| 1 | M&L for dismantling geyser of 25/35 Ltr capacity of any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaningthe inner tank properly, painting with sparay gun and re-assembling the same and refixing to its existing location or new location with testingfor its proper functioning, complete all as specified and directed.Note: If any spares required then supplied and measured separately under relevant item. |
| 2 | All as per item No 1.00 above but 50/100 Ltr Capacity complete all as specified and directed. |
| 3 | Supply only inner container suitable for vertical type geyser 25 ltrs storage capacityincluding taking down of defective container complete all as specified and directed. |
| 4 | All as per item No 3.00above here in before but 50 Ltr Capacity complete all as specified and directed. |
| 5 | All as per item No 3.00 above but 100 Ltr Capacity complete all as specified and directed. |
| 6 | S&F in repair Thermostat 0-80 Degree as per exiting size including taking down of defective thermostat complete all as specified and directed |
| 7 | S&F heating element1000/ 1500 watt with studs, bolts, rubber washer suitable for existing type (triangular /round ) of geyser including taking out of old unserviceable element complete all as directed. |
| 8 | All as per item No 7.00 above but 2000 watt, complete all as specified and directed. |
| 9 | S & F in repair Indicator lamp with flexibe copper wire of suitable sizeRed/ Greenincluding taking down of defective indicator lamp complete all as specified and directed. |
| 10 | S&F stainless Steel grade chromium finish connection pipe 15 mm dia with adopter, washer 450 mm long including making in shape complete all as specified and directed. |
| 11 | S&F PVC connection pipe, 15 mm dia, 450 mm long with brass adopter & washer on both sides complete all as specified and directed. |
| 12 | S&F Non return valve, 15 mm dia brass/GM, complete all as specified and directed. |
| 13 | S&F aperture plate SS suitable for 25/50 ltrs geyser along with rubber gasket, nuts, bolts, etc. complete including taking down of defective aperture plate complete all as specified and directed |
| 14 | S&F in repair hot water pipe insulation with glass wool and aluminium cladding 20 mm bore including all material complete as per OEM recommendation complete all as specified and directed |
| 15 | S&F to walls , floorand ceiling 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 with and including taking down existing unserviceable complete all as specified and directed. |
| 16 | All as per Srl item No.15.00 above but of size 20 mm bore, complete all as specified and as directed. |
| 17 | All as per Srl item No.15.00 above but of size 15 mm bore, complete all as specified and as directed. |
| 18 | S&F Stop valves, 20mmcast copper alloy, screwed down, high pressurewith butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. |
| 19 | All as per item No 18.00 above herein before but fancy type, chromium plated with angle valve STP cock suitable for geyser (cold & hot) concealed type, complete all as specified and directed. |
| 20 | S&F 15mm bore Gun-metal, globe or gate valves,with iron wheelhead, screwed both ends for ironpipe and fixed complete all as specified and directed. |
| 21 | All as per Srl item No. 20.00 above but of size 20 mm bore complete all as specified and directed. |
| 22 | All as per Srl item No. 20.00 above above but of size 25mm bore complete all as specified and directed. |
| 23 | S&F Plug top, 3 pin, 15 Amp, 230 volts complete all as specified and directed. |
| 24 | S&F Metal Plug top, 3 pin, 15 Amp, 230 volts complete all as specified and directed. |
| 25 | S&F PVCinsulated and sheathed 3 core copper conductor cable of size 2.5 Sqmm 3 core suitable for geyser, complete all as specified and directed. |
| 26 | S&F PVC insulated PVC sheathed 1.0 sqmm copper cableincluding taking down complete all as specified and directed. |
| 27 | S&F Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB with \"B\" curve, 240 volt, 20 amps, including taking out, complete all as specified and directed. |
| 28 | S&F MCB SP (single pole ) 06 to 32 Amps \"B\" Curve with 10 kA for inductive load connected through cable lugs of suitable size complete all as specified and directed. |
| 29 | S&F Fastner for fixing of gyeser in existing wall, suitable size minimun 4 \"(02 Nos) complete all as specified and directed. |
| 30 | S&F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and directed. |
| 31 | M&L for PCC 1:3:6, type C-2,complete all as specified and directed. |
| 32 | S&F rolled mild steel as in roof trusses, framed trussed purlins rafter, crane gantries rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe-410-W(Gde E-250) Quality complete all as specified and directed. |
| 33 | M&L for point wiring 1.5 Sqmm (nominal cross sectional area) with colour coding multistranded copper conductor cable, PVC insulated (FRLS-H) and unsheathed cable and including drawn through PVC casing-capping size of 25x32 mmwiring with all fittings and accessories, terminated to PVC box for housing/ mounting the switches/ sockets including 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable earth wire connected to common earth dolly for one point on independent board control by one, one way switch 5 Amps, complete all as specified and directed. |
| 34 | All as per Srl item No 33.00 above but for one 3 pin 15 Amps power point on independent board with 2.5 Sqmm, complete all as specified and directed |
| 35 | S&F switch piano flush single pole, one way 5 Amp (ISI marked)complete all as specified and directed. |
| 36 | S&F switch piano flush single pole, one way 15 Amp (ISI marked)complete all as specified and directed. |
| 37 | S&F socket (ISI Marked) 2 in 1, 3 pin 5/6 amps flush type complete all as specified and directed. |
| 38 | S&F socket 2 in 1, 5 pin 5 and 15 amps (ISI marked) flush type universal, complete all as specified and directed. |
| 39 | M&L for rewinding/ repairing of blower fan motor of water coolerby disconnecting the electrical connection of burnt out electric outdoormotor of any make/model incl transportation to and for, taking out burnt out winding carefully and rewinding with high quality super enamelled copper wire of existing gauge & size including insulating material and varnish, bush, shaft, bearing etc complete for motor of suitable capacity includingremoval and re-fixing of the same, complete all as specified and dierected. |
| 40 | Supply & chargingR-410 gas for refrigerator /Deep Freezer etc and other appliances, (including Cylinder 5 KG), complete all as specified and dierected.Note:- Pipe line to be checked before filling the gas for leakage if any. |
| 41 | Supply & chargingR-134a gas forwater cooler and other appliances complete all as specified and dierected.Note:- Pipe line to be checked before filling the gas for leakage if any. |
| 42 | S&F in repair capacitor PVC1.5 MFD ±5%, 440V, AC, 50 Hz rectangular type including taking down of defective capacitor complete all as specified and directed. |
| 43 | S&F in repair capacitor of capacity 2 MFD ±5%, 220V, AC, 50 Hz including taking down of defective capacitor complete all as specified and directed. |
| 44 | S&F in repair capacitor of capacity 3.15 MFD ±5%, 220V, AC, 50 Hz including taking down of defective capacitor complete all as specified and directed. |
| 45 | S&F copper refrigerent piping size 1/4\" or 3/8\" suitable for cooling appliances including taking down complete all as specified and directed. |
| 46 | S&F copper refrigerent piping size 1/2 or 5/8\"suitable for cooling appliancesincluding taking down complete all as specified and directed. |
| 47 | S&F capillary tube suitable for cooling appliances including taking down complete all as specified and directed . |
| 48 | S&F temperature sensor suitable for cooling appliancesincluding taking down complete all as specified and directed. |
| 49 | S&F in repair Compressor for water cooler as per sample including taking down of defective compressor complete all as specified and directed. |
| 50 | S&F in repair motorassemblyof 230 V, 50 HZ,(as per existing),as per sample suitablefor Water cooler of any make and capacity complete all as specified and directed. |
| 51 | S&F in repairPotential relays suitable for Water cooler of any make/ capacity including taking down of defective relay complete all as specified and directed. |
| 52 | S&F OLP for Water cooler /Refrigerator of any make / capacity including taking down of defective OLP complete all as specified and directed. |
| 53 | S&F in repair thermostat switch suitable for water cooler of any make/ capacity including taking down of defective thermostat complete all as specified and directed. |
| 54 | S&F in repair capacitor aluminium body 6 MFD±5%, 440V, AC,50 Hz including taking down of defective capacitor complete all as specified and directed. |
| 55 | S&F in repair Capacitor of capacity 10 MFD, ±5%, 220V, AC, 50 Hz including taking down of defective capacitor complete all as specified and directed. |
| 56 | S&F in repair Capacitor of capacity 12 MFD, ±5%, 220V, AC, 50 Hz including taking down of defective capacitor complete all as specified and directed. |
| 57 | S&F Drain pipe for suitable for Water cooler of any make / capacity including taking down of defective drain pipe complete all as specified and directed. |
| 58 | S&F Chromium plated Push cock including taking down of defective tap complete all as specified and directed. |
| 59 | S&F in repair Compressor suitable for refrigerator 1/6or 1/8 including taking down of defective compressor complete all as specified and directed. |
| 60 | S&F PCB for suitable refrigerator of any make / capacity including taking down of defective PCB complete all as specified and directed. |
| 61 | S&F in repair Condenser coil suitable for Refrigerator of any make and capacity: including taking down of defective coil complete all as specified and directed. |
| 62 | S&F in repair Cooling coil with door and frame suitable for Refrigerator of any make and capacity including taking down of defective cooling coil complete all as specified and directed. |
| 63 | S&F in repair Thermostat switches suitable for Refrigerator of any make and capacity including taking down of defective thermostat complete all as specified and directed. |
| 64 | S&F in repair Potential relay suitable for Refrigerator of any make and capacity including taking down of defective relay complete all as specified and directed. |
| 65 | S&F Drier as per existing suitable for Refrigerator of any make and capacity including taking down of defective drier complete all as specified and directed. |
| 66 | S&F Bulb thread/pin type suitable for Refrigerator of any make and capacity including taking down of old complete all as specified and directed. |
| 67 | S&F Gasket set complete suitable for Refrigerator of any make and capacity including taking down of defective gasket complete all as specified and directed. |
| 68 | S&F Chiller tray suitable for Refrigerator of any make and capacity including taking down of defective chiller tray complete all as specified and directed. . |
| 69 | S&F Compressor suitable for Deep freezer including taking down of defective compressor complete all as specified and directed. |
| 70 | S&F in repair CondensorMotor suitable for Deep freezer of any make and capacity including taking down of defective condenser complete all as specified and directed. |
| 71 | S&FFan Blade for deep freezer including taking down of defective blade complete all as specified and directed |
| 72 | S&F in repair PCB Kit Refrigerator/ Deepfreezer etc after recitfication of PCB the same to be fix properly including making working condition complete all as specified and directed. |
| 73 | Comprehensive maintenance of AC/water cooler, Refrigertor & Deepfreezer, etcand repair including checking all parts and renewal / replacement of minor defective parts, Servicing and checking offan motor,Compressor Oil Charging, Suction,liquid Line, nitile rubber,Insulation, Insulation Tape Wrapping with tie, Drier Change, Gas Charging complete all as specified and directed. |
| 74 | S&F in repair Geyser of 25/35 Ltr capacity of any type from exiting position, tank leaking, shyphon checking etc, if required minor repair like brazing, etc complete all specifiedand refixing to its existing location or new location with testingfor its proper functioning complete all as specified and directed. |
| 75 | M&L for Heat pillar any type 1500W high efficiency heating device with a chrome plated outer body and voltage of 220-230 V AC 50 Hz including 2 heating rod and oscillation speed of 5 to 8 pm, complete all as specifed and directed |
| 76 | M&L for Geyser 25 Ltr capacity, 1500W high efficiency heating device voltage of 220-230 V AC 50 Hz includingcomplete all as specifed and directed |
| 77 | S&F in repair Heat pillar any capacity of any type from exiting position,checking all electical connections, heating rod oscilation fan, etc, if required minor repair like brazing, etc complete all specifiedand proper functioning complete all as specified and directed.Note : Spares required then supplied and measured separately under relevant item. |
| 78 | S&F in repair heating rod 2 Nos suitable for heat pillar as existing type complete all as specified and directed.. |
| 79 | S&F in repair Oscilation fan with motor suitable for heat pillar as existing type complete all as specified and directed.. |
| 80 | S&F in repair switch unit 3 Nos suitable for heat pillar as existing type complete all as specified and directed.. |
| 81 | S&F in repair Body with base plate including guard suitable for heat pillar as existing type complete all as specified and directed.. |
| 82 | M&L for writing MES/ SM No on E/M machinery size of 12 cm height character/ numbers with black/ white paint complete all as specifed and directed. |
| 83 | M&L for for writing MES/ SM No on E/M machinery size of 12 cm height commas, colan, slash and specaial characters etc with black/ white paint complete all as specifed and directed. |