Tender For Addn/Altn To Tcp-2 (Ashuli Dwar) In The Area Of Age B/R-I At Rms.; 1 Dismnantling structural steel work including doors, gates but excluding frame works in truss etc complete all as specified and dir by Engr-in-Charge 2 Demolition of reinforced cement concrete of any description and inany position not otherwise specifically provided for etc complete all as specified and dir by Engr-in-Charge 3 Demolition of brick workor stone/boulder masonary built in cement mortar or cement lime mortar including all quoins, arches etc complete all as specified and dir by Engr-in-Charge 4 Demolition of plain cement concrete in ground floors and pavingsexc 15 cm thickness( below or above ground level) etc complete all as specified and dir by Engr-in-Charge. 5 Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and dir by Engr-in-Charge. 6 Dismantlingof stone slabs and tiles laid bedded or pointed in any mortar of any description or thickness in floors, aprons etccomplete all as specified and dir by Engr-in-Charge 7 Excavation over area n.exc 1.5 m deep and getting out as in soft/loose soil etc complete all as specified and dir by Engr-in-Charge. 8 Excavation over area exc 1.5m butn.exc 3.00 m deep and getting out as in soft soil etc complete all as specified and dir by Engr-in-Charge. 9 M & L for PCC (1:2:4) type B-2 in foundation filling and mass concrete etc complete all as specified and dir by Engr-in-Charge. 10 M&L forborken brick hardcore of gauge n.exc 63mm deposited, spread and leveled in layers not exc 15cm thick, watered and rammed to true surface etc complete all as specified and dir by Engr-in-Charge. 11 M & L for RCC M-25 design mix (using 20 mm graded granite stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed. 12 M & L for RCC M-25 design mix (using 20 mm graded granite stone aggregate) as in columns, pillar, piers, posts & structures etc complete all as specified and directed. 13 M & L for RCC M-25 design mix (using 20 mm graded granite stone aggregate) as in beams, cantilivers bressumers, limited over 1.5 m spam etc complete all as specified and directed. 14 M & L for RCC M-25 design mix (using 20 mm graded granite stone aggregate) as in labs suported on walls, beams & columns, roots, landing, balconies, canoies, deck slab in shelves & the like etc complete all as specified and directed. 15 M & L for cement concrete M-25 design mix using 20mm aggrigate, in chajjas etc complete all as specified and directed. 16 Use and waste for formwork to sides of concrete foundation,footings,bases of columns,raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work;vertical or to batter etc complete all as specified and directed. 17 Use & waste of formwork for Formwork to sides of pillars, posts, struts, piers, columns and stanchions all as directed by Engr-in-Charge. 18 Form work to sides and soffits of roof beams, lintels cantilevers etc complete all as specified and as directed . 19 Use & waste of formwork to chullah hoods, chajjas, troughs and similar items incl edges etc complete all as specified and dir by Engr-in-Charge. 20 M&L for form work with fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work nexc 200mm thick (horizontal or sloping) etc complete all as specified and directed. 21 M&L for Brickwork with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) etc complete all as specified and directed. 22 M&L for 15 mm thick rendering in CM (1:4)of cement finished fair faces of brick/concrete surfaces even and fair without using extra cement etc complete all as specified and directed. 23 M&L for 10 mm thick rendering in CM (1:6)of cement finished fair faces of brick/concrete surfaces even and fair without using extra cement etc complete all as specified and directed. 24 M&L for 5 mm thick rendering in CM (1:3)of cement finished fair faces of brick/concrete surfaces even and fair without using extra cement as in celing etc complete all as specified and directed. 25 M&L for APP based polymeric membrane minimum weighing 3kdg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 grms/ sqm) land on primed surface by forced application etc complete all as specified and directed. 26 S&FPlain, solid straight chowkat and frames, wrought, framedrebated on the solid, rounded or chamfred put together with glue pinned at joints , supplied and fixed in 2nd class hard wood etc complete all as specified and directed. 27 M&L for 30mm thick 2nd class hardwood, factory made plain framed pannelled shutter (any number of panels) with panels of timber flat on both sides or of veneered particle board medium density , wood particle board with commercial face veneers , supplied and fitted to chowkats cetc complete all as specified & directed by Engr-in-Charge. 28 S&F anodised aluminium powder coated any colour frame for doors, windows, grills, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 29 S&F anodised aluminium window andventilator shutters, side hung/sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified & directed. 30 S&F Sheet glass 4.8mm thick clear/sun shade colour glass, ordinary quality and glazing with oil putty in squares n exceeding 0.5sqm in each pane etc complete all as specified and directed. 31 M&L for PCC 1:2:4 type B-2 100mm thick (using 40mmgraded stone agg) as in floor, finishing surfaces of concrete topping even and fair (without using extra cement) of floor etc complete all as specified and as directed. 32 M&L for Granite (of any type) tiles 18-20mm as in platform thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigmentto match the shade of granite stone including grinding and polishing with nosing over 20 mm screed bed in CM 1:4 complete all as directed by Engr-in-Charge. 33 M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick CM (1:6) screed bed etc complete all as specified and directed. 34 M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 10mm thick CM (1:3) screed bed etc complete all as specified and directed. 35 M&L for vitrified dark shade ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and includingscreed bed or bedding layer of mortar 15 mm thick in CM (1:6)for laying floor finishes etc complete all as specified and directed. 36 M&L for preparation of new plastered surfaces and applying two coats ofcement base paint of approved shade on walls including coat of primerall as specified & directedby Engineer-in-Charge 37 M&L for applying two coats of oil bound distemper on new plastered surfaces of walls plastered incl preparation of surface complete all as specified and directed 38 M&L forpreparation of new plastered surface of ceiling and applying three coats of white wash etc complete all as specified and directed 39 M&L for applying two coats of plastic emulsion over a coat of primer on new plastered surfaces of walls incl preparation of surface complete all as specified and directed 40 M&L for TMT bars of 10mm dia and over, dia cut to length bent to shape required including cranking bending spirally, hooking ends and binding with mild steel wire not less than 0.9 mm dia(annealed) complete all as specified and directedby Engr-in-Charge. 41 All as per srl item No 40.00 here-in-before but 10mm dia as in stirrups, spacers and binders etc complete all as specified and as directed . 42 S&F Fe 410w (Gde E-250 quality only) Framed work as in doors or gates of angle or other section with gusset plates, rials braces, etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to pe prepared for hanging or sliding with and incl either hooks and hinges or steel haging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing etc complete as specified and as directed . 43 S&F 1.5mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, hole puched; incl round headed screws cout nails or rivet and fixed to wood or steel framing plain 40mm lap jhoint with riveted or welded seams, incl bending or truning up, mitre angles etc complete as specified and as directed . 44 M&L for Preparation ofnew steel surface & applying two coat of synthetic enamel paint over one coat of red oxide,zinc chrome primer on newly prepared steel surface of any description,over 10cm width or girth,not other wise describedall as specified and directed by Engr-in-Charge. 45 M&L for Preparing new wooden surface and applying two coats of synthetic enamel paint over a coat of pinkprimer complete all as specified and as directed. 46 S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed etc complete all as specified and directed 47 S & F floor door stopper of aluminium alloy body and tongue, anodised wit hard drawn steel spring, fixed in floor, overall length of cover plate 150mm etc complete all as specified and as directed . 48 Supply & FixingextrudedAluminium alloayhandles, fabricatedtype, anodised 200mm etc complete all as specified and as directed. 49 S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed. 50 Provn of PVC Sheet letter transparent 2.0 mm thick letter Size 450x600mm height, 250 to 300 mm width, 50 to 75 mm depth excluding electrical fittings but including all necessary fixing arrangement over MS sheet and anle iron framework (Note: Ms sheet and angle iron framework will be measured and paid separetely) 51 S&F stainless steel 300mm wide and height of letter n exc 400mm made up of 1mm thick sheet with handing arrangement on MS plate etc complete all as specified and directed. 52 M&L 12mm thicktoughned glass as in hinged doors, partitins automatic doors and similar work incl cutting to shape, drilling holes etc complete all as specified and directed. 53 M&L for Pavement quality concrete (PQC) of minimum 28 dyas field flexural stregnth of 45Kg/Sqcm of 4.5 Mpa, aggreate gradation as per Table 3 of IRC 15 2017, coarse aggregate of clean, hard strong, dense non-porus and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand or crushed stone sand or combination of both using minimum 360 kg/cum of cement with non-circularvirgin synthetic fibre of 12-18 mm length, specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia 15-40 micron,minimum melting temperature as 240 ̊C and minimium tensile strength of 300 Mpa and at the rate as specified by the manufacturer. PQC laid, spread and compacted with slip-form paver of minumm 7.50m width, incl curing and tining by Texturing cum curing machine complete as specified and directed. Required surface texturing to be done as specified in clause 10. 1.14 and Tabl-9 of IRC 15-2017. 54 Returning filling in soft/loose soil including spreading levelling watering and well ramming in layers not exc 25 cm complete all as specified and as directed. 55 Removing excavated material (soil) n exc 100 m and depositing where directed at a level n exc 1.50m above the starting point complete all as specified and as directed. 56 Material and labour for (concelaed Type) point wiring including necessary chases cutting of wall for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) PVC sheathed multistranded copper conductor cable 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessoriesand sunk modular GI box for mounting of fittings like switch, socket and fan regulator with modular inner plate and cover plate and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge 57 Onelight pointcontrolled by one, one way switch . 58 One Exh/Ceiling fan point controlled by one, one wayswitch. 59 One 3 pin socket outlet 5 Amps on the same board with other switches. 60 One 3 pin socket outlet 5 Amps on the Independent board. 61 All as per item No-56 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed. 62 M&L for Modular Switch 1 way 6A,1 moduleke:- Havells/Legrand/Anchor 63 M&L for modular switch 1 way 16A, 1 module 64 M&L for Modular Socket ,6A/2/3 pin combined 2 module vells/Legrand/Anchor 65 M&L Modular Socket ,6A/16A-2/3 pin combined 2 module 66 M&L for Modular Fan step regulator, 120W - 2 moduleke:- Havells/Legrand/Achor 67 M&L forceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and directed. 68 S&F for , LED Light fitting 1 x 20 watt (4 Ft), Wall/ Surface mounted, intergrated type with all accessories internally prewired and incl connecting up with, including two Nos PVC blocks and connecting upwith flexible copper cable of size 0.75 Sq mm 3 core and flexible pipe from ceiling rose to the light fitting inclcomplete all as specified and as directed. Make : Havells Cat No LHFXCEP1TNNW020(batten) & LHDLEFXD5LR020(LED Tube) or equivalent in Bajaj/Philips 69 Supply and fixing Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp bracket all as specified and directed by Engr-inCharge. 70 Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. 71 Supply and fixing for concelaed Rigid non-metallic PVC conduit of size 32mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. 72 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.Make : Usha/Bajaj/CG 73 M&L for sub main wiring with two runs of4.00 Sq mm and one run of 4.00 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVCconduit pipe complete all as specified and as directed. NOTE:- Two runs of 4.00 Sq mm + one run of 4.00 Sq mm and one run of PVC conduit pipe with accessories of suitable size shall be measured as one unit length. Make:- Richa/RR Kabel/FinolexMake of caping/casing & PVC boxes :- Prestoplast/Finolex/supreme/Richa 74 M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder coated, with200 amp rated copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. Make:- Legrand Cat No 607711 or equivalent in ABB/Siemens 75 M&L for MCB Distribution board double door type SPN 4 way, sheet steel, powder coated, with200 amp rated copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. Make:- Legrand Cat No 607711 or equivalent in ABB/Siemens 76 Supply and fixing MCB SPN 32 amp rating 240V, 10KA C curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. Make:- Legrand Cat No 607711 or equivalent in ABB/Siemens 77 Supply and fixing of MCB SP 5 to 32 Amp rating 240V, 10KA C curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. 78 Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and as directed. 79 M&L for laying brick sub class B old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed 80 Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to requirred thickness complete all as specified and as directed. (Note: Thickness of sand cushioning after punning down shall be measured for payment purpose) 81 Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 2 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etccomplete all as specified and as directed.Note : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item. 82 Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 185 Sqmm 3.5 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etccomplete all as specified and as directed.Note : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item. 83 Supply & laying tubes light grade galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 50 mm dia bore including taking down corroded GI tubing complete all as specified and as directed. 84 Material & labour for cutting/ digging of existing Hard surface of cement concreet/Bituminous road of size not less than 45 cm in width and 20 cm deep for laying of GI/CI pipe& making good to the disturbed surfaces by providing PCC or same material after laying of pipe line and returning filling of soil complete all as specified and as directed.