AddGST 18 % 67 Add labour Cess 1%

Key Value

Document Fees
Refer document
EMD
INR 4017.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail