}

Tender For Creation Of Receiving Station - 1 A-Supply Part 2 33 Kv Line Bay Of Single Bus Scheme 3 33 Kvvcb (36 Kv, 1250 A, 26.2 Ka, Outdoor Type) 4 33 Kv C&R Panel Along With O/C, E/F Relay (Iec 61850) Mimic Diagram, Voltmeter, Ammeter, Annunciat, doda-Jammu And Kashmir

Government Departments has published Tender For Creation Of Receiving Station - 1 A-Supply Part 2 33 Kv Line Bay Of Single Bus Scheme 3 33 Kvvcb (36 Kv, 1250 A, 26.2 Ka, Outdoor Type) 4 33 Kv C&R Panel Along With O/C, E/F Relay (Iec 61850) Mimic Diagram, Voltmeter, Ammeter, Annunciat. Submission Date for this Tender is 31-10-2024. Road Repair Tenders in doda Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

45786121
Tender For Creation Of Receiving Station - 1 A-Supply Part 2 33 Kv Line Bay Of Single Bus Scheme 3 33 Kvvcb (36 Kv, 1250 A, 26.2 Ka, Outdoor Type) 4 33 Kv C&R Panel Along With O/C, E/F Relay (Iec 61850) Mimic Diagram, Voltmeter, Ammeter, Annunciat
Open Tender
Indian
Jammu And Kashmir
Doda
31-10-2024

Tender Documents

Tender Details

Creation Of Receiving Station - 1 A-SUPPLY PART 2 33 KV LINE BAY OF SINGLE BUS SCHEME 3 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 4 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 5 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 6 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 7 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 8 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 9 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 10 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 11 STEEL STRUCTURES 12 Pipe Nominal bore 200, 5.9 mm thick 13 Galvanised steel structures 14 Galvanized nuts and bolts 15 CONTROL CABLES 16 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 17 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 18 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 19 Lugs & Ferrules etc. 20 CONDUCTOR AND HARDWARE 21 ACSR Conductor Panther 22 T-Clamp 23 Single Tension fitting 24 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 25 Earth Wire 7/4 sqmm 26 G.I Flat 50*6 mm 27 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY 28 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 29 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 30 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 31 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 32 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 33 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 34 STEEL STRUCTURES 35 Pipe Nominal bore 200, 5.9 mm thick 36 Galvanised steel structures 37 Galvanized nuts and bolts 38 CONTROL CABLES 39 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 40 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 41 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 42 Lugs & Ferrules etc. 43 CONDUCTOR AND HARDWARE 44 ACSR Conductor Panther 45 T-Clamp 46 G.I Flat 50*6 mm 47 33/11 KV, 10 MVA Power Transformer 48 33/11KV ONAN,10MVA Copper wound,outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 49 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 50 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 51 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 52 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 53 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 4 outgoings 54 11KV Gapless Surge Arrestor,9KV,10KA LA With polymer HousingStation Type 55 11KV (UE)XLPE Power Cables (Armoured) 56 11 kV630 mm² Single Core XLPE Cable (with one spare length) armoured, FRLS 57 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 58 11KVHeat shrink termination Cable Kits (Indoor) 630 mm square (1-core) 59 11KV Heat shrink termination Cable Kits (Outdoor) 630 mm square (1-core) 60 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 61 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 62 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 63 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 64 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 65 StT Poles 9 mtrs long 66 Galvanised iron of sorts 67 120 mm2 PVC 4 core cable,Armoured FRLS 68 MCCB 200 Amp 69 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 70 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 71 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 72 COMMON MISCELLANEOUS EQUIPMENTS 73 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 74 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 75 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 76 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 77 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 78 Civil Works 79 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 80 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 81 33/11kv power Transformer Foundation 82 33kv Equipment Foundation and gantry foundation 83 Earthing Mat complete job GI flat 50x8 mm 84 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 85 33kv Yard Concreting / Metalling 86 Underground Water tank 10000 Ltrs. 87 Control room Building including with internal wiringand fixing of electrical appliances like lights ,fans,geysers job 88 Shift Quarters for Je and SBA including internal wiring complete and fixing of electrical appliances like lights ,fans,geysers job 89 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 90 Development of identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 91 Yard Lighting ( 4 Nos yard and 02 Nos CR back side) on 9m Long Poles 92 CAPACITOR BANK 93 12 kV Capacitor Bank with VCB Panel with complete arrancement for conection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories. 94 SINGLE BUS OUT 95 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 96 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 97 33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor) 98 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 99 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port 100 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 101 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 102 STEEL STRUCTURES 103 Galvanised steel structures 104 Galvanized nuts and bolts 105 CONTROL CABLES 106 10 /12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 107 8 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 108 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 109 Lugs & Ferrules etc. 110 CONDUCTOR AND HARDWARE 111 ACSR Conductor Panther 112 T-Clamp 113 Single Tension fitting 114 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 115 Earth Wire 7/4 sqmm 116 G.I Flat 50*06 mm 117 ERECTION OF 33 KV LINE 118 11 Mtr. Long ST Pole(For new line) ST-410 SP56 119 GI Channel X-arm including clamps and braces 120 100 mm² ACSR DogConductor 121 PG Clamps for 100 mm² ACSR Conductor 122 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 123 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 124 Galvinized Nuts and Bolts. 125 Danger Plates with Clamps 126 Anti-Climbing Device with Clamps 127 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 128 Red Oxide 129 Aluminium Paint 130 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 131 Stone Pad (300 mm x 300 mmx 75 mm) 132 Aluminium Jointing Sleeves 133 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 134 Guard netting 135 SAFETY ITEMS 136 Rubber Mat 1m*2m (19mm thick) 137 Fire Extinguisher CO2 type of 4.5 Kg capacity for control room 138 3-Sand Bucket Fire Extinguisher 139 Helmet 140 Rubber Gloves for 33 KV Level 141 Rubber Gloves for 11 KV Level 142 SafetyBelt 143 Safety Shoes 144 Earthing rod (set of 3 rods) 145 HV Detector all Voltages 146 SPARE ITEMS (TO BE SUPPLIED TO DIVISIONAL STORES ) 147 Aluminium Ladder Sliding type 30 feet Long 148 Lifting and Puling machine 5 Ton 149 Come along Ratchet Upto Wolf Conductor 150 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 151 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 152 B- ERECTION PART 153 33 KV LINE BAY OF SINGLE BUS SCHEME 154 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 155 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 156 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 157 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 158 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 159 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 160 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 161 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 162 STEEL STRUCTURES 163 Pipe Nominal bore 200, 5.9 mm thick 164 Galvanised steel structures 165 Galvanized nuts and bolts 166 CONTROL CABLES 167 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 168 4 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 169 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 170 Lugs & Ferrules etc. 171 CONDUCTOR AND HARDWARE 172 ACSR Conductor Panther 173 T-Clamp 174 Single Tension fitting 175 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 176 Earth Wire 7/4 sqmm 177 G.I Flat 50*6 mm 178 SUB-STATION MAIN EQUIPMENT TRANSFORMER BAY 179 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 180 33 KV Isolatorwithout earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 181 33 KV Current Transformer (33KV,Single Phase,Multi ratio,multi core ,Outdoor) 1 No per Phase 182 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 183 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 Phase Trivector meter DLMS compliant RS 485 port 184 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 185 STEEL STRUCTURES 186 Pipe Nominal bore 200, 5.9 mm thick 187 Galvanised steel structures 188 Galvanized nuts and bolts 189 CONTROL CABLES 190 12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 191 6 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 192 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 193 Lugs & Ferrules etc. 194 CONDUCTOR AND HARDWARE 195 ACSR Conductor Panther 196 T-Clamp 197 G.I Flat 50*6 mm 198 33/11 KV, 10 MVA Power Transformer 199 33/11KV ONAN,10MVA Copper wound,outdoor type,Conventional Power transformer,Oil filled with OLTC and all accessories including HT and LT Terminal connections with busbars 200 12 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 201 6 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 202 2 Core 2.5mmsq Control Cable Copper Armoured,1.1KV Grade .ISI .FRLS 203 Cost for 11 KV Indoor Switchgear of 33/11 kv Substation (Transformer Bay Scheme) 204 11 KV VCB Panel Board ( 12KV,1250A,25KA, Outdoor ) With over current,earth fault relays (IEC 61850),MIMIC diagram,Voltmeter,Ammeter,annuniaciation windows with annunciation relays,Hooter on individual Panels ,3-phase tri vector meter-5A,DLMS Compliant with RS-485 Port1 Incoming & 4 outgoings 205 11KV Gapless Surge Arrestor,9KV,10KA LA With polymer HousingStation Type 206 11KV (UE)XLPE Power Cables (Armoured) 207 11 kV630 mm² Single Core XLPE Cable (with one spare length) armoured, FRLS 208 11 kV (UE) 3-Core XLPE 120 mm² armoured, FRLS 209 11KVHeat shrink termination Cable Kits (Indoor) 630 mm square (1-core) 210 11KV Heat shrink termination Cable Kits (Outdoor) 630 mm square (1-core) 211 11KV Heat shrink termination Cable Kits (Indoor) 120 mm square(one spare) (3-core) 212 11KV Heat shrink terminationCable Kits (Outdoor) 120 mm square (one spare) (3-core) 213 11 KV isolator, double break, 3 pole, 600 Amp. Horizental mounting type with earth switch Complete 214 11KV GO Set, AB switch 3 phase, 3 pole, 400 Amps. 215 100 KVA, 11/.433 KV,Auxiliary Transformer,3 Phase Distribution Transformer with bimetallic terminal connectors ,energy level -2,Al Wound. 216 StT Poles 9 mtrs long 217 Galvanised iron of sorts 218 120 mm2 PVC 4 core cable,Armoured FRLS 219 MCCB 200 Amp 220 Cement bottomng 1:2:4 mix as per REC standards 0.5cum per pole 221 Earthing of 100KVA substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm& 50 mm x 6 mmfor connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 222 Earthing complete GI pipe 40 mm or GI rod 20mm 2.5 mtr long through G.I Strip 223 COMMON MISCELLANEOUS EQUIPMENTS 224 a) Battery Bank 30 V, 100 AH, of 15 No. cells of 2 V each, sealed maintenance free VRLA type, high impact Polyprophelene copolymer container, flame retardant with stand 225 b) 30 V, 100 AH, float-cum-boost charger with full wave rectification for 220 V, 1 phase, 50 HZ AC input supply. 226 Distribution panel (30V, DC) made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 for two number battery incoming supplywith 2No. 63 Amp. DP MCB for incoming supplydouble bus bar of adequate size,twelve number DP DC MCB(0-32A) including indication lamp and cables and other accessories 227 Distribution panel (415 V, AC)made of CRCA thickness not less than 2 mm ,Powder coated degree of protection IP 43 200A Switch fuse disconnector for incoming supply and five numbers TPN MCBs(16-125A) and five number DP MCB(0-32A),rectangular bus bar suitable for 200 A continous supply including indication lamp cables and other accessories. 228 Telecommunication facilities including cctvs set (4nos cameras ) LED Display (32) 229 Civil Works 230 Compound walling of identified land by way of Mass Concrete in Foundation and 228mm bricks of 2M height 231 Chain-link Fencing of 33kv Yard of Substation by way of Mass Concrete in Foundations and chain-link fencing of 6 ft height. 232 33/11kv power Transformer Foundation 233 33kv Equipment Foundation and gantry foundation 234 Earthing Mat complete job GI flat 50x8 mm 235 Earthing electrode ( 3 meters long, 40 mm dia GI pipe) through GI strips 236 33kv Yard Concreting / Metalling 237 Underground Water tank 10000 Ltrs. 238 Control room Building including with internal wiringand fixing of electrical appliances like lights ,fans,geysers job 239 Shift Quarters for Je and SBA including internal wiring complete and fixing of electrical appliances like lights ,fans,geysers job 240 Truss for control room building 1.3xPlinth area .Providing and fixing of Steel Truss including provision for colur coated Roofing 241 Development of land identified land by way of removing weeds, wild grass and undulation if any, ornamental land scraping and growing of ornamental trees in un built areas and road sides and development of road along with surface drain. 242 Yard Lighting ( 4 Nos yard and 02 Nos CR back side) on 9m Long Poles 243 CAPACITOR BANK 244 12 kV Capacitor Bank with VCB Panel with complete arrancement for conection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories. 245 SINGLE BUS OUT 246 33 KVVCB (36 KV, 1250 A, 26.2 KA, outdoor type) 247 33 KV Isolatorwith earthing blade(36 KV ,1250A.Outdoor.3 pole,25KA) 248 33 KV Current Transformer (Single Phase,Multi ratio,multi core ,Outdoor) 249 30 KV Lightening Arrestor (30KV,10KA,Station Class.ZNO.Polymer) Gapless 250 33 KV C&R panel along with O/C, E/F relay (IEC 61850) Mimic diagram, voltmeter, ammeter, annunciation windows with annunciation relays, 3 PHASE Trivector meter DLMS compliant RS 485 port 251 33 kv Post Insulators polymer type , 36 kv, 235 kv impulse, creepage distance 1224 mm 252 33 KV PT (33KV/110V,1phase,multicore,Outdoor)(1No per phase) 253 STEEL STRUCTURES 254 Galvanised steel structures 255 Galvanized nuts and bolts 256 CONTROL CABLES 257 10 /12 core 2.5 mm2, copper armoured, 1.1 kv grade, ISI FRLS 258 8 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 259 2 core 2.5 mm2copper armoured, 1.1 kv grade, ISI FRLS 260 Lugs & Ferrules etc. 261 CONDUCTOR AND HARDWARE 262 ACSR Conductor Panther 263 T-Clamp 264 Single Tension fitting 265 PolymerComposit type Disc Insulators.36KV Lighting bimpulse 170KV Positive and 180KV Negative,Creepage distance 900mm,Minimum failing load70 KN 266 Earth Wire 7/4 sqmm 267 G.I Flat 50*06 mm 268 ERECTION OF 33 KV LINE 269 11 Mtr. Long ST Pole(For new line) ST-410 SP56 270 GI Channel X-arm including clamps and braces 271 100 mm² ACSR DogConductor 272 PG Clamps for 100 mm² ACSR Conductor 273 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 274 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fittings 275 Galvinized Nuts and Bolts. 276 Danger Plates with Clamps 277 Anti-Climbing Device with Clamps 278 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 279 Red Oxide 280 Aluminium Paint 281 Cement bottoming 1:2:4 mix as per REC standards .6cum /pole 282 Stone Pad (300 mm x 300 mmx 75 mm) 283 Aluminium Jointing Sleeves 284 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 285 Guard netting

Key Value

Document Fees
INR 4000 /-
EMD
INR 920000.0 /-
Tender Value
INR 4.60 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail