Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-11-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-11-2024 |
| Sl. No. | Item Description |
| 1 | M&L for preparation old decorated wall surfaces, filling of holes and cracks with lime putty or plaster of paris and applying one coat of white wash on walls, complete all as specified and as directed |
| 2 | All as per item No 1 above but on ceilings |
| 3 | M&L for complete removal of existing treatment of walls including preparation ofold plastered surface, filling of holes with plaster of paris and applying two coats of oil bound distemper over a coat of wall care putty of thickness 1mm, completeall as specified and as directed. |
| 4 | M&L preparation of old surfaces of walls, filling of holes with plaster of paris and applying one coat of oil bound distemper, completeall as specified and directed. |
| 5 | M&L for applying 3mm thick wall care putty on wall surfaces, complete all as specified and directed. |
| 6 | M&L for preparation of old surfaces of steel of any description , over 10 cm in width or girth not otherwise described applying one coats of synthetic enamel paint (ordinary tint), complete all as specified and directed. |
| 7 | M&L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality), complete all as specified and directed . |
| 8 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 9 | M&Lrendering 15mm thick on fair faces of concrete surfaces in cement mortar (1:6) incl finished even and smooth without using extra cement, complete all as specified and directed. |
| 10 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster (1:4) using WPC 3% by weight of cementand finished even and smooth (without using extra cement), complete all as specified and directed.Note:- Rate of WPC shall deemed to be includedand no separate mesausrement shall be required. |
| 11 | M&L 05 mm thick rendering on ceiling / soffits of slabs in cement mortar (1:3)finished even and smoothwithout using extra cement, complete all as specified and directed. |
| 12 | M & L for preparation of new plastered surface of wall and applying two coats of distemper oil emulsion over a coat of chalk whiting as a preparatory to distempering complete all as specified and directed. |
| 13 | M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer, complete all as specified and directed. |
| 14 | M&L for preparation of new plaster surface & apply twocoats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall careputty onnew plastered surfaces and obtain smooth finish using sand paper, complete all as specified and directed. |
| 15 | Material & labour for preparation of new surfaces and applying three coats of White wash on soofits/ceiling of slab, complete all as specified and directed. |
| 16 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed. |
| 17 | Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing) and disposal of debris, complete all as specified and as directed. |
| 18 | M&L for 25mm thick Plain cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregates as in floor/sub base and finishing concrete surface fair and even to receive top floor finishes, complete all as specified anddirected. |
| 19 | M&L for screed bed or bedding layer, 15 mm thick, in cement mortar (1:6) for laying floor finishes, complete all as specified anddirected. |
| 20 | M&L for Rendering 10 mm thick, in cement mortar 1:4, on wall surfaces, as backing coat to tiles, complete all as specified anddirected. |
| 21 | M&L for Non skid ceramic coloured plain tiles of size 300 x 300 x 7mm/ 400 x 400 x 7mm thick, first quality,laid in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. |
| 22 | M&L for Glazed ceramic tiles, 300/350 x 450 x 7mm thick, glossy finish, first quality, of approved colour, laid on vertical surfaces such as skirting or dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed. |
| 23 | M&L for Granite 20 mm thick (of any type ) (table runned and polished ) in floors steps , jamns, pillars,window-cills,cooking plateforms and vertical surfaces bedded and jointed with grey cement slurry and pointing in white ciment (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed. |
| 24 | Cleaning &removal all scales & dirt etc, from tanks of capacity exc 500 but n.exc 1000 Ltrs & from mouths of circulating pipe etc, complete all as specified and directed. |
| 25 | Cleaning &removal all scales & dirt etc, from tanks of capacity exc 250 but n.exc 500 Ltrs & from mouths of circulating pipe etc, complete all as specified and directed. |
| 26 | S&F in repair Vitreous china squatting pan of orissa pattern, size 580 x 440 mm, white, with \"P\" or \"S\" trap, with integral foot rest, including demolition and removal of existing old pan, complete all as specified and directed |
| 27 | S&F in repair Vitreous china wash down water closet, pedestal pattern (EWC), white, with \"P\" or \"S\" trap, with PVC water closet seat, black or white, closed pattern, with flat bottom and cover and mild steel chromium plated or aluminised hinging device including taking down and removal of existing old water closet with seat cover, complete all as specified and directed |
| 28 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth,complete all as specified and directed. |
| 29 | Supply, Laying and testing in repair of 16mm bore of pipe in 3 layer PP-R polypropylene random copolymer pipes, SDR 7.4 (PN-16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R Plain & brass threaded polypropylene random fittingfixed complete to walls, ceilings or in floors etc, complete all as specified and directed. |
| 30 | Supply, Laying and testing in repair of 20mm bore of pipe in 3 layer PP-R polypropylene random copolymer pipes, SDR 7.4 (PN-16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R Plain & brass threaded polypropylene random fittingfixed complete to walls, ceilings or in floors etc, complete all as specified and directed. |
| 31 | S&F in repair Stainless steel Harrison curtain rails, 19/20mm dia, including stainless steel brackets and fixing brackets, stops, rollers etc including taking down old one, complete all as specified and as directed. |
| 32 | S&F 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and taking down old one, complete all as specified and as directed |
| 33 | S&F 50mm low density polyethene pipe (LDPE) of pressure rating 6 Kgf/Sq.cm fixedcomplete in wall ,floor etc including taking down old one, complete all as specified and as directed. |
| 34 | Dismantling water tanks of capacity exc 250 & n exc 500 litres and removing to store complete all as specified and directed. |
| 35 | S&F 500 litres capacity, tripple layer, rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position, complete all as specified and directed. |
| 36 | S&F in repair Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed in wooden/steel/ Aluminium windows, or Stainless steel wire staples, complete all as specified and as directed. |
| 37 | S&F sheet glass 3mm thick ordinary quality and glazing with oil putty or beads fixed with screws in sequence not exceeding 0.5 sqm in each pane including dismantling/taking down old panes, complete all as specified and as directed. |
| 38 | Dismantling boarding, any description, fixed in any position with nails, complete all as specified and directed. |
| 39 | M&L for 18/19 mm thick Block board, Grade 2 quality, interior grade, decorative type with decorative face veneer on one face, fixed for cupboard shutter, shelve, partiion & kitchen cabinet, complete all as specified and as directed. |
| 40 | S&F in repair Stainless steel plate rack of minimum size 750mm x 750mm x 250mm made with 4-5 mm dia stainless steel rods, including all necessary fixing arrangements, complete of all as specified and directed. |
| 41 | M&L for welding repair works at small patches like hinges, door closer, window repair, steel door/gate fittings like hinge, bolts, bars etc, complete all as directed. |
| 42 | M&L in repair for PVC (SWR) floor trap 75 mm dia of outlet , plain with grating including jointing with solvent cement complete all as specified and directed. |
| 43 | S&F in repair ofPVC (SWR) pipe, 75 mm bore, sinlge socketed in any length with rubber ring joints fixed in walls, complete all as specified and directed. |
| 44 | S&F in repair ofPVC (SWR) pipe, 110 mm bore, sinlge socketed in any length with rubber ring joints fixed in walls, complete all as specified and directed. |
| 45 | M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete all as specified and directed. |
| 46 | S&Fvitreous china wash basin, white back, size 550 X 400 mm including new waste coupling and waste pipe etc , errectingon existing CI brackets including taking down old one, complete alll as specified and as directed . Note:- If the mentioned size is not available in the market , the next immediate higher size shall be provided by the contractor . |
| 47 | S&F in repair sink made of stainless steel 1mmthickkitchenorlaboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including new waste coupling and waste pipe etc, complete all specified and as directed. |
| 48 | S&F in repairs 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 49 | S&F in repair bib taps, fancy type CP, screwed for 15mm bore of iron pipe or for brass ferrule and fixed all as specified and directed. |
| 50 | S&F in repair stop valves, fancy type, CP with long shank and cup (concealed type), screwed both ends for 15mm bore of iron pipe or for union and fixed all as specified and directed |
| 51 | S&F in repair pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered \"HOT\" or \"COLD\" with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe and fixed all as specified and directed |
| 52 | S&F in repair of Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified. |
| 53 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc,complete all as specified and directed . |
| 54 | M&L for Brickwork with subclass \"B\" bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as directed. |
| 55 | All as per item No 54 above but except bricks. |
| 56 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and as directed. |
| 57 | M&L for 50 mm thick PCC 1:3:6 type C-2, using 40 mm stone aggregate, as in plinth protection / path/ any paved area, complete all as specified and directed. |
| 58 | M&L 75mm thick PCC type D-2, 1:4:8, using 40mm graded stone aggregate as in sub base all as specified and directed. |
| 59 | M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment over specified thickness of sand cushioning, complete all as specified and directed.Note:- Sand shall be measured and paid separately. |
| 60 | All as per item No 59 above except tiles. |
| 61 | M&L for 80 mm thick machine cut precast concrete inter locking paver block except tile ,(M-40) grade complete all as specified and directed |
| 62 | M&L for sand filling under floors or in foundationincluding watering and consolidation, complete all as specified and directed. |
| 63 | M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed. |
| 64 | M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying offloor/sub base finishes, complete all as spd and directed. |
| 65 | S & F in repairfor precast factory madereinforced cement concreteManhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of thickness 1mm(size and thickness of cover will be intimated by the Engineer-in-Charge) complete all as specifiedand as directed. |
| 66 | S&F mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to RCC post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc and including 10mm MS bars as in tie bars fixed to fencing posts including necessary welding where required, as per site requirement and other similar works complete, conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 67 | S&F in repair precast factory made polycrete (SFRC) medium duty perforated drain cover, 100 mm thick, rectangle in shape, upto 01 sqm area each with hole for drain, complete all as specified and directed. |
| 68 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm, complete all as specified and directed. |
| 69 | M&L for Plain cement concrete (1:2:4) Type B-1, (using 20mm graded crushed stone aggregate), as incopings, kneelers , apex stones,bed plates, including weathering ,slightly rounded /benching or chamfered angles and throating, complete all as specified and directed.Note:- Rates include for use of formwork |
| 70 | M&L for Plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in surface channels, drains and bed of manhole, completeallas specified and directed.. |
| 71 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 72 | M&L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling, and mass concrete, complete all as specified and directed. |
| 73 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works, complete all as specified and directed. |
| 74 | M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs ( for manholes etc.), shelves and similar articles with plain faces including necessary form work, set in cement mortar 1:6 completeall as specified and directed. Note:- Reinforcement shall be measured and paid for separately under respective item of BOQ. |
| 75 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 76 | Removing debries/excavated material to a distance exceeding 1.5KM butnot exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as directed. |
| 77 | Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) completeincluding all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed. |
| 78 | Taking down carefully copper / aluminum two core sub main wiring of sizes 4/6 Sqmm cable any type and removing old material from site and making good disurbed surface all as specified |
| 79 | M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathedmulti stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathedmulti stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and in existing concealed / surface PVC Conduit/ saddle medium grade, ISI marked 20 mm diaalong with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators as per specified SSR and as directed by Engineer- in- Charge.NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls. |
| 80 | All as per item No 79above but 5 Amp socket outlet, independent. |
| 81 | All as per item No 79 above but on the same board. |
| 82 | All as per item No 79 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly. |
| 83 | M&L for point wiring with single core FRLS PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through inPVC conduit, fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and provision of modular metal flush boxof suitable sizemodular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed.(a) One light point controlled by one switch. |
| 84 | All as per item No 83 above but 5 Amp socket outlet, independent. |
| 85 | All as per item No 83 above but on the same board. |
| 86 | All as per item No 83 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly. |
| 87 | Supply & fixing in replacement of switch piano type 5 amp SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge. |
| 88 | Supply & fixing in replacement of switch 15 Amps SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge. |
| 89 | Supply & fixing in replacement of socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge. |
| 90 | Supply & fixing in replacement of socket outlet 2-in-1, 3 pin 5 amps and 15 amps flush type complete all as specified and directed by Engineer-in-Charge. |
| 91 | M&L for socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. |
| 92 | M&L for socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed. |
| 93 | S&Fstepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc. |
| 94 | M&L for switch 6 amps modular type one one way complete all as directed. |
| 95 | M&L for switch 16 amps modular type one one way complete all as directed. |
| 96 | Supply and fix modular white cover plate with frame 1 module ISI markedcomplete all as specified and as directed. |
| 97 | Supply and fix modular white cover plate with frame 2 module ISI markedcomplete all as specified and as directed. |
| 98 | Supply and fix modular white cover plate with frame 3 module ISI markedcomplete all as specified and as directed. |
| 99 | Supply and fix modular white cover plate with frame 4 module ISI markedcomplete all as specified and as directed. |
| 100 | Supply and fix modular white cover plate with frame 6 module ISI markedcomplete all as specified and as directed. |
| 101 | Supply and fix modular white cover plate with frame 8 module ISI markedcomplete all as specified and as directed. |
| 102 | Supply and fix modular metal flush box 3 moduleISI markedcomplete all as specified and as directed. |
| 103 | Supply and fix modularAmp combined box with 6/16 switch and socketISI markedcomplete all as specified and as directed. |
| 104 | Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 4\"x4\" complete all as specified and as directed. |
| 105 | Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 7\"x4\" complete all as specified and as directed. |
| 106 | Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 8\"x10\" complete all as specified and as directed. |
| 107 | Supply & fixing in replacement of MCCB 100 Amps 4 pole 16 KA 415 volts complete all as specified and directed by Engineer-in-Charge. |
| 108 | S&F in replacement MCCB,Four pole,415 volts, 125 Amps , curve \"C\",breaking capacity 10 KA,all as specified and directed by Engineer-in-charge |
| 109 | S&F in repairs,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp.. |
| 110 | S/Fix in replacement MCB DB SPN 6 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc completed after dismantling old one. |
| 111 | S&F in repairs,sheet metal enclosure for MCB DB\"s SPN 240 volts, 4 way with neutral bus bar 200 Amp rated double door type regal grey all as specified and directed by Engr-in-charge. |
| 112 | All as mentioned in item No 111 here in above but 08 ways DBs |
| 113 | All as mentioned in item No 111 here in above but 12 ways DBs |
| 114 | All as mentioned in item No 111 here in above but TPN DB, 4 ways DBs |
| 115 | S&F in repairs MCB SP 6 to 32 Amps 240 Volts.\"B\" grade complete all as specified and directed. |
| 116 | S&F in repairs MCB,SP 40 Amps, 240 Volts.\"B\" grade complete all as specified and directed. |
| 117 | S&F in repairs MCB,SPN 6-32 Amps, 240Volts,\"B\" grade complete all as specified and directed. |
| 118 | S&F in repairs MCB SPN, 40 Amps, 240Volts .\"B\" grade complete all as specified and directed. |
| 119 | S&F in repairs MCB SPN, 63 Amps, 240Volts.\"B\" grade complete all as specified and directed. |
| 120 | S&F in repairsMCB TPN 16 to 32 Amps,415Volts .\"B\" grade complete all as specified and directed. |
| 121 | S&F in repairs MCB TPN, 40 to 100 Amps,415Volts .\"B\" grade complete all as specified and directed. |
| 122 | Supply and fixing amp rating 240V, SP 5 To 32 AMP 10KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 123 | Supply and fixing amp rating 240V, SPN 40 To 63 AMP 10KA \"C\" curve miniature circuit breaker (MCB)and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 124 | S&F in replacement MCB TP 40 to 63 Amps,415 volts curve \"C\",breaking capacity 10KA, all as specified and directed. |
| 125 | Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting outcomplete all as specified and directed. |
| 126 | Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cmapart complete all as specified and directed. |
| 127 | Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 128 | Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable all as specified and as directed. |
| 129 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mmcomplete all as specified and directed. |
| 130 | Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 35 Sqmm 3.5 core complete all as specified and directed. |
| 131 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½XLPE, armoured, Al conductor cable of size 120 to 240 sqmm,Outdoor type complete all as specified and directed. |
| 132 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½XLPE, armoured, Al conductor cable of size 95 to 120 sqmm,Outdoor type complete all as specified and directed. |
| 133 | Supply and fix cable duct cover made of iron of size 320mm x 800 mm of thickness 3.0 mm complete all as specified and directed. |
| 134 | M&Lfor Providing,PCC 1:3:6 type C-1 using 20 mm graded stone aggreat,for damaged earth pit chamber with fair finish internal surface of concrete chamber of earthcomplete all as specified and directed. |
| 135 | M& L for preparationof trench for cable laying of size 300mm x 450 x 10 m long including excavation, brickwork, PCC work , plastering and finishing all as speciified and as directed. |
| 136 | M& L for precast earthing RCC pit with cover of standard size duly painted in Red or Green complete all as specified and directed. |
| 137 | M&L for earth pit cover bucket type Red or Green complete all as specified and directed. |
| 138 | M&L for CI plate triangular with 500 mm long spike for writing earthing name and value complete all as specified and directed. |
| 139 | M & L in repairs earthing complete with galvanised steel earth plate electode 600 x 600 x 6.0 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & including galvanised steel wire 4.0 mm diasize means of nuts and bolt check nuts and washers of galvanised rion sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to earthing test point complete including testing filling of adquate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil upto 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed. |
| 140 | M & L in replacement earthing with steel earth plate electrode of size 60 x 60 cm x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and directed. |
| 141 | M&L in repair Pre-cast cement concrete block masonry with solid blocks PCC Type B1 1:2:4 ( 20 mm graded aggregate ) , exc. 10 cm in width and setting in mortar complete all as specified and directed. |
| 142 | M&l in replacement tubing light grade galvanized iron to be embeded in PCC block fitting complete with 40 mm bore complete all as specified and directed. |
| 143 | M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 6 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly complete all as specified and directed. (Flexible Copper Wire Used In FRLS) |
| 144 | Allas per item No 143 mentionedhere-in- before but 4.0 sq mmPVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single corefor continuous earthing complete. |
| 145 | M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 1.5 Sqmm duly drawn through and including concealed PVC conduit suitable size as sub main with continuous earth wire 1.5 Sqmm size and connecting to common earth dolly complete all as specified and directed. (Flexible Copper Wire Used In FRLS) |
| 146 | Dismantiling and taking out burnt winding by cutting, clening slots and re-Winding of AC celling fan motor 1200/1400 mm any make of fan with super enameled copper winding wire of existing gauge varnishing with E class insulation varnish. threading, including neceassry laith work and connnecting with appropriate size copper conductor cable upto connector block complete all as specified and directed.Notes:- (i) Doctor brand or equivalents ISIbrand varnish shall only be used.(ii) Motor shall be wound with machine only.(iii)BIC/HTP or DEVIDYAL. make super enameled copper winding wire shall only be used.(iii)The weight of copper winding wire shall be 200 to 350 gram per fan. |
| 147 | All as per item No 146 above butweight of copper winding wire shall be above and upto 500 gms per fan. |
| 148 | All as per item No 146 above butweight of copper winding wire shall be above 500 gms and upto 750 gms per fan |
| 149 | Supply and Fix cable PVC insulated and overall sheathed with flexible copper conductor cable of size 0.5 sqmm,3 core cut to size of approx 0.30 metre fromblock of fan to ceiling rose complete all as specified and directed. |
| 150 | Supply and fixing in replacementof PVC insulated flexible copper conductor cable 40/0.0076 size 3 core suitablefor 650 volts grade complete all as specified and directed. |
| 151 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories 230V, 1200/1400mm sweep with squirrel cage induction motor complete all as specified and directed. |
| 152 | Material and Labour for Replacement of old unserviceable gun metal bush of ceiling fan including neceassry laith, Grindingand welding work complete all as specified and directed. |
| 153 | Material and Labour for Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd (ISI marked) complete all as specified and directed. |
| 154 | Material and Labour for Replacement of old unserviceable capacitor AC 400/415 volts 3.15 mfd(ISI marked) complete all as specified and directed. |
| 155 | Material and Labour for Replacement of old unserviceable capacitor AC 400/415 volts 4.00 mfd (ISI marked) complete all as specified and directed. |
| 156 | Material and Labour for Replacement of old unserviceable ball bearing of size 6200 to 6204 including neceassry laith , Grinding and welding work complete all as specified and directed. |
| 157 | Taking down ceiling fan complete any type size from existing location andcleaning body blades etc including servicing, greasing,oiling, replacing wornout bearing ,bush and refixing the same at site complete all as specified and directed. |
| 158 | All as mentioned in item No 157 here in above but for Exhaust fan 300 mm sweep. |
| 159 | All as mentioned in item No 157 here in above but for Exhaust fan 450 mm sweep complete |
| 160 | All as mentioned in item No 157 here in above but for wall/floor mounted fan 450 mm sweep complete |
| 161 | Rewinding unserviceable ceiling fan 1200/1400 mm Sweep from siteby strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and as directed by Engr-in-Charge. |
| 162 | All as mentioned in item No 161 here in above butfor Exhaust fan 300 mm sweep complete |
| 163 | All as mentioned in item No 161 here in above butfor Exhaust fan 450 mm sweep . |
| 164 | All as mentioned in item No 161 here in above butfor wall/floor mounted fan 450 mm sweep. |
| 165 | S&Fwall mountingfan motor for 450 mm sweepcomplete all as specified and directed. |
| 166 | Supply and fix Ventilation fan PVC (250 mm Sweep) with louvers and acessories complete all as specified and directed. |
| 167 | Supply and fix Ventilation fan PVC (200 mm Sweep) with louvers and acessories complete all as specified and directed. |
| 168 | Material and Labour for Replacement of old unserviceable shackle assembly kit (Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos) suitable for ceiling fan of 1200/1400mm sweep complete all as specified and directed. |
| 169 | S&Fin repairs,ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed. |
| 170 | Material and Labour for Replacement of old unserviceable fan blades, (ISI Marked), suitable for 1200mm sweep ceiling fanduly painted in white/brown by using spray gun method(fully furnished) complete all as specified and directed. |
| 171 | Material and Labour for Replacement of old unserviceable fan blades, (ISI Marked), suitable for 1400mm sweep ceiling fandully painted in white/brown by using spray gun method(fully furnished) complete all as specified and directed. |
| 172 | Material and Labour for Repalcement of old unserviceable down rod of ceiling fan of dia 20mm bore \"medium grade\" complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) dully painted in white/brown by using spray gun method (fully furnished) complete all as specified and directed. |
| 173 | Material and Labour for Replacement of old unserviceable steel screw of size 5mm to 8mm (to be used for fixing of fan blade) complete all as specified and directed. |
| 174 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 175 | Supply and fix exhaust fan sweep 250 mm in replacement made up of sturdy engineering metal body complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed. |
| 176 | S & F Recess mounted LED Light Fitting 15 Wattpressure die-cast aluminium luminaire in powder coated white finish in round/square profile with optimized heat sink for efficient heat dissipation and incl separate replaceable electronic driver compatible forAnalog/DALI Dimming complete all as specified and directed. |
| 177 | S&F in repairs,LED tube light batten 22W LED,6000K (4 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed. |
| 178 | S&F in repairs,LED tube light batten,9/10W(+) 2% LED 6000K (2 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed. |
| 179 | S&F in repairs,LED false ceiling panel fittings ,1x45W/1x40W LED 6000K (2ftx2ft.), 230 volts AC,suitable for false ceiling, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed. |
| 180 | Supply and fixing LED Lamp 36/40 Watts high Efficiency PMMA diffuser soft glare free light complete and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting complete all as specified and directed. |
| 181 | Supply and fixing Decorative type LED-Post top 40Watts,230 V, IP 65, 5700K rated with control driver with efficiency 90% pure coated aluminium die cast and spun aluminium body with clear/opal diffuser suitbale for landscape lighting for uniform illumination prewired including all accessories and connecting up with twin core copper conductor with suitable size complete all as specified and directed. |
| 182 | Supply and fix modular type gang box(3 module for one socket and one switche) suitable for 5/15amp 6pin including plate cover plastic sunken box etc including suitable size of switches and sockets as per as directed by Engg-in-Charge. |
| 183 | Supply and fix in replacement of PVC casing capping of size upto 25mm to enclose and protect any unconcealed internal wiring of any sizing all as directed by Engg-in-charge. |
| 184 | Taking down storage water heater 25 ltrs capacity from wall for repair/replacement of unserviceable parts and refixing with fasterners Nuts and washers the same after repair work complete all as specified and as directed. |
| 185 | M&L for replacement of thermostate 0-60 degree as per sample in water geyser 25/50 litre capacityISI Make as per sample complete all as directed.. |
| 186 | M&L for replacement of heating element 1.5KW,Triangular/round type as per sample complete all as directed. |
| 187 | M&L for replacement of heating element 2 KW with complete assembly of any model and type as per site requirement /sample complete all as directed. |
| 188 | Materialand Labour for disconnecting from electric and water mains and dismantling the unserviceable gyeser base assembly and replacing the new base assembly 6/9 holes with rubber gasket for 25 Ltrs capacity of any make and refixing in original place including recoonecting of electric and water supply mains including testingcomplete all as specified and directed. |
| 189 | M&L for replacement of geyser outer body cover of 25 Ltr capacity made out of 16 SWG powder coated completewith all connected accessories suitably fitted with existing wall complete all as specified and directed. |
| 190 | M&L for replacement of geyser tank stainless steel suitable for 25 Ltr capacity geyser complete all as specified and directed. |
| 191 | M&L for replacement of PVC connection with brass inserts suitable for hot/cold water, 60 cm long (for hot and cold water inlet and outlet) having PTMT nuts with washer complete all as specified and directed. |
| 192 | S & F in Replacementof bottom cover suitable cylindrical type geyser as per existing required as per site for 25 Ltrs capacity complete all as specified and directed. |
| 193 | Dismantling and opening storage tank of geyser 25 litre capacity to identify the leakage ,repair the spot by suitable welding carefully including making good insulating material, assembling and testing complete all as specified and directed. |
| 194 | S & F in replacementof indicationlamp red and green (pilit type ISI marked) for 25Ltrs water heater complete all as specified and directed. |
| 195 | S & F in replacement of glass wool in any capacity of geyser complete all as specified and directed. |
| 196 | Supply only FR PVC electrical insulation tape,1.8 cm x 25 mtr x0.125 mm thick complete all as specified and directed. |
| 197 | Supply only aluminium thimbles of size 35 sqmm complete all as specified and directed. |
| 198 | Supply only aluminium thimbles of size 50 sqmm complete all as specified and directed. |
| 199 | Supply only aluminium thimbles of size 70 sqmm complete all as specified and directed. |
| 200 | Supply and laying PVC insulated sheathed aluminum conductor cable 16 sqmm two single core 1100 volts grade multistanded conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connections complete all as specified and directed. |
| 201 | Taking up or down 25 mm dia.steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 202 | All as per item No 201 above but 20 mm dia. |
| 203 | All as per item No 201 above but 15 mm dia. |
| 204 | Supply, laying and fixing 25mm dia. GI water tubing medium grade with all fittings and fixed complete to all walls,ceiling,laid in floors,roof etc withfollowing sizes complete all as specified and directed. |
| 205 | All as per item No 204 above but 20mm dia. |
| 206 | All as per item No 204 above but 15mm dia. |
| 207 | Replacement ofold unserviceableand providing new safety valve(ISI Marked) suitable for 25 to 50 Ltrs capacity geysers complete all as specified and directed. |
| 208 | M & L for Replacement of old unserviceableand providing new non return valve made out of brass (ISI marked) for bore dia of pipe 15mm size complete all as specified and directed. |
| 209 | M & L for preparing the old painted steel surface by rubbing/scratching the old paint of 25 ltrs capacity geyser and painting with two coats of synthetic enameled paint white with spray gun including writing MES Nos with black paint (of required size and shape) complete all as specified and directed. |
| 210 | M & L formetal clad plug top 20 A 2 P+ E, 230 V AC asin repair complete all as specified and directed. |
| 211 | M & L formetal clad socket 20 A 2 P+ E 230 V AC asin repair complete all as specified and as directed |
| 212 | Supply & fix anchor bolt of size 12mm x 100mm long with washer including drilling holes for fixing anchor bolt and making good to the disturbed surface matching withspecification complete all as specified and directed. |
| 213 | M & Lfor Descaling of gyser of capacity 25litre /50litre from wall after unscrewing nuts/boltsetc and again refixing in position after repair including strip opening the assembly,de-scalling the syphon assembly, steel tank and incoming and outgoing water connection complete all as specified and directed. |
| 214 | M&L in replacementAir termination franklin typr ,copper rod 12mm dia and 300mm long complete all as specified and directed. |
| 215 | M&L in replacement GI32 x 6mm with saddles and fixing screws etc. for roof conductors and down conductors including saddles,insulator, nut & bolts brazing etcabove ground complete all as specified and directed. |
| 216 | M&L in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed. |
| 217 | Removing all connections from LT panel having feeders upto 04 Nos ( Total of incoming and outgoing) , any capacity,indoor or outdoor type,fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice complete all as specified and directed. ( U/S items will be provided against respective items separately). |
| 218 | Removing all connections from LT panel having feeders above 04 Nos upto 08 Nos ( Total of incoming and outgoing) , any capacity,indoor or outdoor type,fpr repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice complete all as specified and directed.. ( U/S items will be provided against respective items separately). |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy