}

Tender For (C) Cluster -4 The Work For The Construction Of New 11 Kv Feeder And Its Associated Lt Lines For Separating The Agriculture And Rural Load In Exiting 11 Kv Feeders At Different 33/11 Kv Substations In Muzaffarnagar Zone And Meerut Zone (Distric, meerut-Uttar Pradesh

Government Departments has published Tender For (C) Cluster -4 The Work For The Construction Of New 11 Kv Feeder And Its Associated Lt Lines For Separating The Agriculture And Rural Load In Exiting 11 Kv Feeders At Different 33/11 Kv Substations In Muzaffarnagar Zone And Meerut Zone (Distric. Submission Date for this Tender is 28-10-2024. Bolts Tenders in meerut Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45843472
Tender For (C) Cluster -4 The Work For The Construction Of New 11 Kv Feeder And Its Associated Lt Lines For Separating The Agriculture And Rural Load In Exiting 11 Kv Feeders At Different 33/11 Kv Substations In Muzaffarnagar Zone And Meerut Zone (Distric
Open Tender
Indian
Uttar Pradesh
Meerut
28-10-2024

Tender Documents

Tender Details

tender for (C) Cluster -4 The Work For The Construction Of New 11 Kv Feeder And Its Associated Lt Lines For Separating The Agriculture And Rural Load In Exiting 11 Kv Feeders At Different 33/11 Kv Substations In Muzaffarnagar Zone And Meerut Zone (District Muza, SEGREGATION OF AGRICULTURE FEEDERS ON TURNKEY BASIS IN CLUSTER-IV (MEERUT, SHAMLI & MUZAFARNAGAR DISTRICTS) OF PsVVNL, UTTAR PRADESH UNDER REVAMPED REFORMS- BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME, 1 11kV New Line on 8.5 Mtr. PCC Pole with ACSR Rabbit Conductor 2 PCC Pole, 8.5 Mtr. Long 3 Stone Pad (300x300x75mm) 4 V-Type Cross arm for 11KV Line, 65x65x6 mm, GI Angle 5 Cross arm holding Clamp with nuts & bolts 6 11KV `F Bracket with N&B 7 Supply of ACSR RabbitConductor 8 Erection of ACSR RabbitConductor 9 11kV Polymer Disc Insulator T&C type 45 KN 10 Disc Fittings T&C type 45 KN 11 11 KV Composite Polymer Pin Insulator with Nut and washers as per TS 12 11KV MS Danger Board with clamp, bolts & nuts 13 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 14 Stay Wire 7/10 SWG 15 PG Clamps 16 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 17 Aluminium Jointing Sleeves 18 G.I. Barbed Wire 19 GI Wire 6 SWG 20 GI Wire 8 SWG 21 GI Wire 16 SWG 22 Eye Bolt 23 Turn Buckle 24 11kV E Bracket with N&B 25 GI Top Channel 100x50x2240 mm.With Clamp and NB and washer 26 GI Angle 65x65x6 mm, 2700 mm long bracing complete with clamps, Nut, bolt and washers 27 GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer 28 GI Channel 100x50x6, 1525 mm long ,with clamp, nut,bolt and washer 29 Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 30 Concreting of Pole/Support as per TS 31 11kV New Line on 8.5 Mtr. PCC Pole with ACSR Weasal Conductor 32 PCC Pole, 8.5 Mtr. Long 33 Stone Pad (300x300x75mm) 34 V-Type Cross arm for 11KV Line, 65x65x6 mm, GI Angle 35 Cross arm holding Clamp with nuts & bolts 36 11KV `F Bracket with N&B 37 Supply of ACSR Weasal Conductor 38 Erection of ACSR weasal Conductor 39 11kV Polymer Disc Insulator T&C type 45 KN 40 Disc Fittings T&C type 45 KN 41 11 KV Composite Polymer Pin Insulator with Nut and washers as per TS 42 11KV MS Danger Board with clamp, bolts & nuts 43 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 44 Stay Wire 7/10 SWG 45 PG Clamps 46 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 47 Aluminium Jointing Sleeves 48 G.I. Barbed Wire 49 GI Wire 6 SWG 50 GI Wire 8 SWG 51 GI Wire 16 SWG 52 Eye Bolt 53 Turn Buckle 54 11kV E Bracket with N&B 55 GI Top Channel 100x50x2240 mm.With Clamp and NB and washer 56 GI Angle 65x65x6 mm, 2700 mm long bracing complete with Clamps, Nut, bolt and washers 57 GI Channel 100x50x6 mm. 1300 mm long with clamp, nut,bolt and washer 58 GI Channel 100x50x6, 1525 mm long ,with clamp, nut,bolt and washer 59 Guarding angle 75x75x6 mm, 1600 mm long with holding clamp, packing piece, nut & bolts etc. 60 Concreting of Pole/Support as per TS 61 New LT Line on ACSR Weasel Conductor on 8.5 Mtr. PCC Pole 62 PCC Pole, 8.5 Mtr. Long 63 Stone Pad (300x300x75mm) 64 LT clamp with nut and bolt for PCC pole 65 LT Shakle Insulator 100x115 mm With Nut and Bolt 66 Supply of ACSR Weasel Conductor 67 Erection of ACSR Weasel Conductor 68 Aluminium Jointing Sleeves 69 Earthing complete with M.S. Earthing Rod 20x2500 mm. & GI wire 6 SWG 70 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 71 Stay Wire 7/10 SWG 72 Concreting of Pole/Support as per TS 73 Guarding angle 75x75x6mm.1600 MM long with holding angle 74 G.I Wire 6 SWG along with span 75 G.I Wire 8 SWG 76 G.I Wire 16 SWG for winding 77 Eye Bolt 78 Construction of new 100 KVA, 11/0.433kV Distribution Transformer S/S 79 11/0.44 kV 100 KVA Transformer (Level-I) as per specified in T.S. 80 PCC Pole, 8.5 Mtr. Long 81 Stone Pad (300x300x75mm) 82 GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 83 GI Channel 100x50x2240mm (For TPMO,LA and Fuse set) 84 Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers 85 GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base 86 11kV Polymer Disc Insulator T&C type 45 KN 87 Disc Fittings T&C type 45 KN 88 11 KV Composite Polymer Pin Insulator with clamp and washers as per TS 89 11kV TPMO complete set 90 11kV DO Fuse Set (3 Phase) 91 11kV Lightening Arrestor (Set- 3 No) 92 G.I. Barbed Wire 93 11kV MS Danger Board with clamp, bolts & nuts 94 SMCDistribution boxas per technical specificationsfor 3 Ph 100 KVA DTR 95 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 96 Stay Wire 7/10 SWG 97 Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) as per TS 98 LT PVC Cable3.5x150/70Sq.mm. 99 ACSR Weasel Conductor 100 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 101 GI Channel 100x50x2028mm (ForDistribution box)) 102 Concreting of Pole/Support as per TS 103 Construction of new 63 KVA, 11/0.433kV Distribution Transformer S/S 104 11/0.44 kV 63 KVA Transformer (Level-I) as per specified in T.S. 105 PCC Pole, 8.5 Mtr. Long 106 Stone Pad (300x300x75mm) 107 GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 108 GI Channel 100x50x2028mm (For TPMO,LA and Fuse set) 109 Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers 110 GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base 111 11kV Polymer Disc Insulator T&C type 45 KN 112 Disc Fittings T&C type 45 KN 113 11 KV Composite Polymer Pin Insulator with Nut and washers as per TS 114 11kV TPMO complete set 115 11kV DO Fuse Set (3 Phase) 116 11kV Lightening Arrestor (Set- 3 No) 117 G.I. Barbed Wire 118 11kV MS Danger Board with clamp, bolts & nuts 119 SMCDistribution box as per technical specifications for 3 Ph 63 KVA DTR 120 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 121 Stay Wire 7/10 SWG 122 Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) 123 LT PVC Cable3.5x70/35Sq.mm. 124 ACSR Weasel Conductor 125 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 126 GI Channel 100x50x2028mm (ForDistribution box)) 127 Concreting of Pole/Support as per TS 128 Construction of new 25 KVA, 11/0.433kV Distribution Transformer S/S 129 11/0.44 kV 25 KVA Transformer (Level-I) as per specified in T.S. 130 PCC Pole, 8.5 Mtr. Long 131 Stone Pad (300x300x75mm) 132 GI Top Channel 125x65 mm, 2240 mm with clamp, bolts, nuts and washers 133 GI Channel 100x50x2240mm (For TPMO,LA and Fuse set) 134 Holding Clamps for Top Channel TPMO & Fuse Set etc. with nuts, bolts & washers 135 GI Angle 75x75x6 mm, 2028 mm long with clamp for T/F base 136 11kV Polymer Disc Insulator T&C type 45 KN 137 Disc Fittings T&C type 45 KN 138 11 KV Composite Polymer Pin Insulator with Nut and washers 139 11kV TPMO complete set 140 11kV DO Fuse Set (3 Phase) 141 11kV Lightening Arrestor (Set- 3 No) 142 G.I. Barbed Wire 143 11kV MS Danger Board with clamp, bolts & nuts 144 SMCDistribution boxas per technical specifications for 3 Ph 25 KVA DTR 145 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 146 Stay Wire 7/10 SWG 147 Chemical Pipe Earthing (80 mm dia, 3 m long Pipe) as per TS 148 LT XLPE insulated unarmoured 4x25 Sq. mm.Cable 149 ACSR Weasel Conductor 150 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 151 GI Channel 100x50x2028mm (ForDistribution box)) 152 Concreting of Pole/Support as per TS 153 Installation of 11 KV Outgoing VCB for Feeder Segreration 154 11KV Outgoing CTR 400/200/5A 350 MVA 155 11 KV rearrangement for connecting new 11 KV VCB with existing 11 KV Switch gear (Adoptor Panel) 156 11kV 3x185 mm2XLPE Cable 157 Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 158 Heat Shrinkable indoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 159 11 Mtr. Long Steel Tubular pole 410 SP 55 160 GI Top Channel 100x50x2240 mm. 161 11 KV Polymer Disc Insulator T&C type 45 KN 162 Disc Fitting T&C type 45 KN 163 11 KV Composite Polymer Pin Insulator with Nut and washers 164 P.G. Clamp for ACSR Dog/Raccoon 165 11kV E Bracket with N&B 166 11kV MS Danger Board with clamp, bolts & nuts 167 11kV Lightening Arrestor (Set- 3 No) 168 G.I. Barbed Wire 169 Aluminium Paint 170 Red Oxide Paint 171 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 172 Stay Wire 7/10 SWG 173 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 174 GI Strip 50x6 mm 175 G.I. Pipe 6 dia . 176 Laying of 11 KV Cable including cost of Sand & Bricks 177 Concreting of Pole/Support as per TS 178 PVC 4x2.5 sq mm (Cu) 179 PVC2x2.5 sq mm (cu) 180 Control Room Extension 181 Extension of existing substationcontrol room building,Control Room size 6x6 mtrs.( as per annexure attached in tender documents.) 182 11 KV Railway Crossing 183 11 Mtr. Long Steel Tubular pole 410 SP 55 184 Stone Pad (300x300x75mm) 185 11kV 3x185 mm2XLPE Cable 186 Top channel 125x 65 mm 3200 mm (10,7kg/m) 187 M.S Angle iron 65x65x6 mm 4300 mm long bracing with clamp 188 Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 189 Laying of HDPE Pipe underground minimum 3 meters below the Railway track by HDD Method along with laying of 11 KV 3x185 Sqmm. XLPE Cable in G.I. Pipes. 190 HDPEPipe (6 dia.) for laying UG below the Railway track by HDD Method. 191 G.I. Pipe 6 dia. with Clamps 192 11 KV Polymer Disc Insulator B&S type 70 KN 193 Disc Fitting B&S type 70 KN 194 P.G. Clamp for ACSR Dog/Raccoon 195 11kV MS Danger Board with clamp, bolts & nuts 196 G.I. Barbed Wire 197 Aluminium Paint 198 Red Oxide Paint 199 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 200 Stay Wire 7/10 SWG 201 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 202 Concreting of Pole/Support as per TS 203 Railway Crossing Documentation, Land and Approval Fee etc. (Payment shall be done as per actual) 204 Digging of trench by excavation of earth, laying of bricks to cover the vable and filling of sand & earth ramming and dressing properly with complete job for laying of11 KV XLPE cables 205 Laying of 11 KV XLPE Cable in trenches and in G.I. Pipe on double pole 206 Number plate 207 11 KV Polymer Pin Insulator 208 Cable Route Marker 209 NHAI/State Highway Crossing 210 11 Mtr. Long Steel Tubular pole 410 SP 55 211 11kV 3x185 mm2XLPE Cable 212 Heat Shrinkable outdoor type termination kit suitable for 11kV XLPE 3x185 Sq.mm. cable size 213 HDPE Pipe for cable laying (Pipe to be laid by HDD Method) 214 G.I. Pipe 6 dia . 215 Laying of 11 KV XLPE Cable underground in trenches/ pipes. 216 Laying of 11 KV XLPE Cable in G.I. Pipe on double pole 217 Top channel 125x 65 mm 3200 mm 218 M.S Angle iron 65x65x6 mm 4300 mm long bracing with clamp 219 11 KV Polymer Disc Insulator B&S type 70 KN 220 Disc Fitting B&S type 70 KN 221 P.G. Clamp for ACSR Dog 222 11kV MS Danger Board with clamp, bolts & nuts 223 G.I. Barbed Wire 224 Aluminium Paint 225 Red Oxide Paint 226 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 227 Stay Wire 7/10 SWG 228 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 229 Concreting of Pole/Support as per TS 230 NHAI/State highway crossing documentation, land charges and approval fee etc. (Payment shall be done as per actual) 231 Road Restoration (Foot Path )charges 232 Bolts Nuts & washers 233 Aluminium winding wire - 6 SWG 234 Constructionof NewLTLineon(3x50+1x35+1x16)sq.mmLTABC Cable 235 PCC Pole, 8.5 Mtr. Long 236 Stone Pad (300x300x75mm) 237 Earthing complete with M.S. Earthing Rod 20x2500 mm. & GI wire 6 SWG 238 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 239 Stay Wire 7/10 SWG 240 Dead End clamp (Insulated) 241 Suspension clamps with I-Hook (Insulated) 242 Pole Clamps with nut & bolts for laying ABC 243 LT Insulating Piercing Connector (16sq.mm) suitable for street light 244 Insulating Piercing Connector (120-50 sq.mm -50-35 sq.mm) 245 SMC LT distribution boxes/kiosk, 3 phase on the LTPoles including all clamps & material required for mounting connections 246 Supply of LT ABC of 3x50+1x35+1x16 sq. mm 247 Erection of LT ABC of 3x50+1x35+1x16 sq. mm 248 1x35 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. 249 1x16 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the street light 250 End cap for LT AB cable 251 PG Clamps 252 Concreting of PCC Pole/Support as per TS 253 Construction of New LT line on (3x95 + 1x70 +1x16)sq. mm LT ABC Cable 254 PCC Pole, 8.5 Mtr. Long 255 Stone Pad (300x300x75mm) 256 Earthing complete with M.S. Earthing Rod 20x2500 mm. & GI wire 6 SWG 257 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 258 Stay Wire 7/10 SWG 259 Dead End clamp (Insulated) 260 Suspension clamps with I-Hook (Insulated) 261 Pole Clamps with nut & bolts for laying ABC 262 LT Insulating Piercing Connector (16sq.mm) suitable for street light 263 Insulating Piercing Connector (120-50 sq.mm -50-35 sq.mm) 264 SMC LT distribution boxes/kiosk, 3 phase on the LTPoles including all clamps & material required for mounting connections 265 Supply of LT ABC of 3x95+1x70+1x16 sq. mm 266 Erection of LT ABC3x95+1x70+1x16 sq. mm 267 1x35 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the distribution boxes. 268 1x16 mm2 Un-armoured XLPE insulated Al. LT Cable for energising the street light 269 End cap for LT AB cable 270 PG Clamps 271 Concreting of PCC Pole/Support as per TS 272 Overhead crossing of existing HT Line 273 13 meter STP Pole-SP-70 274 X-arm MS Angle 65X65X6mm V-Type 11 KV 275 Cross arm holding clamps with bolts & nuts 276 11 KVpolymeric Pin Insulator 277 F-bracket for fitting top insulator with bolts & nuts 278 Danger Plate with clamps & bolts 279 Aluminium paint 280 Red oxide paint 281 Number marking on Polewith paint 282 Barbed wire GI 283 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 284 Stay Wire 7/10 SWG 285 Concreting of STP 13 M supports (@.63 Cu Mtr per pole) 286 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 287 Overhead crossing of existing LT Line 288 11 meter STP Pole-SP-55 289 X-arm MS Angle 65X65X6mm V-Type 11 KV 290 Cross arm holding clamps with bolts & nuts 291 11 KVpolymeric Pin Insulator 292 F-bracket for fitting top insulator with bolts & nuts 293 Danger Plate with clamps & bolts 294 Aluminium paint 295 Red oxide paint 296 Number marking on Polewith paint 297 Barbed wire GI 298 Stay Complete (GI Stay Rod 16x1800 mm-1 nos , Eye Bolt -1 nos, Anchor plate -1 nos,Turn Buckle-1 nos, Hellically Formed End Fitting, Square Washer and thimble, Nuts Bolt & Washers , Stay Calmp and Guy Insulator as per approved Drawing and TS 299 Stay Wire 7/10 SWG 300 Concreting of STP 11 M supports (@.44 Cu Mtr per pole) 301 Earthing of pole by MS earthing rod of 20x2500 mm. and 6 SWG earthing wire etc. 302 Additional items that may be required for completion of work 303 9 MTR STP Pole 304 3x120 sq. mm 11 kV AB Cable 305 11kV Polymer Disc Insulator with Fitting for 11 KVABC 306 11kV Polymer Disc Insulators with I-Hook 307 Heat Shrinkable 1 ph. termination kit outdoor for 11 kV 3x120 Sq. mm. AB Cable 308 Spacers LT PVC 309 LT Insulation Piercing Connectors of 95/50 sq. mm - 70/35 sq. mm (For messenger wire jumpering & energizing DB neutral) 310 On/Off switch for street light connections 311 Height raising channel 100X50,2240 mm long 312 Back clamp for height raising channel holding clamps with bolts & nuts

Key Value

Document Fees
INR 11800 /-
EMD
INR 6812000.0 /-
Tender Value
INR 34.06 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail