Tender For Supply Of Spares For Siemens Make Lt Switchgear Of Chp And Main Plant Unit I To Iv Of Ctpp Chhabra, chhabra-Rajasthan

Rajasthan Rajya Vidyut Utpadan Nigam Limited has published Tender For Supply Of Spares For Siemens Make Lt Switchgear Of Chp And Main Plant Unit I To Iv Of Ctpp Chhabra. Submission Date for this Tender is 28-10-2024. Fuses Tenders in chhabra Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45787037
Tender For Supply Of Spares For Siemens Make Lt Switchgear Of Chp And Main Plant Unit I To Iv Of Ctpp Chhabra
Open Tender
Indian
Rajasthan
Chhabra
28-10-2024

Tender Details

Supply Of Spares For Siemens Make Lt Switchgear Of Chp And Main Plant Unit I To Iv Of Ctpp Chhabra , Power Contactors. (Coil Voltage -110Vac) , 9A, 3Pole, Ac3 , 9 Amp, 3Pole, Ac3 , 12A, 3Pole, Ac3 , 12A, 3Pole, Ac3 , 16A, 3Pole, Ac3 , 22A, 3Pole, Ac3 , 32A, 3Pole, Ac3 , 40 Amp, 3Pole, Ac3 , 45 Amp, (Aux Contact2no+2 Nc.), 3Pole, Ac3 , 63 Amp, (Aux Contact2no+2 Nc.), 3Pole, Ac3 , 85A, 3Pole, Ac3 , 110A, 3Pole, Ac3 , 140 Amp(Aux.Contact 2No+ 2Nc) , 170 Amp(Aux.Contact 2No+ 2Nc) , 205 Amp(Aux.Contact 2No+ 2Nc) , Power Contactors. (Coil Voltage -24Vdc) , 9A , Power Contactors. (Coil Voltage -220Vdc) , 9A , 32A, 3Pole, With 1No+1Nc , Power Contactors. (Coil Voltage -230Vac) , 9A, 3Pole, Ac3 , 16 Amp , 32A, 3Pole, Ac3 , 32A, 3Pole, Ac3 , 140A, 3Pole, Ac3 , 300A, 3Pole, Ac3 , Power Contactors. (Coil Voltage -415Vac) , 9A, 3Pole, Ac3 , 32A, 3Pole, Ac3 , 40Amp, 3Pole, Ac3 , 70Amp, 3Pole, Ac3 , 250A, 3Pole, Ac3 , Auxiliary Contactors. (Coil Voltage -110Vac) , 4No , 3No+1Nc , 2No+2Nc , Auxiliary Contactors. (Coil Voltage -230Vac) , 4No , 3No+1Nc , 2No+2Nc , Auxiliary Contactors. (Coil Voltage -220Vdc) , 4No , 3No+1Nc , 2No+2Nc , Add On Block/Side/Front Mounted Aux. Contacts Block. , 1No , 1Nc , 1No (Extd) , 1Nc (Extd) , 1No+1Nc Left/Right , Window Type Current Transformer: 400/5 A, 50 Hz, 5 Va, Class 1 , Sparecoils Forcontactors Coil Voltage-110Vac , 3Tf30-33 , 3Tf34/35 , 3Tf46/47 , 3Tf48/49 , 3Tf50/51 , 3Tf52/53 , 3Tf54/55 , Spare Ac Coils For Contactors (Coil Voltage -230Vac) , 3Tf50/51 , 3Tf55 , Spare Ac Coils For Contactors. (Coil Voltage -415Vac) , 3Tf54 , Main Contact Kits(Set Of 6 Fixed & 3 Moving Contacts) , 3Tf32 (16A) , 3Tf33(22A) , 3Tf34(32A) , 3Tf35(40A) , 3Tf46(45A) , 3Tf47(63A) , 3Tf49(85A) , 3Tf50(110A) , Thermal O/L Relays. , Range: 0.63-1A , Range: 1-1.6A , Range: 1-1.6A , Range: 1.25-2A , Range: 2.5-4A , Range: 2.5-4A , Range 3.2-5 Amp , Range: 5-8A , Range 4-6.3 Amp , Range: 6.3-10A , Range 6.3-10 Amp , Range 8-12.5 Amp , Range 10-16 Amp , Range 20-32 Amp , Range: 12.5-20A , Range: 16-25A , Range: 40-57A , Range: 70-95A , Range: 85-105A , Range: 95-120A , Range 125-200 Amp , Mpcb , 0.45 -0.63 Amp, 415V Ac, 3 Pole , 8-13A, 415 Ac, 3 Pole , 35-45Amp, 415V Ac, 3 Pole , Range 3.2-5.0 Amp With 1No+ 1Nc , Range 1-1.6 Amp With 1No+ 1Nc , Range 6-10 Amp With 1No+ 1Nc , Range 10-16Amp With 1No+ 1Nc , Electronic Timer , On-Delay With 1C/O Contacts, 0.5 – 10 Sec, 110V Ac Coil , On-Delay With 1C/O Contacts, 5 – 100 Sec, 110V Ac Coil , On-Delay With 1C/O Contacts, 5 – 100 Sec, 230V Ac Coil , Off-Delay With 1C/O Contacts, 0.5 – 10 Sec, 110V Ac Coil , Off-Delay With 1C/O Contacts, 5 – 100 Sec, 110V Ac Coil , Off-Delay With 1C/O Contacts, 5 – 100 Sec, 230V Ac Coil , On-Delay, 0.05-100Hrs, 24-240V Ac/Dc , Overload Relay (Coil Voltage 220Vdc) , 160-250 A, Is 13947 Iec947ui1000 V , 400-630 A, Is 13947 Iec947ui1000 V , Sfu , 32Amp, , 32A, 690V Ac 50Hz Tpn Sdf Suitable For Bs Type Hrc Fuses , 63Amp , 63A, 690V Ac Tpn Switch Disconnector Fuse In Ss Enclosure Suitable For Din Type Hrc Fuse , 100Amp , 125A, 690V Ac Tpn Switch Disconnector Fuse In Ss Enclosure Suitable For Din Type Hrc Fuse , 160 Amp , 200 Amp , 315Amp, 2Pole , Mccb , 315Amp, 3P , 500Amp,3P , 630 Amp, 3P , 63 A, 415V Ac, 50Hz, 3 Pole, Thermal Magnetic Trip, Icu = 25 Ka, Ui = 800 V, Uimp = 8 Kv, Ics = 100%Icu, Adjustable Overload And Adjustable Short Circuit Setting , 32 A, 3 Pole,Thermal Magnetic Trip Unit, Fixed Thermal Fixed Magnetic (Ftfm), Ics = 100% Icu, 415Vac, 50Hz, Adjustable Overload And Adjustable Short Circuit Setting , Mccb-32Amp, 70Ka Breaking Capacity, Range 22-32 Amp, Thermal Magnetic Trip Unit, Adj. Thermal Fixed Magnetic (Atfm), Ics= 100% Icu, 415 Vac, 50Hz , Power Supply , Input:87-264Vac, 1A, 47-63Hz, Output:24Vdc/2A , Input 120/230V-500V 50/60Hz, Output:24Vdc/10A , Control Link , Rating: 20Amp , Thermal O/L Relays Mounting Kits , For Relay Type 3Ua58 30 , Acb Spares For Drawout 3Wt Acbs. , Motorized Operating Mechanism, 220V Dc , Shunt Relese Or Closing Coil, 220V Dc , Auxiliary Terminal Block , Auxiliary Switch Block , Front Facia Shutter For D/O Breaker, 800Amp. 3Wt8 Acb , Front Facia For Draw-Out 800Amp. 3Wt8 Acb , Front Facia For Draw-Out 3200Amp. 3Wt8 Acb , Safety Shutters For Guide Frames/Chasis, 3 Pole Size I, 800Amp. 3Wt8 Acb , Safety Shutters For Guide Frames/Chasis, 3 Pole Size Ii, 3200Amp. 3Wt8 Acb

Key Value

Document Fees
INR 590 /-
EMD
INR 59100.0 /-
Tender Value
INR 29.55 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail