Supplying, Fixing, Testing And Commissioning Of 160Kva Diesel Generator And Allied Works For The Allama Iqbal Library, University Of Kashmir , Supplying, Installation, Testing And Commissioning Of Silent Diesel Generator Set 160 Kva, 3 Phase, 50 Hz Silent Dg Set With, Comprising Of Diesel Engine &Alternator As Per Standards, Three Phase, 415V, 50 Hz Both Mounted And Aligned On A Common Ms Base Frame Complete With Inbuilt Standard Panel, Mccb, Fuel Tank, Residential Exhaust Silencer, Battery Set As Required, Avm Pads,Battery Lead What So Ever Required Fitted In Sound Proof Acoustic Enclosure Approved By Cpcb Iv Normes, Including 1St Fill Lube Oil, In All Respects As Required. Cold Starting Kit Is Mandatory Keeing In View Temperature Conditions In Srinagar. Including Two Years Comprehensive Amc Note: The Companyshould Have An Established Service Center In The Valley Since From Last 7 Years With Satisfactory Performance. , Supply, Laying Of Isi Marked Aluminium Conductorxlpe Insulated Cable As Per Is 7098, Un Armoured, Served, Sheathed1100 Volts Grade. 240Sqmm 3 1/2 Core , Supplying And Making End Terminationwith Brass Compression Glands Of Following Sizes Of 1.1. Kv Grade Multicore Aluminium Conductor Pvc Insulated And Pvc Sheathed , 3½ X 240 Sq. Mm , 3½ X 70 Sq. Mm , Supply Of Advance Maintenance Free Chemical Gel Earthing Of Dual Pipe Technology (Gi) Of 3 Mtrs Long 80 Mm Dia Of Outer Shell (Ms) With The 50 Mm Dia Of Inner Shell (Ms) Of 80-100 Microns Galvanized Chemrode Filled With Highly Conducting Metallic Compounds With The Permenant Sealings At Both The Ends With The Lead Terminal Of 50X10mm Size At The Top. The Electrode Shall Be Duly Tested And Certified By Cpri (Central Power Research Institute), Govt Of India For A Peak Short Circuit Withstanding Capacity Of 60 Ka. Including Supply/ Fixing Of Environment Friendly Rust Proof Heavy Duty Weather Proof Polyplastic Earth Pit Chamber. , Supplying And Laying 25 Mm X 5 Mm G.I. Strip At 0.50M. Below Ground Level As Strip Earth Electrode, Including Soldering Etc. As Required. , Providing And Fixing Of Gi Tape 20Mm X 3Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor As Required. , Foundation Construction Offoundation For 160 Kva Dg(As Required At Site) Of 2.5 Feet Above Groundand 2 Feet Below Ground Level, Size (8 Feet X 14 Feet ). Excavating/ Steel Bars/ Reinforced Cement Concrete Work In Well-Staining, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii): 3 Graded Stone Aggregate 20 Mm Nominal Size).Along With Fence Around The Foundation As Required As Per Site, Complete In All Respects. , Providing, Fixing Of Manual Busbar Chamber 4P Type, Hinged Type Single Door, Surface Type 400 Amp4 Way Including Connections As Requied. , Change Over Panel. Supply, Installation, Testing And Commissioning Of Lt. Change Over Paneltotally Enclosed ,Indoortype, Free Standing Type (1 Meter Stand Height), Dust, Damp And Vermin Proof Main Distribution Board Complete With Busbars, Lt. Danger Notice Plate,Multifunction Meter Indicating Lamps, Cts, Interconnections, With Suitable Capacity Aluminium Leads / Solid Aluminium Strips / Rods, Connection Of Incoming And Outgoing Cables With Thimbles, Stove Enamelled Painted And Having Following Incoming And Outgoing Mccb & Mcbs Complete As Required. 2 No.250 Amp Tpn Mccb Release Of 36Ka Adjutable. 1 No.400 Amp Tpn Busbar 1 No. 400A, 3Phase Change Over Front Panel Mount On Load Type. Volt Meters And Selector Switches R,Y,Bled Phase Indicating Lamp With Mcb Protection. Suitable Ratting Busbarsfor Each Segment , Note. The Quoted Percentage (%Age) Should Preferably Be In Fractional Form In Order To Minimize Concurrence Of Similar Quoted Rates