Tender for supply of power to WSS to Khun, Bandal,Dugha Shigan,Jaban,Namhong,Bakhnow,Karshaigad,Ropa,Showad,Bishladhar etc. Anni Block in (E) Section Chowai Under ESD,Anni(Near Chalema source)Supply Partof 100KVA S/Stn. 2 Prov.Distribution Transformer 100 KVA,22/.04 KV (O/D Cu wound) 3 Prov. Steel pole 10 mtr long 4 Providing Muff 2 Mtr longwith concrete filling . 5 Providing x-Arms (Channel Iron(100x50x6mm) Length 2800mmx2Nos. 6 Providing MS Angle Iron (50x50x6mm) Length 2800mmX1Nos for LAs 7 Prov- X-Arms (Channel Iron (75x40x6mm) Length 2800mmX4Nos for supporting DO fuse unit &GO switch 8 Transformer Belting & Knee bracing. 9 Prov. X-Arms Channal Arms (100X50X6mm) length 2800mmX2Nos.) for transformer Bed. 10 Prov. X-Arms Channal Arms (100X50X6mm) length 460mmX2Nos.) for supporting for main channel of Transformer. 11 i)MS Angle Iron (50x50x6mm) Length:2800mmx2Nos 12 ii)MS Angle Iron (35x35x5mm) length 460mmx2Nos 13 iii)MS Angle Iron (50x50x6mm) Length:950mmx2Nos for bed knee bracing 14 Transformer LT distribution Box and GO switch fixing Assembly 15 MS Angle Iron (50x50x6mm) Length:2800mmx2Nos 16 MS Angle Iron (50x50x6mm) length 450mmx1Nos 17 GO switch handle supporting (channel (75x40x5mm) length 460mm 18 Go switch unit (22Kv,400A,25KV) Tripple pole O/Dtype 19 Providing DO Fuse Unit 20 Providing Surge Arrester 9KV Station Class (Porcelain Type) 21 Providing Disc Insuator Sets (comparising 1 No. Disc (Procelain BS 12KV ,90KN) including dead and clamp. 22 Providing Stay set complete 23 Providing Stay Wire 7/3.15 mm (@6.0 Kg. Per Stay Set ) 24 Providing Stay clamp 25 Prov. Pipe Earthing Set. 26 Prov. 6SWG GI wire for earthing 27 Providing LT Distribution Pannel Box With MCCB 160Amp. For 100KVA DTR 28 Providing Half Clamp(MS Flat 50x6mm) 29 Providing Full Clamp(MS Flat 50x6mm) 30 Providing Nut and Bolts of various sizes(galvanised/coated preferably 16mm or more with flat and spring washers) 31 Providing AluminumThimble 32 Providing Copper Thimble 200Amp. 33 Danger Plate.(Provided by HPSEBL) 34 Providing Barbed wire 35 Providing XLPE LT cable 3.5 Core 120MM² 36 Engry Meter (3-Ø,4-Wire) DLMS compliant CT operated static Trivactor meter with Box (Provided by HPSEBL) 37 Providing Aluminumpaint 38 SUPPLY OFMATERIALFOR 22 KV HT LINE 39 ACSR/6/1/3.35(50mm2) includes 3 conductor length for 3 phase and additional 1% jumpering 40 SteelTubular pole 10mtr. Mtr. 41 Providing Muff 2 Mtr longwith concrete filling . 42 X-Arms (MS Channel Iron(2800x100x50x6)mm 43 provding X-bracing Set (2800+1500) 50X50X6 44 MS Angle Knee bracing 45 Prov. Disc Insuator Sets (comparising 1 No. Disc (Procelain BS 12KV ,90KN including ,socket ball eye clevis, straight stapples & Bend Stapples etc. complete in all respect. 46 Providing 22KV Pin insulator (Porcelain,36kv,10kn), 3No. Per double pole structure (Provided by HPSEBL) 47 Providing Stay Set complete in all respect.(i/c Stay Clamp)(1No. /Single Pole,4No./Double Pole Structures) (Provided by HPSEBL) 48 Providing Stay wire (7/4.00mm)(10.0kg per stay set)(Provided by HPSEBL) 49 Single continuous Earth wire(G.I 8SWG a/w 1 wire lengths for avg. one road crossing @ 20m and additional 1% sag and wastage @ 0.102 kg/m.(Provided by HPSEBL) 50 Providing HT Earthing set complete.(Provided by HPSEBL) 51 Prov. Eye Hook for earth wire . 52 Pole Clamp. 53 Providing Danger Plate.(250x200x1.6mm) (Provided by HPSEBL) 54 Providing Nut and Bolts of various sizes(galvanised/coated preferably 16mm or more with flat and spring washers) 55 Providing Barbed wire 56 Prov. Egg Insulator 57 Providing Aluminium Paint 58 SUPPLY OFMATERIALFOR3ØLT LINE 59 Prov. ACSR /6/1/3.35(50mm2) includes 3 conductor length for 3 phase and additional 1% jumpering 60 Prov. SteelTubular pole 9 Mtr. 61 Providing Muff 2 Mtr longwith concrete filling . 62 Prov.Shackle insulator (16 kn) 63 Prov. D-iron(U-Clamps) (Provided by HPSEBL) 64 Prov. Eye Hook Bolt 65 Prov. LT Stay set(i/c Stay Clamp) 66 Prov. Stay wire 7/3.15mm (6.0kg per stay set) 67 Prov. Egg insulator 68 Prov. Earthing Set 69 Single continuous Earth wire(G.I 8SWG a/w 1 wire lengths for avg. one road crossing @ 20m and additional 1% sag and wastage @ 0.102 kg/m.(provided by HPSEBL) 70 Providing Nut and Bolts of various sizes(galvanised/coated preferably 16mm or more with flat and spring washers) 71 Providing Aluminium Paint 72 Erection of Sub-Station 73 Manual carriage of 1 no 100 Kva trasformer and allied material from road head to site of work Av. Lead 0.500Kms 74 Erection of 22/0.4 KV Distribution Sub-Station 75 Digging of pit for 2Nos. pole 76 Drilling of hole in pole & X-Arms 77 Preparation of Plate form Str. Members CI, AI i.e. X-Arm & Knee Bracing Set 78 Erection of Doublepole 79 Erection of Plateform 80 Erection of X-Arms, Drop-out 81 Erection of 2 Nos. Stay Set HT 82 Erection of Jumper 83 Earthing for 3Nos. Earths 84 Digging of Pit 85 Fixing of earth rod, clamp,earth wire and connecting to the structure 86 Providing Charcoal and Salt for the eathing 87 filling of the pit with material . 88 Providing EarthingConn. ToG.O Swich,Transformer LightningArrestoretc. & Poles 89 Providing earthing to the transformer ,LT Box,Meter Box etc. 90 Barbed Wiire & Paining 91 Erection of 100KVA S/Stn, LT Box ,MCCB Switch , cable ,service Cable and Energy Meter 92 Prov. Transformer Bed for 100KVA (Civil Work) 93 Prov. chain link fencing Angle Iron gate etc. for Transformer fencing (as per HPRS) 94 Errection of 22KV HT line 95 Manual carriage of HT line material (S/T pole 5Nos. ACSR Cond. GI wire, Cross Barcing Set, Stay Set etc.)from road head to site of work Av. Lead 0.500 Kms 96 ERECTION OF STEEL TUBULAR POLE ( single pole 10 Mtr long) 97 Erection ofsingle steel tubular poles 10 mtr.long Single str. Digging of pit , erection of pole , filling of pit ramming , drilling of holes in poles & X-Arms, fixing of insulator , X-Arm, Knee bracing set , top clamp, fixing of danger plate, painting of poles complete in all respect . 98 ERECTION OF STEEL TUBULAR POLE ( Double pole 10Mtr. long) 99 Erection ofDouble steel tubular poles 10mtr.long Single str. Digging of pit , erection of pole , filling of pit ramming , drilling of holes in poles & X-Arms, fixing of insulator , X-Arm, Knee bracing set , top clamp, fixing of danger plate, painting of poles complete in all respect . 100 Sagging of conductor 1Km. Single wire ACSR Cond. 50mm2 101 Laying of Conductor,Stringing & Sagging, Binding with insultor 102 Sagging of Single Continuous Earth wire (8 SWG) 103 Laying of Conductor,Stringing & Sagging, Binding with insultor and gaurding etc. 104 HT Earthing Set 105 Digging of pit,fixing of GI wire to the earth system and filling of pit 106 ERRECTION OF STAY SET HT 107 Digging of pit, Fixing of stay rod, Filling of pit, Nozzeling & tightening. 108 ERECTION OF 3Ø LT LINE 109 Manual carriage of 3Ø LT LINE material 110 Manual carriage of LTline material ( i.e S/T pole 4Nos. Shackle insulator D-Iron Stay Set etc.) from road head to site of work Av. Lead 0.500Kms 111 ERECTION OF STEEL TUBULAR POLE ( Single pole 9 Mtr long) 112 Digging of pit, drilling of holes in poles & x-arms, erection of pole, Erection of X-Arm,Shackle Insulator, filling of pit ramming. 113 Sagging of ACSR Conductor 6/1/3.35mm2. 114 Laying of Conductor,Stringing & Sagging, Binding with insultor 115 Sagging of Single Continuous Earth wire (8 SWG). 116 Laying of Conductor,Stringing & Sagging, Binding with insultor and gaurding etc. 117 Earthing 118 Digging of pit, Fixing of Gi wire to the Earthing System, Filling of pit. 119 ERRECTION OF STAY SET LT 120 Digging of pit, Fixing of stay rod, Filling of pit, Nozzeling & tightening.