Tender For Repair / Maintenance of Ro Plants At Various Location& Electric Water Heaters Under Age (I) Coast Guard Noida.; 1 Serevicing of existing domestic RO plant of capacity 15 LPH of Make- KENT Model-grand+ and including attending Complaint for RO plants within 24 hours of intimation at CG, Sector 52 Noida and carry out all repairs such as electric connection, tightening of components, water connection, stoppage of water leak and other minor repairs as reqd to make RO fully functional including replacement of washer, small lengths of electric wire, interconnecting water pipes with fittings, nut bolts, insulation tape, gasket etc complete all as directed.Note :-(i) The scope of work includes checking the performance of RO System and submitting a report after every visit. The scope of work include: unit checkup and general cleaning, chemical cleaning of cartridge, if required and checking TDS after very service/complaintii) In case of any complaint/ breakdown/fault in any equipment, the firm has to attend the same within 24 hours of reporting on phone/FAX/ Email etc. failing which a penalty for per complaint as follows will be applicable:-a. Attending to complaint between 48 hours — 4 days of intimation- Rs. 200/-b. Attending to complaint between 5 days to 7 days of intimation- Rs. 500/-c. Attending to complaint beyond 7 days - Rs. 1000/-iii) During attending complaint it shall be ascertained by deptt and contractor wheather replacement of part/servicing of plant is reqd. In case during servicing of plant,relacement of any item found necessary then these shall be measured and paid in addition as indicated subsequent items of BOQiv) Contractor has to submit the Complaint slips duly signed by User 2 S&F in replacementPre filter Housing complete suitable for 15 LPH RO plant 3 S&F in replacement Pre filter element for 10 filter suitable for 15 LPH RO plant.Make-Kent or equivalent. 4 S&F in replacement in-line sediment filter suitable for 15 LPH RO plant.Make- KENT./Filmtec/CSM/Hydranautics. 5 S&F in replacement In-line active carbon filter suitable for 15 LPH RO plant . Make :- Kent/Filmtec/CSM/Hydranautics. 6 S&Fin replacement Membrane with housing sealed typesuitable for 15 LPH RO plantMake-Kent, Filmtech/CSM/Hydranautics. 7 S&F in replacement Membrane 4complete set suitable for 15 LPH RO plant. 8 S&F in replacement of Post carbon filter complete suitable for 15 LPH RO plant all as directed.Make- Kent or Equivalent. 9 S&F in replacement diaphragm pump AQ&Q E-100 GPD.Make-Kent or equivalent. 10 S&F in replacement TDS adjuster for Kent RO suitable for 15 LPH RO plant 11 S&F in replacement FRT (Flow Reducer Tubes) suitable for 15 LPH plant . Make- Kent or equivalent. 12 S&F in replacementDC Adopter for motor suitable for 15 LPH RO plant. Make- Kent or equivalent. 13 S&F in replacement UV Lamp 11 watt T5 for Kent RO.Make- Phillips/Havells/Bajaj. 14 S&F in replacement PVC outletwater Tap suitable for 15 LPH RO plant Make-Kent or equivalent. 15 S&F in replacement UV barrel suitable for 15 LPH RO plant.Make- Kent orEquivalent. 16 S&F in replacement Solonied Valve for 15 LPH Kent RO.Make- Philips / Bajaj/ havells or equivalent 17 S&F in replacement Float valve accessory complete except switch suitable for 15 LPH RO plant.Make- Kent or equivalent. 18 S&F in replacementHydrosrtatic tank15 ltrs capacity.Make-Kent or equivalent. 19 S&F in replacement Low pressure switchsuitable for 15 LPH RO plant.Make- Kent or equivalent. 20 S&F in replacement UV Choke suitable for 15 LPH RO plant.Make Phillips or equivalent 21 S&F in replacement Float Switch suitable for 15 LPH RO plant all as directed 22 S&F in replacementmotor head for diaphragm pump suitable for 15 LPH RO plant all as directed 23 S&F in replacementMisc fittings Elbow and connectors such as Sediment Filter, Diaphram pump,Membrane & Pre-filter Elbows different type, one side and 2 side push complete all as directed 24 Servicing of existing domestic RO plant of cap 50/60 LPH Make- KENT, Model-Elite-IIincluding attending Complaintwithin 24 hours of intimation at CG location, Sector 24 Noida and carry out all repairs such as electric connection, tightening of components, water connection, stoppage of water leak and other minor repairs as reqd to make RO fully functional including replacement of washer, small lengths of electric wire, interconnecting water pipes with fittings, nut bolts, insulation tape, gasket etc. all as directedNote :-(i) The scope of work includes checking the performance of RO System and submitting a report after every visit. The scope of work include: unit checkup and general cleaning, chemical cleaning of cartridge, if required and checking TDS after very service/complaintii) In case of any complaint/ breakdown/fault in any equipment, the firm has to attend the same within 24 hours of reporting on phone/FAX/ Email etc. failing which a penalty for per complaint as follows will be applicable:-a. Attending to complaint between 48 hours — 4 days of intimation- Rs. 200/-b. Attending to complaint between 5 days to 7 days of intimation- Rs. 500/-c. Attending to complaint beyond 7 days - Rs. 1000/-iii) During attending complaint it shall be ascertained by deptt and contractor whether replacement of part/servicing of plant is reqd. In case during servicing of plant,relacement of any item found necessary then these shall be measured and paid in addition as indicated subsequent items of BOQiv) Contractor has to submit the Complaint slips duly signed by User 25 S&F in replacementPre filter Housing Suitable for 50/60 Ltrs RO Complete all as directed. 26 S&F in replacementPre filter element for 20 filter Suitable for 50/60 Ltrs RO Complete all as directed.Make-Kent or equivalent. 27 S&F in replacement forIn-line sediment filter Candel Suitable for 50/60 Ltrs RO Complete all as directed.Make- KENT /Filmtec /CSM /Hydranautics. 28 S&Fin replacement In-line active GAC & CTO carbon filtre cartage Suitable for 50/60 Ltrs RO Complete. Make :- Kent /Filmtec /CSM/Hydranautics. 29 S&F in replacement membrane candle suitable for 50/60 Ltrs RO CompleteMake-Hi Tech model no. BW30-4021 or equivalent as existing. 30 S&Fin replacement diaphragm pump 48 VoltSuitable for 50/60 Ltrs RO Complete.Make-Kent or equivalent. 31 S&F in replacementTDS adjuster for Kent RO Suitable for 50/60 Ltrs RO Complete 32 S&F in replacementFRT as per existing suitable for 50/60 Ltrs RO Complete. Make- Kent or equivalent. 33 S&F in replacementDC Adopter 48 Voltfor motor Suitable for 50/60 Ltrs RO Complete.Make- Kent or equivalent. 34 Servicing of skid mounted type RO (Reverse osmosis) plants of capacity 50 LPH Make- EUKAWA installed atSector-62 including necessary dismantlingrepairing, cleaning with clean water and back washing with water pressure and refixingof RO plant after reassembling in position. Note :-(i) The scope of work includes checking the performance of RO System and submitting a report after every visit. The scope of work includes: unit checkup and general cleaning, chemical cleaning of cartridge, if required and checking TDS after very service/complaint.ii) In case of any complaint/ breakdown/fault in any equipment, the firm has to attend the same within 24 hours of reporting on phone/FAX/ Email etc. failing which a penalty for per complaint as follows will be applicable:-a. Attending to complaint between 48 hours — 4 days of intimation- Rs. 200/-b. Attending to complaint between 5 days to 7 days of intimation- Rs. 500/-c. Attending to complaint beyond 7 days - Rs. 1000/-iii) During attending complaint it shall be ascertained by deptt and contractor whether replacement of part/servicing of plant is reqd. In case during servicing of plant,replacement of any item found necessary then these shall be measured and paid in addition as indicated subsequent items of BOQiv) Contractor has to submit the Complaint slips duly signed by User 35 S&F in replacementPre filter Housing suitable for 50 Ltrs EUKAWA RO complete all as directed. 36 S&F in replacement Pre filter element suitable for 50 Ltrs EUKAWA RO complete all as directed. 37 S&F in replacement in-line sediment filter Candle suitable for 50 Ltrs EUKAWA RO complete all as directed.Make- EUKAWA /Filmtec/CSM/Hydranautics. 38 S&F in replacementIn-line active GAC & CTO carbon filtre cartage suitable for 50 Ltrs EUKAWA RO complete all as directed.Make :- EUKAWA/Filmtec/CSM/Hydranautics. 39 S&F in replacementMembrane Candle suitable for 50 Ltrs EUKAWA RO complete all as directed.Make:-EUKAWA , Filmtech /CSM /Hydranautics. 40 S&F in replacementDiaphragm pump 48 Volt suitable for 50 Ltrs EUKAWA RO complete all as directed.Make-EUKAWA or equivalent. 41 S&F in replacementTDS adjuster suitable for 50 Ltrs EUKAWA RO complete all as directed 42 S&F in replacementFRT suitable for 50 Ltrs EUKAWA RO complete all as directed. Make- EUKAWA or equivalent. 43 S&F in replacementDC Adopter 48 Voltfor motor suitable for 50 Ltrs EUKAWA RO complete all as directed. Make- EUKAWA or equivalent. 44 Note : (a). Once the geyser is down off then it shall be inspected by deptt and may order major repair/replacement of any part which shall be paid seperately.(b)Any damage if occurred during the process of cleaning the geyser will be made good by contactor at no extra cost.(c) A proper bound register shall be maintained showing details of repair /replacement, date of taking off, date of refixing. This register shall have signature of contractor, MES Rep and Rep of User. A Geyser after taking off shall be refixed on the day when it was taken off unless ordered for painting /major repair/replacement of parts. In this case the geyser shall be refixed within 48 hours from taking off failing which a recovery of Rs 100.00 per day or part thereof shall be deducted from contractors dues.(d) No Extra cost for transport will be paid for repairs to Market. (e) Painting of geyser and major repairs shall be carried out in a place at sec 23 Noida (f) Contractor will provide minimum 50% of material or as required within 10 days of commencement of work. 45 Taking down electric water heater/geysers of capacity 25/35/50 ltrs and of any make from its mounting place, opening it for descaling /cleaning ofinner tank from deposited scales with descaling solutionincluding checkingleak, testing, sealing of joints, carrying out the minor repair on surface of outer body, bottom and top cover,andre-fixing the geyser in same position. 46 S&F in replacement geyser element of 1.5 KW rating double tube type with cup type or circular/triangle shape includingrubber washerssuitable to fitin the existing geyser without any water leakage completeall as specified and as directed by Engr-in-Charge . Make : Micron King/Bajaj/Recold/thita/havells. 47 S&F in replacement ceramic heating element of 2 KW rating round long rod shape (construction of element on Ceramic) completeall as specified and as directed. Make : Micron King/Bajaj/Recold/thita/havells. 48 S&F in replacement Gasket (heat proof rubber)for apparatus plate suitable for the different make of 25/35/50litres capacitygeysers as per site requirement complete all as specified and as directed. 49 S&F in replacement heavy dutyelement holding assembly/ apparatus plate made out of copper and chromium plate (different 6/9 hole or as per site requirement) with provision for safety valve in its inlet and outlet, pocket for thermostat/ thermal cut system and drain plug all as per site requirementsuitable for 25 litres capacity geysers.Make as per existing or compatibleas approved ISI marked 50 S&F in replacement heavy dutyelement holding assembly ( different type hole or without hole) with provision for safety valve in its inlet, pocket for thermostat/ thermal cut system and drain plug all as per site requirement and directed by engineer in charge suitable for50 litrescapacity geysers. Make : Make as per existing or compatibleas approved ISI marked 51 S&F in replacement stainless steelinner tank heavy dutyof steel inner tankhaving pressure bearing capacity of 6 Kg/cm2 suitable tothe existing25 ltrscapacity geysers, complete with nut, bolt and washer, all as specified and as directed.Make Bajaj/Recold/Jaguar /USHA.Note : Only OEM manufacture SS tank will be accepted. 52 S&F in replacement stainless steelinner tank heavy duty having pressure bearing capacity of 6 Kg/cm2 suitable tothe existing50 ltrs capacity geysers, complete all as specified and as directed.Make Bajaj/Recold/Jaguar /USHANote : Only OEM manufacture SS tank will be accepted. 53 S&F in replacement the thermostat 7 longfor the geysers 25 Ltrs capacity.Make Bajaj/Digits/Recold/DASS PASS/THETA/Micron King 54 S&F in replacement thermostat 11 longfor the geysers 25/35/50 Ltrs capacity.Make Bajaj/Digits/Recold/DASS PASS/THETA/Micron King 55 S&F in replacement multiple use safety valve / PRV 15mm, bore for geyser inlet or all asspecified and as directed. 56 S&F in replacement steel ribbed connection pipe 450 mm long heavy duty (Hot water) with two brass nut and nylon washer suitable for 15mm dia inlet and outlet pipeof geyser and connecting up complete, all as specified 57 S&F in replacement steel ribbed connecting pipe 600 mm length heavy duty (Hot water) with two brass nut and nylon washer suitable for 15mmdia inlet and outletpipe of geyser and connecting up complete, all as specified and as directed. 58 S&F in replacement of the insulating material i.e. glass wool, complete all as specified and as directed. 59 S&F in replacement of indicating lamp Red or Green as per Geyser suitability complete all as specified and as directed. 60 S&F in replacement of outer body made/fabricated of 20 SWG MS sheet for Geysers of 25 ltrs capacity duly painted with spray paint with clamps 2 Nos of size 15mmx1mm thick with necessary nut and bolts complete all as specified and as directed. 61 S&F in replacement Geyser Heating Element assembly2000 watt (in Round Shape bottom Assembly) with arrangement of 6 Nut bolt, One no suitable round rubber gasket including one magnesium Rodas required in Bajaj Geyser of Model No CALDIA 25 (150756) complete all as directed.Make Bajaj/Recold/Theeta (As per Sample held with AGE I office). 62 S&F in replacement of geyser heating element suitable for Recold make geyser of capacity 25 Ltrs including nut,bolt,washer etc complete all as specified and directed.Make: Racold or as per existing sample. 63 S&F in replacement of geyser thermostat suitable for Recold make geyser of capacity 25 Ltrs including nut,bolt,washer etc complete all as specified and directed. Make: Racold or as per existing sample.