}

Design, Fabrication, Supply, Installation, Testing And Commissioning Of Energy Conservation System Along With Fire Safety Equipments At Bmc Schools In City, Western And Eastern Area (Group I, Ii, Iii)., Mumbai-Maharashtra

Local Bodies has published Design, Fabrication, Supply, Installation, Testing And Commissioning Of Energy Conservation System Along With Fire Safety Equipments At Bmc Schools In City, Western And Eastern Area (Group I, Ii, Iii).. Submission Date for this Tender is 05-11-2024. Cleaning and Disinfecting Solutions Tenders in Mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

45757521
Corrigendum : Design, Fabrication, Supply, Installation, Testing And Commissioning Of Energy Conservation System Along With Fire Safety Equipments At Bmc Schools In City, Western And Eastern Area (Group I, Ii, Iii).
Open Tender
Indian
Maharashtra
Mumbai
05-11-2024

Tender Documents

Tender Details

Design, Fabrication, Supply, Installation, Testing And Commissioning Of Energy Conservation System Along With Fire Safety Equipments At Bmc Schools In City, Western And Eastern Area (Group I, Ii, Iii).- 1 G-I Supply, Delivery, Installation and Commissioning of 550Wp 144Cells Framed Dual Glass Mono PERC Bifacial Solar ModuleHighest Reliability & Enhanced Crack tolerantModule Utilizing Half Cut cell for Optimum PerformanceHighest commercial gains, lower LCOE*Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%.Connector IP68 rated / MC4 compatibleSolar Inverter IP65AC&DC Distribution Board 2 G-I SITC of Module mounting structure formodules roof mounted 3 G-I SITC of 4Sqmm X 1 Core Black/Red ATC Cond. LSOH Insulated & Sheathed (120 Deg.C) UV Resistant Solar Cable e -Type 1 4 G-I Refixing of solar panel 5 G-I Removing and transporting to bmcWarehouse 6 G-I Liasioning work formeter 7 G-I SITC of LED type 40WSolar light fixtures withSENSOR PIR & INTELLIGENT inbuilt battery. 8 G-I SITC of Clean agent fire extinguisher 9 G-I SITC ofPVC Trunking with cover & all other accessories – 100 x 50mm (W x H) - PVC Trunking with cover and partition 10 G-I SITC of1 st category Al armoured cables FRLS outer sheathed- 3.5C x 70 Sq.mm 11 G-I SITC of Cable End Termination For Copper Cables – 2C x 4 Sq.mm 12 G-I SITC of Cable End Termination For Aluminium Cables – 3.5C x 70 Sq.mm 13 G-I SITC ofG.I. Cable tray with all other accessories 100 x 25mm (W x H) - (16 SWG - 1.6mm) without cover 14 G-I Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D. 15 G-I S.I.T.C of maintenance free earthing comprising 17.2 mm electrode 16 G-I SITC of Earthing Continuity Conductors -25 x 6mm GI 17 G-I SITC of Class B+C/Type I+II Surge Protection Devices For Switching Surge & Lightning Surge, For Handling 10/350 & 8/20 Microsecond Waveform For : Three Phase & neutral Application MODEL : V25-B+C/3+NPE-320V 18 G-I SITC of Auto glow signagein case of Fire etc. 19 G-I CSMC for 3rd Year 20 G-I CSMC for 4th Year 21 G-I CSMC for 5th Year 22 G-II Supply, Delivery, Installation and Commissioning of 550Wp 144Cells Framed Dual Glass Mono PERC Bifacial Solar ModuleHighest Reliability & Enhanced Crack tolerantModule Utilizing Half Cut cell for Optimum PerformanceHighest commercial gains, lower LCOE*Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%.Connector IP68 rated / MC4 compatibleSolar Inverter IP65AC&DC Distribution Board 23 G-II SITC of Module mounting structure formodules roof mounted 24 G-II SITC of 4Sqmm X 1 Core Black/Red ATC Cond. LSOH Insulated & Sheathed (120 Deg.C) UV Resistant Solar Cable e -Type 1 25 G-II Refixing of solar panel 26 G-II Removing and transporting to bmcWarehouse 27 G-II Liasioning work formeter 28 G-II SITC of LED type 40WSolar light fixtures withSENSOR PIR & INTELLIGENT inbuilt battery. 29 G-II SITC of Clean agent fire extinguisher 30 G-II SITC ofPVC Trunking with cover & all other accessories – 100 x 50mm (W x H) - PVC Trunking with cover and partition 31 G-II SITC of1 st category Al armoured cables FRLS outer sheathed- 3.5C x 70 Sq.mm 32 G-II SITC of Cable End Termination For Copper Cables – 2C x 4 Sq.mm 33 G-II SITC of Cable End Termination For Aluminium Cables – 3.5C x 70 Sq.mm 34 G-II SITC ofG.I. Cable tray with all other accessories 100 x 25mm (W x H) - (16 SWG - 1.6mm) without cover 35 G-II Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D. 36 G-II S.I.T.C of maintenance free earthing comprising 17.2 mm electrode 37 G-II SITC of Earthing Continuity Conductors -25 x 6mm GI 38 G-II SITC of Class B+C/Type I+II Surge Protection Devices For Switching Surge & Lightning Surge, For Handling 10/350 & 8/20 Microsecond Waveform For : Three Phase & neutral Application MODEL : V25-B+C/3+NPE-320V 39 G-II SITC of Auto glow signagein case of Fire etc. 40 G-II CSMC for 3rd Year 41 G-II CSMC for 4th Year 42 G-II CSMC for 5th Year 43 G-III Supply, Delivery, Installation and Commissioning of 550Wp 144Cells Framed Dual Glass Mono PERC Bifacial Solar ModuleHighest Reliability & Enhanced Crack tolerantModule Utilizing Half Cut cell for Optimum PerformanceHighest commercial gains, lower LCOE*Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%.Connector IP68 rated / MC4 compatibleSolar Inverter IP65AC&DC Distribution Board 44 G-III SITC of Module mounting structure formodules roof mounted 45 G-III SITC of 4Sqmm X 1 Core Black/Red ATC Cond. LSOH Insulated & Sheathed (120 Deg.C) UV Resistant Solar Cable e -Type 1 46 G-III Refixing of solar panel 47 G-III Removing and transporting to bmcWarehouse 48 G-III Liasioning work formeter 49 G-III SITC of LED type 40WSolar light fixtures withSENSOR PIR & INTELLIGENT inbuilt battery. 50 G-III SITC of Clean agent fire extinguisher 51 G-III SITC ofPVC Trunking with cover & all other accessories – 100 x 50mm (W x H) - PVC Trunking with cover and partition 52 G-III SITC of1 st category Al armoured cables FRLS outer sheathed- 3.5C x 70 Sq.mm 53 G-III SITC of Cable End Termination For Copper Cables – 2C x 4 Sq.mm 54 G-III SITC of Cable End Termination For Aluminium Cables – 3.5C x 70 Sq.mm 55 G-III SITC ofG.I. Cable tray with all other accessories 100 x 25mm (W x H) - (16 SWG - 1.6mm) without cover 56 G-III Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D. 57 G-III S.I.T.C of maintenance free earthing comprising 17.2 mm electrode 58 G-III SITC of Earthing Continuity Conductors -25 x 6mm GI 59 G-III SITC of Class B+C/Type I+II Surge Protection Devices For Switching Surge & Lightning Surge, For Handling 10/350 & 8/20 Microsecond Waveform For : Three Phase & neutral Application MODEL : V25-B+C/3+NPE-320V 60 G-III SITC of Auto glow signagein case of Fire etc. 61 G-III CSMC for 3rd Year 62 G-III CSMC for 4th Year 63 G-III CSMC for 5th Year

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-10-2024 Corrigendum- I Date 05-11-2024

Key Value

Document Fees
INR 19470 /-
EMD
INR 2016000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail