}

Tender For Supply Of Consumables/Non-Consumables For The Department Of Paediatrics, Pondicherry-Puducherry

Boards / Undertakings / PSU has published Tender For Supply Of Consumables/Non-Consumables For The Department Of Paediatrics. Submission Date for this Tender is 19-11-2024. Kitchen Equipment Tenders in Pondicherry Puducherry. Bidders can get complete Tender details and download the document.




Tender Notice

45904579
Tender For Supply Of Consumables/Non-Consumables For The Department Of Paediatrics
Open Tender
Indian
Puducherry
Pondicherry
19-11-2024

Tender Documents

Tender Details

Supply Of Consumables/Non-Consumables For The Department Of Paediatrics , Respiratory Consumables , Yankauers Oral Suction Tube - Pediatric Size. Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of Atleast 50 Cm With A Single Hole At The Tip 3). Should Be Soft And Kink Resistant , Disposable Sterile De Lee Mucous Extractor. Specifications: 1). Should Have A Separate Screw Top Lid 2). Should Be Soft Frosted And Kink Resistant Tubing 3). Chamber Should Be Atlest 25 Ml Capacity 4). Should Be 6 Fr Size Catheter , Reusable Flexible Laryngeal Mask Airway- Size 1. Specifications: 1). Should Be Soft And Kink Resistant 2). Optinmal Cuff Pressure And Volume Should Be Mentioned On The Lma/Cuff , Reusable Flexible Laryngeal Mask Airway- Size 1.5. Specifications: 1). Should Be Soft And Kink Resistant 2). Optinmal Cuff Pressure And Volume Should Be Mentioned On The Lma/Cuff , Reusable Flexible Laryngeal Mask Airway- Size2. Specifications: 1). Should Be Soft And Kink Resistant 2). Optinmal Cuff Pressure And Volume Should Be Mentioned On The Lma/Cuff , Reusable Flexible Laryngeal Mask Airway- Size 2.5. Specifications: 1). Should Be Soft And Kink Resistant 2). Optinmal Cuff Pressure And Volume Should Be Mentioned On The Lma/Cuff , Reusable Flexible Laryngeal Mask Airway- Size -3. Specifications: 1). Should Be Soft And Kink Resistant 2). Optinmal Cuff Pressure And Volume Should Be Mentioned On The Lma/Cuff , Guedel Oropharyngeal Airway (Size-00) Neonatal. Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Colored Coded For Easy Identification Of Size , Guedel Oropharyngeal Airway (Size-0) Infant. Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Colored Coded For Easy Identification Of Size , Guedel Oropharyngeal Airway (Size - 1) Child. Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Colored Coded For Easy Identification Of Size , Guedel Oropharyngeal Airway (Size - 2) Small Adult. Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Colored Coded For Easy Identification Of Size , Guedel Oropharyngeal Airway (Size - 3) Medium Adult Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Colored Coded For Easy Identification Of Size , Soft Nasopharengeal Airways (Inner Diameter 3 Mm). Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter , Soft Nasopharengeal Airways (Inner Diameter 3.5 Mm). Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter , Soft Nasopharengeal Airways (Inner Diameter 4 Mm). Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter , Soft Nasopharengeal Airways (Inner Diameter 4.5 Mm). Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter , Soft Nasopharengeal Airways (Inner Diameter 5 Mm). Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter , Soft Nasopharengeal Airways (Inner Diameter 5.5 Mm). Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter , Soft Nasopharengeal Airways (Inner Diameter 6 Mm). Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter , Soft Nasopharengeal Airways (Inner Diameter 6.5 Mm). Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter , Nasal Prongs For Oxygen Deliver - Neonatal Size Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Machanism To Adjust The Length For A Proper Fit , Nasal Prongs Oxygen Deliver - Pediatric Size Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Machanism To Adjust The Length For A Proper Fit , Ram Cannula (Prongs Outer Diameter 3 Mm ) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Machanism To Adjust The Length For A Proper Fit 4). Should Be Competible With Standard Ventilator Circuit Adapter , Ram Cannula (Prongs Diameter 3.5 Mm ) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Machanism To Adjust The Length For A Proper Fit 4). Should Be Competible With Standard Ventilator Circuit Adapter , Ram Cannula (Prongs Diameter 4 Mm ) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Machanism To Adjust The Length For A Proper Fit 4). Should Be Competible With Standard Ventilator Circuit Adapter , Ram Cannula (Prongs Outer Diameter 5.25 Mm ) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Machanism To Adjust The Length For A Proper Fit 4). Should Be Competible With Standard Ventilator Circuit Adapter , Ram Cannula (Prongs Outer Diameter 5.75 Mm ) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Machanism To Adjust The Length For A Proper Fit 4). Should Be Competible With Standard Ventilator Circuit Adapter , Ram Cannula (Prongs Outer Diameter 6.5 Mm ) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Machanism To Adjust The Length For A Proper Fit 4). Should Be Competible With Standard Ventilator Circuit Adapter , Non Rebreathing Oxygen Mask (Nrm) With Reservoir - Paediatric Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Adjustable Elastic Head Bands , Nebulisation Set With Tubing Disposable (Pediatric Size) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Adjustable Elastic Head Bands 4). Should Be Compatible With All Standard Nebulizer Compressors , Tracheal Mask For Nebulisation, Pediatric Size Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Adjustable Elastic Bands 4). Should Be Compatible With All Standard Nebulizer Compressors , T Piece Connector For Ventilator / Nebuliser - 22 Mm Od, 15 Mm Id, 22 Mm Od Specifications: 1). Should Be Kink Resistant 2). Size Should Be Labelled , T Piece Connector For Ventilator / Nebuliser - 15 Mm Od, 22 Mm Id, 22 Mm Od Specifications: 1). Should Be Kink Resistant 2). Size Should Be Labelled , T Piece Connector For Ventilator / Nebuliser - 15 Mm Od, 15 Mm Id, 15 Mm Od Specifications: 1). Should Be Kink Resistant 2). Size Should Be Labelled , Flexible Double Swivel Catheter Mount For Ventilator Circuit (Demo Needed) Specifications: 1). Should Be Kink Resistant 2). Should Be Made Of Reusable Material , Oxygen Delivery Face Mask With Adapter For Oxygen Tube - Pediatric Size Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Adjustable Elastic Head Bands , Oxygen Delivery Face Mask With Adapter For Oxygen Tube - Adult Size Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Adjustable Elastic Head Bands , Flow Inflating Bag (Paediatric) For Resuscitation. Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Peep Regulating Mechanism 4). Should Have A Volume Of 1000 To 1500 Ml 5). Should Have The Neccesory Tubing And Oxygen Supply Connector , Flow Inflating Bag (Infant) For Resuscitation. Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Peep Regulating Mechanism 4). Should Have A Volume Of 400 To 500 Ml 5). Should Have The Neccesory Tubing And Oxygen Supply Connector , Reusable Stylet For Endotracheal Intubation Compatible With Endotracheal Tube Sizes 3, 3.5, 4 , 4.5, 5, 5.5, 6- (6 French) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Flexible Enough To Be Moulded Gnetly, And Stiff Enough Hold Its Shape 3). Should Be Atleast 30 Cm , Reusable Stylet For Endotracheal Intubation Compatible With Endotracheal Tube Sizes 3, 3.5, 4 , 4.5, 5, 5.5, 6 - (10 French) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Flexible Enough To Be Moulded Gnetly, And Stiff Enough Hold Its Shape 3). Should Be Atleast 30 Cm , Reusable Stylet For Endotracheal Intubation Compatible With Endotracheal Tube Sizes 3, 3.5, 4 , 4.5, 5, 5.5, 6 (14 French) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Flexible Enough To Be Moulded Gnetly, And Stiff Enough Hold Its Shape 3). Should Be Atleast 30 Cm , Gum Elastic Bougie (To Aid Difficult Intubation) - Pediatric Size ( 15 French) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Flexible Enough To Be Moulded Gnetly, And Stiff Enough Hold Its Shape 3). Should Be Atleast 40 Cm , Gum Elastic Bougie (To Aid Difficult Intubation) - Pediatric Size (10 French) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Flexible Enough To Be Moulded Gnetly, And Stiff Enough Hold Its Shape 3). Should Be Atleast 40 Cm , Gum Elastic Bougie (To Aid Difficult Intubation) - Neonatal Size (5 French) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Flexible Enough To Be Moulded Gnetly, And Stiff Enough Hold Its Shape 3). Should Be Atleast 40 Cm , Endotracheal Tube Cuff Pressure Monitor Specifications: 1). Should Have Optimal Connector For The Endotracheal Tube Cuff 2). Pressure Guage Should Be In Cm Of Water Unit 3). Optimal Pressure Should Be Indicated On The Pressure Guage 4). Should Have Machnism To Inflate Or Deflate The Cuff , Emergency Cricothyroidotomy Kit. Seldinger Technique Based (Pediatric) Specifications: 1). The Set Should Include Atleast Cricothyrotomy Catheter, Introducer Needle, Catheter Introducer Needle, 5-10 Ml Syringe, Mini Scalpel, Wire Guide, Curved Dilator And Trach Tape 2). Should Havetepwise Instructions For Use With Labelled Components 3). Should Be Soft And Kink Proof 4). Should A Smooth, Rounded, Atraumatic Edges , Expiratory Filter For Paediatric Ventilator Circuit. Specifications: 1). Should Be Compatible With Maquet Servo-I Ventilator 2). Should Be Resistant To Bacterial Growth 3). Should Not Offer Resistnace To Air Flow , Humidification Chamber (Infant/ Neonate) Specifications: 1). Should Be Compatible With Fischer And Paykel Mr 850 Humidifier 2). Should Have Auto Fill And Auto Cut Off For The Water Level 3). Should Have A Minimum And Maximum Water Level Markings 4). Should Have The Standard Connecting Ports For Inspiratory Limb Of Ventilator , Humidification Chamber (Pediatric). Specifications: 1). Should Be Compatible With Fischer And Paykel Mr 850 Humidifier 2). Should Have Auto Fill And Auto Cut Off For The Water Level 3). Should Have A Minimum And Maximum Water Level Markings 4). Should Have The Standard Connecting Ports For Inspiratory Limb Of Ventilator , Humidification Chamber (Adult). Specifications: 1). Should Be Compatible With Fischer And Paykel Mr 850 Humidifier 2). Should Have Auto Fill And Auto Cut Off For The Water Level 3). Should Have A Minimum And Maximum Water Level Markings 4). Should Have The Standard Connecting Ports For Inspiratory Limb Of Ventilator , Fingertip Pulse Oximeter For Spo2 And Pulse Rate (Pediatrics). Specifications: 1). Should Have Masimo Signal Extraction Technology And Measure-Through Motion And Low Perfusion Technology 2). Should Display Perfusion Index And Pleth Variability Index 3). Should Have Soft Material In The Area Of Contact With Patients Finger Tip , Spo2 Probe Reusable Clip Type (Pediatric) Compatible With Masimo Radical Pulse Oximeter Specifications: 1). Should Be Compatible With Masimo Radical Pulse Oximeter 2). Should Have Soft Material In The Area Of Contact With Patients Finger Tip 3). Should Have A Mechanism To Firmly Bsecure In Place With Adjustablility For Perfect Fit , Spo2 Connecting Cable Between Monitor And Probe Compatible With Masimo Radical Pulse Oximeter Specifications: 1). Should Be Compatible With Masimo Radical Pulse Oximeter 2). Cable Must Be Flexible And Strong 3). Should Have A Rubber Bend Protector On Both Ends , Spo2 Probe Reusable Clip Type (Pediatric) Compatible With Schiller Truscope Multiparamonitor Specifications: 1). Should Be Compatible With Schiller Truscope Multiparamonitor 2). Should Have Soft Material In The Area Of Contact With Patients Finger Tip 3). Should Have A Mechanism To Firmly Bsecure In Place With Adjustablility For Perfect Fit , Spo2 Probe Reusable Clip Type (Pediatric) Compatible With Nihon Kohden Vismo Multiparamonitor Specifications: 1). Should Be Compatible With Nihon Kohden Vismo Multiparamonitor 2). Should Have Soft Material In The Area Of Contact With Patients Finger Tip 3). Should Have A Mechanism To Firmly Bsecure In Place With Adjustablility For Perfect Fit , Spo2 Probe Reusable Watch Type/ Open Rubber Wrap (Pediatric) Compatible With Philips Intellivue Mp 20 Multiparamonitor / Efficia Cm10 Specifications: 1). Should Be Compatible With Philips Intellivue Mp 20 Multiparamonitor / Efficia Cm10 2). Should Have A Mechanism To Firmly Bsecure In Place With Adjustablility For Perfect Fit , Spo2 Connecting Cable Between Monitor And Probe Compatible With Philips Intellivue Mp 20 Multiparamonitor Specifications: 1). Should Be Compatible With Philips Intellivue Mp 20 Multiparamonitor 2). Cable Must Be Flexible And Strong 3). Should Have A Rubber Bend Protector On Both Ends , Spo2 Connecting Cable Between Monitor And Probe Compatible With Schiller Truscope Monitor Specifications: 1). Should Be Compatible With Schiller Truscope Monitor 2). Cable Must Be Flexible And Strong 3). Should Have A Rubber Bend Protector On Both Ends , Spo2 Connecting Cable Between Monitor And Probe Compatible With Nihon Kohden Vismo Multiparamonitor Specifications: 1). Should Be Compatible With Nihon Kohden Vismo Multiparamonitor 2). Cable Must Be Flexible And Strong 3). Should Have A Rubber Bend Protector On Both Ends , Spo2 Connecting Cable Between Monitor And Probe Compatible With Ge Carascape Multiparameter Monitor Specifications: 1). Should Be Compatible With Ge Carascape Multiparameter Monitor 2). Cable Must Be Flexible And Strong 3). Should Have A Rubber Bend Protector On Both Ends , Spo2 Probe Reusable Soft Open Rubber Wrap Type (Pediatric) Compatible With Compatible With Ge Carascape Multiparameter Monitor Specifications: 1). Should Be Compatible With Compatible With Ge Carascape Multiparameter Monitor 2). Should Have A Mechanism To Firmly Secure In Place With Adjustablility For Perfect Fit , Reusable Low Noise Cabled Sensor - Multi Site Sensor Saturation Probe Compatible With Masimo Specifications: 1). Should Be Compatible With Compatible Masimo Monitor 2). Should Have A Mechanism To Firmly Secure In Place With Adjustablility For Perfect Fit , Reusable Low Noise Cabled Sensor - Ear Sensor Saturation Probe Compatible With Masimo Specifications: 1). Should Be Compatible With Compatible Masimo Monitor 2). Should Have A Mechanism To Firmly Secure In Place With Adjustablility For Perfect Fit , Intercostal Drainage Tube Without Trocar- Size 12F Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Markings At Every 1 To 2 Cm Interval 4). Should Have A Ergonically Desiged Tappered Tip To Be Held Firmly With A Forceps 5). Should Have The Universal Connector For Underwater Seal Drainage Bag 6). Should Have A Radio-Opaque Line , Intercostal Drainage Tube Without Trocar: Size 18 F Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Markings At Every 1 To 2 Cm Interval 4). Should Have A Ergonically Desiged Tappered Tip To Be Held Firmly With A Forceps 5). Should Have The Universal Connector For Underwater Seal Drainage Bag 6). Should Have A Radio-Opaque Line , Intercostal Drainage Tube Without Trocar: Size 16 F Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Markings At Every 1 To 2 Cm Interval 4). Should Have A Ergonically Desiged Tappered Tip To Be Held Firmly With A Forceps 5). Should Have The Universal Connector For Underwater Seal Drainage Bag 6). Should Have A Radio-Opaque Line , Intercostal Drainage Tube Without Trocar: Size 14 F Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Markings At Every 1 To 2 Cm Interval 4). Should Have A Ergonically Desiged Tappered Tip To Be Held Firmly With A Forceps 5). Should Have The Universal Connector For Underwater Seal Drainage Bag 6). Should Have A Radio-Opaque Line , Intercostal Drainage Tube Without Trocar: Size 20 F Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have Markings At Every 1 To 2 Cm Interval 4). Should Have A Ergonically Desiged Tappered Tip To Be Held Firmly With A Forceps 5). Should Have The Universal Connector For Underwater Seal Drainage Bag 6). Should Have A Radio-Opaque Line , Intercostal Drainage Bottle (Single Bottle Underwater Seal) Specifications: 1). Should Have Atleast One Litre Capacity 2). Should Be Supplied Along With Connection Tubes 3). Should Have Facility For Hanging To The Patients Cot Or To Be Kept On Level Ground 4). Should Have Marking For Initial Water Level And Measuring Drain Levels In Ml , Endotracheal Tube With Murphy Eye With Uncuff (Size: 2.5 Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-Uncuff (Size 3Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-Uncuff(Size 3.5 Mm Internal Diameter Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-Uncuff(Size 4Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-Uncuff(Size 4.5Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-Uncuff(Size 5Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-Uncuff(Size 5.5Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye - Uncuff(Size 6Mm Internal Diameter) (One Per Pack) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye - Uncuff (Size: 6.5Mm Internal Diameter) (One Per Pack) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphy Eye With Cuffed (Size: 3 Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphy Eye With Cuffed (Size: 3.5 Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphy Eye With Cuffed (Size: 4Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphy Eye With Cuffed (Size: 4.5Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-With Cuff(Size 5Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-With Cuff(Size 5.5Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-With Cuff(Size 6Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube With Murphys Eye-With Cuff(Size 6.5Mm Internal Diameter) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Endotracheal Tube Microcuff. Size: 3 Mm Internal Diameter Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line 7). Should Be Made Of Advanced Microthin Polyurethane Material (10 Microns) 8). Should Be A True High Volume Low Pressure Cuff Effectively Sealing At An Average Pressure Of 10-11 Cm Of Water 9). Anatomically Based Intubation Depth Mark Should Be There That Helps To Place In Correct Position And A Cuff Free Subglottic Zone 10). Should Have Precision Bands (Minimum Of 4) Facilitate And Confirm Optimal Tube Placement 11). Should Be Compatible For Oral And Nasal Intubation And Be Precurved , Endotracheal Tube Microcuff. Size: 3.5 Mm Internal Diameter Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line 7). Should Be Made Of Advanced Microthin Polyurethane Material (10 Microns) 8). Should Be A True High Volume Low Pressure Cuff Effectively Sealing At An Average Pressure Of 10-11 Cm Of Water 9). Anatomically Based Intubation Depth Mark Should Be There That Helps To Place In Correct Position And A Cuff Free Subglottic Zone 10). Should Have Precision Bands (Minimum Of 4) Facilitate And Confirm Optimal Tube Placement 11). Should Be Compatible For Oral And Nasal Intubation And Be Precurved , Endotracheal Tube Microcuff. Size: 4 Mm Internal Diameter Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line 7). Should Be Made Of Advanced Microthin Polyurethane Material (10 Microns) 8). Should Be A True High Volume Low Pressure Cuff Effectively Sealing At An Average Pressure Of 10-11 Cm Of Water 9). Anatomically Based Intubation Depth Mark Should Be There That Helps To Place In Correct Position And A Cuff Free Subglottic Zone 10). Should Have Precision Bands (Minimum Of 4) Facilitate And Confirm Optimal Tube Placement 11). Should Be Compatible For Oral And Nasal Intubation And Be Precurved , Endotracheal Tube Microcuff. Size: 4.5 Mm Internal Diameter Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line 7). Should Be Made Of Advanced Microthin Polyurethane Material (10 Microns) 8). Should Be A True High Volume Low Pressure Cuff Effectively Sealing At An Average Pressure Of 10-11 Cm Of Water 9). Anatomically Based Intubation Depth Mark Should Be There That Helps To Place In Correct Position And A Cuff Free Subglottic Zone 10). Should Have Precision Bands (Minimum Of 4) Facilitate And Confirm Optimal Tube Placement 11). Should Be Compatible For Oral And Nasal Intubation And Be Precurved , Endotracheal Tube Microcuff. Size: 5 Mm Internal Diameter Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line 7). Should Be Made Of Advanced Microthin Polyurethane Material (10 Microns) 8). Should Be A True High Volume Low Pressure Cuff Effectively Sealing At An Average Pressure Of 10-11 Cm Of Water 9). Anatomically Based Intubation Depth Mark Should Be There That Helps To Place In Correct Position And A Cuff Free Subglottic Zone 10). Should Have Precision Bands (Minimum Of 4) Facilitate And Confirm Optimal Tube Placement 11). Should Be Compatible For Oral And Nasal Intubation And Be Precurved , Endotracheal Tube Microcuff. Size: 5.5 Mm Internal Diameter Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line 7). Should Be Made Of Advanced Microthin Polyurethane Material (10 Microns) 8). Should Be A True High Volume Low Pressure Cuff Effectively Sealing At An Average Pressure Of 10-11 Cm Of Water 9). Anatomically Based Intubation Depth Mark Should Be There That Helps To Place In Correct Position And A Cuff Free Subglottic Zone 10). Should Have Precision Bands (Minimum Of 4) Facilitate And Confirm Optimal Tube Placement 11). Should Be Compatible For Oral And Nasal Intubation And Be Precurved , Tracheostomy Tube Uncuffed (Size 2.5 Mm) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Uncuffed (Size 3 Mm) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Uncuffed (Size 3.5Mm) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Uncuffed Size 4Mm Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Uncuffed Size 4.5Mm Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Uncuffed Size 5Mm Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Uncuffed (Size 5.5 Mm Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Uncuffed Size 6 Mm Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Cuffed (Size 3.5 Mm) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Cuffed (Size 4 Mm) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Cuffed (Size 4.5 Mm) Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Cuffed Size 5Mm Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Cuffed Size 5.5 Mm Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Tracheostomy Tube Cuffed Size 6 Mm Specifications: 1). Should Have Atraumatic, Soft, Rounded Edges 2). Should Be Kink Resistant 3). Should Have A Beveled Tip 4). Should Have Size Identification Marking 5). Should Be Competible With Standard Ventilator Circuit Adapter 6). Should Have A Radio-Opaque Line , Disposable Ventilator Circuit With Humidifier Chamber And Water Trap In Expiratory Limb (Paediartic - 15 Mm Internal Diameter). Specifications: 1). Should Be Compatible With Fischer And Paykel Mr 850 Humidifier 2). Should Have Heater Wire In Inspiratory Limb , Disposable Ventilator Circuit With Humidifier Chamber And Water Trap In Expiratory Limb(Neonatal - 10 Mm Internal Diameter). Specifications: 1). Should Be Compatible With Fischer And Paykel Mr 850 Humidifier 2). Should Have Heater Wire In Inspiratory Limb , Disposable Ventilator Circuit With Humidifier Chamber And Water Trap In Expiratory Limb (Adult - 22 Mm Internal Diameter). Specifications: 1). Should Be Compatible With Fischer And Paykel Mr 850 Humidifier 2). Should Have Heater Wire In Inspiratory Limb , Hfnc Nasal Prongs Compatible With Fischer And Packel Airvo2 Optiflow Hfnc System (Neonatal) , Hfnc Nasal Prongs Compatible With Fischer And Packel Airvo2 Optiflow Hfnc System (Infant) , Hfnc Nasal Prongs Compatible With Fischer And Packel Airvo2 Optiflow Hfnc System (Pediatric) Size - L , Hfnc Nasal Prongs Compatible With Fischer And Packel Airvo2 Optiflow Hfnc System (Pediatric) Size - Xl , Hfnc Nasal Prongs Compatible With Fischer And Packel Airvo2 Optiflow Hfnc System (Adult- Small) , Hfnc Nasal Prongs Compatible With Fischer And Packel Airvo2 Optiflow Hfnc System (Adult- Medium) , Hfnc Nasal Prongs Compatible With Fischer And Packel Airvo2 Optiflow Hfnc System (Adult - Large ) , Nonvented Niv Oronasal Mask - Large Size With Head Gear (Demo Mandatory) Specifications: 1). Should Be Compatible With Maquet Dual Limb Breathing Circuit 2). Should Have A Adjustable Head Gear With Velcro Straps 3). Should Have Apropriate Attachment