}

Tender For Rate Contract Of Arthoscopic Implant For One Year For Government Rajindra Hospital, Patiala, Patiala-Punjab

Government Departments has published Tender For Rate Contract Of Arthoscopic Implant For One Year For Government Rajindra Hospital, Patiala. Submission Date for this Tender is 04-11-2024. Rough Finishing Tools Tenders in Patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

45844012
Tender For Rate Contract Of Arthoscopic Implant For One Year For Government Rajindra Hospital, Patiala
Open Tender
Indian
Punjab
Patiala
04-11-2024

Tender Documents

Tender Details

Tender For Rate Contract of Arthoscopic implant for one year for Government Rajindra Hospital, Patiala- 1 Shaver blades for arthroscopy (Assorted sizes and configurations including aggressive shavers) 2 Shaver burr for arthroscopy (Assorted Sizes) 3 Arthroscopic Cannulas for shoulder surgery with flaps/deployable low-profile wing to help prevent cannula “fallout” 4 Passport cannula for knee and shoulder arthroscopic surgery (assorted sizes) 5 Bio composite fenestrated interference screws with diameter of 5 mm to 12 mm of length 25-35mm 6 All Inside Meniscal repair system with pre knotted 2 peek implants mounted on a rigid needle (straight, Curved, or reverse curved) should have an inbuilt depth penetration limiter to prevent the posterior capsule and can be deployed in the meniscus at any angle (360 deployment). (Required instruments such as cannula, depth probe, rasp, Suture cutter must be provided during the case) 7 Disposable suture passer for shoulder arthroscopy preloaded curved needle and self-retrieving the suture with shaft length of approx. 165mm and jaw opening to approx. 17.6mm, with for taking bite of tissue up-to depth 18 mm 8 Disposable suture passer for knee arthroscopy surgery, preloaded curved needle and self-retrieving the suture with shaft length of approx. 165mm and jaw opening to approx. 12.5mm, with for taking bite of tissue. 9 Titanium endobutton with atleast one accessory sutures for femoral fixation with the adjustable loop, size ranges from 10-105 mm and graft cradle. 10 Titanium button with one accessory sutures for tibial fixation with the adjustable loop, size ranges from 10-105 mm and graft cradle for during all inside ACL/PCL reconstruction 11 Titanium endobutton with one pulling suture and one flipping suture for femoral fixation with the Fixed braided loop, size ranging from 10-40 mm for ACL/PCL reconstruction. 12 Suture washer size ranging from 15 to 17mm dia 13 Femoral fixation device for use in conjunction with any button device, which covers an area of femoral tunnel from 6 to 10 mm area to provide an effective solution for cortical blowouts during femoral tunnel drilling. 14 Fibre wire #2-0, suture and needle assembly (Assorted colour) 15 Fibre wire #1, suture and needle assembly (Assorted colour) 16 Fibre wire #2, suture and needle assembly, 38 (Assorted colour) 17 Suture post (Assorted sizes) 18 PEEK interference fenestrated screws with diameter of 6 mm to 12 mm of length 25-35mm for tibial fixation in ACL reconstruction 19 A non-absorbable sterile synthetic smooth flat suture (width 2mm tape type) composed of Ultrahigh molecular weight polyethylene (Assorted colour) 20 Hydroxyappetite coated, bioabsorbable fenestrated interference screw of length 20- 35mm, & diameter 6mm - 12mm 21 1.5-2mm All Suture, soft, double loaded anchor made up of high molecular weight polyethylene braided fibre & preloaded with ultrahigh molecular weight polyethylene braidedsuturesDrill bit and drill guide set should be provided with the implant during the case 22 Self-punching Knotless anchors biocomposite, Fenestrated, size 5mm to 5.5mm, with Internal Suture Locking 23 Self-punching Knotless anchors PEEK, Fenestrated, size 5.0 to 5.5mm, with Internal Suture Locking 24 Transparent Arthroscopy Shoulder Cannula (Assorted sizes) . 25 Minitape for knotless instability (labram repair) Tapers into #2 sutures for ease of use 26 4.75mm to 5mm Bioabsorbable/Biocomposite screw in anchors with open architecture, preloaded at distal end of the anchor with one ultrahigh molecular weight Polyethylene braided fiber wire & a fibretape for rotator cuff repair. 27 Double loaded Metal anchors (Ti) 4.5-5.5mm for shoulder with 4 needles assembly with proximal cutting threads. 28 Single loaded Metal anchors (Ti) 2.5-3mm for shoulder arthroscopy with proximal cutting threads. 29 Double loaded Metal anchors (Ti) 4.5- 5.5mm for shoulder arthroscopy with proximal cutting threads. 30 5mm - 6mm PEEK anchor with open architecture, preloaded at distal end of t anchor with two ultrahigh molecular weight Polyethylene braided fiberwires. 31 All suture anchor of size 2.5mm-3.0 mm, double loaded meant for rotator cuff repair with #2 suture. 32 All suture anchors of size 1.5mm -2mm, single loaded (meant for Bankart and labrum repair) with suture. 33 Suture washer size ranging from 15 to 17mm dia, (Assorted sizes) 34 Soft threaded metal Ti interference Screws (Assorted Sizes) 35 A 5mm to 5.5 mm PEEK Knotless lateral row anchor with two components in the implant, the proximal self-punch in pointed end and the distal screw component which locks the suture within the implant and secure cortical fixation used for Rotator cuff repair. Awl should be provided with the anchor during the case. 36 BiocompositePush lock Knotless anchors 2.0-2.3mm(meant for Bankart and labrum repair) Required drill bit and drill guide should be provided with the anchor during the case. 37 Disposable Osteochondral grafting kit (size 4.5- 8.5) comprising of chisel, tamp and drill bit . Accessory instruments should be provided for case 38 Arthroscopic Radiofrequency probe for shoulder arthroscopy. RF Machine should be provided with the probe during the case 39 Disposable Suture passer for bankart / labral repair surgery left/ right, all angles, assorted sizes 40 Nitinol wire/nitnol shuttling suture for Suture passer 41 Graduated Drill tip passing pin 2.4mm, length, 38 cm 42 Disposable graduated Endoscopic Cannulated Drill bit, 4.5mm 43 Retrograde drill system kit with with retrograde drill bit, approx 2.4mm. Guide Wire and Suture Retriever for All inside acl reconstruction. Retrograde drill bitSize ranging from 6mm to 11mm with increment of 0.5mm 44 Quadriceps tendon Graftrecovery disposable kit 45 Inside out meniscal repair needles with eye at one end 46 Inside out meniscal repair needles with thread at one end 47 Free metal titanium Endo button 48 Free metal titanium suture disc 49 Free metal Titanium Dog ears/T button 50 Disposable arthroscopic suture cutter 51 Complete Package for ACL/PCL (one endobutton +biocomposite interference screw) 52 Complete Package for ACL/PCL (one endobutton +PEEK interference screw) 53 Complete Package for ACL/PCL (one endobutton +metal interference screw) 54 Complete Package for ACL/PCL Reconstruction 2 biocomposite interference screw 55 Rotator cuff repair with 2 anchor sutures and 1 knotless suture 56 Bankart repair with 4 anchors 57 Disposable Needle for suture retrieval for cuff repair 58 Disposable arthroscopic bird beak for suture passage in shoulder surgery( assorted sizes, left/right/up) 59 Disposable Arthoscopic knot pusher 60 Shaver blades for arthroscopy (Assorted sizes and configurations including aggressive shavers) 61 Shaver burr for arthroscopy (Assorted Sizes) 62 Arthroscopic Cannulas for shoulder surgery with flaps/deployable low-profile wing to help prevent cannula “fallout” 63 Passport cannula for knee and shoulder arthroscopic surgery (assorted sizes) 64 Bio composite fenestrated interference screws with diameter of 5 mm to 12 mm of length 25-35mm 65 All Inside Meniscal repair system with pre knotted 2 peek implants mounted on a rigid needle (straight, Curved, or reverse curved) should have an inbuilt depth penetration limiter to prevent the posterior capsule and can be deployed in the meniscus at any angle (360 deployment). (Required instruments such as cannula, depth probe, rasp, Suture cutter must be provided during the case) 66 Disposable suture passer for shoulder arthroscopy preloaded curved needle and self-retrieving the suture with shaft length of approx. 165mm and jaw opening to approx. 17.6mm, with for taking bite of tissue up-to depth 18 mm 67 Disposable suture passer for knee arthroscopy surgery, preloaded curved needle and self-retrieving the suture with shaft length of approx. 165mm and jaw opening to approx. 12.5mm, with for taking bite of tissue. 68 Titanium endobutton with atleast one accessory sutures for femoral fixation with the adjustable loop, size ranges from 10-105 mm and graft cradle. 69 Titanium button with one accessory sutures for tibial fixation with the adjustable loop, size ranges from 10-105 mm and graft cradle for during all inside ACL/PCL reconstruction 70 Titanium endobutton with one pulling suture and one flipping suture for femoral fixation with the Fixed braided loop, size ranging from 10-40 mm for ACL/PCL reconstruction. 71 Suture washer size ranging from 15 to 17mm dia 72 Femoral fixation device for use in conjunction with any button device, which covers an area of femoral tunnel from 6 to 10 mm area to provide an effective solution for cortical blowouts during femoral tunnel drilling. 73 Fibre wire #2-0, suture and needle assembly (Assorted colour) 74 Fibre wire #1, suture and needle assembly (Assorted colour) 75 Fibre wire #2, suture and needle assembly, 38 (Assorted colour) 76 Suture post (Assorted sizes) 77 PEEK interference fenestrated screws with diameter of 6 mm to 12 mm of length 25-35mm for tibial fixation in ACL reconstruction 78 A non-absorbable sterile synthetic smooth flat suture (width 2mm tape type) composed of Ultrahigh molecular weight polyethylene (Assorted colour) 79 Hydroxyappetite coated, bioabsorbable fenestrated interference screw of length 20- 35mm, & diameter 6mm - 12mm 80 1.5-2mm All Suture, soft, double loaded anchor made up of high molecular weight polyethylene braided fibre & preloaded with ultrahigh molecular weight polyethylene braidedsuturesDrill bit and drill guide set should be provided with the implant during the case 81 Self-punching Knotless anchors biocomposite, Fenestrated, size 5mm to 5.5mm, with Internal Suture Locking 82 Self-punching Knotless anchors PEEK, Fenestrated, size 5.0 to 5.5mm, with Internal Suture Locking 83 Transparent Arthroscopy Shoulder Cannula (Assorted sizes) . 84 Minitape for knotless instability (labram repair) Tapers into #2 sutures for ease of use 85 4.75mm to 5mm Bioabsorbable/Biocomposite screw in anchors with open architecture, preloaded at distal end of the anchor with one ultrahigh molecular weight Polyethylene braided fiber wire & a fibretape for rotator cuff repair. 86 Double loaded Metal anchors (Ti) 4.5-5.5mm for shoulder with 4 needles assembly with proximal cutting threads. 87 Single loaded Metal anchors (Ti) 2.5-3mm for shoulder arthroscopy with proximal cutting threads. 88 Double loaded Metal anchors (Ti) 4.5- 5.5mm for shoulder arthroscopy with proximal cutting threads. 89 5mm - 6mm PEEK anchor with open architecture, preloaded at distal end of t anchor with two ultrahigh molecular weight Polyethylene braided fiberwires. 90 All suture anchor of size 2.5mm-3.0 mm, double loaded meant for rotator cuff repair with #2 suture. 91 All suture anchors of size 1.5mm -2mm, single loaded (meant for Bankart and labrum repair) with suture. 92 Suture washer size ranging from 15 to 17mm dia, (Assorted sizes) 93 Soft threaded metal Ti interference Screws (Assorted Sizes) 94 A 5mm to 5.5 mm PEEK Knotless lateral row anchor with two components in the implant, the proximal self-punch in pointed end and the distal screw component which locks the suture within the implant and secure cortical fixation used for Rotator cuff repair. Awl should be provided with the anchor during the case. 95 BiocompositePush lock Knotless anchors 2.0-2.3mm(meant for Bankart and labrum repair) Required drill bit and drill guide should be provided with the anchor during the case. 96 Disposable Osteochondral grafting kit (size 4.5- 8.5) comprising of chisel, tamp and drill bit . Accessory instruments should be provided for case 97 Arthroscopic Radiofrequency probe for shoulder arthroscopy. RF Machine should be provided with the probe during the case 98 Disposable Suture passer for bankart / labral repair surgery left/ right, all angles, assorted sizes 99 Nitinol wire/nitnol shuttling suture for Suture passer 100 Graduated Drill tip passing pin 2.4mm, length, 38 cm 101 Disposable graduated Endoscopic Cannulated Drill bit, 4.5mm 102 Retrograde drill system kit with with retrograde drill bit, approx 2.4mm. Guide Wire and Suture Retriever for All inside acl reconstruction. Retrograde drill bitSize ranging from 6mm to 11mm with increment of 0.5mm 103 Quadriceps tendon Graftrecovery disposable kit 104 Inside out meniscal repair needles with eye at one end 105 Inside out meniscal repair needles with thread at one end 106 Free metal titanium Endo button 107 Free metal titanium suture disc 108 Free metal Titanium Dog ears/T button 109 Disposable arthroscopic suture cutter 110 Complete Package for ACL/PCL (one endobutton +biocomposite interference screw) 111 Complete Package for ACL/PCL (one endobutton +PEEK interference screw) 112 Complete Package for ACL/PCL (one endobutton +metal interference screw) 113 Complete Package for ACL/PCL Reconstruction 2 biocomposite interference screw 114 Rotator cuff repair with 2 anchor sutures and 1 knotless suture 115 Bankart repair with 4 anchors 116 Disposable needle for suture retrieval in shoulder cuff repair 117 Disposable arthroscopic bird beak for suture passage in shoulder surgery (assorted sizes, left/right/up) 118 Disposable Arthoscopic knot pusher

Key Value

Document Fees
INR 5000 /-
EMD
INR 200000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail