}

Tender For Procurement Of Fire Fighting Equipments For Cisf In Htps Kasimpur , Cylindrical Shape, Upright Operation Type Having Capacity 9Ltr. Water Type (Gas Cartridge) Fire Extinguisher As Per Is: 15683 / 2006 And Amendment 2018 With Isi Marked Shall Be, kasimpur-Uttar Pradesh

Boards / Undertakings / PSU has published Tender For Procurement Of Fire Fighting Equipments For Cisf In Htps Kasimpur , Cylindrical Shape, Upright Operation Type Having Capacity 9Ltr. Water Type (Gas Cartridge) Fire Extinguisher As Per Is: 15683 / 2006 And Amendment 2018 With Isi Marked Shall Be. Submission Date for this Tender is 26-11-2024. Machine Tools Tenders in kasimpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

46032401
Tender For Procurement Of Fire Fighting Equipments For Cisf In Htps Kasimpur , Cylindrical Shape, Upright Operation Type Having Capacity 9Ltr. Water Type (Gas Cartridge) Fire Extinguisher As Per Is: 15683 / 2006 And Amendment 2018 With Isi Marked Shall Be
Open Tender
Indian
Uttar Pradesh
Kasimpur
26-11-2024

Tender Documents

Tender Details

Tender For Procurement Of Fire Fighting Equipments For Cisf In Htps Kasimpur , Cylindrical Shape, Upright Operation Type Having Capacity 9Ltr. Water Type (Gas Cartridge) Fire Extinguisher As Per Is: 15683 / 2006 And Amendment 2018 With Isi Marked Shall Be Complete With Following:-#1) The Material For The Construction Of Siphon Tube, Ap Assembly And Safety Clip Shall Be Of Stainless Steel (Is: 6913).#2) Gas Cartridge Of 40 Gm Capacity Shall Be As Per Is: 4947/1985 With Isi Marked And Content Shall Be As Per Is: 15222-2002.#3) The Inner Surface Of The Extinguisher Shall Be Coated With Xy Polyester Powder Coating For Anti-Corrosion Treatment And Shall Pass All Test Mention In Is: 15683 / 2006 And Amendment No. 1 December 2008.#4) The Manufacture Shall Have The Following Valid License:-#A) Certificate For Manufacturing From Bis, B) Certi Ate For Isi Mark From Bis##5)Extinguisher Should Meet All Requirement And Test As Per Is 15683 / 2006 (Reaffirmed 2018).#6) A Spare Filled Gas Cartridge Should Be Provided With Each Fire Extinguisher# , Cylindrical Shape, Upright Operation Type Having Capacity 9 Ltr. Mechanical Foam Type (Gas Cartridge) Fire Extinguisher As Per Is: 15683 / 2006 And Amendment 2018 With Isi Marked Shall Be Complete With Following:-#1) The Material For The Construction Of S Hon Tube, Cap Assembly And Safety Clip Shall Be Of Stainless Steel (Is: 6913).#2) Refill Pack Of 270 Ml Afff 3 % Shall Be As Per Is # 4989/1985 And It Should Be Provided Separately In Pvc Cans.#3) Gas Cartridge Of 60 Gm Capacity Shall Be As Per Is: 4947/1 With Isi Marked And Content Shall Be As Per Is: 15222-2002.#4) One Spare Gas Cartridge With Each Extinguisher Should Also Be Provided.#5) The Inner Surface Of The Extinguisher Shall Be Coated With Epoxy Polyester Powder Coating For Anti Corrosion Treatment And Shall Pass All Test Mention In Is: 15683 / 2006 And Amendment 2018.#6) A Spare Filled Gas Cartridge Should Be Provided With Each Fire Extinguisher#7) The Manufacture Shall Have The Following Valid License:-#A) Certificate For Manufacturing From Bis# B Tificate For Isi Mark From Bis# Extinguisher Should Meet All Requirement And Test As Per Is 15683 / 2006 And Amendment 2018# , Cylindrical Shape, Upright Operation Type, Having Capacity 06 Kg., Dry Chemical Powder (Gas Cartridge) Type Fire Extinguisher As Per Is: 15683 / 2006 And Amendment 2018 With Isi Marked Shall Be Complete With Following:-#1) The Material For The Construction Of Siphon Tube, Cap Assembly, And Safety Clip Shall Be Of Stainless Steel (Is: 6913).#2) Inner Container Shall Be M S Sheet Confirming To Grade Any Of Is 513, Is 3074 Or Is 3601.#3) Refill Pack Of 90% Mono Ammonium Phosphate Base D.C.P. Of 06 Kg Pack Shal E As Per Is # 14609-1999 And It Should Be Provided In Hermetically Sealed Moisture Proof Plastic Bags.#4) Gas Cartridge Shall Be As Per Is: 4947/1985 With Isi Marked And Content Shall Be As Per Is 15222-2002. One Spare Gas Cartridge Should Also Be Provide 5) The Inner Surface Of The Extinguisher Shall Be Coated With Epoxy Polyester Powder Coating For Anti-Corrosion Treatment And Shall Pass All Test Mention In Is: - 15683 / 2006 And Amendment 2018#6) The Manufacture Shall Have The Valid License For The Cert Ication Of Isi Mark From Bis.#7) A Spare Filled Gas Cartridge Should Be Provided With Each Fire Extinguisherextinguisher Should Meet All Requirement And Test As Per Is 15683## , Specification Of 50 Kg Dcp Trolley Mounted Fire Extinguisher#1. Trolley Mounted Dcp Fire Extinguisher Is: 16018:2012 (Reaffirmed 2018) 50 Kg Capacity Having Abc Powder (As Per Is- 14609-1999) With Gun Metal Cap.#2. Extinguishing Media- Abc Powder (As Per - 14609-1999)#3. Propellant- Co2 Cylinder Conforming To Is-7285 (Cap. 2Kg) As Expellant Media. #4. Effective Discharge - 85% -100%#5. Pressure Requirements-# - Test Pressure (Pt)- 1.43 X P Ms But Not Less Than 2 Mpa (20Bar )#- Burst Pressure (Pb)-2.7 X P Ms Ot Less Than 5.5 Mpa (55Bar)#6. Copper Tubing Or High Pressure Hose - Copper Tubing Shall Conform To Bursting Pressure Of 275 Kgf/Cm2 Or Wire Braided High Pressure Hose As Per Is 14933:2001.#7. Discharge Hose:- Discharge Hose Shall Be Of Braided Rubber O Vc Of Nominal Bore 19 Mm Diameter Fitted With Not Less Than 5Mtr. The Hose Shall Have Bursting Pressure Of Not Less Than 50 Kgf/Cm2#8. General Operating Performance Requirements -#A) Hydraulic Test:-The Extinguisher Shall Be Tested To An Internal Hydraulic Pressure Of3.0 Mn/M2 (30 Kgf/Cm). The Test Pressure Shall Be Held For A Minimum Period Of Two And A Half Minutes During The Test, It Shall Not Show Any Sign Of Leakage)Bursting Test:-In Case Of Hydraulic Burst Test, Failure Shall Not Occur At A Press , Specification Of Co2 Extinguishers 4.5 Kg Capacity: ##1. Isi Marked Co2extinguisher 4.5 Kg Capacity Shall Conform To Is 15683:2006 & 2018#2. Co2 Used In The Extinguisher Shall Conform To Is 15222.#3. The Maximum Filling Density Shall Not Exceed 0.75Kg/L.#4 L Be Capable Of Operating Reliably With The Temperature Ranges Specified By Is 15683-2006.#5. Minimum Effective Discharge Time And Bulk Release Of Discharge Shall Comply With Is 15683-2006. #6. Shall Have A Mechanical Resistance Complying With Is 15683-200 . Shall Have Been Passed Internal And External Corrosion Resistance Test As Per Is 15683-2006. #8. Shall Have Been Passed Tapping Test As Per Is 15683-2006. #9. Should Not Retain 10% Of The Initial Charge After Discharge.#10. Shall Have Been Passed Electric Conductivity Test As Per Is 15683-2006.#11. Steel Body Should Conform To Is 7285 And The Base Of The Body Should Be Of Concave Shape.#12. The Minimum Burst Pressure Shall Be 2.7 X Maximum Service Pressure.#13. Shall Pass Volumetric Expansion Test As Per Is 83-2006.#14. Discharge Tubes And Discharge Horn Should Pass Burst Pressure Test As Per Is 15683-2006. The# Discharge Horn Shall Withstand A Crushing Force Of 25 Kg. #15. Color Of The Extinguisher Shall Conform To Shade No 538 Of Is 5 And Paint Shall Conform

Key Value

Document Fees
INR 2360 /-
EMD
INR 42000.0 /-
Tender Value
INR 21.07 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail