Bids Are Invited For 82340014790 15 EA POWER SOCKET CABINET CONSISTING OF 01 NO. 415 V, 3PH, WITH 125 AMP TPN SWITCH SUITABLE FOR WALL MOUNTING AS DETAILED BELOW:- DETAILS OF ENCLOSURE: 1) SIZE OF ENCLOSURE: 1000(H) X 800(W) X 400(D)MM (+-5% VARIATION ACCEPATABLE IN DIMENSIONS) 2) MATERIAL: SHEET STEEL 3) THICKNESS: ENCLOSURE - 1.5MM, DOOR - 2MM, MOUNTING PLATE - 3MM 4) SINGLE DOOR 5) SURFACE FINISH: ENCLOSURE AND DOOR - DIPCOAT PRIMED POWDER COATED ON THE OUTSIDE IN TEXTURE RAL 7035, MOUNTING PLATE: ZINC PASSIVATED/POWDER COATED 6) PROTECTION: IP55 7) DOOR OPENING: 180 DEG. AND CAN BE INTERCHANGEABLE TO LEFT OR RIGHT SIDE 8) EARTHING PROVISION: AT BOTH SIDES OF ENCLOSURE 9) CABLE ENTRY: FROM BOTTOM THROUGH GLAND PLATE 10) DOOR LOCK: HEAVY DUTY TYPE 11) MOUNTING BRACKET FOR WALL AND EYE BOLT FOR LIFTING COMPONENTS TO BE MOUNTED WITH IDENTIFICATION TAG IN THE CABINET AS FOLLOWS:- ----------------------------------------------------------------- -- A. MCCB, 125A, 3PH, TPN OF 50KA SHORT CIRCUIT CAPACITY AND EARTH FAULT PROTECTION WITH SIDE OPERATED EXTERNAL HANDLE AND PADLOCK FACILITY AND DOOR DEFEAT MECHANISM. B. TRANSFORMER, 415V/240V SINGLE PHASE, 3KVA C. TRANSFORMER, 415V/24V SINGLE PHASE, 400VA D. POWER SOCKET FOR WELDING, 125A, 3P+N+E MOUNTED ON DOOR SHALL BE WIRED THROUGH 63A, 10KA, 300mA, 4 POLE RCCB E. POWER SOCKET, 20A, 1P+N+E, 240V MOUNTED ON DOOR SHALL BE WIRED FROM 415/240V TRANSFORMER THROUGH 20A, 10KA, DP, C-CURVE MCB F. POWER SOCKET, 20A, 1P+N+E, 24V MOUNTED ON DOOR SHALL BE WIRED FROM 415/24V TRANSFORMER THROUGH 20A, 10KA, DP, C-CURVE MCB G. PLUG OR TOP FOR EACH RATING POWER SOCKET AS ABOVE. H. TRANSFORMER DUTY MCB OF PROPER RATING SHALL BE PROVIDED IN PRIMARY AS WELL AS SECONDARY SIDE OF EACH TRANSFORMER. I. A DISTRIBUTION BUS OF 240V PH AND NEUTRAL SHALL BE PROVIDED FROM WHERE 3NOS. 240V OUTGOING SUPPLY WILL BE TAPPED AND TERMINATED AT TERMINAL BLOCKS AFTER ROUTED THROUGH 10A DP MCB IN EACH INDIVIDUAL CIRCUIT. J. 2NOS. OF 3PH OUT-GOING POWER SHALL ALSO BE PROVIDED AT TERMINAL BLOCKS WITH 3POLE MCB 16A. K. INDICATION LAMPS FOR R/Y/B PHASE ON DOOR. L. DIGITAL MULTIFUNCTION METER HAVING ENERGY METER RECORDING FEATURE M. BOLTED TYPE TERMINAL BLOCKS OF SUITABLE SIZE FOR INCOMING CABLE SIZE 3.5X120 SQ.MM. N. UNIVERSAL POLYAMIDE TERMINAL BLOCKS OF 6SQ.MM. SIZE FOR OTHER CABLES. PANEL COMPONENTS: ALL THE PANEL COMPOPNENTS AND SWITCHGEARS USED IN THE PANEL SHALL BE FROM REPUTED MANUFACTURERS AND MUST COMPLY TO IEC-60898, IEC-60947 AND IEC 60309-1 STANDARDS NOTE:- ---------- 1. SCOPE OF VENDOR INCLUDES CABINET WITH COMPLETE INTERNAL WIRING 2. CABLE POWER SOCKET FOR WELDING SHALL BE OF METAL CLAD SHROUDED TYPE COMPLYING SAFETY FEATURES. 3. THE POWER SOCKETS ARE REQUIRED TO BE INSTALLED SEPARATELY IN A FIXED PLATE WITH NUT AND BOLT ARRANGEMENT WHICH IS INDEPENDENT OF THE FRONT DOOR. THE LOCATION OF ALL THE SOCKETS SHALL BE IN THE BOTTOM OF THE PANEL IN THE FRONT SECTION I.E. BELOW FRONT DOOR. 4. GA DRAWING WITH BILL OF MATERIALS SHALL BE FURNISHED ALONG WITH QUOTATION. 5. VENDOR TO SUBMIT IP TEST CERTIFICATE ISSUED BY NABL ACRREDITED LABORATORY ALONG WITH THE OFFER FOR TECHNICAL SCRUTINY. 6. MATERIAL SHALL BE UNDER WARRANTY FOR A PERIOF OF 12 MONTHS FROM THE DATE OF INSTALLATION OR 18 MONTHS FROM THE DATE OF SUPPLY, WHICHEVER IS EARLIER, FOR POOR WORKMANSHIP OR POOR QUALITY OF MATERIALS. 7. DELIVERY PERIOD SHALL BE WITHIN 5 MONTHS FROM THE DATE OF PLACEMENT OF PURCHASE ORDER. 2 26654802540 20 EA INDOOR TYPE MAIN DISTRIBUTION BOARD WITH PROVISION OF SINGLE INCOMMER MCB OF 63A TPN & 8 WAY OUTGOING MCB OF 10A SP.PRE-WIRED, READY TO USE COMPLETE MAIN DISTRIBUTION BOARD AS PER IS:8623 HAVING FOLLOWING SPECIFICATION : 1) 63 AMP., 4P, 10 KA B CURVE MCB 01 NO AS INCOMER 2) 10 AMP,SP, 10 KA B CURVE MCB 08 NOS AS OUTGOING WITH REQUIRED INTERNAL WIRING BY 4 SQ.MM COPPER CABLE EQUALLY DISTRIBUTED ON THREE PHASES. 3) THE BOX SHOULD BE OF METALLIC INDUSTRIAL TYPE , IP-43 HAVING DOUBLE DOOR COVER PROTECTION , FRONT DOOR SHOULD HAVE LOCKING ARRANGEMENT.THE PANEL MUST BE OF POWDER COATED PAINT. 4) DIN-RAIL MOUNTED SUITABLE SIZE TERMINAL BLOCKS FOR CONNECTION OF ALUMINIUM CONDUCTORS AS IN COMING AND OUTGOING MUST BE AT BOTTOM OF JUNCTION BOX WITH PRE-WIRED UPTO INCOMER AND OUTGOING MCBs. 5) IT SHOULD BE PROVIDED WITH ADEQUATE SIZE INSULATED COPPER BUSBAR,NEUTRAL BAR AND EARTH BAR AND INTERNAL CONNECTIONS THEREOF. 6) BOX SHOULD BE SUITABLE FOR WALL MOUNTING WITH MINIMUM 04 NOS. EXTENDED BRACKET WITH 8MM HOLE 7) BOX SHOULD HAVE TOP & BOTTOM REMOVABE GLAND PLATE OF SUITABLE SIZE MADE OUT OF 2MM CRCA STEEL. 8) THERE SHOULD BE PROVISION OF 02 EARTHING STUDS//STRIPS ON THE DISTRIBUTION BOARD FOR FACILITATING EARTHING CONNECTION. NOTE: 1. ALL LIVE PARTS SHOULD BE SEPARETED BY FRP SHEET TO EACH OTHER. 2. PROVISION OF SUITABLE EARTH CONNECTION FOR OUTGOING CABLES MUST BE AVAILABLE WITHIN THE PANEL. 3. SWITCH GEARS USED MUST BE OF REPUTED MANUFACTURERS AND MUST CONFORM TO IEC-60898 AND IEC-60947 STANDARDS. 4. PARTY HAS TO SUBMIT DETAILED GA DRAWING, ELECTRICAL DRAWING ALONG WITH BILL OF MATERIALS ALONG WITH THE OFFER WHICH ARE REQUIRED TO BE APPROVED BY NALCO BEFORE MANUFACTURING. SUBMISSION OF OFFER WITHOUT DRAWINGS WILL BE LIABLE FOR TECHNICAL REJECTION. 5. DELIVERY PERIOD SHALL BE WITHIN 5 MONTHS FROM THE DATE OF PLACEMENT OF PURCHASE ORDER 6.VENDOR TO SUBMIT IP TEST CERTIFICATE ISSUED BY NABL ACRREDITED LABORATORY ALONG WITH THE OFFER FOR TECHNICAL SCRUTINY. 3 82644306380 20 EA INDOOR TYPE MAIN DISTRIBUTION BOARD WITH PROVISION OF SINGLE INCOMMER MCB OF 32A TPN & 12 WAY OUTGOING MCB OF 6A SP.PREWIRED, READY TO USE COMPLETE MAIN DISTRIBUTION BOARD AS PER IS:8623 HAVING FOLLOWING SPECIFICATION : 1) 32 AMP., 4P, 10 KA B CURVE MCB 01 NO. AS INCOMER 2) 06 AMP DP 10 KA B CURVE MCB 12 NOS. AS OUTGOING WITH REQUIRED INTERNAL WIRING BY 4 SQ.MM COPPER CABLE EQUALLY DISTRIBUTED ON THREE PHASES. 3) THE BOX SHOULD BE OF METALLIC INDUSTRIAL TYPE , IP-43 HAVING DOUBLE DOOR COVER PROTECTION , FRONT DOOR SHOULD HAVE LOCKING ARRANGEMENT.THE PANEL MUST BE OF POWDER COATED PAINT. 4) DIN-RAIL MOUNTED SUITABLE SIZE TERMINAL BLOCKS FOR CONNECTION OF ALUMINIUM CONDUCTORS AS IN COMING AND OUTGOING MUST BE AT BOTTOM OF JUNCTION BOX WITH PRE-WIRED UPTO INCOMER AND OUTGOING MCBs. 5) IT SHOULD BE PROVIDED WITH ADEQUATE SIZE INSULATED COPPER BUSBAR,NEUTRAL BAR AND EARTH BAR AND INTERNAL CONNECTIONS THEREOF. 6) BOX SHOULD BE SUITABLE FOR WALL MOUNTING WITH MINIMUM 04 NOS. EXTENDED BRACKET WITH 8MM HOLE 7) BOX SHOULD HAVE TOP & BOTTOM REMOVABE GLAND PLATE OF SUITABLE SIZE MADE OUT OF 2MM CRCA STEEL. 8) THERE SHOULD BE PROVISION OF 02 EARTHING STUDS//STRIPS ON THE DISTRIBUTION BOARD FOR FACILITATING EARTHING CONNECTION. NOTE: 1. ALL LIVE PARTS SHOULD BE SEPARETED BY FRP SHEET TO EACH OTHER. 2. PROVISION OF SUITABLE EARTH CONNECTION FOR OUTGOING CABLES MUST BE AVAILABLE WITHIN THE PANEL. 3. SWITCH GEARS USED MUST BE OF REPUTED MANUFACTURERS AND MUST CONFORM TO IEC-60898 AND IEC-60947 STANDARDS. 4. PARTY HAS TO SUBMIT DETAILED GA DRAWING, ELECTRICAL DRAWING ALONG WITH BILL OF MATERIALS ALONG WITH THE OFFER WHICH ARE REQUIRED TO BE APPROVED BY NALCO BEFORE MANUFACTURING. SUBMISSION OF OFFER WITHOUT DRAWINGS WILL BE LIABLE FOR TECHNICAL REJECTION. 5. DELIVERY PERIOD SHALL BE WITHIN 5 MONTHS FROM THE DATE OF PLACEMENT OF PURCHASE ORDER 6.VENDOR TO SUBMIT IP TEST CERTIFICATE ISSUED BY NABL ACRREDITED LABORATORY ALONG WITH THE OFFER FOR TECHNICAL SCRUTINY. 4 82711073690 25 EA INDOOR TYPE LDB HAVING SINGLE INCOMMER MCB OF 63A AND 18 WAY OUTGOING PROVISION.PRE-WIRED, READY TO USE COMPLETE LIGHTING DISTRIBUTION BOARD AS PER IS:8623 HAVING FOLLOWING SPECIFICATION: 1) 63 AMP., 4P, 10 KA B CURVE MCB 01 NO. AS INCOMER 2) 16 AMP, SP 10 KA B CURVE MCB 06 NOS. AND 10 AMP, SP 10 KA B CURVE MCB 12 NOS. AS OUTGOING. WITH REQUIRED INTERNAL WIRING BY 4 SQ.MM COPPER CABLE EQUALLY DISTRIBUTED ON THREE PHASES. 3) 10 SQ.MM 2 POLE TERMINAL BLOCKS 18 SETS ARE REQUIRED AS OUTGOING FEEDERS WITH COMPLETE INTERNAL WIRING. 4) THE BOX SHOULD BE OF METALLIC INDUSTRIAL TYPE, IP-43 HAVING DOUBLE DOOR COVER PROTECTION , FRONT DOOR SHOULD HAVE LOCKING ARRANGEMENT.THE LDB MUST BE OF POWDER COATED PAINT. 5) DIN-RAIL MOUNTED SUITABLE SIZE TERMINAL BLOCKS FOR CONNECTION OF ALUMINIUM CONDUCTORS AS IN COMING AND OUTGOING MUST BE AT BOTTOM OF JUNCTION BOX WITH PRE-WIRED UPTO INCOMER AND OUTGOING MCBs. 6) IT SHOULD BE PROVIDED WITH ADEQUATE SIZE INSULATED COPPER BUSBAR, NEUTRAL BAR AND EARTH BAR AND INTERNAL CONNECTIONS THEREOF. 7) BOX SHOULD BE SUITABLE FOR WALL MOUNTING WITH MINIMUM 04 NOS. EXTENDED BRACKET WITH 8MM HOLE 8) BOX SHOULD HAVE TOP AND BOTTOM REMOVABLE GLAND PLATE OFSUITABLE SIZE MADE OUT OF 2MM CRCA STEEL. 9) THERE SHOULD BE PROVISION OF 02 EARTHING STUDS/STRIPS ON THE DISTRIBUTION BOARD FOR FACILITATING EARTHING CONNECTION NOTE: 1. ALL LIVE PARTS SHOULD BE SEPARETED BY FRP SHEET TO EACH OTHER. 2. PROVISION OF SUITABLE EARTH CONNECTION FOR OUTGOING CABLES MUST BE AVAILABLE WITHIN THE PANEL. 3. SWITCH GEARS USED MUST BE OF REPUTED MANUFACTURERS AND MUST CONFORM TO IEC-60898 AND IEC-60947 STANDARDS. 4. PARTY HAS TO SUBMIT DETAILED GA DRAWING, ELECTRICAL DRAWING ALONG WITH BILL OF MATERIALS ALONG WITH THE OFFER WHICH ARE REQUIRED TO BE APPROVED BY NALCO BEFORE MANUFACTURING. SUBMISSION OF OFFER WITHOUT DRAWINGS WILL BE LIABLE FOR TECHNICAL REJECTION. 5. DELIVERY PERIOD SHALL BE WITHIN 5 MONTHS FROM THE DATE OF PLACEMENT OF PURCHASE ORDER 6. VENDOR TO SUBMIT IP TEST CERTIFICATE ISSUED BY NABL ACRREDITED LABORATORY ALONG WITH THE OFFER FOR TECHNICAL SCRUTINY. Total Quantity : 81