For The Staps On The Mask 4). Should Have Soft Material On Area Of Skin Contact , Nonvented Niv Oronasal Mask -Medium Size With Head Gear (Demo Mandatory) Specifications: 1). Should Be Compatible With Maquet Dual Limb Breathing Circuit 2). Should Have A Adjustable Head Gear With Velcro Straps 3). Should Have Apropriate Attachment For The Staps On The Mask 4). Should Have Soft Material On Area Of Skin Contact , Nonvented Niv Oronasal Mask -Small Size With Head Gear (Demo Mandatory) Specifications: 1). Should Be Compatible With Maquet Dual Limb Breathing Circuit 2). Should Have A Adjustable Head Gear With Velcro Straps 3). Should Have Apropriate Attachment For The Staps On The Mask 4). Should Have Soft Material On Area Of Skin Contact , Vented Niv Oronalsal Mask -Medium Size With Head Gear (Demo Mandatory) Specifications: 1). Should Be Compatible With Maquet Dual Limb Breathing Circuit 2). Should Have A Adjustable Head Gear With Velcro Straps 3). Should Have Apropriate Attachment For The Staps On The Mask 4). Should Have Soft Material On Area Of Skin Contact , Vented Niv Oronasal Mask -Small Size With Head Gear (Demo Mandatory) Specifications: 1). Should Be Compatible With Maquet Dual Limb Breathing Circuit 2). Should Have A Adjustable Head Gear With Velcro Straps 3). Should Have Apropriate Attachment For The Staps On The Mask 4). Should Have Soft Material On Area Of Skin Contact , Reusable Heater Wire For Pediatric Ventilatory Circuit (Inspiratory Limb) Compatible With Fischer And Paykel Mr 850 Humidifier (Demo Needed) , Draw Wire 1.5 Meter Compatible With Fisher And Pakyel Adult Reusable Circuit , Reusable Heater Wire Adaptor (Single) Compatible With Fischer And Paykel Mr 850 Humidifier , Reusable Heater Wire Adaptor (Dual Adapter)Compatible With Fischer And Paykel Mr 850 Humidifier , Airway Temperature Probe Compatible With Fischer And Paykel Mr 850 Humidifier , Endoscopic Biteguard - Pediatric , Endoscopic Biteguard - Adult , Endospcoic Biteguard - Infant , Tracheal Suction Catheter. Size- 6F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of Atleast 50 Cm With A Single Hole At The Tip 3). The Connector End Should Have A Side Hole (Whistle Type) For Control Of Suction , Tracheal Suction Catheter. Size- 8F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of Atleast 50 Cm With A Single Hole At The Tip 3). The Connector End Should Have A Side Hole (Whistle Type) For Control Of Suction , Tracheal Suction Catheter. Size- 10F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of Atleast 50 Cm With A Single Hole At The Tip 3). The Connector End Should Have A Side Hole (Whistle Type) For Control Of Suction , Tracheal Suction Catheter. Size- 12F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of Atleast 50 Cm With A Single Hole At The Tip 3). The Connector End Should Have A Side Hole (Whistle Type) For Control Of Suction , Closed Endotracheal Suction System (Size - 7 Fr) Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of Atleast 50 Cm With A Single Hole At The Tip 3). Should Have A Locking Mechanism When Not Used 4). The Tarnperent Sleeve Should Be Tear Proof , Closed Endotracheal Suction System (Size - 8 Fr) Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of Atleast 50 Cm With A Single Hole At The Tip 3). Should Have A Locking Mechanism When Not Used 4). The Tarnperent Sleeve Should Be Tear Proof , Closed Endotracheal Suction System (Size - 9 Fr) Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of Atleast 50 Cm With A Single Hole At The Tip 3). Should Have A Locking Mechanism When Not Used 4). The Tarnperent Sleeve Should Be Tear Proof , Closed Endotracheal Suction System (Size - 10 Fr) Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of Atleast 50 Cm With A Single Hole At The Tip 3). Should Have A Locking Mechanism When Not Used 4). The Tarnperent Sleeve Should Be Tear Proof , Autoclavable Silicon Self Inflating Resuscitation Bag With Safety Valve- Pediatric (500 Ml) Specifications: 1). Should Be Re-Usable And Autoclavable 2). Should Have A Oxygen Reservoir With Peep Value , Autoclavable Silicon Self Inflating Resuscitation Bag With Safety Valve- Pediatric (750 Ml) Specifications: 1). Should Be Re-Usable And Autoclavable 2). Should Have A Oxygen Reservoir With Peep Value , Autoclavable Silicon Self Inflating Resuscitation Bag With Safety Valve- Pediatric (1500Ml) Specifications: 1). Should Be Re-Usable And Autoclavable 2). Should Have A Oxygen Reservoir With Peep Value , Autoclavable Silicon Self Inflating Resuscitation Bag With Safety Valve- Pediatric (300 Ml) Specifications: 1). Should Be Re-Usable And Autoclavable 2). Should Have A Oxygen Reservoir With Peep Value , Pediatric Sthethoscope. Specifications: 1). Should Have 1 Inch Traditional Bell (Pediatric) And 3/4 Inch Bell (Infant) Combined With Floating Diaphragm With Antichill Rim 2). Should Have Single Lumen Tubing , Pediatric Laryngoscope Macintosh With Blade Sizes 0,1,2,3 With Handle Specifications: 1). Should Have A Replacable Led Light 2). Should Accept Any Standard Aaa Or Aa Battery , Pediatric Laryngoscope Miller With Blade Sizes 0,1,2,3 With Handle Specifications: 1). Should Have A Replacable Led Light 2). Should Accept Any Standard Aaa Or Aa Battery , Pediatric Video Laryngoscope Macintosh With Blade Sizes 0,1,2,3 Specifications: 1). Should Have Atleast Hd Image Quality 2). Should Have Rechargable Lithium Ion Battery With Battery Level Indicator Or Should Accept Standard Aa Or Aaa Battery , Pediatric Video Laryngoscope Miller With Blade Sizes 0,1,2,3 Specifications: 1). Should Have Atleast Hd Image Quality 2). Should Have Rechargable Lithium Ion Battery With Battery Level Indicator Or Should Accept Standard Aa Or Aaa Battery , Laryngoscope Bulb (Led) , Hfov Ventilator Circuit Complete Set With Diaphragm And Water Trap And Pressure Sensor Cable Compatible With Sensormedics A Hfov Ventilator , Reusable Vibrating Mesh Nebuliser, Demo Needed Specifications: 1). Should Be Compatible With Inline Nebulisation For Delivering Aerosols Through Ventilator Circuits 2). Should Have Low Residual Volume In Medication Cup (Average 0.3 Ml Of 3Ml Dose, Fpf) , Etco2 Adapter Compatible Withetco2 Philips Sensors , Etco2 Adapter Compatible Withetco2 Nihon Kohden Sensors , Etco2 Mainstream Sensor Compatible With Philips Efficia Cm 10 Multiparamonitor , Etco2 Mainstream Sensor Compatible With Schiller Truscope Multiparamonitor , Etco2 Mainstream Sensor Compatible With Nihon Kohdenmultiparamonitor , Etco2 Mainstream Sensor Compatible With Maquet Mechanical Ventilator , Etco2 Mainstream Sensor Compatible With Bella Vista Mechanical Ventilator , Portable Ultrasonic Nebuliser Specifications: 1. Should Be Capable Of Functioning For 6-8 Hrs Per Day,2. Should Be Built For Hospital Purpose,3. Should Function In Ultrasonic Principle , Mini Hme Tracheostomy Filters (Mini) Specifications: 1). Should Provide A Combination Of High-Efficiency Heat/Moisture Exchangers (Hme) And Bacterialand Viral Filtration, Rated To 0.027 Microns At 99.999% Or Higher Efficiency. 2). Should Have A Moisture Output: 30Mg/H2o At Tidal Volume Of 6 To 8 Ml/Kg 3). Weight Should Be Less Than 20G 4). Dead Space Should Be Less Than 30Ml 5). Resistance (Cmh2o) Should Be Less Than 225Pa @30 Lpm 6). Filtration Media Type Should Be Electrostat , Esophageal Pressure Monitoring Catheter Compatible With Bella Vista Ventilator , Hfnc Device Filter Specifications: 1). Should Be Compatible With Fisher And Paykel Airvo-Ii Hfnc Machine , Hfnc Breathing Tubing With Nebulizer Port Specifications: 1). Should Be Compatible With Fisher And Paykel Airvo-Ii Hfnc Machine 2). Should Be Suitable With Wide Range Of Flow 2 To 60 L/Min , Hfnc Tracheoatomy Interface Specifications: 1). Should Be Compatible With Fisher And Paykel Airvo-Ii Hfnc Machine 2). Should Be Suitable With Wide Range Of Flow 2 To 60 L/Min , Intranasal Automization Device With Malleable Stylet, Particualte Size 30-100 Microns , Laryngo-Tracheal Automization Device With Malleable Stylet, Particualte Size 30-100 Microns , Helmet For Niv Therapy (Pediatric Size) Specicifications: 1). Should Have Connector For Double Lumen Ventilatory Circuit 2). Should Have Mechanisms To Fix The Helmet Firmly On To The Childs Head 3). Should Be Adjustable To Create Good Seal In Varying Size From Infants To Children , Pediatric Non-Invasive Nasal Mask, Non Vented Specifications: 1). Should Have Connector For Double Lumen Ventilatory Circuit 2). Should Have Mechanisms To Fix Firmly On To The Childs Nose 3). Should Be Adjustable To Create Good Seal In Varying Size From Infants To Children 4). Should Have Cushion Technology And Custom Fit Technology 5). Should Be Competable For Use In Children Between 2 To 12 Years , Nasal Pilliow (Pediatric) Specifications: 1). Should Have Connector For Double Lumen Ventilatory Circuit 2). Should Have Mechanisms To Fix Firmly On To The Childs Nose 3). Should Be Adjustable To Create Good Seal In Varying Size From Infants To Children 4). Should Have Cushion Technology And Custom Fit Technology 5). Should Be Competable For Use In Children Between 2 To 12 Years , Peak Flow Meter , Under Water Sealed Drainage Bag For Single Use Specifications: 1). Should Have A Clearly Marked Initial Level 2). Should Have A Smooth And Kink Resistant Tubing 3). Should Have A Molded Hand Design For Easy Hanging And Carrying 4). Should Have A Individual And Sterile Packing 5). Should Have A Capacity Of Atleast 500 Ml 6). Should Have Marking For Precise Reading Of Drain Output , Under Water Sealed Drainage Container For Single Use Specifications: 1). Should Have A Clearly Marked Initial Level 2). Should Have A Smooth And Kink Resistant Tubing 3). Should Have A Hanging Hook And Also A Floor Stand 4). Should Have A Individual And Sterile Packing 5). Should Have A Single Chamber With A Capacity Of Atleast 500 Ml 6). Should Have Marking For Precise Reading Of Drain Output , Ventilator Tubings Holding Stand Specifications: 1). Should Have At Least 3 Joints With Locking Mechanism To Fix The Position 2). Should Have A Mechanism To Attach Firmly To Ventilator Or To The Bed Frame 3). Should Be Designed To Carry Atleast 4 Kg Weight 4). Should Have Adjustible Tube Holder For Both Adult, Pediatric And Infant Circuit , Inline Mdi Complatible With Pediatric Ventialtory Ciurcuit , Bronchoscope Consumables , Disposable Ambu Bronchoscope Size - Od - 3.8 Mm / Id - 1.2 Mm , Disposable Ambu Bronchoscope Size - Od - 5 Mm / Id - 2.2 Mm , Disposable Ambu Bronchoscope Size - Od - 5.8 Mm / Id - 2.8 Mm , Disposable Bronchoflex Bronchoscope Size - Working Channel 2.8 Mm / Ed - 5.6 Mm (Vortex) , Disposable Bronchoflex Bronchoscope Size - Working Channel 1.4 Mm / Ed - 3.9 Mm (Agile) , Reusable Biopsy Forceps Compatible With 1.2 Mm Working Channel For Olympus Bronchoscope , Disposable Biopsy Forceps Compatible With 1.2 Mm Working Channel For Olympus Bronchoscope , Bronchoscope Cleaning Brush - Long Compatible With Channel Olympus Bronchoscope Evis Exera Iii Bf - Xp190 , Bronchoscope Cleaning Brush - Mediumcompatible With Channel Olympus Bronchoscope Evis Exera Iii Bf - Xp190 , Bronchoscope Cleaning Brush - Short Compatible With Channel Olympus Bronchoscope Evis Exera Iii Bf - Xp190 , Suction Valve Compatible With Channel Olympus Bronchoscope Evis Exera Iii Bf - Xp190 , Biopsy Valve Compatible With 1.2 Mm Working Channel Olympus Bronchoscope Evis Exera Iii Bf - Xp190 , Bronchoscope Suction Cleaning Adapter ( Y Connection With Provision For Suction And Biopsy Adapter)Compatible Witholympus Bronchoscope Evis Exera Iii Bf - Xp190 , Dormia Basket For 1.2 Mm Working Channel Compatible With Channel Olympus Bronchoscope Evis Exera Iii Bf - Xp190 , Disposable Sterile De Lee Mucous Extractor With Adapter For Bronchoscopy. , Bronchoscopy Swivel Elbow Compatible With Channel Olympus Bronchoscope Evis Exera Iii Bf - Xp190 , Gastrointestinalconsumables , Infant Feeding Tube - 6F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of At Least 30 Cm 3). Should Be Soft And Kink Resistant 4). Should Have A Blind End With Multiple Side Holes 5). Should Have A Radio Opaque Line , Infant Feeding Tube - 7F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of At Least 30 Cm 3). Should Be Soft And Kink Resistant 4). Should Have A Blind End With Multiple Side Holes 5). Should Have A Radio Opaque Line , Infant Feeding Tube - 8F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of At Least 30 Cm 3). Should Be Soft And Kink Resistant 4). Should Have A Blind End With Multiple Side Holes 5). Should Have A Radio Opaque Line , Infant Feeding Tube - 9F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of At Least 40 Cm 3). Should Be Soft And Kink Resistant 4). Should Have A Blind End With Multiple Side Holes 5). Should Have A Radio Opaque Line , Infant Feeding Tube - 10F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of At Least 40 Cm 3). Should Be Soft And Kink Resistant 4). Should Have A Blind End With Multiple Side Holes 5). Should Have A Radio Opaque Line , Pigtail Catheter - 8F (Seldinger Technique) Specifications: 1). The Set Should Include At Least Pigtail Catheter, Introducer Needle, 5-10 Ml Syringe, Mini Scalpel, Wire Guide, Serial Dilators 2). Should Have Stepwise Instructions For Use With Labelled Components 3). Should Be Soft And Kink Proof 4). Should A Smooth, Rounded, Atraumatic Edges 5). Should Have A Radio-Opaque Line , Pigtail Catheter - 12F (Seldinger Technique) Specifications: 1). The Set Should Include At Least Pigtail Catheter, Introducer Needle, 5-10 Ml Syringe, Mini Scalpel, Wire Guide, Serial Dilators 2). Should Have Stepwise Instructions For Use With Labelled Components 3). Should Be Soft And Kink Proof 4). Should A Smooth, Rounded, Atraumatic Edges 5). Should Have A Radio-Opaque Line , Pigtail Catheter - 14F (Seldinger Technique) Specifications: 1). The Set Should Include At Least Pigtail Catheter, Introducer Needle, 5-10 Ml Syringe, Mini Scalpel, Wire Guide, Serial Dilators 2). Should Have Stepwise Instructions For Use With Labelled Components 3). Should Be Soft And Kink Proof 4). Should A Smooth, Rounded, Atraumatic Edges , Sengstaken Blakemore Tube 14 F , Sengstaken Blakemore Tube 16 F , Sengstaken Blakemore Tube 18 F , Peg Low Profile Gastrostomy Feeding Tube/ Kitwith Anti Reflux Valve 12 F(Extension Set With Secure Lock, Right Angle Connector And 2 Port Y And Clamp ) , Peg Low Profile Gastrostomy Feeding Tube/ Kitwith Anti Reflux Valve 14 F (Extension Set With Secure Lock, Right Angle Connector And 2 Port Y And Clamp ) , Peg Low Profile Gastrostomy Feeding Tube/ Kitwith Anti Reflux Valve 16 F (Extension Set With Secure Lock, Right Angle Connector And 2 Port Y And Clamp ) , Nasojejunal Tube 5F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of At Least 60 Cm 3). Should Be Soft And Kink Resistant 4). Should Have A Blind End With Multiple Side Holes 5). Should Have A Radio Opaque Line , Nasojejunal Tube 6F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of At Least 60 Cm 3). Should Be Soft And Kink Resistant 4). Should Have A Blind End With Multiple Side Holes 5). Should Have A Radio Opaque Line , Nasojejunal Tube 8F Specifications: 1). Should Have Marking At 1 Cm Interval 2). Length Of At Least 60 Cm 3). Should Be Soft And Kink Resistant 4). Should Have A Blind End With Multiple Side Holes 5). Should Have A Radio Opaque Line , Cardiovascular Consumables , Intravenous Cannula 26 G , Arterial Catheter For Intra Arterial Access With Straight Guidewire And Introducer Needle - 20 G/ 4 F, 6Cm . Specifications: 1). Should Have A Stiff Arterial Catheter, A Needle, Syringe, Guidewire 2). Should Be Kink Free 3). Should Have Provision For Fixing The Line By Sutures , Arterial Catheter For Intra Arterial Access With Straight Guidewire And Introducer Needle - 21 G/ 3 F, 5 Cm . Specifications: 1). Should Have A Stiff Arterial Catheter, A Needle, Syringe, Guidewire 2). Should Be Kink Free 3). Should Have Provision For Fixing The Line By Sutures , Arterial Catheter For Intra Arterial Access With Straight Guidewire And Introducer Needle - 22 G. Specifications: 1). Should Have A Stiff Arterial Catheter, A Needle, Syringe, Guidewire 2). Should Be Kink Free 3). Should Have Provision For Fixing The Line By Sutures , Arterial Catheter For Intra Arterial Access With Straight Guidewire And Introducer Needle - 24 G, 4 Cm Specifications: 1). Should Have A Stiff Arterial Catheter, A Needle, Syringe, Guidewire 2). Should Be Kink Free 3). Should Have Provision For Fixing The Line By Sutures , Arterial Catheter For Intra Arterial Access With Straight Guidewire And Introducer Needle - 24 G, 8 Cm Specifications: 1). Should Have A Stiff Arterial Catheter, A Needle, Syringe, Guidewire 2). Should Be Kink Free 3). Should Have Provision For Fixing The Line By Sutures , Disposable Defibrillator Pads Compatible With Zoll Defibrillator - Pediatric (<10Kg) , Disposable Defibrillator Pads Compatible With Zoll Defibrillator - Adult (>10Kg) , Transparent I.V Site Dressing Size (7X 6Cms) , Transparent I.V Site Dressing Size (11.5 X 8.5 Cms) , Transparent I.V Site Dressing Size (10 X 15 Cms) Or (10 X 12.5 Cms ) , Chlorhexidine Gluconate Iv Securement Dressing (10 X 15.5 Cm) , Chlorhexidine Gluconate Iv Securement Dressing (8.5 X 11.5Cm) , Chlorhexidine Gluconate Iv Securement Dressing (7X 8.5 Cm) , Dial Flow Iv Set , Intravenous Infusion Set With Drip Chamber And Measuring Set (Burette Type) , Intravenous Infusion Set Compatible With Optima V5 Volumetric Infusion Pump , Three Way Stop Cock , Three Way Stop Cock With 10 Cm Extn Lines , Closed Luer Iv Access System -Single Lumen Type-Silicone Split Septum. Unobstructed Fluid Path. No Moving Parts. Transport Housing.15Cm Single Extension Set With Flow Rate 3L/Hr (Demo Mandatory ) , Closed Luer Iv Access System - Bilumen Type-Silicone Split Septum. Unobstructed Fluid Path. No Moving Parts. Transport Housing.15Cm Single Extension Set With Flow Rate 3L/Hr (Demo Mandatory ) , Disposable Pressure Transducer With Flush Device And Connection Tube Compatible With Philips Mp Monitor With Appropriate Ibp Cable Suitable For Philips Monitor (Demo Needed ) , Disposable Pressure Transducer With Flush Device And Connection Tube Compatible With Meditec England Multipara Monitor With Appropriate Ibp Cable Suitable For Meditec Monitor (Demo Needed ) , Iv Extension Line -150 Cm Length Specifications: 1). Female To Male Type , Iv Extension Line -100 Cm Length Specifications: 1). Female To Male Type , High Pressure Extension Line -150 To 200 Cm Length Specifications: 1). Male To Male Type 2). Should Be Compatible For Pressure Monitoring , High Pressure Extension Line -150 Cm Length Specifications: 1). Female To Male Type 2). Should Be Compatible For Pressure Monitoring , High Pressure Extension Line -100 Cm Length Specifications: 1). Female To Male Type 2). Should Be Compatible For Pressure Monitoring , Pressure Monitor Line 10 Cm Extension With 3 Way , Pressure Infuser Bags For Invasive Blood Pressure Monitoring , Nibp Cuff Compatible With Nihon Kohden Vismo Multiparameter Monitor - Neonate Size. (6X 11 Cm) , Nibp Cuff Compatible With Nihon Kohden Vismo Multiparameter Monitor - Infantsize.(9X14 Cm) , Nibp Cuff Compatible With Nihon Kohden Vismo Multiparameter Monitor - Pediatric Size. (14 X 21 Cm ) , Nibp Cuff Compatible With Nihon Kohden Vismo Multiparameter Monitor - Pediatric Size. (18 X 26 Cm) , Nibp Cuff Compatible With Nihon Kohden Vismo Multiparameter Monitor - Adult Size. (27 X 35 Cm) , Disposable Ecg Electrodes-Neonatal Size , Disposable Ecg Electrodes-Pediatric Size , Ecg Paper Compatible With Biocare Ie 12A Ecg Machine(210Mmx150mm) Z Fold Paper A4 , Ecg Gel , Ecg Paper Compatible With Zoll M Series , 3 Lead Ecg Cable For Meditech Monitor , 3 Lead Ecg Cable (Paediatric) Compatible With Philips Intellivue Mp20 / Cm 10 Monitor. , Double Lumen Paediatric Central Venous Catheter - 3.0 F With Length 5 Cm - Seldinger Technique Based. Suture Or Suture Less Fixation Should Be Mentioned Clearly. Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Double Lumen Pediatrics Central Venous Catheter-4.0F With Length 5Cm Or 4F -Length 8Cm (Seldinger Technique) Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Double Lumen Pediatrics Central Venous Catheter-5.0F With Length8cm (Seldinger Technique). Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Double Lumen Pediatrics Central Venous Catheter-7.0F With Length10cm (Seldinger Technique). Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Triple Lumen Pediatrics Central Venous Catheter-4.0F With Length5cm And 4.0F 8Cm (Seldinger Technique). Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Triple Lumen Pediatrics Central Venous Catheter-5.0F With Length 8Cm (Seldinger Technique). Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Triple Lumen Pediatrics Central Venous Catheter-5.5F With Length 8Cm And 5.5Cm 13Cm (Seldinger Technique). Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Triple Lumen Pediatrics Central Venous Catheter-7.0F With Length Length 15To 16Cm (Seldinger Technique). Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Picc Line With Introducer 2F/24G/Length 15 Cm. Specifications: 1). Should Have Catheter, A Needle, Peel-Away Sheath, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Picc Line With Introducer 3 F/20G/Length 15 Cm. Specifications: 1). Should Have Catheter, A Needle, Peel-Away Sheath, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Midline Intravenous Catheter 24 Gauge Specifications: 1). Should Have A Stiff Arterial Catheter, A Needle, Syringe, Guidewire 2). Should Be Kink Free 3). Should Have Provision For Fixing The Line By Sutures , Midline Intravenous Catheter 22 Gauge Specifications: 1). Should Have A Stiff Arterial Catheter, A Needle, Syringe, Guidewire 2). Should Be Kink Free 3). Should Have Provision For Fixing The Line By Sutures , Midline Intravenous Catheter 20 Gauge Specifications: 1). Should Have A Stiff Arterial Catheter, A Needle, Syringe, Guidewire 2). Should Be Kink Free 3). Should Have Provision For Fixing The Line By Sutures , Ecmo Circuit Compatible With Maquet Rotaflow Ecmo System Including Cone (Pediatric) , Pediatric Ecmo Membrane Oxygenator (Pediatric). Specifications: 1). Should Be Made Of Heparin Coated Microporous Polypropylene/Polymethyl Pentane 2). Should Have A Blood Flow Rated Up To 2.8 L, Gas Exchange Rate Up To 5.6 L/Min 3). Surface Area Should Be 0.8 M2 4). Should Be Compatible With Maquet Rotaflow Ecmo System , Elongated Aortic /Arterialperfusion Cannula- Pediatricsize 8F -With Elongated Thin Walled Tip - Vented Type -Depth Markings - Overallat Least9 Inch Longwith Introducer Preferablywith Guide Wire -Sample Required , Elongated Aortic /Arterialperfusion Cannula- Pediatricsize 10F - With Elongated Thin Walled Tip - Vented Type -Depth Markings -Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Sample Required , Elongated Aortic /Arterialperfusion Cannula- Pediatricsize 12F - With Elongated Thin Walled Tip - Vented Type -Depth Markings -Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Sample Required , Elongated Aortic /Arterialperfusion Cannula- Pediatricsize 14F - With Elongated Thin Walled Tip - Vented Type -Depth Markings -Overalat Least9 Inch Longwithintroducer Preferablywith Guide Wire -Sample Required , Femoral Arterialperfusion Cannula(Pediatric) - 8F With Depth Marking, Introducer With Central Lumen - Sample Required , Femoral Arterialperfusion Cannula(Pediatric) - 10F With Depth Marking, Introducer With Central Lumen - Sample Required , Femoral Arterialperfusion Cannula(Pediatric) - 12F With Depth Marking, Introducer With Central Lumen - Sample Required , Femoral Arterialperfusion Cannula(Pediatric) - 14F With Depth Marking, Introducer With Central Lumen - Sample Required , Femoralvenoussingle-Stage Drainage Cannula(Pediatric) - 8F -With Wire Wound Body & Depth Markings - Overall Length Of At Least 19 Cm - With An Introducer And Preferably With A Guidewire Sample Required , Femoralvenoussingle-Stage Drainage Cannula(Pediatric) - 10F -With Wire Wound Body & Depth Markings - Overall Length Of At Least 19 Cm - With An Introducer And Preferably With A Guidewire Sample Required , Femoralvenoussingle-Stage Drainage Cannula(Pediatric) - 12F -With Wire Wound Body & Depth Markings - Overall Length Of At Least 19 Cm - With An Introducer And Preferably With A Guidewire Sample Required , Femoralvenoussingle-Stage Drainage Cannula(Pediatric) - 14F -With Wire Wound Body & Depth Markings - Overall Length Of At Least 19 Cm - With An Introducer And Preferably With A Guidewire Sample Required , Interosseous Needle 15 G, 15 Mm Length(Demo Mandatory) Specifications: 1). Should Have A Adjustable Length Guard 2). Should Have The Stylet 3). Should Have Universal Iv Set/Triway Connection Capabilities With A Screw Lock , Interosseous Needle 15 G, 25 Mm Length (Demo Mandatory) Specifications: 1). Should Have A Adjustable Length Guard 2). Should Have The Stylet 3). Should Have Universal Iv Set/Triway Connection Capabilities With A Screw Lock , Interosseous Needle 15 G, 45 Mm Length (Demo Mandatory) Specifications: 1). Should Have A Adjustable Length Guard 2). Should Have The Stylet 3). Should Have Universal Iv Set/Triway Connection Capabilities With A Screw Lock , Interosseous Needle 18 G (Demo Mandatory) Specifications: 1). Should Have A Adjustable Length Guard 2). Should Have The Stylet 3). Should Have Universal Iv Set/Triway Connection Capabilities With A Screw Lock , Bone Marrow Biopsy Pediatric Size ( 15 G Or 16 G) Specifications: 1). Should Have A Adjustable Length Guard , Bone Marrow Biopsy Pediatric Size ( 18 G ) Specifications: 1). Should Have A Adjustable Length Guard , Pediatric Vein Finder With Led Light In Built With Rechargeable Battery , Light Shielding Extension Lines For Infusion Of Photosensitive Drugs , Renal Consumables , Foleys Catheter (Rubber) - 6F Specifications: 1). Should Come With Stylet 2). Should Have The Inflating Volume And Size Mentioned On The Catheter 3). Should Have A Radio Opaque Line , Foleys Catheter (Silicone) - 6F Specifications: 1). Should Come With Stylet 2). Should Have The Inflating Volume And Size Mentioned On The Catheter 3). Should Have A Radio Opaque Line , Foleys Catheter (Silicone) - 8F Specifications: 1). Should Come With Stylet 2). Should Have The Inflating Volume And Size Mentioned On The Catheter 3). Should Have A Radio Opaque Line , Foleys Catheter (Rubber) - 8F Specifications: 1). Should Come With Stylet 2). Should Have The Inflating Volume And Size Mentioned On The Catheter 3). Should Have A Radio Opaque Line , Foleys Catheter (Rubber) - 10F Specifications: 1). Should Come With Stylet 2). Should Have The Inflating Volume And Size Mentioned On The Catheter 3). Should Have A Radio Opaque Line , Foleys Catheter (Rubber) 12F Specifications: 1). Should Come With Stylet 2). Should Have The Inflating Volume And Size Mentioned On The Catheter 3). Should Have A Radio Opaque Line , Foleys Catheter (Rubber) - 14F Specifications: 1). Should Come With Stylet 2). Should Have The Inflating Volume And Size Mentioned On The Catheter 3). Should Have A Radio Opaque Line , Urine Collecting Bag Without Uroflow Meter (To Be Attached To Foleys Catheter) , Urine Collecting Bag With Uroflow Meter (To Be Attached To Foleys Catheter) Specifications: 1). Should Have A Separate Measuring Chamber With Markings For Amount Of Urine 2). Minimum Marking In The Chamber Should Be At Least 5 Ml 3). Should Have A Mechanism To Empty By A Release Valve , Neonatal Urine Collecting Bag-Adhesive Type , Peritoneal Dialysis Straight Stiff Catheter(Infant) Specifications: 1). Should Come With The Catheter, Connecter With Mechanism To Stop Flow 2). Should Have A Marking Starting After The Perforated Part 3). Should Have A Soft, Atraumatic And Smoothened Edges , Peritoneal Dialysis Straight Stiff Catheter(Pediatric) Specifications: 1). Should Come With The Catheter, Connecter With Mechanism To Stop Flow 2). Should Have A Marking Starting After The Perforated Part 3). Should Have A Soft, Atraumatic And Smoothened Edges , Peritoneal Dialysis Straight Stiff Catheter(Adult) Specifications: 1). Should Come With The Catheter, Connecter With Mechanism To Stop Flow 2). Should Have A Marking Starting After The Perforated Part 3). Should Have A Soft, Atraumatic And Smoothened Edges , Peritoneal Dialysis Fluid 1 Litre Bottle 1.7% Dextrose , Peritoneal Dialysis Fluid 2 Litre Bag 1.5 % Dextrose , Crrt Replacement Fluid Bags (5 L) Compatible With Fresenius And Prismaflex Crrt Machine , Crrt Replacement Fluid Bags With Citrate (5 L) Compatible With Fresenius And Prismaflex Crrt Machine , Double Lumen Hemodialysis Catheter Kit (Pediatric) 6.5F - 12Cm Specifications: 1). Should Have Hd Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Double Lumen Hemodialysis Catheter Kit (Pediatric) 8.5F - 12Cm Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Double Lumen Hemodialysis Catheter Kit (Pediatric) 10 F - 12Cm Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Double Lumen Hemodialysis Catheter Kit (Pediatric) 11.5F - 12Cm Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Tunnelled Hemodialysis Catheter Kit - 10 F Specifications: 1). Should Have Central Venous Catheter, A Needle, Syringe, Appropriate Spring Guide Wire, Dilator, Suture Less Fixator, Catheter Clamp And Fastener. 2). Should Be Kink Free , Automatic Kidney Biopsy Gun 18 G - 16 Cm (Pediatrics) , Automatic Kidney Biopsy Gun 18 G - 25 Cm (Pediatrics) , Automatic Kidney Biopsy Gun 20 G - 16 Cm (Pediatrics) , Plasma Filter P1dry Surface Area 0.3 , Plasma Filter P1dry Surface Area 0.6 , Crrt Circuit Compatible With Prismaflex Crrt Machine (Hf 20) , Crrt Circuit Compatible With Prismaflex Crrt Machine (M60) , Crrt Circuit Compatible With Prismaflex Crrt Machine (M100) , Crrt Tpe 2000 Set Compatible With Prismaflex Crrt Machine (Effective Surface Area 0.35 ) , Crrt Pediatric Circuit (Complete Set) Compatible With Fresinus Crrt Machine With Filter. Demo Mandatory , Crrt Infant Circuit Compatible (Complete Set) With Fresinus Crrt Machine With Filter. Demo Mandatory , Crrt Adult Circuit Compatible (Complete Set)With Fresinus Crrt Machine With Filter.Demo Mandatory , Hemodialysis Pediatric Circuit With Priming Volume Should Be Less Than 60 Ml , Hemodialysis Pediatric Circuit With Priming Volume Should Be Between 100 To 120 Ml , Polysulfone Synthetic Membrane Low Flux Hollow Fibre Dialyser With Detachable Headers, Gamma Sterilised With Effective Surface Area 0.2 M2 , Polysulfone Synthetic Membrane Low Flux Hollow Fibre Dialyser With Detachable Headers, Gamma Sterilised With Effective Surface Area 0.8 M2 , Polysulfone Synthetic Membrane Low Flux Hollow Fibre Dialyser With Detachable Headers, Gamma Sterilised With Effective Surface Area 1M2 , Hemoadsorption Filter (Carbon Or Resin Based) Demo Mandatory , 5 Micron Carbon Filter Compatible With Nav Portable Ro Plant For Hemodialysis , 20 Micron Carbon Filter Compatible With Nav Portable Ro Plant For Hemodialysis , Ultrasound Consumables , Sterile Ultrasound Probe Cover With Sterile Gel (Demonstration Mandatory ) , Ultrasound Probe Cleaning Wipes , Ultrasound Gel , Side Lab Consumables , Blood Ketone Measuring Strips Specifications: 1). Each Stip Should Be Covered With Separate Water And Moisture Resistant Folder 2). Ketometer Should Be Provided Free 2). Should Be Compatible With Ketometer Provided , Point Of Care Inr/Pt Test Strips. Compatible Device Should Be Provided Free Of Cost. Demonstration Is Mandatory , Point Of Care Ammonia Test Strips , Compatible Device Should Be Provided Free Of Cost. Demonstration Is Mandatory , Neubauer’S Cell Counting Chamber (For Rbc & Wbc Counting) , Glucostrips To Measure Blood Sugar Value At Bedside. - Compatible Glucometer Should Be Provided At Free Of Cost (50 Strips/Box) Quantity In Number Of Boxes , Cover Glass 24X24 Mm Quanitity In Number Of Units (25 Cover Slips/Units) , Benedicts Reagent Pack Of 5 L , Microesr Tube Capillary Tube (Should Be Heparinised),Should Be Capable Of Withstanding Centrifuge With 3000Rpm For 5 Minutes Quantity Number Of Capillary Tubes , Urine Test Strip-Multipurpose (Protein, Blood, Ph, Leukocte, Nitrate, Glucose, Urobilinogen, Ketone,Bilirubin, Specfic Gravity) (25 Strips/Box) Quantity In Number Of Boxes , Urine Test Strip -Ketone(25 Strips/Box) Quantity In Number Of Boxes , Osmometer Calibration Std 1500 Msom/Kg Compatible With Model 3250 (Advanced Instruments) Quantity In Number Of Boxes , Osmometer Calibration Std 100 Msom/Kg Compatible With Model 3250 (Advanced Instruments) Quantity In Number Of Boxes , Osmometer Calibration Std 290 Msom/Kg Compatible With Model 3250 (Advanced Instruments) Quantity In Number Of Boxes , Osmometer Air Filter Compatible With Model 3250 (Advanced Instruments) Quantity In Number Of Boxes , Disposable Sample Tubes Compatible With Osmometer Model 3250 (Advanced Instruments) , Act Tube 0.5 Ml Compatible With Mini Ii Helena Laboratory , 5-Sulfosalicylic Acid (Salt Form) Requirement In Packets (500G/Packet) , Hemoblobin Microcuvettes Strips Specifications: 1). Should Be Competible With Hemocue Hb 201+ Analyser Quantity In Number Of Boxes (50 Strips/Box) , Mini Diluent Box (10 L) Specifications: 1). Should Be Competible With Horibas Microsemi Machine , Lyscbio Reagent Box (400 Ml) Specifications: 1). Should Be Competible With Horibas Microsemi Machine , Cleaner Solution (1 L) Specifications: 1). Should Be Competible With Horibas Microsemi Machine , Crp Reagent (1 Unit Should Be Do 50 Crp Tests) Specifications: 1). Should Be Competible With Horibas Microsemi Machine , Urine Albumin And Glucose Strips Quantity In Number Of Boxes (25 Strips/Box) , Neurologicalconsumables , Eeg Electrode Paste Compatible With Nihon Kohden Neurofac Eeg-1200 Eeg Machine , Eeg Skin Preparation Gel Compatible With Nihon Kohden Neurofac Eeg-1200 Eeg Machine , Eeg Electrodes Compatible With Nihon Kohden Neurofac Eeg-1200 Eeg Machine, Quantity In Sets , Pediatric Regional Oxymetry (Nirs) Sensors Compatible With Masimo O3 Module Specifications: 1). Should Not Be Made With Natural Rubber Latex , Led Pen Torch Light - Yellow/White Light , Strain Guage Icp Catheter Compatible With Codman Icp Monitor , Haematological Consumables , Single Donor Platelet Preparation Kit , Rainbow Masimo Probe With Sphb, Spmet And Spo2 , Miscellaneous , Rectal Temperature Sensor With Cable Compatible With Philips Effacia Cm10/ Mp20multipara Monitor , Air Mattress For Bed Sore Prevention With Motor Pump Specifications: 1). Should Be Automatically Alternating Infation And Deflation , Hydrocolloid Sterile Dressing 10 X 10 Cm (Demo Needed) , Warmer Blanket Half Length Specifications: 1). Should Be Compatabile With Covidien Warm Touch Covective Warming Unit , Warmer Blanket Full Length Specifications: 1). Should Be Compatabile With Covidien Warm Touch Covective Warming Unit , Gel Cushion For Pressure Sore Prevention Approx 45 X 40 Cm With 5 Cm Thickness , Infantometer With Height Measuring Scale Specifications: 1). Should Have A Sleek Broad Acrylic Base With One Sliding Side Adjustable As Per Length Of Baby 2). Should Have Dual Scale For Direct Reading In Cm Or Inches Upto 90Cm 3). Should Have A Folding Sides For Easy Storage 4). Should Have A Minimum Size Of 18” X7”(Length X Width) , Electronic Kitchen Weighing Scale Specifications: 1). Should Be Able Measure Weight In Range Of 1G-5000 G 2). Should Have Easy Function To Reset Scale To Zero 3). Should Have Clear Lcd Display Screen With Large Font 4). Should Have Auto-Off Feature 5). Preferable To Have A Rechargable Battery , Infant Digital Weighing Machine With Tray For Holding Baby. Specifications: 1). Should Have A Range Upto 20Kg With Accuracy Of 5G 2). Should Be Designed Such That Infant Will Not Fall Out Of It 3). Calibration Details If At All Needed Should Be Clearly Mentioned 4). Preferably Rechargable Battery , Handeheld Aneroid Sphygmomanometer Light Weight, Shock Resistant, 3 Cuff Sizes- Infant, Pediatric Adult, Warranty For 5 Years , Electronic Digital Weighing Scale Specifications: 1). Should Have Platform Type With Sturdy Mettalic Build 2). Should Have Weighing Capacity 150 Kg With Accuracy Of 10 Gm 3). Should Have Power Supply 230 V Ac, 50Hz 4). Calibration If Required Should Be Clearly Mentioned Step By Step , Induction Stove Cooktop Specifications: 1). Should Have A Operating Power Atleast 200 Watt And Voltage Of 220-240 V 2). Should Have A Cord Length Should Be At Least 1 M 3). Should Have Microcrystal Plate For Placing Utensils 4). Should Have Touch Start, Auto Off Program And Time Setting , Gaiters Lower Limb With A Thigh Circumference Of 25 To 28 Cm, Knee Circumference Of 20 To 25 Cm, Calf Circumferance Of 18 To 23 Cm And Length Of 25 To 30 Cm , Gaiters Lower Limb With A Thigh Circumference Of 15 To 20 Cm, Knee Circumference Of 13 To 18 Cm, Calf Circumferance Of 15 To 20 Cm And Length Of 20 To 25 Cm , Gaiters Lower Limb With A Thigh Circumference Of 30 To 35 Cm, Knee Circumference Of 20 To 25 Cm, Calf Circumferance Of 20 To 25 Cm And Length Of 35 To 40 Cm , Rollator Walker Specifications: 1). Should Be Light Weight And Foldable 2). Should Have A Fixed Front Wheels To Eliminate Side Motion 3). Should Have Height Adjsut From 70 To 80 Cm 4). Each Handle Bar Should Be Induviually Adjustable For An Exact Fit 5). Should Have Powder Coated Finish , Walker With Wheels Specifications: 1). Should Have A Sturdy Frame And Foldable 2). Should Have Roatating Front Wheels For Easy Movements 3). Should Have Easy Push Button Mechanism For Folding 4). Should Have A Adjsutable Walker Height From 70 To 80 Cm (From The Ground To The Walker Hand Grips) , Cerebral Plasy Chair Cum Standing Frame Specifications: 1). Should Have A Standing Frame With A Wide Secure Base For Stability 2). Should Have A Activity Table And Foot Separator 3). Should Have A Adjsutable Standing Height Between To 100 To 110 Cm 4). Should Hava A Adjsutable Activity Table Height Ranging From 65 To 75 Cm , Prader Orchidometer , Electro Cautery Machine With Both Monopolar And Bipolar Specifications: 1). Output Of Monopolar Should Be Atleast 200 W 2). Should Meet Us Fda, European Ce Safety And Quality Standard 3). Should Have Atleast 3 Bipolar Modes 4). Should Come Along With A Trolley With Lockable Castor Wheel 5). Should Be Supplied With Following Accesories; Hand Switching Pencil: Reusable-2Numbers, Single Use-25Numbers; Pediatric Size Reusable Plate -2 Numbers, Single Use- 30 Numbers; Bipolar Forceps 1 Number; Forceps Cord 1 Number; Foot Switch With 2 Pedals - Monopolar Cut, Coagulation, Bipolar - Should Be Waterproof/ Explosion Proof , Portable Ot Light- Led Technology Specifications: 1). Range Of Light Intensity At 1 Meter Distance Should Be 160000 ± 5000 Lumens 2). Range Of Colour Temperature 3800-4800, 3700-4500 Kelvin 3). Range Of Illuminated Field Should Be 200-400, 150-300 Mm In Diameter 4). Should Have Manual Or Touch Control Panel To Adjust Intensity 5). Should Have Battery Backup Of Minimum Of 1 Hour , Portable Infant Warmer Specifications: 1). Shouldnt Require Continuous Power Supply 2). Maintains Temperature At 37 Degree C For 4 Hrs 3). Should Be Resuable , Silicone Manual Breast Pump , Nibp Cuff Compatible Withphilips Intellivue Mp 20 Multiparameter Monitor - Neonate Size. (6X 11 Cm) , Nibp Cuff Compatible With Philips Intellivue Mp 20 Multiparameter Monitor - Infant Size. (9X 14 Cm) , Nibp Cuff Compatible With Philips Intellivue Mp 20 Multiparameter Monitor - Pediatric Size. (14X 21 Cm) , Nibp Cuff Compatible With Philips Intellivue Mp 20 Multiparameter Monitor -Pediatric Size. (18X 26 Cm) , Nibp Cuff Compatible Withphilips Intellivue Mp 20 Multiparameter Monitor - Adult Size. (27X 35 Cm) , Nibp Cuff Compatible Withefficia Cm 10 Multiparameter Monitor - Neonatal Size. (6X 11 Cm) , Nibp Cuff Compatible Withefficia Cm 10 Multiparameter Monitor - Infant Size. (9X 14 Cm) , Nibp Cuff Compatible Withefficia Cm 10 Multiparameter Monitor - Pediatric Size. (14X 21 Cm) , Nibp Cuff Compatible Withefficia Cm 10 Multiparameter Monitor - Pediatric Size. (18X 26 Cm) , Nibp Cuff Compatible With Efficia Cm 10 Multiparameter Monitor - Adult Size. (27X 35 Cm) , Nibp Cuff Compatible Withmeditech England Multiparameter Monitor - Neonatal Size. (6X 11 Cm) , Nibp Cuff Compatible Withmeditech England Multiparameter Monitor - Infant Size. (9X 14 Cm) , Nibp Cuff Compatible Withmeditech England Multiparameter Monitor - Pediatric Size. (14X 21 Cm) , Nibp Cuff Compatible Withmeditech England Multiparameter Monitor - Pediatric Size. (18X 26 Cm) , Nibp Cuff Compatible Withmeditech England Multiparameter Monitor - Adult Size. (27X 35 Cm)

Key Value

Document Fees
INR 590 /-
EMD
INR 5000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail