Tender For Rovn Of Lt Feeder Panel Boxes In Domestic Area At Af Stn Hasi Mra, hasimara-West Bengal

Statutory Bodies & Commissions/Committees has published Tender For Rovn Of Lt Feeder Panel Boxes In Domestic Area At Af Stn Hasi Mra. Submission Date for this Tender is 20-11-2024. Bolts Tenders in hasimara West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

46020552
Tender For Rovn Of Lt Feeder Panel Boxes In Domestic Area At Af Stn Hasi Mra
Open Tender
Indian
West Bengal
Hasimara
20-11-2024

Tender Documents

Tender Details

Tender For Rovn Of Lt Feeder Panel Boxes In Domestic Area At Af Stn Hasi Mra; Supply, fabricating, installing, testingng and commissioning of outdoor type LT feeder pillar box of suitable size factory fabricated, cubical panel, wall/floor mounted single door, dust and vermin proof CPRI approved made out of 3.15mm thick CRCA sheet alongwith both side cable alley of width not less than 200mm each side for termination of cable with provision for top and bottom cable entry mounting on 50 x 50 x 5mm Angle iron supports at the base duly painted with synthetic enamel paint and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessories at Officer MessSub Stn & Main Guard Room Sub Stn :-INCOMING:MCCB 400 Amps, AC 4 pole 415 Volt 36 KA Breaking Capacity thermal magnetic release range 400-500A, with suitable rotary extendable handle for operation of MCCB-01 No. OUTGOING:(i) MCCB 200 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release range 200-250A, with suitable rotary extendable handle for operation - 03 Nos (ii) MCCB 63 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release range 63-80A, with suitable rotary extendable handle for operation - 02 Nos. (iii) Isolator 04 pole 80 Amp - 04 Nos(iv) MCB SPN 63 Amp C curve, 10 KA - 08 Nos.(v) Digital volt meter with all accessories for incoming-01 No.(vi) Digital Ammeter with all accessories for incoming and each outgoing- 6 Nos.(vii) Phase indicating lamp LED Type (R-Y-B) for incoming and outgoing connections- 18 Nos. 2 Supply, fabricating, installing, testingng and commissioning of outdoor type LT feeder pillar box of suitable size factory fabricated, cubical panel, wall/floor mounted single door, dust and vermin proof CPRI approved made out of 3.15mm thick CRCA sheet alongwith both side cable alley of width not less than 200mm each side for termination of cable with provision for top and bottom cable entry mounting on 50 x 50 x 5mm Angle iron supports at the base duly painted with synthetic enamel paint and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessories infront of Air men Mess, Falcon Billet, Raffale Billet :-INCOMING:MCCB 200 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release range 200-250A, with suitable rotary extendable handle for operation of MCCB-01 No. OUTGOING:(i) MCCB 160 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release range 160-200A, with suitable rotary extendable handle for operation - 02 Nos. (ii) MCCB 100 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release range 100-125A, with suitable rotary extendable handle for operation - 03 Nos. (iii) Isolator 04 pole 80 Amp - 04 Nos(iv) MCB SPN 63 Amp C curve, 10 KA - 08 Nos.(v) Digital volt meter with all accessories for incoming-01 No.(vi) Digital Ammeter with all accessories for incoming and each outgoing- 6 Nos.(vii) Phase indicating lamp LED Type (R-Y-B) for incoming and outgoing connections- 18 Nos. 3 Supply, fabricating, installing, testingng and commissioning of outdoor type LT feeder pillar box of suitable size factory fabricated, cubical panel, wall/floor mounted single door, dust and vermin proof CPRI approved made out of 3.15mm thick CRCA sheet alongwith both side cable alley of width not less than 200mm each side for termination of cable with provision for top and bottom cable entry mounting on 50 x 50 x 5mm Angle iron supports at the base duly painted with synthetic enamel paint and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessories near NCEs Qtrs & MES colony :-INCOMING:MCCB 200 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release range 200-250A, with suitable rotary extendable handle for operation of MCCB-01 No. OUTGOING:(i) MCCB 100 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release range 160-200A, with suitable rotary extendable handle for operation - 02 No.(ii) MCCB 63 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity thermal magnetic release range 100-125A, with suitable rotary extendable handle for operation - 07 Nos. (iii) Isolator 04 pole 80 Amp - 04 Nos(iv) MCB SPN 63 Amp C curve, 10 KA - 08 Nos.(v) Digital volt meter with all accessories for incoming-01 No.(vi) Digital Ammeter with all accessories for incoming and each outgoing- 10 Nos.(vii) Phase indicating lamp LED Type (R-Y-B) for incoming and outgoing connections- 30 Nos. 4 M&L for earthing complete with GI earth plate electrode 60 × 60cm × 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to existing earth leadstripby means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:3:6) type C-1 as earth pit with pre-cast RCC (1:2:4) type B-1 cover slab size 400 x 400 x 50mm reinforced with 8mm dia TMT bar, 100mm c/c both ways including one handle made of 12mm dia including providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all aroundthe earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect, including galvanised iron earth strip 25 x 4mm, protected by 40mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc. 50 mtr and necessary testing on completion, complete all as specified and as directed.Note : (i) GI strip from earthing to LT panel/Bus bar shall deemed to be included in the unit quoted rate.(ii) GI earth strip beyond 7.5 mtr shall be measured and paid seperately. 5 Supply, fabricating, installing, testing and commissioning of outdoor type LT bus bar box of size not less than 900 mm (L) x 900mm (B) x 450mm (D) of suitable size, factory fabricated, cubical panel, floor mounted double door, dust and vermin proof CPRI approved made out of 3.15 mm thick CRCA sheet mounting on 40 x 40 x 5mm angle iron supports at the base duly painted with synthetic enamel paint and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus Bar strip 40mm x 10mm for three phase 4 wire 415 volts, 50 Hz, AC supply including suitable size cable glands, lugs etc, proper arrangement for ventilation, complete all as specified and directed. 6 Taking down/out LT UG cable of any cross section and connection including bricks, GI pipes etc of any description, laid in trenches/duct or fixing with walls/poles etc including relaying of serviceable LT UG cable at same or other location, complete all as specified and directed. 7 Excavation in trenches n. exc. 1.5m wide and n. exc. 1.5m in deep for foundation etc. or for shaft, wells, cesspits, manhole, pair house or for foundation of pole/stay etc. n. exc. 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. 8 Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. 9 Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. 10 Supply & laying double walled corrugated (DWC) HDPE duct pipe of 63mm (inner dia) conforming to IS approved colour complete with fittings for cable protection, complete all as specified and directed. 11 Supply & laying double walled corrugated (DWC) HDPE duct pipe of 32mm (inner dia) conforming to IS approved colour complete with fittings for cable protection, complete all as specified and directed. 12 M&L for50mm bore GI tubing, lightgrade, with necessary fittings such for cable protection, laid in trenches, complete all as specified and directed.Note: Boring/Earth work shall be measured and paid separately. 13 M&L for25mm bore GI tubing, light grade, with necessary fittings such for cable protection, laid in trenches, complete all as specified and directed.Note: Boring/Earth work shall be measured and paid separately. 14 Supply, laying, jointing and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core, complete all as specified and directed. 15 All as per item No. 14.00 here-in-before but cross sectional area 16 Sqmm 4 core, complete all as specified and directed. 16 Horizontal boring under the road/pavment/hardstanding (with manual method) below 1mtr from the road surface and dia of hole not exc 100mm, with out damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work and making good both the ends, complete all as specified and directed. 17 Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips

Key Value

Document Fees
INR 500 /-
EMD
INR 81000.0 /-
Tender Value
INR 40.50 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail