}

Tender For Conversion Of Lt Supply To Ht Supply In Te Harbour, harbour-Tamil Nadu

Bharat Sanchar Nigam Limited has published Tender For Conversion Of Lt Supply To Ht Supply In Te Harbour. Submission Date for this Tender is 29-10-2024. Electrification Work Tenders in harbour Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

45860629
Tender For Conversion Of Lt Supply To Ht Supply In Te Harbour
Open Tender
NCB
Tamil Nadu
Harbour
29-10-2024

Tender Details

Tender For Conversion Of Lt Supply To Ht Supply In Te Harbour; 1 Supply & Laying3 core 120 Sq mm, XLPE aluminium conductor cable of 11KV grade (in Open air / Duct) complete as per specifications/relevant IS standards etc as required 2 Supply and Making indoor cable end termination with heat shrinkable jointing kitcomplete with all accessories as per standard suitable for 3 core 120 Sqmm size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 3 Supply and Making cable straight throughtermination with heat shrinkable jointing kitcomplete with all accessories as per standard suitable for 3 core 120 Sqmm sizeof 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 4 Supply & Fixing of temperature scanner in the transformer with following provisions/ specifications as required Temperature indication range: – 50 to 300 °C.Four relay outputs for Fault, Fan, High (Alarm) & Very High (Trip). Independent set of set points for 4th Channel. 4-20mA output for remote temperature indicationAux. Supply: 85-270 VAC/DC (Optionally 20-50 VAC/DC). (Make: Pecon/Similar Superior make) 5 S/F of4.5 Kg CO2 type Fire extinguisher i/c initial filling, with suitable hose pipe and hook etc as required. ( ISI marked) 6 Removing of UG cable of various sizes from existingduct/panel/ trench/ tray etc i/c untangling, identifying, utilisation/rolling and shifting to directed place inside the compound and connected works etc as required. 7 Upto 35 sqmm 8 Above 35 sq. mm and upto 95 sq. mm 9 Above 95 sq. mm and upto 185 sq. mm 10 Above 185 sq. mm and upto 400 sq. mm 11 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 12 4 X 16 sq. mm 13 4 X 25 sq. Mm 14 3½ X 95 sq. mm 15 3½ X 120 sq. mm 16 3½ X 240 sq. mm 17 Recovering and fixing 25 mm x 5 mm copper strip on surface or in recess for connections i/c GI Coating/applying black paint in exposed areas etc. as required 18 Supply and fixing of2A HRC fuse in existing LT paneletc as reqd. 19 Supply and fixing of0 - 15 KVVoltmeter of size 96x96 in existing HT panel etc as reqd. 20 Supply and fixingspace heater (existing fualty make and model)in existing HT panel etc as reqd. 21 SITC of power pack unit 230 V AC to 110 V DC (100W-S) along with the 12 V 7 AH mtnce free battery for tripping & controlling of the HT panel etc as required. 22 SITC of 380 mm sweep heavyduty Exhaust fan suitable for 230 V Single Ph power supply i/c interconnection & fixing it in existing opening etc as reqd. (Make: Almonard /Crompton/Khaitan / Havells /Smlr Superior make ) 23 Supply & fixing of Door knobs with keysin existing LT panel etc as required. 24 Providing2 Lock & 1 key sets for interlocking of ACBs of schneider/L&T makes i/c suitable arrangements etc as required. 25 Servicing of 3 panel 11 KV HT switchboard i/c cleaning contacts, verifying ON/OFF operations with rectifying the mechanism faults, setting right any minor arrangements cleaning the terminals, greasing, verifying proper functioning, cleaning the dust, testing for insulation value and operational mechanisms and commissioning etc as required 26 Complete 2 coat Enamel Painting for the HT VCB 3 Panel , including replacing of faulty door hinges, door locks, sealing gaskets & hardwares as per the instructions of the site incharge etc as reqd 27 Carrying out injection testing of Over current and earth fault (IDMT) relay operation with primary / Secondary current injection, adjusting /calibration of relays and verifying proper functioning, setting up discriminationetc as required 28 Carrying out following Pre-commissioning Tests of 1250 KVA, 11 KV/433 Volts , Dry type Transformer by disconnecting Primary & secondary connections, i/c isolation etc as required.a. Ratio testb. Magnetic Balance check c. Vector testd. Insulation valuee. Back Feed test 29 Servicing ofACBs of rating 800/2500/4000 Amps ratings i/c checking of ACBs for operating mechanism and applying lubricants for mechanism as required, cleaning of switches with blowers, tightening of bolts and nuts, checking of insulation, loose connection of cable terminations, control wiring etc. as required. 30 Fixing of existingGI cable ladder trays of various sizes ranging from 300 mm to 600 mmincluding providing required supports/ hanging rods , accessories etc.,as per the site conditions as required.

Key Value

Document Fees
INR 590 /-
EMD
INR 11717.0 /-
Tender Value
INR 5.85 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail