}

Tender For Rejuvenation Of Jjy Schemes Including Replacement Of Submersible Pump Sets / Panels / Cables And Other Allied Works Required For Functioning Of Tube Well In All Respect Including One Year Defect Liability Period Under Jen Section City-Ii, phalodi-Rajasthan

Government Departments has published Tender For Rejuvenation Of Jjy Schemes Including Replacement Of Submersible Pump Sets / Panels / Cables And Other Allied Works Required For Functioning Of Tube Well In All Respect Including One Year Defect Liability Period Under Jen Section City-Ii. Submission Date for this Tender is 06-11-2024. Screws Tenders in phalodi Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45963464
Tender For Rejuvenation Of Jjy Schemes Including Replacement Of Submersible Pump Sets / Panels / Cables And Other Allied Works Required For Functioning Of Tube Well In All Respect Including One Year Defect Liability Period Under Jen Section City-Ii
Open Tender
Indian
Rajasthan
Phalodi
06-11-2024

Tender Documents

Tender Details

Tender For Rejuvenation Of Jjy Schemes Including Replacement Of Submersible Pump Sets / Panels / Cables And Other Allied Works Required For Functioning Of Tube Well In All Respect Including One Year Defect Liability Period Under Jen Section City-Ii, 1 Revised PHED BSR 2023/2.15 - Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 2 2.15.12 -15 KW (20 HP) and above, head above 120 mtr. 3 Revised PHED BSR 2023/2.24 - Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 4 2.24.2 - 50 mm dia 5 2.24.3 - 65 mm dia 6 Revised PHED BSR 2023/2.19 - Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 7 2.19.2 - 3 core 6.0 Sq.mm 8 2.19.3 - 3 core 10.0 Sq.mm 9 Revised PHED BSR 2023/2.2 - Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 10 2.20.3 - 25.0 Sq.mm, 3.5 core 11 Revised PHED BSR 2023/2.18 - Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 12 2.18.3 - Above 15 HP and up to 20 HP

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail