}

Tender For Work No 01 Design Engineering Development Of Waste To Art (Ceramics Park)With Vgf And O And M On Revenue Sharing Basics., bulandshahr-Uttar Pradesh

Local Bodies has published Tender For Work No 01 Design Engineering Development Of Waste To Art (Ceramics Park)With Vgf And O And M On Revenue Sharing Basics.. Submission Date for this Tender is 14-11-2024. Uniform Tenders in bulandshahr Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45821828
Tender For Work No 01 Design Engineering Development Of Waste To Art (Ceramics Park)With Vgf And O And M On Revenue Sharing Basics.
Open Tender
Indian
Uttar Pradesh
Bulandshahr
14-11-2024

Tender Documents

Tender Details

Tender For Work No 01 Design Engineering Development Of Waste To Art (Ceramics Park)With Vgf And O And M On Revenue Sharing Basics.- 1 TREE - The structure to be made with a minimum area as per below details, using the Ceramic scrap/waste material available at the sites . Minimum Height –15 feet. Minimum Width – 15 feet. Minimum Length – 15 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Construction of the miniature/sculpture to be made from Ceramic Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while Finalizing of miniatures / sculptures Applying/Filling Epoxy of approved quality in the gaps , painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 2 I LOVE KHUJRA - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 8 feet. Minimum Width – 1.5 feet. Minimum Length – 48 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 3 LOVE - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 8 feet. Minimum Width – 1.5 feet. Minimum Length – 25 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 4 ENTERANCE TO THE ZONE - The structure to be made with a minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 15 feet. Minimum Width – 2 feet. Minimum Length – 10 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 5 ENTERANCE TO THE ZONE 2 - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 15 feet. Minimum Width – 2 feet. Minimum Length – 8 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 6 VASE-1- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 10 feet. Minimum Width – 6 feet. Minimum Length – 6 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 7 VASE-2 - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 8 feet. Minimum Width – 6 feet. Minimum Length – 7 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 8 CAR - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 4 feet. Minimum Width – 4 feet. Minimum Length – 8 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 9 RIKSHAW - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 4 feet. Minimum Width – 3 feet. Minimum Length – 6 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 10 BIKE - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 2.5 feet. Minimum Width – 2 feet. Minimum Length – 6 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 11 TEA CUP RIDE - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height –8 feet. Minimum Width – 12 feet. Minimum Length – 12 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 12 CUP TOWER - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 15 feet. Minimum Width – 6 feet. Minimum Length – 6 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 13 CUP HOUSE - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 10 feet. Minimum Width –10 feet. Minimum Length – 15 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 14 KETTLES RIDE - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 8 feet. Minimum Width – 20 feet. Minimum Length – 20 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 15 CUP PLATE RIDE - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 10 feet. Minimum Width – 25 feet. Minimum Length –25 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 16 KIDS PLAY -1 - minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 9 feet. Minimum Width – 4 feet. Minimum Length – 4 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 17 KIDS PLAY-2- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 10 feet. Minimum Width – 5 feet. Minimum Length – 5 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 18 KIDS PLAY -3- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height –9 feet. Minimum Width – 9 feet. Minimum Length –9 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 19 CONE SEATING- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 6 feet. Minimum Width – 5 feet. Minimum Length – 10 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 20 GAZEBO- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 10 feet. Minimum Width – 10 feet. Minimum Length – 10 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 21 SEATING-1- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 4 feet. Minimum Width – 6 feet. Minimum Length – 60 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 22 SEATING-2- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 5 feet. Minimum Width – 4 feet. Minimum Length – 15 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 23 SEATING-3- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 5 feet. Minimum Width – 5 feet. Minimum Length – 15 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 24 JUG CAFE- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 10 feet. Minimum Width – 10 feet. Minimum Length – 15 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 25 WATERFALL- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 8 feet. Minimum Width – 6 feet. Minimum Length – 15 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 26 FLOWERS- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 15 feet. Minimum Width – 10 feet. Minimum Length – 10 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 27 LAMP- minimum area as per below details, using the scrap/waste material available at the sites . Minimum Height – 15 feet. Minimum Width – 10 feet. Minimum Length – 10 feet.Foundation/Base Specs if requires–Brickwork all around the platform as a base for the platform on which installation shall be placed PCC below the concrete slab RCC M - 25 if required. with Vacuum Dewatering External Pavers / Stone Tiles on top of RCC Slab, if required. Designing, Fabrication,Installation of to be made from Scrap/waste material. The miniatures/sculpture/structures must be structurally strong and shall be embedded in cement concrete in the ratio of 1:3:6 (1cement : 3 coarse sand : 6 stone agg. 20mm nominal size) including excavation and removal of surplus earth. For finishing while installation of miniatures / sculptures Applying primer coats (two or more coats) of approved quality primer, painting with P.U. Coating automotive paint of approved quality (two or more coats) with giving proper finishing as per direction of work-in-charge 28 Supply, Installation, Testing & Commissioning of 11/0.433kV, 3-phase, 63 kVA Distribution Transformer with Bimetallic Terminal Connectors, Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate, Gapless Surge Arrestor 9 kV ,10 kA ,LA with polymer housing, Stn. Type, 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type, 11kV Horngap fuse set 3 phase 200A, 25 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type, 9 Mtr. Long Pole( ST-410 SP33),11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm, GI Channel/Angle/Flat of sizes including clamps, Galvanized Nuts and Bolts, 32/63 amps TPN Switch Disconnector Fuse Unit, Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole, Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover,11KV polymeric composite pin insulator 12KV,5KN, Lighting impuse 75KV Positive and 80KV Nragtive ,creepage distance 320mm,LT Distribution Box for63/100/200/250KVA DTR with MCCB for incomer & SFU for outgoingCircuits, Galvanised Stay Set with 50 x 8mm stay clamp,guy insulator(2nos) anchor plate (200 X 200 X 6mm), nut bolts, 2 Nos turn buckles,1.8m long ,16mm diameter solid GS stay rod & 7/3.15mm dia GI Stranded wire complete,Wedge connectors/PG Clamps,Danger Plates with Clamps, GI Barded Wire for Anti Climbing ,3-Ø,4 Wire Trivector Meter with CT ,Cement bottoming 1:2:4 mix as per REC Standards .5cum/pole, Painting of poles Red Oxide, Painting of polesAluminium Paint ,Sundry items like aluminium lugs,jumpers,binding tape,DAGAR GENSET 29 SITC11KV Tapping Point Mid spanDSR 2022 14.16.1 30 SITC of 1KM of 11KV Line on 9MTR ST Poles,50mm²ACSR Conductor with half span of 52Mtr:: 9 Mtr Long POle( PCC WL 300KG ,ST-410 SP33) ,11Mtr Long Pole ( PCC WL 360KG ,ST-410 SP56) , GI V cross with top Bracket including clamp ,GI Channel X arm including clamps and braces 50mm²ACSR Conductor PG Clamps for 50mm²ACSR Conductor, 11 KV Polymeric composite Pin Insulator 12kV , 5KN,Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm,11 KV Polymeric composite disc Insulator 12kV ,min failing load 45KN,Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm ,Galvanized Nuts and Bolts,Danger Plates with Clamps , Anti Climbing Device with Clamps, Earthing pipe of 40 mm or GI Rod 20mm 2.5Mtr long through GI Strip, Red Oxide,Aluminium Paint , Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole ,Stone Pad (300mm X 300mm x 75 mm)Aluminium Jointing Sleeves,Galvanised Stay Set with 50 x 8mm stay clamp,guy insulator(2nos) anchor plate (200 X 200 X 6mm), nut bolts, 2 Nos turn buckles,1.8m long ,16mm diameter solid GS stay rod & 7/3.15mm dia GI Stranded wire complete . 31 DG SET 125 KVAThree Phase with AMF Panel, Water cooled , diesel engine , 4 Cylinder, liquid cooled, Turbocharged After cooled,developing 156 HP at 1500 RPM. This is electric start, compression ignition, 4 stroke engine design torun continuously 1500 RPM. Diesel conforms to present CPCBIV+ norms. The diesel engine comprises of following: -• Radiator with Fan • Electric starter motor with soft starting system• G3 as per ISO 8528 Part V class governor • Battery charging alternator• Dry type Air cleaner with service indicator • CRDI System• Lube Oil & Fuel filter • DOC , SCR• First fill of lube oil & coolant • IoT Remote Monitoring System ALTERNATOR:, suitable for continuous operation rated at 1500 rpm 415.00V, 0.80PF, 50.00Hz, Ph. in SPDP enclosure, self-excited, self-regulated Brush less, floor mounted. The alternatorconforms to IS:4722,BS EN 60034-1 & will be suitable for tropical condition.with Installation at site 32 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 33 63mm Dia (OD- 63 MM andID 51 MM) DSR 2022 ( 1.32) 34 90mm dia (OD- 90 MM andID 76 MM) DSR 1.21.2 35 120 mm Dia ((OD- 120 MM andID 103 MM) DSR 2022 (5.2) 36 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. DSR 2022 (5.18) 37 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a )25 mm DSR 2022( 2.10.1) 38 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required .DSR 2022( 2.10.2) 39 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required .DSR 2022 40 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required . A)Single pole 2.15.2 41 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .b)Single pole and neutral2.15.3 42 Supplying and fixing Following rating ,four pole (three phase and neutal),415 volts, residual current circuit breaker (RCCB) having a sensitivity current 30 MA in the existing MCB DB complete with connections,testing and commissioning etc.as required. DSR 2022 2.2.14 43 40ADSR 2022 (1.17.3) 44 63 A DSR 2022 (1.17.12) 45 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required . b) 125 A,36KA,FPMCCB 46 Supplying, Instalaltion, Testing & Commissioning of1.1 grade, 3x1.5sqmm FRLS PVC insulated flexible copper conductor, Single core cable in the existing surface/recessed steel/ PVC Conduit as required. 47 Supplying, Instalaltion, Testing & Commissioning1.1 grade, 3x2.5sqmm FRLS PVC insulated flexible copper conductor, Single core cable in the existing surface/recessed steel/ PVC Conduit as required. 48 Supplying, Installation, Testing & Commissioning of following cable Al. conductor XLPE insulated PVC Tape inner sheathed for multi core cables , Armoured as per IS,PVC type ST to sheathed 650/1100V grade as per IS 7098 (part 1)1988 49 4Cx4 Sqmm 50 4Cx6 Sqmm 51 4Cx10 Sqmm 52 4Cx16 Sqmm 53 4Cx25 Sqmm 54 3.5C x 70 Sqmm 55 Supply, Installation, Testing & Commissioning of 12W LED Landscape outdoor LED Bollard made out of Aluminium casting complete 600-700mm long with PU paintand suitable post top LED light, PC diffuser opening for uniform distribution of light.Luminaire is provided with a base plate and fixing holes for directly mounting on the concrete pedestal. Height of Bollard between 600-700mm. Where Luminaire is wired with inbuilt driver with 4.5kV surge protection, Nominal Supply voltage will be 220-240V, power factor will be more than 0.95. And ingress protection will be IP65.CCT:3000K ± 250K. The branding name shall be embossed on the housing of the fixture. The minimum warranty shall be for 2 years. 56 SITC of 5 Mtr height flange mounted hot dip galvanized Octagonal pole made from HT steel plate,window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd,terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for Upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the Pole. Galvanization as per relevant IS.5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick including Foundation. Fabrication supplying and fixing Class B Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000 mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd. Foundation bolt size 16mmx600mmx4 nos. each inclusive 45 Watt LED light fixture. 57 Supply, Installation, Testing and Commissioning of 50 Watt LED floodlight luminaire 3000K colour temp. CRI>70, LED life 50000 burning hours 50° Temp. surge protection up to 3KV, IP65 and IK 06 with Die-cast aluminium housing, powder-coated finish, of following wattage.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 .Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 58 Supply, Installation, Testing and Commissioning of 30 Watt LED floodlight luminaire 3000K colour temp. CRI>70, LED life 50000 burning hours 50° Temp. surge protection up to 3KV, IP65 and IK 06 with Die-cast aluminium housing, powder-coated finish, of following wattage.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 .Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 59 Supply, Installation, Testing and Commissioning of 90 -100 Watt LED floodlight luminaire 3000K colour temp. CRI>70, LED life 50000 burning hours 50° Temp. surge protection up to 3KV, IP65 and IK 06 with Die-cast aluminium housing, powder-coated finish, of following wattage.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 .Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required . 60 Supply,Installation,Testing and Commissioning of 25-30 Watt Warm White LEDLinear Wall Washer luminaire CCT 3000K ± 250K for illuminate 3D wall painting with aluminium extruded housing. Length of the luminaire shall be 1000mm in size.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270VAC ,50Hz , powerfactor>0.9. Fixture shall be suitable to operate at ambient temperature range of-5°Cto+50°C and shall be IP65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required Engineer-In-Charge. The branding name shall be embossed on the housing of the fixture. The minimum warranty shall be for 2 years. 61 Supply,Installation,Testing and Commissioning of 40-45 Watt Warm White LEDLinear Wall Washer luminaire CCT 3000K ± 250K for illuminate 3D wall painting with aluminium extruded housing. Length of the luminaire shall be 1000mm in size.Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270VAC ,50Hz , powerfactor>0.9. Fixture shall be suitable to operate at ambient temperature range of-5°Cto+50°C and shall be IP65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required Engineer-In-Charge. The branding name shall be embossed on the housing of the fixture. The minimum warranty shall be for 2 years. 62 SITCJunction boxes outdoor type Supply made of Thermoplastic PolycaronateBoxes Mini. Size 93 x 93 x 62 mm in Black colour. The Junction Box Should be IP 67/69 ( IEC 60529 ) Thermoplastic PC weatherproof with multi level knockouts on four Side for cable Entry in different sizes . Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. The Box Should be UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4. The Joint Box should be Weatherproof : Rainwater proof, temperature resistant, Connecting Box as per IEC 60670-22 and IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C. The box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable Terminals . The Junction Box with nut bolts complete all as per manufacturer’s instructions.Make : Cat Part :- KF 0202 B of Hensel/Siemens/GE Power/Schneider/ L&T/ABB. Manufacturer should submit test certificate as per above Standard. 63 SITCJunction boxes outdoor type Supply made of Thermoplastic PolycaronateBoxes Mini. Size 205 x 255 x 112 mm in Black colour. The Junction Box Should be IP 67/69 ( IEC 60529 ) Thermoplastic PC weatherproof with multi level knockouts on four Side for cable Entry in different sizes . Lid fasteners shall not have screws but shall be with quarter turn locking knobs – which is well visible ( open – locked), and they will be sealable without any accessories. The Box Should be UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4. The Joint Box should be Weatherproof : Rainwater proof, temperature resistant, Connecting Box as per IEC 60670-22 and IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C. The box shall have elongated holes inside and suitable brackets outdoor fixing them for wall/pole mounting provision with suitable Terminals . The Junction Box with nut bolts complete all as per manufacturer’s instructions.Make : Cat Part :- KF 02525 B of Hensel/Siemens/GE Power/Schneider/ L&T/ABB. Manufacturer should submit test certificate as per above Standard. 