Sitc Of Silent Dg Set (As Per Cpcb 4 Plus Norms) With Amf Panel Including Providing Earthing, Concrete Foundation And Providing Shed With Profile Sheet At Fsd Ranital, Fsd Rupsa, Fsd Baripada And Fsd Keonjhar Under Fci Do Balasore For The Fy 2024-25 Sitc Of Silent Dg Set (As Per Cpcb 4 Plus Norms) With Amf Panel Including Providing Earthing, Concrete Foundation And Providing Shed With Profile Sheet At Fsd Ranital, Fsd Rupsa, Fsd Baripada And Fsd Keonjhar Under Fci Do Balasore For The Fy 2024-2 ; 1 FSD Ranital 2 Supply, Installation, Testing & Commissioning of silent type new Diesel Generator set of reputed make/ manufaturer having prime power rating of 40 KVA, 415 volt, 0.8 lagging power factor suitable for 50 HZ, 3 phase system (conforming to the norms of CPCB IV+ upto latest amendmend) comprising of 4 Stroke Liquid cooled Diesel Engine, electric start turbocharged & intercooled developing of min. 51.8 BHP at 1500 RPM, capable of taking 10 % over loading for one hour after 12 hours of continous operation coupled with self excited and self regulated, Brush less, Synchronous alternator with H class insulation in SPDP enclosure rated at 40 KVA, 415 V at 1500 RPM, 3 phase 50 HZ, A.C supply with 0.8 lagging power factor, both the engine and alternator shall be mounted on a common MS base frame in Accoustic & wheather proof enclosure on suitable C.C foundation as per manufacturer drawing & design complete with Automatic mains failure control Panel (AMF) with suitable rating MCCBs including auto/ manual by-pass, battery charger, Micro-processor based Genset controllers with display for voltages & Currents, Frequency, Genset KVA, KW, KWh, KVAr, Power Factor, Lube oil pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Emergency Stop, Battery charge condition, comprises of advanced Digital AVR for improving voltage regulation & response time, Electronic Governor, Fuel tank, Residential type silencer, AVM pads fitted on base frame, First fill of lube oil, 12V DC starting system comprising of starter motors & 1 No. 12V battery including transportation, loading and unloading of the DG set. The entire set must be warranted least of 24 months / 5000 Hrs from the date of Commissioning whichever is earlier. The agency will have to fill full tank & provide permanently multi-core control cables as required with allied accessories including laying of the same before commissioning of the DG set and also including supplyingandfixingexhaustgaspipingof suitabledia.weldedblackMS,BClasspipe conformingtoIS:3589cuttorequiredlengths andinstalledwithnecessarybends,supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50mmthickwiremesh&aluminumcladding etc., The DG set should be of reputed brand and must be approved by the Engineer-in Charge and installed as per CPWD specifications. 3 Supply of XLPE Power cable of size 4 x 35 sq.mm of 1.1 KV grade armoured Al. Cable Compulsary ISI made Confirming to IS : 7098/ Pat -I / 88 with amendment no Iof reputed make as required. 4 Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.. 5 Providing and fixing 25 mm X 5mm G.I Strip in 40 mm dia G.I pipe from earth electrode electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling as required. 6 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 7 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. upto 35 Sq.mm 8 Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE powercable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle) upto 35 Sq.mm (Clamped with 25X3 mm MS Flat Clamp 9 Credit Item for Old working Single Phase DG Set of capacity 7.5 KVA. Year of Manufacturing - 2017 of make Mahindra 10 Providing and fixing precoated galvanised iron profile sheets size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 11 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) 12 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 13 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 14 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansin foundation trenches or drain(not exceeding 1.5 m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms foralllift including getting out the excavated soiland disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kind of soil 15 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III)derived from natural sources: 8 graded stone aggregate 40 mm nominal size from natural sources) 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5.3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) 17 FSD Rupsa 18 Supply, Installation, Testing & Commissioning of silent type new Diesel Generator set of reputed make/ manufaturer having prime power rating of 25 KVA, 415 volt, 0.8 lagging power factor suitable for 50 HZ, 3 phase system (conforming to the norms of CPCB IV+ upto latest amendmend) comprising of 4 Stroke Liquid cooled Diesel Engine, electric start turbocharged & intercooled developing of min. 35.1 BHP at 1500 RPM, capable of taking 10 % over loading for one hour after 12 hours of continous operation coupled with self excited and self regulated, Brush less, Synchronous alternator with H class insulation in SPDP enclosure rated at 25 KVA, 415 V at 1500 RPM, 3 phase 50 HZ, A.C supply with 0.8 lagging power factor, both the engine and alternator shall be mounted on a common MS base frame in Accoustic & wheather proof enclosure on suitable C.C foundation as per manufacturer drawing & design complete with Automatic mains failure control Panel (AMF) with suitable rating MCCBs including auto/ manual by-pass, battery charger, Micro-processor based Genset controllers with display for voltages & Currents, Frequency, Genset KVA, KW, KWh, KVAr, Power Factor, Lube oil pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Emergency Stop, Battery charge condition, comprises of advanced Digital AVR for improving voltage regulation & response time, Electronic Governor, Fuel tank, Residential type silencer, AVM pads fitted on base frame, First fill of lube oil, 12V DC starting system comprising of starter motors & 1 No. 12V battery including transportation, loading and unloading of the DG set. The entire set must be warranted least of 24 months / 5000 Hrs from the date of Commissioning whichever is earlier. The agency will have to fill full tank & provide permanently multi-core control cables as required with allied accessories including laying of the same before commissioning of the DG set and also including supplyingandfixingexhaustgaspipingof suitabledia.weldedblackMS,BClasspipe conformingtoIS:3589cuttorequiredlengths andinstalledwithnecessarybends,supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50mmthickwiremesh&aluminumcladding etc., The DG set should be of reputed brand and must be approved by the Engineer-in Charge and installed as per CPWD specifications. 19 Supply of XLPE Power cable of size 4x16 sq.mm of 1.1 KV grade armoured Al. Cable Compulsary ISI made Confirming to IS : 7098/ Pat -I / 88 with amendment no Iof reputed makeas required. 20 Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 21 Providing and fixing 25 mm X 5mm G.I Strip in 40 mm dia G.I pipe from earth electrode electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling as required. 22 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 23 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. upto 35 Sq.mm 24 Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE powercable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle) upto 35 Sq.mm (clamped with 1mm thick saddle) 25 Credit Item for Old working Single Phase DG Set of capacity 7.5 KVA. Year of Manufacturing - 2017 of make Mahindra 26 Providing and fixing precoated galvanised iron profile sheets size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 27 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) 28 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 29 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 30 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansin foundation trenches or drain(not exceeding 1.5 m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms foralllift including getting out the excavated soiland disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kind of soil 31 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III)derived from natural sources: 8 graded stone aggregate 40 mm nominal size from natural sources) 32 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5.3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) 33 FSD Baripada 34 Supply, Installation, Testing & Commissioning of silent type new Diesel Generator set of reputed make/ manufaturer having prime power rating of 25 KVA, 415 volt, 0.8 lagging power factor suitable for 50 HZ, 3 phase system (conforming to the norms of CPCB IV+ upto latest amendmend) comprising of 4 Stroke Liquid cooled Diesel Engine, electric start turbocharged & intercooled developing of min. 35.1 BHP at 1500 RPM, capable of taking 10 % over loading for one hour after 12 hours of continous operation coupled with self excited and self regulated, Brush less, Synchronous alternator with H class insulation in SPDP enclosure rated at 25 KVA, 415 V at 1500 RPM, 3 phase 50 HZ, A.C supply with 0.8 lagging power factor, both the engine and alternator shall be mounted on a common MS base frame in Accoustic & wheather proof enclosure on suitable C.C foundation as per manufacturer drawing & design complete with Automatic mains failure control Panel (AMF) with suitable rating MCCBs including auto/ manual by-pass, battery charger, Micro-processor based Genset controllers with display for voltages & Currents, Frequency, Genset KVA, KW, KWh, KVAr, Power Factor, Lube oil pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Emergency Stop, Battery charge condition, comprises of advanced Digital AVR for improving voltage regulation & response time, Electronic Governor, Fuel tank, Residential type silencer, AVM pads fitted on base frame, First fill of lube oil, 12V DC starting system comprising of starter motors & 1 No. 12V battery including transportation, loading and unloading of the DG set. The entire set must be warranted least of 24 months / 5000 Hrs from the date of Commissioning whichever is earlier. The agency will have to fill full tank & provide permanently multi-core control cables as required with allied accessories including laying of the same before commissioning of the DG set and also including supplyingandfixingexhaustgaspipingof suitabledia.weldedblackMS,BClasspipe conformingtoIS:3589cuttorequiredlengths andinstalledwithnecessarybends,supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50mmthickwiremesh&aluminumcladding etc., The DG set should be of reputed brand and must be approved by the Engineer-in Charge and installed as per CPWD specifications. 35 Supply of XLPE Power cable of size 4x16 sq.mm of 1.1 KV grade armoured Al. Cable Compulsary ISI made Confirming to IS : 7098/ Pat -I / 88 with amendment no Iof reputed makeas required. 36 Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 37 Providing and fixing 25 mm X 5mm G.I Strip in 40 mm dia G.I pipe from earth electrode electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling as required. 38 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 39 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. upto 35 Sq.mm 40 Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE powercable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle) upto 35 Sq.mm (clamped with 1mm thick saddle) 41 Credit Item for Old working Single Phase DG Set of capacity 7.5 KVA. Year of Manufacturing - 2017 of make Mahindra 42 Providing and fixing precoated galvanised iron profile sheets size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 43 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) 44 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 45 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 46 Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansin foundation trenches or drain(not exceeding 1.5 m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms foralllift including getting out the excavated soiland disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kind of soil 47 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III)derived from natural sources: 8 graded stone aggregate 40 mm nominal size from natural sources) 48 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5.3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) 49 FSD Keonjhar 50 Supply, Installation, Testing & Commissioning of silent type new Diesel Generator set of reputed make/ manufaturer having prime power rating of 20 KVA, 415 volt, 0.8 lagging power factor suitable for 50 HZ, 3 phase system (conforming to the norms of CPCB IV+ upto latest amendmend) comprising of 4 Stroke Liquid cooled Diesel Engine, electric start turbocharged & intercooled developing of min. 25.2 BHP at 1500 RPM, capable of taking 10 % over loading for one hour after 12 hours of continous operation coupled with self excited and self regulated, Brush less, Synchronous alternator with H class insulation in SPDP enclosure rated at 20 KVA, 415 V at 1500 RPM, 3 phase 50 HZ, A.C supply with 0.8 lagging power factor, both the engine and alternator shall be mounted on a common MS base frame in Accoustic & wheather proof enclosure on suitable C.C foundation as per manufacturer drawing & design complete with Automatic mains failure control Panel (AMF) with suitable rating MCCBs including auto/ manual by-pass, battery charger, Micro-processor based Genset controllers with display for voltages & Currents, Frequency, Genset KVA, KW, KWh, KVAr, Power Factor, Lube oil pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Emergency Stop, Battery charge condition, comprises of advanced Digital AVR for improving voltage regulation & response time, Electronic Governor, Fuel tank, Residential type silencer, AVM pads fitted on base frame, First fill of lube oil, 12V DC starting system comprising of starter motors & 1 No. 12V battery including transportation, loading and unloading of the DG set. The entire set must be warranted least of 24 months / 5000 Hrs from the date of Commissioning whichever is earlier. The agency will have to fill full tank & provide permanently multi-core control cables as required with allied accessories including laying of the same before commissioning of the DG set and also including supplyingandfixingexhaustgaspipingof suitabledia.weldedblackMS,BClasspipe conformingtoIS:3589cuttorequiredlengths andinstalledwithnecessarybends,supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50mmthickwiremesh&aluminumcladding etc., The DG set should be of reputed brand and must be approved by the Engineer-in Charge and installed as per CPWD specifications. 51 Supply of XLPE Power cable of size 4x16 sq.mm of 1.1 KV grade armoured Al. Cable Compulsary ISI made Confirming to IS : 7098/ Pat -I / 88 with amendment no Iof reputed makeas required. 52 Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 53 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 54 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 55 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. upto 35 Sq.mm 56 Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE powercable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle) upto 35 Sq.mm (clamped with 1mm thick saddle) 57 Credit Item for Old working Single Phase DG Set of capacity 7.5 KVA. Year of Manufacturing - 2017 of make Mahindra 58 Providing and fixing precoated galvanised iron profile sheets size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 59 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) 60 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 61 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 62 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5.3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)