| 1 | PART-A :-ROAD WORKS |
| 2 | Clearing and grubbing road land including uprooting rank vegetation, grass, bush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, disposal of unserviceable material and stacking of serviceable material upto 1000 m from road boundry as per MoRTH Specification : 201. By Mechanical Means. In area of light jungle |
| 3 | Earth work in excavation including stacking/ disposal of surplus earth with all lifts and lead upto 1000 meters exclusive of compensation of earth (MoRTH specification Clause 301 to 305). In hard soil. mechanically using bull dozer, F.E. loader and carriage upto 1 km by tipper/dumper. |
| 4 | Extra for watering the earth to bring the earth upto required O.M.C excluding rolling |
| 5 | Extra for rolling to specification with power roller 8-10 tonne when earth is at suitable moisture content with desired density excluding watering. Field density not less than 95% of maximum dry density (Ordinary Proctor test) |
| 6 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5. _do__ with lead500 mtr to 1000 mtr |
| 7 | Providing, laying, spreading and compacting specified graded Crushed aggregates as granular sub base course as per Table 400-1,400-2 or any other coarse material as per design mix, as per CBR, including premixing the material at OMC in mechanical mixer(Pug mill), carriage of mixed material spreading in uniform layers with motor grader, F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labour, machinery, lighting, guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401] by mechanical means with all lead. |
| 8 | Providing and laying granular sub-base material having P.I.not more than 6, including compacted thickness and consolidation by 8-10 tonne power roller at OMC to achieve desired density to required camber and grade including cost of water and hire charges of machinery, including T&P and all lead of material from quarry (compacted thickness to be measured). Grading as per MoRTH specification : Table 400-1,400-2 with CBR value not less than 25. To achieve 100% Proctor density |
| 9 | Providing, laying, spreadingand compactingstone aggregate of specific size as per table400-6 &400-7 to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of Stone screeningto fill-up the interstices of coarse aggregates, watering (with water browser) and rolling, making necessary earthenbund toprotect edegs,lighting, guarding,barricading and maintenance of diversion etc. [MoRTH specification:Clause 404] (bymanualmeans) with all leads (compacted thickness as specified to be measured). Grading no.2 (63-45mm) crusher broken |
| 10 | Providing, laying, spreadingand compactingstone aggregate of specific size as per table400-6 &400-7 to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of Stone screeningto fill-up the interstices of coarse aggregates, watering (with water browser) and rolling, making necessary earthenbund toprotect edegs,lighting, guarding,barricading and maintenance of diversion etc. [MoRTH specification:Clause 404] (bymanualmeans) with all leads (compacted thickness as specified to be measured). Grading no.3 (53-22.4 mm) crusher broken |
| 11 | Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 1000 metres, scaking serviceable and unserviceable materials separately as per MoRTH specification claue : 202. By Mechanical Means, Bituminous courses |
| 12 | Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 1000 metres, scaking serviceable and unserviceable materials separately as per MoRTH specification claue : 202. By Mechanical Means, Bituminous courses |
| 13 | Providing and applying primer coat over prepared surface or granular base with bitumen emulsion as per IS: 8887 & manufacturer’s specifications @ 6 kg /10 sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates and temperatures including cleaning of road surface as per MoRTH specification CIause- 502,112. Add extra to above item per 1 Kg Extra in Emulsion per 10 Sqm 8.50 Kg/10 Sqm |
| 14 | Providing and applying tack coat with bitumen emulsion on the prepared surface including cleaning as per IS : 8887 & manufacturer’s specifications @ 2 kg /10sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates and temperatures as per MoRTH specification CI.503,112. Add extra to above item per 2.75 Kg extra in emulsion per 10 sqm |
| 15 | Providing and laying bituminous macadam on prepared surface with specified graded crushed aggregate as per table 500 - 4, for base/binder course including loading of aggregates with F.E. loader and heating and mixing of stone aggregate and bitumen (including cost of antistripping compound wherever required) in hot mix plant, transporting the mixed material in tipper to paver and laying mixed material with sensor paver finisher to the requiredlevel and grade, rolling by power roller & vibratory compactor to achievethe desired density (as per job mix formula approved by the department )excluding cost of primer /tack coat [MoRTH Specification : Clause 504,112] with 3.30% bitumen with all lead. For grading-2 (layer thickness 50-75mm). with bitumen grade VG-30 |
| 16 | Providing andlayingopengraded premix carpet 20 mm thick (compacted) on prepared surface in a single course as wearing course, aggregates as per Table 500-23, heating bituminous binder @ 14.6 Kg/10 Sqm. and aggregates in Hot Mix Plant (including cost of antistripping compound, wherever required),transporting the mixed material with tipper and laying with paver finisher to the required level and grade, rolling with power roller 8 - 10 tonne but excluding cost of tack and seal coat with lead for mix of material 1 km. (MoRTH Specification : Clause 511,112) with all lead. In Hot Mix Plant 40-60 TPH, including loading of aggregates with F.E loader. with bitumen grade VG-30 |
| 17 | Providing and applying premixed seal coat type \"B\" comprising of thin application of fine aggregate (0.06 Cum. per 10 Sqm) premix with 6.8 Kg. per 10 sqm bitumen binder (including cost of antistripping compound, wherever required)inmini hot mix plant 6-10 TPH and laying and rolling with power roller 8-10 tonne including all lead of mix material [MORTH Specification : Clause 513] with all lead. (b) with bitumen grade VG 30 |
| 18 | Part - \"B\" CC Pavement |
| 19 | Construction of dry lean cement concrete sub- base over a prepared sub - grade with coarse and fine aggregate conforming to IS : 383, the size ofcoarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15 : 1, aggregate gradation after blending to be as per Table 600 -1, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at7 days, mixed in a batching plant as per mix design, transported to site, laid with a hydrostatic paver with electronic sensor, compacting with 8 -10 tonne vibratory roller, finishing and curing complete as per MoRTHspecification clause 601. |
| 20 | Construction ofun-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 602.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compoundand water finishing to lines and grade as per drawingand MoRTH Specification Clause 602 including vaccum dewatering process with all required equipments |
| 21 | PART-C :-RCC Box Culvert (6x7.00x7.00) |
| 22 | Earth work in excavation for foundation of structurecompletewith all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layers, ramming, watering and disposal of surplus earth with all lifts and lead upto 1000 meters exclusive of compensation of earth as per MoRTH specification Clause 301 to 305 |
| 23 | Providing and laying Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification as per MoRTH Specification : Section 1500, 1700 & 2100 including form work at any level. P.C.C. grade M15 |
| 24 | Providing and laying Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification as per MoRTH Specification : Section 1500, 1700 & 2100 including form work at any level. R.C.C. grade M20 |
| 25 | Providing and laying Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification as per MoRTH Specification : Section 1500, 1700 & 2100 including form work at any level. R.C.C. grade M30 |
| 26 | Providing and laying Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification as per MoRTH Specification : Section 1500, 1700 & 2100 including form work at any level. R.C.C. grade M30 upto 5 metre height |
| 27 | Structural Cement concrete upto a height of 5m for reinforced concrete in superstructure complete including steel formwork, scaffolding etc. as per drawing and technical specification as per MoRTH Specification 1500 & 1700. M 30 grade solid slab superstructure |
| 28 | Filter media behind abutment, wing wall and return wall, complete as per drawing and technical specification as per MoRTH Specification : Clause:2504 |
| 29 | Providing and laying Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification as per MoRTH Specification : Section 1500, 1700 & 2100 including form work at any level. R.C.C. grade M25 |
| 30 | Providing and fabricating steel reinforcement at any level including cutting, binding, placing in position and binding complete in foundation as per drawing and technical specification as per MoRTH Specification : Section: 1600 |
| 31 | Steel reinforecemnt in substructure complete as per MoRTH Specification : Section 1600. Mild Steel reinforcement |
| 32 | Providing A.C pipe Weep holes 150mm dia in Masonry/Plain Concrete/.Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specfication as per MoRTH Specification Clause 2205 |
| 33 | Providing and laying reinfored Cement Concrete grade M30 design mix railing complete as per drawingand technical specification as per MoRTH Specification :1500, 1600 & 1700 |
| 34 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302. Stone/Boulder |
| 35 | PART-D :-HP Culvert 2x1000mm Dia |
| 36 | Earthwork in excavation in foundation trenches etc. not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil 3m. Clear from the edge of excavation and subsequent filling around hume pipes/masonry in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 1000 metres.[MoRTH Specification : Clause 301,304]. Ordinary Soil |
| 37 | Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level as per MoRTH Specification : Clause 1000 & 1700. P.C.C. 1:3:6 mix with crushed stone aggregate 20 mm nominal size. |
| 38 | Providing and laying stone masonry work in cement mortar with mechanical mixer for foundation (any level) complete including all scaffolding etc. but excluding pointing and plastering as per drawing and technical specification as per MoRTH Specification : Section 1000,1400. Random rubble masonry, in cement mortar 1:4 |
| 39 | Providing, laying & fixing in position RCC spun or hume pipes ISI marked with proper jointing in required slope packed in the gasket of hume or spun yarn and neatly finished with rich grout of cement moratar 1:3 or having flexible rubber ring joint made with prefectly air and water tight including testing of joints as per MoRTH Specfication : Clause : 1000 & 2900. NP - 3 (Double Row), 1000mm dia |
| 40 | Providing Cement plaster 12mm thick in cement mortar 1:3 at all levels as per MoRTH Specfication: Clause:1000 & 1300 |
| 41 | Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRTH specification Clauses 1313, 1411 and 2206.6. 75 mm thick |
| 42 | PART-E :-HP Culvert 2x600mm Dia |
| 43 | Earthwork in excavation in foundation trenches etc. not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil 3m. Clear from the edge of excavation and subsequent filling around hume pipes/masonry in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 1000 metres.[MoRTH Specification : Clause 301,304]. Ordinary Soil |
| 44 | Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level as per MoRTH Specification : Clause 1000 & 1700. P.C.C. 1:3:6 mix with crushed stone aggregate 20 mm nominal size. |
| 45 | Providing and laying stone masonry work in cement mortar with mechanical mixer for foundation (any level) complete including all scaffolding etc. but excluding pointing and plastering as per drawing and technical specification as per MoRTH Specification : Section 1000,1400. Random rubble masonry, in cement mortar 1:4 |
| 46 | Providing, laying & fixing in position RCC spun or hume pipes ISI marked with proper jointing in required slope packed in the gasket of hume or spun yarn and neatly finished with rich grout of cement moratar 1:3 or having flexible rubber ring joint made with prefectly air and water tight including testing of joints as per MoRTH Specfication : Clause : 1000 & 2900. NP - 3 (Double Row), 600mm dia |
| 47 | Providing Cement plaster 12mm thick in cement mortar 1:3 at all levels as per MoRTH Specfication: Clause:1000 & 1300 |
| 48 | Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRTH specification Clauses 1313, 1411 and 2206.6. 75 mm thick |
| 49 | Part - \"F\" Drain Work |
| 50 | Earthwork in excavation in foundation trenches etc. not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil 3m. Clear from the edge of excavation and subsequent filling around hume pipes/masonry in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 1000 metres.[MoRTH Specification : Clause 301,304]. Ordinary Soil |
| 51 | Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level as per MoRTH Specification : Clause 1000 & 1700. P.C.C. 1:3:6 mix with crushed stone aggregate 20 mm nominal size. |
| 52 | Providing and laying Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification as per MoRTH Specification : Section 1500, 1700 & 2100 including form work at any level. R.C.C. grade M25 |
| 53 | Providing and fabricating steel reinforcement at any level including cutting, binding, placing in position and binding complete in foundation as per drawing and technical specification as per MoRTH Specification : Section: 1600. TMT Steel reinforcement |
| 54 | Providing and fixing of reinforced ferro-cement drain cover designed for class \"A\" & \"AA\" loading duly marked on cover with adequate steel reinforce- ment having thickness 75mm to 150 mm, anti-corrosive bitumen painted M.S. plate, rim and on M.S. lifting hooks, admixture like plastisizer bond-improving compound, shrinkage resistant compound, abrasion resistant complete as per approved design etc. --do--class \"AA\" loading. 600 x 800 mm (125 mm thick) |
| 55 | PART-G :-Protection Wall |
| 56 | Earthwork in excavation in foundation trenches etc. not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil 3m. Clear from the edge of excavation and subsequent filling around hume pipes/masonry in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 1000 metres.[MoRTH Specification : Clause 301,304]. Ordinary Soil |
| 57 | Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level as per MoRTH Specification : Clause 1000 & 1700. P.C.C. 1:3:6 mix with crushed stone aggregate 20 mm nominal size. |
| 58 | Providing and laying stone masonry work in cement mortar with mechanical mixer for foundation (any level) complete including all scaffolding etc. but excluding pointing and plastering as per drawing and technical specification as per MoRTH Specification : Section 1000,1400. Random rubble masonry, in cement mortar 1:4 |
| 59 | Raised and cut pointing on stone work in CM 1:2 (1 cement : 2 sand) |
| 60 | Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRTH specification Clauses 1313, 1411 and 2206.6. 75 mm thick |
| 61 | PART-H :-Syphon |
| 62 | Earthwork in excavation in foundation trenches etc. not exceeding 2 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil 3m. Clear from the edge of excavation and subsequent filling around hume pipes/masonry in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 1000 metres.[MoRTH Specification : Clause 301,304]. Ordinary Soil |
| 63 | Providing and laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5 metres below ground level and 1.50 metres above Ground/Bed level as per MoRTH Specification : Clause 1000 & 1700. P.C.C. 1:3:6 mix with crushed stone aggregate 20 mm nominal size. |
| 64 | Providing and laying stone masonry work in cement mortar with mechanical mixer for foundation (any level) complete including all scaffolding etc. but excluding pointing and plastering as per drawing and technical specification as per MoRTH Specification : Section 1000,1400. Random rubble masonry, in cement mortar 1:4 |
| 65 | Providing, laying & fixing in position RCC spun or hume pipes ISI marked with proper jointing in required slope packed in the gasket of hume or spun yarn and neatly finished with rich grout of cement moratar 1:3 or having flexible rubber ring joint made with prefectly air and water tight including testing of joints as per MoRTH Specfication : Clause : 1000 & 2900. NP - 3 (Single Row), 300mm dia |
| 66 | Providing Cement plaster 12mm thick in cement mortar 1:3 at all levels as per MoRTH Specfication: Clause:1000 & 1300 |
| 67 | Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRTH specification Clauses 1313, 1411 and 2206.6. 75 mm thick |
| 68 | Part - \"I\" Road Furniture |
| 69 | S & F in position precast R.C.C. stone (M-15 mix) of standard IRC design including finishing in cement sand mortar 1:3, painting with enamel paint, printing letters and numerals etc. complete (MoRTH specifications clause : 800). 5th km stone |
| 70 | S & F in position precast R.C.C. stone (M-15 mix) of standard IRC design including finishing in cement sand mortar 1:3, painting with enamel paint, printing letters and numerals etc. complete (MoRTH specifications clause : 800). Ordinary km stone for NH |
| 71 | S & F in position precast R.C.C. stone (M-15 mix) of standard IRC design including finishing in cement sand mortar 1:3, painting with enamel paint, printing letters and numerals etc. complete (MoRTH specifications clause : 800). 200 m stone |
| 72 | Supplyofinformatory reflective sign boards made out of 2 mm thick M.S. sheet, stove enamelledpaintasperIRC - 67(latest revision) fixed on angle iron of size 65 x 65 x 6 mm of 3 m long. 600 x 800 mm with size of square 400 mm |
| 73 | Providing and laying of hot applied thermo plastic compound inclusive of type-1 reflectorising glass beads as per table 800.3, 800.4 applied in uniform thickness of at least 2.5 mm and spread uniformlywith reflectorising glass beads type-2 in addition @ 250 gm/scm with a road marking machine as per IRC : 35 complete with traffic diversion arrangement as per MoRTH specification clause 803.4. |
| 74 | Supplying & fixing of Cat’s Eye made of aluminium alloy size 75x100x22 mm having 21 biconvex lenses embedded in circular disk of ABS plastic on Each side. |
| 75 | P&F delinator with 30 cms diaRCC hume pipe ( IS-Marked) pipe 1.00M long 40 cms embedded in earththe inside of pipe shall be filled with cement concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 coarse aggregate 20 mm nominal size ) with semi circular hump at top the pipes shall be painted 15 cms wide alternate strips with black/ white with enamel paint (Black strip at top) with red round reflector 7.5 cms dia at top on side facing the traffic and opposite side (as per IRC -79 ) |
| 76 | Supply of Village Name Board size 600 x 900 mm made out of 1.25mm thick M.S. sheet duly framed with 30 mm ODMS tube tightened with M.S. flat 12 x 3 mm fixed on two posts of size 40 mm ODMS tube 3m long whole board is processed in blue/white stoving enamel paint and white / red machine cut reflective sheet complete in all respect posts duly painted with black/white synthetic enamel. |
| 77 | Supply of direction and place identification sign boards made out of 2mm thick sheet framed to angle iron 40 x 40 x 5 mm and two vertical posts of angle size 65 x 65 x 6 mm, 3 m long with hold fasts, stove enamelled paint and reflective letters,numerals,symbols etc. complete of size : 900 x 600 mm |
| 78 | Supply of direction and place identification sign boards made out of 2mm thick sheet framed to angle iron 40 x 40 x 5 mm and two vertical posts of angle size 65 x 65 x 6 mm, 3 m long with hold fasts, stove enamelled paint and reflective letters,numerals,symbols etc. complete of size : 1500 x 1200 mm |
| 79 | Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ ground level, fixed on CRC rolled channel vertical post, 150 x 75 x 5 mm spaced 2 mm centre to centre, 1.8 m high, 1.1 m below ground / road level, all steel parts and fitments to be galvanized by hot dip process, all fittings to conform to IS: 1367 and IS: 1364 , metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per MoRTH specification Clause 810. |
| 80 | P& F Mukhya Mantri Sadak Yojana logo for roads funded by State road fund having M.S. Definition plate of 1.6mm thickness frame to steel hollow dsection of 75mm x 75mm, 2.5m long stove enamelled paint with hold fast including paint logo as per approved design and colours. The logo shall be made out of 1.6mm thick circular plate fix on 1200mm x 150mm rectangular steel base plate 1.6mm thick, the base of circular shall be plain at the junction of base plate. The size of definition plate shall be 1500x600mm and embedding the posts by M-15 mix C.C. block 300x300x600 mm including lettering / writing and painting etc. complete in all respect |
| 81 | Supply of Shevron sign of size 600x450 mm made out of aluminum sheet 2 mm thick both side with fixing provision on M.S. angle iron post 50x50x6 mm 3 M long screwed with stainless steel nut bolts of 8 mm dia, plate is covered by high intensity grade retro-reflective sheeting and black reflective arrow, complete in all respect. |
| 82 | PART-J :-Plantation Work |
| 83 | Digging holes in all kinds of soil and refilling the same with the eaxcavated earth mixed with well decayedfarmyard manure (cost of well decayed farm yard manure to be paid separately).Hole 1.2 m dia and 1.2m deep |
| 84 | Supply of different varities of plants in polyethyiene bags / earthen pots according to height growth & age of the plant at site inclduing loading unloading & transportation etc complete |
| 85 | Spreading of sludge farm-yard manure or/and good earth in required thickness (cost of sludge, farm-yard manure or/and good earth to be paid for saparately). |
| 86 | Mixing earth and sludge or farmyard manure in proportion specfied or as directed. |
| 87 | Half brick circular tree guard in second class bricks, internal dia 1.25 metres, and Ht. 1.2 metre above ground and 0.2 metres below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 Cement, 6 Sand) and the intermediate courses being in dry honey comb masonry, as per design complete. |
| 88 | Maintenance of plants by the contractor including of pits/bids watering preparation of Thavala Hoeing weeding etc. & application of insecticieds etc. & securityif the plant die during maintenance contractor has to replace same height plant at his own cost. |