64 Supply, installation, Testing and Commissioning of power distribution control Panel made out of 2 mm sheet steel, powder coated gray paint shade RAL 7032 specially designed bus bar to provide safety suitable for accommodating MCCBs, 1 No, 400 Amp 50 KA FP MCCBas incoming, On Load Changeover of 400 Ampand 2 Nos 125 Amp FPMCCB as outgoing complete with 50 Hz 415 Volt AC Supply, prewired digital meter Module including Voltmeter, Ammeter with selector switch, CTs control fuse and indicating lights for outdoor type IP-55 etc as reqd. (8 ways) . 65 Supply, installation, Testing and Commissioning of 12.5MTR shaft shall be in 2 section with hot dip Galvanised . There shall be circumferential Weld.It shall also include accessories for high mast including head frame,3point spension system with steel wire rope 6mm dia,double drum winch,cable,Galvanised Lantern carriage arrangement suitable for 6/12Luminaries .Supply of Foundation bolts manufactured from special steel along with nuts,washers,anchor plates&Temlates.Bottom Dia 360mm ,Top Dia 150mm ,Sheet Thk 3.3mm Automatic Control panel Fabricated with 16SWG CRCA sheet of size 600 X 600 X 300mm outdoortype with 25A Contractor ,63AMCCB,24 Hr Timer & Revese /Forward Switch. Flood light 150W Fixture made of pressure die cast Aluminium housing with front Toughened Glass with suitable lens for uniform having IP66 protection ,lumen 120/Wfor high Efficiency LED ,THD-10%, Potted driver with 4/6kva surge Protection. 66 Providing and fixing of flexible LED strip fixtures suiatable for rated voltage 220 volts, 50 Hz supply in White /Green/Red/Warm white color including all accessories like connectors, Endcap,Holding Cap and connector pins but excluding integrated LED adoptor etc as required. 67 Providing and fixing of Integrted LED Adaptor forflexibleLED strip fixtures suiatable for rated voltage 220 volts, 50 Hz supply etc as required. 68 SITC of Pillar box Size 900 mm x 450 mm x 250 mm suitable for mounting incomer of 250 A MCCB/Main Switch Pole and energy meter 3 phase complete with eleethoypic grade aluminium of bus bar 25mm x 10 mm mounted on galvanised M.S. body power quoted pilferage proof SMC door Welded with S.S. rain com size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below ground and covered with shade proof SMC sheet of 3 mm as required. 69 CCTVS/I/T/C of 2MP varifocal lens Bullet IP Camera with following specifications:-Image Sensor: 1/2.8 2MP CMOS or better**Minimum Illumination: 0.1 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate:25 fps or better **Lens: 2.8 to 12mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (1920x1080) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 20mOperating Temperature: -20 to 55 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL 70 S/I/T/C of 2MPPTZCamera with following specifications:-Image Sensor: 1/2.8 2MP CMOS or better**Minimum Illumination: 0.1 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate:25 fps or better **Lens: 30 X ZOOMVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (1920x1080) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 20mOperating Temperature: -20 to 55 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL 71 S/I/T/C of 32 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or better**Network Throughput :160Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 2 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg CentSafety standard: UL 72 SITC of 6 TB surveillance HDD 73 SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch 74 Supply Installation testing Commissioning of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U 75 S/I/T/C ofLED Monitor full HD complying with the following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 400 NITS min. Video I/P port a) Min. 02 Nos HDMI 1920x1080. b) Min 01 No VGAContrast : 1200 : 1 or betterPower supply : 230v + / - 10%, 50 HzInstallation at sitewith connections andalong with all accessories of 42 INCHESetc.complete as required with min. 3 year onsite warranty. 76 P/f of Hot press sheed moulded compound (SMC) Fire retardant (Temp. Resistance up to 200 C ) IP-55 weather proof pole box of inner dimension 300mm X 200mm X105 mm(NS) complete with suitable arrangment for fixing of 4 nos of 6 to32 amp single pole MCB & 63 Amp double pole isolator (MCB/Isolator excluded)with neutral link duly shorting on DIN channel with 2 nos. of MS clamps with SS back plate of suitalbe size with Danger monogramproperty printed on the cover etc as reqd. 77 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD- 63 MM andID 51 MM) 78 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 79 Supply of following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable conforming to IS .694/2010 etc. as reqd. 3x 2.5 sqmm 80 Supply Installation testing and Commissioning ofPigtails 1 meter with Splicing and testing. 81 Supply Installation testing and Commissioning of opticalmedia converter gigabit SC to SC type up to 10 km. 82 Supply Installation testing and Commissioning ofLIU boxes complete with all accessories etc. as required of 12 ports 83 Supplying and laying of Optical Fiber Single Mode Cable (6-Fiber) on surface or in existing conduit etc complete i/cconnections etccomplete as required 84 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 85 PA System SITC all weather proof loudspeaker forspeakers for otdoorground , having soundLF, HF - 1 exit Max SPL not less than 128db /1m (peak), with continuous RMS power of 45 - 55 Watt RMS with programme power of 90 – 110 WattRMS & peak power of 180 - 220 Watt RMS with minimum sentivity of 97db, Nominal Impedance : 8ohms, nominal dispersion : 90 x 60, in birch plywoodpaint finish with wall mount bracket , suitable size MSframe box cover for protection etc. complete asrequired. 86 Supply installation testing & commissioning of Professional total 16 channel audio mixer with 16 mic inputs; 2 line inputs 2 stereo inputs; with inbuilt effects and equalizer, graphic EQ etc. complete as reqd. 87 Supply installation testing & commissioning of DualChannel Power Class H/ D amplifier for Subwoofer &Main Speakers & outdoor speakers 2000 watt ,Damping factor > 450, as required. 88 Supply installation testing & commissioning ofCordless Handheld Microphone with UHF frequency(10 Selectable Frequencies) with 10 MV RF output, etc.complete as required. 89 Supply, laying & Fixing of Speaker Lines: 2-Core, 2.5sq mm High definition Speaker Cable, PVC insulated inPVC jacket laid in existing conduits as reqd. 90 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a )25 mm 91 Supplying, installation, testing & commissioning of mixer amplifier mic input, USB input and Bluetooth, 50 Watt, at 240 volt AC supply complete etc as required. 92 Supplying, installation, testing & commissioning of mixer amplifier mic input, USB input and Bluetooth, 75 Watt, at 240 volt AC supply complete etc as required. 93 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. 94 P/f of Hot press sheed moulded compound (SMC) Fire retardant (Temp. Resistance up to 200 C ) IP-65 weatherproof pole box of inner dimension 500mm X 400mm X200 mm(NS) complete with suitable arrangement to accommodate for fixing mixer amplifier complete as required 95 Heavy Duty tripod Turnstile, Specification ;- Passage width of 520mm,throughput rate;35p/m,power supply ;100-240v,opertional voltage-24v,max power cosumption ;30w,frequency;50-60hz,prectection level;IP44,working tempertaure;25c to 70c,,electromagnetic drive-DC,dimension excluding bars-480x280x980,,semi auto mode,pure mechanical mode,bidirectional function,adustable timeout delay.Material-Housing(ss304),Barrier arms(stainless steel),Lid (Steel/artifical stone) 96 BOOM BARRIER - BGL-100 MaximumlengthofBoom:5mBoomRestStand:YesArmmaterial:Aluminium(withRed&GreenLEDindication)TimeforUp/down:6sInputcontrolsignal:DrycontactIngressprotectionDegree:IP54InputInterfacefor:1.Photocell2.Airswitch3.LoopdetectorLEDIndicator:Red/GreenOptionalInterface:Accesscontrolpanel,Standaloneaccesscontrol,ControlbuttonRemotecontrol:Yes,upto25metersMode:Automatic/ManualIncorporatedcontrolpanelwith3pushbuttons(STOP/UP/Down)tocontrolthemotorBumpingbounceback:Optional 97 Provision of Ticketing Software System Application Admin Panel for remote access & real time data viewing along with MIS reports,Kiosk App for Ticket printing at Counter (Android),QR Scanner app for Entry Gate (Android),QR Scanner app for Exit gate (Android),Backend Software For online mode and online access,Backend Software for Offline mode and offline access Training of software to MCD employees and continued service support including upgradation along with 5 years service support with no extra payment. Make Custom built as per department requirement HSN/SAC: 998314 98 Providing and fixing of Ticketing Hardware System (General) Smart Network Router (Minimum AC1750,802.1 ac/up to 300+1450Mbps/gigabit) - 1 No Make Netgear/ TP-Link/ Asus HSN/SAC: 998319 99 Providing and fixing of Ticketing Hardware System (Pre Counter) -At least 10-inch android tablet (6000mAH battery,2GB RAM,32GB ROM,charger) With screen Protector - 1 Nos -Thermal Printer (ethernet/LAN/auto cutter) 1 Nos., -Tablet Stands - 1 Nos. -Black Metal lockable Cash Drawer/register/locker with Key and lock and 5 compartments for paper currency with Stainless Steel Clips and 8 compartments for coins [Size – 16.53inch (length) * 15.95inch (breadth) * 4.33Inch (height)] – connect with thermal printer/tablet for added security and easier cash management. - 1 Nos -MultiPlugs/Extension Cords - 1 Nos Make A: For Tablet (Samsung/ Lenovo/ Xiaomi) B:For Thermal Printer (Epson/ Brother/TVS) C : Tablet Stand (Generic) D:Drawers (Generic) E:Multiplugs/Extension Cord (GM/ Havells/ Anchor/Cona) HSN/SAC: 998319 100 Providing and fixing of Ticketing Hardware System (Entry/Exit Gate) - At least 6 inch Android Phone (5000mAH battery,2GB RAM,32GB ROM,13MP/5MP,charger) with screen Protector and Cover - 1 Nos., - Manual/ Wireless Barcode/QR code Reader (Bluetooth 1D/2D scanning,ShockProof,charger) - 1 Nos. -Power Banks for Battery Backup for Android Phones - 1 Nos Make A: For Phone (Samsung/ Lenovo/ Xiaomi/Nokia/Redmi/OnePlus) B:For Reader (Epson/ Dcode/ Pegasus ) C : Power Banks (Ambrane/ Xiaomi/ Duracell/ Portronics) HSN/SAC: 998319 101 On Premise Physical Ticketing Server (Processor - [1*10C/20T 9.6GT/s, 13.75M Cache Processor (Expandable upto 2 processors)], RAM - [1*16GB RDIMM, 3200 MT/s dual rank (total 16 ram slots)], server management tool, Hard Disk - [2.4TB ,HDD 10K RPM ,Hot Plug 2*1.2TB for data failover (expandable upto 8 drives) RAID 1 + Controller +2GBNV Cache,DVDRW+Dual Power Supply (2*495W,instant failover capability),LAN (2*1Gbe LOM) ,UEFI/GPT),5 year onsite warranty Make Dell /HP/Lenovo HSN/SAC: 998319 102 Horticulture Ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bagDSR Horticulture 7.27 103 Supply of Ficus panda of height 45-60 cm. with 6-7 branches and healthy foliage in polybag of size 25 cm as per diraction of officer-in-chargeDSR Horticulture 8.26 104 Supply of Rhapis Palm having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed,full of fresh andhealthy leaves in 25 cm size of Earthen pot / Plastic pot. as per direction of the officer-in-chargeDSR Horticulture 3.75 105 Supply of Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in HDPE bag as per direction of the officer-in-chargeDSR Horticulture 3.21 106 Supply of Wadelia trilobata,full of leaves in 15 cm size in plastic Bag as per direction of the officer-in-chargeDSR Horticulture 10255 107 Supply of Syngonium (Butterfly) variegated with 2-3 suckers healthy foliage in Earthen Pot/ Plastic Pot of size 25 cmas per direction of the officer-in-chargeDSR Horticulture 3.91 108 Supply of Iresine herbstii, of height 25-30 cm., full of branches well developed in 15 cm size of Earthen Pot / Plastic Pot. As per direction of officer-in-chargeDSR Horticulture 6.10241 109 Supply of Tabernaemontana coronaria (Chandni single) variegated of height 105-120 cm., multibranched, bushy in big size HDPE bag as per direction of the officer-in-chargeDSR Horticulture 8.63 110 Supply of Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in chargeDSR Horticulture 2.34 111 Providing and Fixing Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge.DSR Horticulture 5.32 112 Providing and Displaying Topiary of Ficus Panda well developed with fresh & healthy foliage with 3 to 4 Ball and 60 to 75 cm spread each Ball, 135 to150 cm ht., in 35 cm HDPE bags /Cement Pot as per direction of theofficer-in-charge.DSR Horticulture 5.4 113 Providing and Displaying Cyprus Golden Conical Shape 150 to 165 cm ht., with fresh and healthy Golden colour foliage in 35cm Cement Pot as per direction of the officer-in-charge. DSR Horticulture 5.18 114 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. DSR Horticulture 8.24 115 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. DSR Horticulture 7.71 116 Providing and stacking of Pterospermum acerifolium (Kanak Champa) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR Horticulture 7.78 117 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of theofficer-in-charge. DSR Horticulture 5.12 118 Providing and Displaying Cycus revoluta in 35 cm challi, specimen , having 30 to 40 with fresh and healthy, leaves having 25cm to 30cm circumfrance of base stem well developed as per direction of the officer-in-charge. DSR Horticulture 5.14 119 Providing and stacking of Largerstroemia indica diffrent color of height 90-105 cm. multibranched in poly bags of size 25 cm as per direction of the officer-in-charge.DSR Horticulture 8.43 120 Bauhinia blakeana (Kachnar) diffrent color height 120-150 cm. in big poly bag size 25 cmDSR Horticulture 7.7 121 Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.DSR Horticulture 5.11 122 Providing and Fixing fishtail palm ht. 240cm bottom girth 40-50 cm well developed in big HDPE bag 123 Providing and Fixing foxtail palm ht. 240cm bottom girth 40-50 cm well developed in big HDPE bagDSR Horticulture 5.3 124 Providing and Fixing croton petra ht. 20-45cmin big HDPE bagDSR Horticulture 3.66 125 Providing and Fixing dracaena song of india ht. 20-45cmin big HDPE bagDSR Horticulture 3.44 126 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 80 mm nominal inner dia Pipes DSR 18.9.8 Rs 2166.4 127 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia Pipes DSR 18.9.4 Rs 438.6 128 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil DSR 2.6.1 129 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 DSR 16.78.1 130 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). DSR 16.69 131 Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. DSR 16.68 132 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand)cluding 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : 19.27.1 With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 DSR 19.27.1 133 Providing and laying in position cement concrete of specified grade excluding the cost of centering andhuttering - All work up to plinth level1:2:4 (1 cement : 5 oarse sand (zone-III): 10 graded stone aggregate 25 mm nominal size) DSR 4.1.10 134 Steel work welded in built up sections/ framed work 0.789 X 110 X 100 mm, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gatesand similar worksDSR 10.25.2 135 PROVIDING AND FIXING G.I CHAIN LINK FABRIC FENCING OF REQUIRED WIDTH IN MESH SIZE 50x50mm including strengthining with 2mmdia wire or nuts,bolts and washer as required DSR 16.70 136 Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).DSR 6.27 137 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand) DSR 13.11 138 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 139 Design, manufacture and supply of5 KWSolar Power Tree Grid Connected System with net metering facility.a)Solar Photovoltaic Module of capacity 265Wp or above, manufactured in India,conforming to IS14286/IEC61215,IS/IEC61730-Part-1,IS/IEC61730-Part-2.SolarPhotovoltaic Module conversion efficiency shall not be less than16.5%.PVmodules used in solar powerplants/systems must be warranted for their output peak watt capacity,which should not be less than90%at the end of 10years and 80%at the end of 25 years. b)Power Conditioning Unit(PCU)of350-800VDC Input voltage range and 400VAC,three phase,4wire,50Hz+/-2.5Hz,output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50degreeC.ThePCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP65protection and termination arrangement for incoming and outgoing cable alongwith glands,lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f)Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit alongwith supplying & fixing of necessary channel/conduit lugs and other accessories etc.as required. 140 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of Soil DSR 2.6.1 141 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) DSR 4.1.8 142 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.DSR 2.27 143 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentrationDSR 2.35.3 144 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (Plinth Band)DSR 5.1.2 145 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Lintel Band)DSR 5.3 146 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Beam)DSR 5.3 147 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab)DSR 5.3 148 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.DSR 5.22.6 149 Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)DSR 6.1.2 150 Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in superstructure above plinth level up to floor V level in all shapes and sizes in :(1 cement : 6 coarse sand) (230mm wall)DSR 6.4.2 151 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (1 cement : 4 coarse sand)DSR 6.13.2 152 Providing 40x5 mm flat iron hold fast 400 mm long including fixing toframe with 10 mm diameter bolts, nuts and woodenplugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).DSR 9.53 153 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge.DSR 9.123 154 Providing and fixing factory made PVC door shutter made of solid foam PVC profiles of thikness 5 mm and 15 mm at edges integrally extruded for vertical style and horizontal (top/ bottom/ lock) rails of minimum cross section of 70mmx 28mm, of shape and design as per manufacturers specifications having homogenous fine cellular structure and smooth integral outer skin, inserted with G.I. C section/ rectangular tube profile of minimum 0.30 mm thickness with 120 gsm coating as stiffeners as per manufacturers specifications Mitred cut joints for styles and rails provided with telescopic polymeric L corners are jointed together using solvent adhesive and strenghtened with fully threaded stainless steel screws (of required size) through reinforced stiffener with paneling of specified solid foam PVC board/ high pressure laminate of required thickness and of approved design and shade (matching the styles and rails), secured within styles and rails with specially designed solid foam PVC moulded beadings of required size using PVC solvent adhesive/ cement. The finished door shutter including SS hardware, 1 no. ss sliding bolt 200 x 10mm, 1 no. SS tower bolt 200 x 10 mm and 2 nos. SS handles 125mm, shall be fixed to frame with 3 nos, stainless steel hinges of minimum size 100x58x1.9 mm and stainless steel screws of required size complete as per direction of the Engineer-in-Charge. (Cost of above hardware is inclusive in rates. 5 mm thick solid foam PVC panel of required size with moulded/ extruded beading of appropriate design shape and size as per manufacturers specifications (to secure the panel insert tight in place within the style and rails of shutter) matching the colour and shade of shutter frame. Non decorative type.DSR 9.124 155 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)DSR 10.10.1 156 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. In Outer Side DoorDSR 9.48.1 157 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with (4.0mm thick float glass)DSR 10.30.1 158 12mm thick plaster in inner walls with proportion of 1:6 cement & approved coarse sand 159 12mm thick plaster in Exterior walls with proportion of 1:6 cement & approved coarse sand 160 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. 161 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 162 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 163 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 164 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement 165 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 166 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 167 Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. 168 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer 169 Finishing walls with Acrylic Smooth exterior paint of required shade : 170 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 171 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufactureDSR 13.62.1 172 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).DSR 10.28 173 Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 250/ 300/ 400mm and length of 595 mm of approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of > 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework(Alloy 6063 T5/T6) consisting of vertical T (for intermediates)/ L(for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of 600mm c/c matching to the tile vertical grid, and horizontal aluminium C-clamps of size 56x25x2mm thickness of length 150mm at junction of tiles and of length 75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/ c matching to the tile horizontal grid with two numbers of selfdrilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.The vertical T/L/ Tubular sections shall be fixed to the wall using HDG (hot-dip-galvanized) steel L-brackets (galvanizing thickness of minimum 80 microns)of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mm at outer corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two numbers self-drilling/ self-tapping SS screws of size 5.5x25mm with EPDM washers. EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be additionally secured to the horizontal ‘C’ clamps using special SS clips of required size which shall be inserted and pressed into position on the ‘C’ clamps holding the tiles and the cuttiles shall be glued at points to the horizontal ‘C’ clamps by using MS Polymer sealant adhesive. The vertical joint open groove between two adjacent tiles shall be 5mm. The tiles and system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in- Charge. Note : Scaffolding wherever required to be paid separately. With 16mm thickness (+/- 10%) terracotta tiles of other than grey colors DSR 26.92.2 174 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.DSR 4.17 175 Centering and shuttering including strutting, propping etc. and removal of form for Plinth Beam DSR 5.9.5 176 Centering and shuttering including strutting, propping etc. and removal of form for Lintel BeamDSR 5.9.5 177 Centering and shuttering including strutting, propping etc. and removal of form for Beam DSR 5.9.5 178 Centering and shuttering including strutting, propping etc. and removal of form for Slab DSR 5.9.20 179 Providing and fixing water closet squatting pan (Indlan type W.C. pan) with 100mm sand cast Iron P or Strap, 10 litre low level white P. V.C. flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 180 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required ::Parryware /Hindware /Seabird /Orient (Coral)or equivalent W.C. pan with ISI marked white solid plastic seat and lid 181 Providing and fixing white vetreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Range of two urinal basins with 5 litre white P.V.C. automaticflushing cistern 182 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade 183 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 184 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 185 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 186 Semi rigid Pipe 187 32 mm dia 188 CP Brass fittings 189 Providing and fixing unplasticised PVC connection pipe with brass unions 190 45 cm length 191 15 mm nominal bore 192 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 193 a) 15 mm nominal bore 194 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 195 a) 15 mm nominal bore 196 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 197 15mm nominal bore 198 PVC PIPES & FITTINGS AND RAIN WATER PIPES 199 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 200 110mm 201 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 202 110 mm 203 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 204 Bend 87.5 degree 205 110 mm 206 Shoe (Plain) 207 110 mm 208 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 209 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 210 INTERNAL & EXTERNAL WATER SUPPLY WORKS 211 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 212 15mm dia nominal outer dia pipes 213 20mm dia nominal outer dia pipes 214 25mm dia nominal outer dia pipes 215 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall 216 25mm dia nominal bore 217 32mm dia nominal bore 218 Providing and fixing gun metal gate valve with wheel of approved quality. 219 25mm dia nominal bore 220 32mm dia nominal bore 221 Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Capcity in Per Liters 222 SEWERAGE SYSTEM 223 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. DSR 2.1 224 All kinds of soil 2.10.1 225 Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. 2.10.1.2 226 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. DSR 19.1 227 200 mm diameter 19.1.3 228 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design DSR 19.2 229 200 mm diameter 19.2.3 230 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 231 150 x 100 mm size P type 232 With Sewer bricks conforming to IS : 4885 19.4.2.1 233 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :18.33 234 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 18.33.1 235 SANITARY INSTALLATIONS & C.P FITTINGS 236 Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes. 237 a) 110mm dia P.V.C. pipe 238 b) 90mm dia P.V.C. pipe 239 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 240 P-Trap type Floor Trap 110 x 90mm 241 Providing and fixingterminal guard. 242 a) 110mm 243 b) 90mm 244 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 245 110mm bend 246 90 mm bend 247 Coupler 248 110mm 249 90mm 250 Single tee with door 251 90x90x90 mm 252 110x110x110 mm 253 SUBHEAD I- WIRINGPOINTS 254 UPPWD-2018 255 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.. Group B Sch no. 1.10.2 256 Light 257 Exhust 258 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 259 2x1.5sq. MmSchno. 1.17.2 260 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 261 25mm Sch no 1.21.2 262 Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 263 6 Module (200mmX75mm) 1.27.4 Sch no 1.27.4 264 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Schno 1.31 265 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep Sch no. 1.50.1 266 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Sch no. 5.6 267 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with Gl thimble etc. as required.Sch no. 5.7 268 Providing and fixing 256 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required.Sch no. 5.11 269 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Sch no. 2.3 270 6 way , Double door Sch No. 2.3.1 271 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 272 Single poleSch No. 2.10.1 273 Double poleSch No. 2.10.3 274 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 25 sg. mm (25mm) DSR E/M 9.1.9 275 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. Cat AA M.R. 276 Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Cat AA M.R. 277 Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as requiredM.R. 278 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All Kind of SoilDSR 2.6.1 279 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (Base Concrete) DSR 4.1.8 280 Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1 281 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (Slab) DSR 5.3 282 Centering and shuttering including strutting, propping etc. and removal of form for Slab DSR 5.9.20 283 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.DSR 5.22.6 284 Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1 285 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20mm thick DSR 13.9.2 286 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate DSR 11.3.1 287 Providing M.S. foot rests including fixing in tank with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar DSR 19.15.1 288 500 mm diameter C.I. cover (medium duty) 289 the cover to be not less than 58 kg (DSR 19.18.2) 290 C.I. Plain bend (DSR 17.39.1.2) 291 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.32.1)

Key Value

Document Fees
INR 3540 /-
EMD
INR 1193500.0 /-
Tender Value
INR 5.96 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail