Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-11-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-11-2024 |
| Sl. No. | Item Description |
| 1 | Taking down ceiling fan of any make 1200/1400 mm sweep from site for repairing after dismantling its blades complete allas specified and as directed. |
| 2 | Taking down Exhaust fans/wall mounting fans of any make and any size from site for repairing after dismantling its legs and blades complete allas specified and as directed. |
| 3 | Repairing of ceiling fan of any make, 1200 mm/1400 mm sweep dismantling its parts cleaning properly, rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petti items such as split pins, assembling and testing after fixing of fan blades, refixing at site and connecting complete allas specified and as directed. |
| 4 | Repairing of Exhaust fan of any make 300/250 mm sweep dismantling its parts cleaning properly rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petti items such as split pins, cleaning of fan body and its blade by cleaning agent assembling and testing after fixing of fan blades, refixing at site and connecting complete allas specified and as directed. |
| 5 | Repairing of Exhaust fan of any make 380 mm sweep dismantling its parts cleaning properly rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing replacing petti items such as split pins, cleaning of fan body and its blade by cleaning agent assembling and testing after fixing of fan blades, refixing at site and connecting complete allas specified and as directed. |
| 6 | Repairing of exhaust fan of any make 450 mm sweep dismantling its parts, cleaning properly, rewinding with super copper enamelled wire suitable gauge, varnishing, oiling and greasing, replacing petti items such as split pins, cleaning of fan body and its blade by cleaning agent assembling and testing after fixing of fan blades refixing at site and connecting complete allas specified and as directed. |
| 7 | Overhauling of ceiling fan any size and make, dismantling parts, properly cleaning/removing old existing grease oil and removing old paint from blades and body including down rods complete.Applying new oil grease, varnishing of winding, cleaning dust, rust and applying one coat white enamel paint over a coat of steel primer,assembling and refixing at site complete allas specified and as directed. |
| 8 | Overhauling of Exhaust fans any size and make, dismantling parts properly cleaning/removing old existing grease oil and removing old paint from blades.Applying new oil grease, varnishing of winding, cleaning dust, rust& applying one coat grey enamel paint, assembling and refixing at site complete allas specified and as directed.Note for item 3 to 7 :-Worn out/damaged parts such as canopy, rubber bush, capacitors, and Gun metal bushes, ball bearing shall be measured and paid separately as supply only under relevant items of Sch \"A\". |
| 9 | Repairing of cabin/padestal/wall mounted fan of any make 380 to 400 mm sweep dismantling its parts, cleaning properly, rewinding with super enameled copper wire suitable gauge, varnishing, oiling and greasing, replacing petti items such as split pins, cleaning of fan body and its balde by cleaning agent painting the blades, body and base with one coat existing colour systhetic enamel paint over a coat of steel primer and assembling, testing after fixing of fan blade refixing at site and connecting complete allas specified and as directed. |
| 10 | Supply only ceiling fan canopy suitable to 15 mm dia rod with fixing nuts and bolts complete allas specified and as directed. |
| 11 | Supply only gun metal bush suitable for 1200mm/1400 mm sweep ceiling fan of any make complete allas specified and as directed. |
| 12 | Supply only gun metal bush for exhaust fan of any size/make/sweep complete allas specified and as directed. |
| 13 | Supply only ball bearing of size 6201complete allas specified and as directed. |
| 14 | Supply only ball bearing of size 6202 complete allas specified and as directed. |
| 15 | Supply only ball bearing of size 6203 complete allas specified and as directed. |
| 16 | Supply only ball bearing of size 6204 complete allas specified and as directed. |
| 17 | Supply only capacitor 3.15 mfd (Make : Asian/Epcos/Usha) complete allas specified and as directed. |
| 18 | Supply only capacitor 4 mfd. (Make : Asian/Epcos/Usha) complete allas specified and as directed. |
| 19 | Supply and fix in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete allas specified and as directed. |
| 20 | Supply and fix exhaust fan shaft suitable for 250/300/380/450 mm sweep complete allas specified and as directed. |
| 21 | M&L for preparing surfaces by removing/cleaning dust & depositeld materials and applying one coat of white enamelled paint to fan blades, body and down rod of ceiling fans at existing position without removing from site complete allas specified and as directed. |
| 22 | Supply and fix in repairs ceiling fan clamps of heavy duty as per sample including nut, bolts, spring washers, cross pin and rubber reel etc complete allas specified and as directed. |
| 23 | Supply and fixing fan blade of 1200 /1400 mm sweep to match with the existing fan complete allas specified and as directed. |
| 24 | Supply and fix MS seanless steel tube down rod for hanging the fan including cutting the false ceiling and making good the false ceiling after fixing of fan down rod complete allas specified and as directed. |
| 25 | Supply and fix exhaust fan louvers/shutter metallic suitable for 300/250 mm sweep complete allas specified and as directed. |
| 26 | Supply and fix exhaust fan louvers/shutter metallic suitable for 380 mm sweep complete all as specified and as directed. |
| 27 | Supply and fix exhaust fan louvers/shutter metallic suitable for 450 mm sweep complete all as specified and as directed. |
| 28 | Supply and fix in replacement ceiling fan 1200 mm sweep complete with (REMOTE),down rod canopy and blades of size 1200 mm sweep,Energy efficient,5 star rated complete all as specified and as directed. |
| 29 | Supply and fix in replacement ceiling fan 1400 mm sweep complete with (REMOTE),down rod canopy and blades of size 1200 mm sweep,Energy efficient,5 star rated complete all as specified and as directed. |
| 30 | Supply and fix in replacement Exhaust fan 300 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , complete all as specified and as directed. |
| 31 | Supply and fix in replacement Exhaust fan 380 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , complete all as specified and as directed. |
| 32 | Supply and fix in replacement Exhaust fan 450 mm sweep complete with brackets frame and blades, metalic body heavy duty with louvers suitable for 240V 50 Hz supply , complete all as specified and as directed. |
| 33 | Supply and fix ventilating exhaust fan single phase, plastic body 200 mm sweep, complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed. complete all as specified and as directed. |
| 34 | S & Fplasic body air fan / ventilator with louver 250mm sweepand grouting withnut , bolts & Fastenaron the wall and make good the disturbed surface and electric connection with 1.5 Sqmmthree core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and as directed. |
| 35 | Supply and fix BLDC fan \"PCB\" suitable to fix on 1400 mm/1200 mm BLDC ceiling fan of make Havells/Crompton complete all as specified and as directed. |
| 36 | Supply and fix BLDC fan \"Universal Remote\" suitable to match with 1400 mm/1200 mm BLDC ceiling fan of make Havells/Crompton complete all as specified and as directed. |
| 37 | S & F in replacement enviroment friendly recess/pendent mounting LED flat panel 2\"x2\" fabricated CRCA sheet steel housing cool white with high efficient LEDs & glare free opal diffuser (34 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V includingall accessaries complete all as specified and as directed. |
| 38 | Supply and fixing in replacement microprocessor based three phase electronic tamper proof energy meter of rating 10 to 40 Amps,AC 415 Volts, 50 Hz covered with toughened glass coverwith optical comunication port confirming to IS 13779 complete all as specified and as directed. |
| 39 | Supply and fixing in replacement microprocessor based single phase electronic tamper proof energy meter of rating 10 to 40 Amps,AC 240 Volts, 50 Hz covered with toughened glass coverwith optical comunication port confirming to IS 13779 complete all as specified and as directed. |
| 40 | S & F in repair sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 4 sq mm single core of FRLS PVC insulated unsheathed cable,1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and as directed. |
| 41 | S & F in repair sub main wiring for circuit of size 4 sq mm 2 core (FRLS) alongwith earth wire of 2.5 sq mm single core of FRLS PVC insulated unsheathed cable,1100 volts grade with multistranded copper conductor in existing PVC conduit complete all as specified and as directed. |
| 42 | S&F in replacement of single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB 10-32 complete all as specified and as directed. |
| 43 | Supply and fix in replacement double door TPN DBs 4 wayof powder coated DB\"s suitable for MCB\"s fitted with bus bar,Neutral link,Earth bar and Din ral & DB\"s will be fitted concealed in wall / surface as per site required complete all as specified and as directed. |
| 44 | S & F in replacement with MCB TPN 32amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed. |
| 45 | S & F in replacement with MCB TPN 50 to 63 amps 10 KA ,c-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed. |
| 46 | Supply and fixing in repair TPN DB\"s 4 way vertical type 415 V, double door suitable for housing of 100/63 Amps MCCB as main incomingcomplete all as specified and as directed. |
| 47 | S & F MCCB 100/63 Amps capacity, 3 pole, 25 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 4 way TPN DB complete all as specified and as directed. |
| 48 | Supply and fixing in repair ofEarthing to panel with galvanised steel earth plate electrode60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point includingexcavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed. |
| 49 | M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G Istrip 25x 4 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 40 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete. |
| 50 | M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G Iwire 4 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 15 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete all as specified and as directed. |
| 51 | Supply and fixing in repair LED post top 40/45 watts complete with suitable size of GI pipe suitable size of required length duly grouted in existing locations including , PVC copper wire 1.5 sq mm 3 core of required lenght (upto 3 mtrs) complete all as specified and directed. |
| 52 | Supply and fixing in repair LED bollard fitting 10wcomplete with suitable size of nuts/bolts for fixing arrangement and provision of suitable size PCC foundation for fixing of bollard fitting etc complete all as specified and as directed. |
| 53 | Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and as directed. |
| 54 | M & L for replacement of concealed point wiring complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia,with MS terminal boxes (not less than 1.6mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dollywith3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multistranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified andas directed for the followings :- |
| 55 | One light / fan point controlled by one way switch . |
| 56 | One 5 Amp socket outleton independent board. |
| 57 | One5 Amp socket outlet on same board. |
| 58 | One bell/buzzer point controlled by one bell push. |
| 59 | One light point controlled by two 2-way switch |
| 60 | All as per above item No 54 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed,FRLS cable for 15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified andas directed. |
| 61 | M&L for replacement of point wiring in casing caping/PVC conduit (not less 20 mm) on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathedFRLS cable of 1.5 sqmm (nominal area) with multistranded copper conductor single core 1100 volts grade in and includingPVC conduit , with mild steel terminal boxes (not less than 1.6 mm thick ) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dollywith3mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm multistranded copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etccomplete all as specified and as directed for the followings :- |
| 62 | One light / fan point controlled by one way switch. |
| 63 | One 5 Amp socket outleton independent board. |
| 64 | One5 Amp socket outlet on same board. |
| 65 | One bell/buzzer point controlled by one bell push. |
| 66 | One light point controlled by two 2-way switch. |
| 67 | All as per above item no 56 here in befor but using 2.5sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified andas directed. |
| 68 | M & L for replacement ofpoint wiring in existing conduit (PVC/Steel) surface / concealed includingexisting MS Terminal boxeswith1.5 sqmm FRLS PVC insulatedmulti stranded copper conductor cablesingle core 1100 volts gradeand one run of 1.5 sqmm multistranded copper conductor cable of green colouras continuous earth wireand laminated sheet cover 3 mm thick on terminal box duly fixed including taking out old u/s wire of any type and size complete all as specified and as directed for the followings :- |
| 69 | One light / fan point controlled by one way switch |
| 70 | One 5 Amp socket outleton independent board. |
| 71 | One 5 Amp socket outleton same board. |
| 72 | One bell/buzzer point controlled by one bell push |
| 73 | Ditto all as per above item No 58 but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant ( FRLS ) cable for15 Amp socket outleton independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed. |
| 74 | S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and as directed. |
| 75 | S&Fin replacement switch piano type15 Amps one way ISI Marked complete all as specified and as directed. |
| 76 | S&F in replacement socket outlet 3 pin 5 Amps flush type complete all as specified and as directed. |
| 77 | S&F in replacement socket outlet 2-in-1, 3 pin 5 amp and 15 amps complete all as specified and as directed. |
| 78 | S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and as directed. |
| 79 | S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and as directed. |
| 80 | S&F in replacement switch 6 amps modular type one one way complete all as specified and as directed. |
| 81 | S&F in replacement switch 16 amps modular type one one way complete all as specified and as directed. |
| 82 | S&F in replacement modular 2 Module electronic fan regulator Step type complete all as specified and as directed. |
| 83 | S&F in replacement bell push flush type 5 amp one way ISI Marked complete all as specified and as directed. |
| 84 | S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and as directed. |
| 85 | S&F in replacementBell, DING DONG AC 230 Volts single pole type complete all as specified and as directed. |
| 86 | S & F in replacement ofLamp holder bakalite type with back plate suitable for batten fittingscomplete all as specified and as directed. |
| 87 | S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed. |
| 88 | Supply & Fixing in repairincluding making connection testing and commissioning ofnew MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and as directed. Note: The make of MCCB shall be L &T , GE , Havells, crompton, C & S or any other make as per the makein the existing plannel board or exactly suitable to the existing frame size. In case only one particular make is procuring by the bidder necceasry alteration required to fix the same at no extra cost shall be done by the bidder . |
| 89 | Supply and fixing RGB flood light 50 watts IP 65 with colour changing remote complete all as specified and as directed. |
| 90 | Supply and fixing metal clad plug and socket AC plug 20 Amps 2 Pole + E, 230 Volts AC complete all as specified and as directed. |
| 91 | Supply and fixing AC female socket 20 A, 2 Pole + E, 230 volts AC complete all as specified and as directed. |
| 92 | Supply , laying & testing in repair forXLPEinsulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointingwith suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 4core complete all as specified and as directed. |
| 93 | All as per item No. 78 but Size 25 Sqmm X 4 core. |
| 94 | All as per item No. 78 but Size 50 Sqmm X 3.5 core. |
| 95 | All as per item No. 78 but Size 95 Sqmm X 3.5 core. |
| 96 | All as per item No. 78 but Size 120 Sqmm X 3.5 core. |
| 97 | Excavation of soft/loose soil in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified and as directed. |
| 98 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and as directed. |
| 99 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 100 | M & Lfor dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable all as specified and directed . |
| 101 | M & L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and as directed. |
| 102 | S&F in replacement for white cover plate with frame, 3 module all as specified and as directed. |
| 103 | S&F in replacement for white cover plate with frame, 6 module all as specified and as directed. |
| 104 | S&F in replacement for white cover plate with frame, 8 module all as specified and as directed. |
| 105 | S&F in replacement for white cover plate with frame, 12 module all as specified and as directed. |
| 106 | S&F in replacement of enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser including all accessaries all as specified and as directed. |
| 107 | S&F in replacement of enviroment friendly indoor decorative 10 Watt LED mirror light polycarbonate Battenwith opal diffuser including all accessaries all as specified and as directed. |
| 108 | S&F RCBOs for earth leakage, overload & short circuit protection double pole, 40 Amps, 100 mA complete all as specified and as directed. |
| 109 | Supply and fix \"Anti Sucide Fan down rod\", 250 mm length, approved colour, suitable fo fit any make/brand of ceiling fan complete all as specified and as directed. |
| 110 | Supply and fixing wall fan 400 mm sweep, 240 Volts, AC, 3 speed, pull cord for speed and oscillaation, aluminium blades for high air thurst complete suitable clamps for wall mounting complete all as specified and as directed. |
| 111 | Supply and fixing wall fan 400 mm sweep, 240 Volts, AC, 3 speed,metal blades for high air thurst and metal body heavy duty complete all as specified and as directed. |
| 112 | Disconnecting and taking down of Geysers (water heater) of capacity 25/ 50 Ltrshorizontal/vertical of any make/model from existing position and dismantling of parts i.e.bottom plate, Top cover, water assembly thernmostat, heating elements,inner tank ,glass wool,Pressure release, inlet and outlet valves etc.complete andreassembling and refixing in same position after descaling desludging andcleaning with suitable cleaning agent and materials and washing withfresh water and repair and replacment of defective/unserviceable componentscomplete all as spaciifed and as directed. Note: The rate quoted shall include the minors repairs and replacment of minor parts i.e. screw nuts, bolts washers and patch work etc .However the major componentsincoperatedherein after shall be paid under respective items. |
| 113 | S&F in repair of required qty thermowool/PUF insulation as existing for Geysers of 50 Ltrs capacity complete all as specified and as directed. |
| 114 | All as per item No 99.00 here-in-before, 25 ltrs capacity. |
| 115 | S&F in repair of waterGEYSER ( syphon) assemblywith rubber gaskit suitable for 50 Ltrs Geysers all as per exisiting shape and size complete all as specified and as directed. |
| 116 | All as per item No101.00 here-in-before, 25 ltrs capacity suitable for horizontal & vertical six hole. |
| 117 | S&F in replacement of inner stainless steel containernot less than 0.7 mm thickfor 50 Ltrs Geysers complete all as specified and as directed. |
| 118 | All as per item No 103.00 here-in-before, 25 ltrs capacity. |
| 119 | M&L for replacement ofouter cover duly spray paintedas per existingtogeyserof50 Ltr capacity complete all as specified and as directed. |
| 120 | All as per item No105.00 here-in-before, 25 ltrs capacity. |
| 121 | S&F in replacement of indicators red/green colour as per existing size and type complete all as specified and as directed. |
| 122 | S&F in replacement of heating element triangle/cup type of 2 KW, 240 V , 50 HZ, suitablesize and shape with Washer as per existing duly ISI marked to geysers of any make and of capacity 25/50 Litres complete all as specified and as directed. |
| 123 | All as per item No 108.00 here-in-before, but horizontal type. |
| 124 | All as per item No 108.00 here-in-before, but with round plate 6 Hole. |
| 125 | S&F in replacement of heating element triangle/cup type of 1.5 KW, 240 V , 50 HZ, suitablesize and shape with Washer as per existing duly ISI marked to geysers of any make and of capacity 25/50 Litres complete all as specified and as directed. |
| 126 | S&F in replacement of PVC connection suitable for use in hot water / cold water with brass connector duly threaded internallyon both ends of size 18”(45 cm) long complete all as specified and as directed. |
| 127 | All as per item No 112.00 here-in-before, but 60cm long. |
| 128 | S&F in replacement of thermostat any type and model suitable to the existing one range 0 to 100 C temperature for geysers of any make horizontal / vertical of capacity 25 Ltr to 50 Ltrs complete all as specified and as directed. |
| 129 | S&F in replacement of capillarythermostatsuitable to the existing one range 0 to 100 C temperature for geysers of any make horizontal / vertical of capacity 25 Ltr to 50 Ltrs complete all as specified and as directed. |
| 130 | Supply and fixing Indication lamp for 25/50 Ltr capacity Geyser complete all as specified and as directed. |
| 131 | Supply and fixing Fusible plug (safety plug)melting at 95-100 degree centigrade complete all as specified and as directed. |
| 132 | M&L in replacement of pressure release valve any type as existing suitable for geysers any make horizontal / vertical of capacity 25 to 50 Ltrs complete all as specified and as directed |
| 133 | M&L for Painting to Geyser 25 ltr any make horizonal /vertical with two coat of synthetic enamel white paint with spray gun or with brush after proprerly cleaning the surfaces complete all as specified and as directed. |
| 134 | All as per item No 119.00 here-in-before, cap 50 ltrs. |
| 135 | M &Lfor Grouting of bolts by making holes in wall ofsize upto 15 mmx100mm and fixing of Geyser ofcapacity 25 to 50 Ltrs on wallwith nuts and washers complete all as specified and as directed. |
| 136 | S&F in repair single pole and neutral enclosure witha two pin earth plug and socket with one single pole MCB of capacity 15/20Amps complete all as specified and as directed. |
| 137 | M&L in repair conection lead 2.5 mtr length 3 core PVC insulated and sheathed multi stranded copper conductor of 2.5 Sqmm 1100 Volt gradecomplete all as specified and as directed. |
| 138 | S & F in repair GI tubingmedium gradewith all fitting confirming and dulyI S I marked,fixedon wall / ceilings or laid in floor of20 mm bore complete all as specified and as directed. |
| 139 | All as per item No 124.00 here-in-before, bor 15 mm. |
| 140 | S & F in repairstop valve cast copper alloy screwed down , high presure with crutch or butterfly handle screwed both ends for iron pipe ,20 mm Bore fancy type chromium platedcomplete all as specified and as directed. |
| 141 | All as per item No 126.00 here-in-before, bor 15 mm. |
| 142 | S&F in repair ofMCB single pole 6 to 32 Amps 240 V,10KA, complete all as specified and as directed. |
| 143 | S & F in replacement of solar water heater complete with tank, panel, heat pipe, reflector, frame & support of size (Flat type) 212cm x 108 cm x 8 mm for solar water heater of 100 Ltrs capacity complete incuding taking out existingcomplete all as specified and as directed. |
| 144 | S & F in replacement repair solar glass of solar panel of size (Flat type) 212cm x 108 cm x 8 mm for solar water heater of 100 Ltrs capacity complete all as specified and as directed. |
| 145 | M & L for replacement of round type steel water tank with outer cover of aluminium sheet as per existing gauge and model of solar water heater of 100 Ltrs capacity including necessary insulation of cold/ Hot water tanks, pipe line and making necessary connection complete all as specified and as directed. |
| 146 | M & L forworn out insulation ofhot waterGI pipe of dia 15 mm of solar water heater system complete all as specified and as directed. |
| 147 | S&F in replacement of Heating Element3.0 KW, 240V, 50Hz ISI mark suitable for dual power solar water heater 100Ltrs capacity, complete all as specified and as directed. |
| 148 | S&F in repair ofmetal cladPlug 20 Amps 2 pinand earth & socket ,240 V,complete all as specified and as directed. |
| 149 | Maintenace & servicing of DG set of capacity 20 KVA to 30 KVA, (Periodical) \"B\"check including replacement of fuel filter/oil filter/Air filter and minor parts if required as per manufacturer recommendation, replacement of Engine oil, coolant, etc all as directed & comprising of checking of following:-(i)Fuel supply system of Engine.(ii)Lubricant system of the engine.(iii)Battery charging system of the DG set.(iv)Control panel of the DG set.(v) Air filter(vi) water Separator(vii) Radiator cleaning with chemical agent(Viii) Exhaust Mainfold |
| 150 | S & F in replacementmain contactor 63A , 3 polesuitable for AMF panel complete all as specified and as directed. |
| 151 | S & F in replacement Current Transformer as requiredfor the Gen/ AMF panel any capacity as per existing complete all as specified and as directed. |
| 152 | S & F in replacementA series electronic timers on/off delayfunction model A1D1 / AIDCS ,12 VDC, with time range 0.3S to 30Min. Make EAPL or equivalent suitable forAMF panel complete all as specified and as directed. |
| 153 | M&L for Repairing the self Dynamo 12/24 Volts afterremoving from the Gen set of any capacity and transporting to an authorised sevice centre complete all as specified and as directed. |
| 154 | Supply and replacing in repair Automatic Voltage regulator (AVR) of suitable size complete all as specified and as directed. |
| 155 | S&F Battery Charger of capacity 12V suitable for AMF Panel complete all as specified and as directed. |
| 156 | M&L for complete AMF panel rewiring by using 2.5 sqmm copper conductor /control cable of 20/30 KVA capacityDG Set of any Make/any type all as specified and as directed. |
| 157 | M&L for taking downthe existingunserviceable cables from trenches of any size all as specified and as directed. |
| 158 | Supply, laying, jointing and testing XLPE insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 4 core X 10 Sqmm and laid in trenches/ducts/pipe or on poles with GI wire to restraint sagging complete all as specified and as directed. |
| 159 | Supply, laying, jointing and testing XLPE insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 3.5 core X 70 Sqmm and laid in trenches/ducts /pipe or on poles complete all as specified and as directed. |
| 160 | S&F DC power pack of 7 AH having AC output range 90V to 270V and DC output 24V with switch for on & off , AC & DC fuse, indicator LED showing AC supply, overload, battery charging etc. complete all as specified and as directed. |
| 161 | M&L for Boring of holes under road, pavement, hard standing in true horizontal position by manual means1.5 metre deep and not exceeding 50 metre for RCC pipe of 150mm and making the road/hard standing good as per existing complete all as specified and as directed. |
| 162 | Supply and fixing LED Solar street light fitting 36 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and as directed. |
| 163 | Taking down of street light junction box complete all as specified and as directed. |
| 164 | S & F in replacement of hot pressedmoulded SMC boxes with hinged door fixing of size 35cm x 25cmx14 cm (internal dimension) with MS clamp 25 x 3mm made to shape with necessry nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers incl MCB SP 6 amps and making incoming and outging connections by taking out loops of cable of any size incl necesary excavations and other civil works complete all as specified and as directed. |
| 165 | Taking down of street light fitting/ Flood light fittingcomplete all as specified and as directed. |
| 166 | S&F LED high beam long distance focus light fitting 150 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 167 | Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 168 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 169 | Supply and fixing LED street light fitting 100 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 170 | S&F illuminated Radium glow/LED square light sign board (size of the board 3ft x 3ft) with digital type multi colourfabricated from SS sheet 3mm thick finish on internal and external surfaces having canopy both side with fixing arrangement on SS pipe 50mm dia. support including provision of PCC 1:2:4 type B-1 for grouting the same, excav and earth workcomplete all as specified and as directed. Note :-Writing words/symbols/sketches of size and colour to be decidedas per user\"s requirement & deemed to be included in quoted rate |
| 171 | M&L for GI Tubing ( medium grade,ISI ) mark 32 mm dia ,1.5 mtr long light grade , bend to shape for street light fitting bracket , with 2x pair of MS clamp of suitable length of size 40 mmx5 mm of MS flat ironwith nuts,bolts and washer including two coats of synthetic enamel aluminium paint over a coat of red oxide ,clamps fixed on pole or grouted on wall complete all as specified and as directed. |
| 172 | S&F in replacement of GI steel tube light grade 20 mm dia fixed to pole for carrying the wire from junction box to street light / security light fitting with all necessary connection for fitting complete all as specified and as directed. |
| 173 | S&F Electronic timer 240V AC, adjustment time 6-60Sec complete all as specified and as directed. |
| 174 | M&L for painting of steel tubular pole including cable protection pipe and all iron parts of 9/11 mtr long pole complete with 2 coats of aluminium paint after cleaning all rust and dust and preparing surface with wire brush and including strips of yellow and black colour of synthetic enamel paint up to the height of 1.5 mtr from the bottm of the pole and marking the Pole No with black paint at the height of 02 Mtrs from the bottom of the Pole complete all as specified and as directed. |
| 175 | M&L HFFR PVC insulate industrial cables 1100 volt grade 2 core 1.5 sqmm including one run of earth wie of 1.5 sqmm complete all as specified and as directed. |
| 176 | M&L for taking down light fittings from pole/high mast/building structure to ground testing all the components /parts wiring etc. identifyingand replacing the defective componentselectronic driver, diodes, lense, IC\"s, connector, connection wire/cables etc.including refixingto its original position complete all as specified and as directed. Note : The rate against the above mentioned items is deemedfor cost of labour and allied expenses only. |
| 177 | M&L for Taking up or down DI water mains 150 mm dia bore (including all fitting) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 178 | M&L for Taking up or down DI water mains 100 mm dia bore (including all fitting) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 179 | Supplying, laying in trenches/ pedestals, testing and commissioning DI pipes 150 mm dia bore with spigot & socket end centrifugally castclass B, in requisite length and conforming to IS complete all as specified and as directed. |
| 180 | Supplying, laying in trenches/ pedestals, testing and commissioning DI pipes 100 mm dia bore with spigot & socket end centrifugally castclass B, in requisite length and conforming to IS complete all as specified and as directed. |
| 181 | Supply ,fixing ,testingand commissionngin replacement of double flanged non-rising stem type cast iron sluice valve suitable for 100 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6duly drilled holes for fixing of nuts and bolts ,stem made of high tensile brass ISI marked and conforming to IS including rubber gasket ,nuts,bolts and washer complete all as specified and as directed. |
| 182 | Supply ,fixing ,testingand commissionngin replacement of double flanged non-rising stem type cast iron sluice valve suitable for 150 mm dia bore pipe with hand wheel and suitable for pressure rating of PN :1.6duly drilled holes for fixing of nuts and bolts ,stem made of high tensile brass ISI marked and conforming to IS including rubber gasket ,nuts,bolts and washer complete all as specified and as directed. |
| 183 | Supply, laying and jointingheavy duty CI Bends in replacements (any type, radius and angle ), Tapers any type,( straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, Y junction, Double branch, Cross (all sockets or socket and spigot or all flanged or one end flanged and other ends spigot /socketed), Collars, Caps and Plugs completeand conforming to IS :and upto 150 mm bore complete all as specified and as directed. |
| 184 | M&L for run lead joints for 150mm dia of cast iron Spun pipes/fittings including burning out old joints and recovering leadcomplete all as specified and as directed. |
| 185 | M&L for run lead joints for 100mm dia of cast iron Spun pipes/fittings including burning out old joints and recovering leadcomplete all as specified and as directed. |
| 186 | M&L for Taking up or down steel tubing and connections, including cleaning for refixing or removal to store exixting GI tubing 80 mm bore any type complete all as specified and as directed. |
| 187 | Supply, laying, testing & jointing ofGI tubing80 mm dia bore medium grade conforming to IS : 1239with all fittings laid in trenchescomplete all as specified and as directed. |
| 188 | M&L for dewatering cleaning of overhead reservoir of 50,000 Gallons capacity with high pressure water jet to remove all masses,algae,dirt and removal of dirty water along with sludgeand disposal of the same to a safe distance as directed and including scrubbing of internal surfaces and cleaning of walls,floors & ceilingwhich dislodges the layers of dirt, funges struck on its surface and writing the date of cleaning and due date complete all as specified and as directed.NOTE :- Rate shall be inclusive for all T&P/material required for dewatering and nothing will be paid extra on this account. |
| 189 | Physio-chemical bacteriological testing of water from the approved institute / lab as per IS : 10500 - 1991 including collection of water sample and submitting the same with institute / lab complete all as specified and as directed. |
| 190 | M&L for Lifting of submersible pump set 12.5 HP from borewell including coloumn pipe and submersible cable and lowering ofpump in bore well after repair of pump complete all as specified and as directed. Note: cost of disconnecting pipe from header / cables from panel shall be deemed to be included in the quoted rate. |
| 191 | M&L for Rewinding of stator ofmotor of pump set with same gauge of winding wire with insulating material after removal of burnt winding complete all as specified and as directed. |
| 192 | M&L for Cutting existing steel tubing for alterations or additions and finding leakage of laid pipes of dia 40 or 50 mm complete all as specified and as directed. |
| 193 | S&F DOL stater suitable for 12.5 HP Submersible motors including necessary electric connections complete all as specified and as directed. |
| 194 | M&L for Dismantling/taking down Split type AC 1.5/2 Ton from site, opening, cleaning all dust with the help of air blower including cleaning of condenser and evaporator coil with Soap solution, removing the dust with the help of wire brush, repairing & proper fixing of wiring including thimbles and replacement of air filter Nylon and reinstalling AC in the same location both unit outdoor/indoor unit complete and testing on full load etc complete all as specified and as directed. |
| 195 | M&L for Maintainence and servicing of water cooler,cooling cap 40 litre /storage cap 80 litrecleaning of cooling/condensing coil ,oilingof condenser fan motor, cleaning of drain pipetesting for smooth functioningcomplete all as specified and as directed. |
| 196 | M&L for Maintenance and servicing ofDeepfreezer any capacity by cleaning of cooling/candensing coil , cleaning ofcomplete refrigerator and testing for smooth functioningcomplete all as specified and as directed. |
| 197 | M&L for detection of refrigerent leakage from split type AC, repair of cooling coil/condensing coil for minor leakage if any , flushing of system and gas charging in the system up to requiredqty , and sealing /closing of charging valveof split type AC/window type AC cap 1.50/2.0 TR complete all as specified and as directed. |
| 198 | M&L for detection of refrigerent leakage from Deep freezerof any capacity , repair of cooling coil/condensing coil for minor leakage if any , flushing of system and gas charging in the system up to requiredqty , and sealing /closing of charging valveof Refrigerator complete all as specified and as directed. |
| 199 | S&F inreplecement newsealed compressor rotory typesuitable for 1.5 Ton capacitysingle phase, 230 Volt, 50 Hz split type airconditoner in and including refillingrefrigerant gas R-22 filling up to required pressure and testing complete all as specified and as directed. |
| 200 | S&F inreplecement newsealed compressor reciprocating typesuitable for 1.5 Ton capacitysingle phase, 230 Volt, 50 Hz split type airconditioner in and including refillingrefrigerant gas R-22 filling up to required pressure and testing complete all as specified and as directed. |
| 201 | M&L for Cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/R-134a/R-410/R-32 with anti moisture substance and replacement of filter along with rectification of leakage system in the split type AC of capacity1.5/2 TR)Ton including installation at site and testing on full load etc complete all as specified and as directed. |
| 202 | S&F Evaporator coil assembly complete suitable for Split type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and as directed. |
| 203 | S&F Condensing coil assembly complete suitable for Split type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and as directed. |
| 204 | M&L for repair to voltage stabilizer of capacity 04/05 KVA single phase including replacement of circuit plate, starting relay, voltmeter, fuse terminal box with fuse carrier, rewinding the main transformer with copper wire of existing size and repair / replacement time delay relay (1-2 Min) built-in type designed for low cut off 140/160 volt, high cut off 260/280 volt on single phase, 50 cycle AC supply etc complete all as specified and as directed. |
| 205 | S&F in replacement Oscilation motor with swing blade strip for indoor unit of split AC 1.5/2.0 TR capacity same specification /make as per existing one complete all as specified and as directed. |
| 206 | S&F in replacement LCD Digital type AC timer for cyclic operation of 02 any type of Air Conditioner with displaying AC 1/AC 2 on indication & 1 to 24 hours programmable to take load upto 2 Ton split AC with auto/manual facility at site complete all as specified and as directed. |
| 207 | M &L fordismantling/taking down of existing Split type AC of cap 2.0/1.5 TR complete with Indoor/Outdoor unit from existing location with all Electric Connection and all refrigerant Pipes and matching the existing disturbed surface area, Including Refixing/Re-Installation of Split type AC Shifted to new location on suitable wall places complete all as specified and as directed.(Refrigerant Recharging gas, Insulation of Copper tubes, copper tubes paid & measured seprate under respective item) |
| 208 | Supply and fix spare parts for split type AC complete all as specified and as directed:- |
| 209 | Running Capacitor 36mfd-- . ( MAKE: Tesla / Tibcon ) |
| 210 | Starting Capacitor80-100 mfd.MAKE: Tesla / Tibcon ) |
| 211 | PCBof indoor unit suitable for Invertor ACsplit type AC 1.5 TR |
| 212 | PCB of outdoor unit suitable for Invertor AC split type AC 1.5 TR |
| 213 | Fan blade for split ACof 1.5/2.0 TR. |
| 214 | Remote suitable for split AC any make/type. |
| 215 | Thermostat suitable for split AC |
| 216 | Insulation to refrigerant pipes of split ACs any make & type complete with suitable size for suction and discharge refrigerant pipes including necessary clamps etc. complete all as specified and as directed. |
| 217 | Supply and fix copper tubing flexible of dia 1/2\" complete in and including soldering and thermalinsulation taping to copper tubing neatlycomplete all as specified and as directed. |
| 218 | Supply and fix copper tubing flexible of dia 1/4\" complete in and including insulation taping to copper tubing neatlycomplete all as specified and as directed. |
| 219 | Material and labour for Drain pipe rigid and flexible 20mm dia with clamps uf suitable sizeas per site reuirementcomplete all as specified and as directed. |
| 220 | Material and Labour forrelaysuitable for split AC 1.5 TR capacitycomplete all as specified and as directed. |
| 221 | Material and Labour for blower motor foroutdoorunitsuitable for split AC 1.5 TR capacitycomplete all as specified and as directed. |
| 222 | M&L for grouting of fastener (screw type ) ,washer ,bolt in wall for geysercomplete all as specified and as directed. |
| 223 | Supply and fix in replacement electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and as directed. |
| 224 | S & F in replacement of Exhaust fan blades of steel (Set of three blades) suitable for 450 mm sweepduly painted with synthetic enemelled paint fixed in replacement complete all as specified and as directed. |
| 225 | S & F in replacement Exhaust fan blades of steel (Set of three blades) suitable for 300 mm sweepduly painted with synthetic enemelled paint fixed in replacement complete all as specified and as directed. |
| 226 | M & L for suitable size of bolts, nuts,body screws, GM bushes and safety pin/split pins for any type/size/make and model ofexhaust fan as required , fixed in replacement , complete all as specified and as directed. |
| 227 | S & F in repair Down rod 20 mm dia, GI tubing medium grade45 cm to 60 cm long as require fixed in replacement at site complete all as specified and as directed. |
| 228 | S&F in replacementamp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 229 | SP 5 To 32 AMP Cat Part No. TSPB6-32 complete all as specified and as directed. |
| 230 | SPN 32 AMP Cat Part No. TSPN32-63 complete all as specified and as directed. |
| 231 | M&L for Taking up or down steel tubing and connections, including cleaning for refixing or removal to store exixting GI tubing 25 mm bore any type complete all as specified and as directed. |
| 232 | M&L for Taking up or down steel tubing and connections, including cleaning for refixing or removal to store exixting GI tubing 50 mm bore any type complete all as specified and as directed. |
| 233 | Supply, laying, testing & jointing ofGI tubing50 mm dia bore medium grade conforming to IS : 1239with all fittings laid in trenchescomplete all as specified and as directed. |
| 234 | Supply, laying, testing & jointing ofGI tubing25 mm dia bore medium grade conforming to IS : 1239with all fittings laid in trenchescomplete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy