REPAIR/REPLACEMENT OF PUMPS, MOTORS, STARTERS, CONTROL PANEL, RELAYS, FILTERATION PLANT, RO, SOLAR WATER HEATING SYSTEM AND EXTERNAL WATER SUPPLY, CLEANING OF WATER TANK OF VARIOUS CAPACITY AND MISC CONNCETED ITEMS AT RAMBAN AND BANIHAL AREA UNDER AGE (I) BHALRA; 1 Material and labour for taking out Motor Set of capacity 10 H.P to 20 HP from position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections including necessary nuts, bolts, washers etc., required at site of work, complete all as specified & directedNote : All spares parts required shall be measured and paid for separately as appended below:- 2 (a) Ball Bearing of suitable size 3 (b) Rubber washer of suitable size 4 (c ) Packing sheet of suitable size 5 (d) Bush cover of suitable size 6 (e) Mechanical Seal of suitable size 7 (f) Circlips Clamp of suitable size 8 Material and labour for taking out Motor Set of capacity 5 H.P to 7.5 HP from position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections including necessary nuts, bolts, washers etc., required at site of work, complete all as specified & directedNote : All spares parts required shall be measured and paid for separately as appeded below:- 9 (a) Ball Bearing of suitable size 10 (b) Rubber washer of suitable size 11 (c ) Packing sheet of suitable size 12 (d) Bush cover of suitable size 13 (e) Mechanical Seal of suitable size 14 (f) Circlips Clamp of suitable size 15 Material and labour for taking out Motor Set of capacity 1 H.P to 3 HP Centrifugal/submerisble sewagefrom position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections including necessary nuts, bolts, washers etc., required at site of work, complete all as specified & directedNote : All spares parts required shall be measured and paid for separately as apended here-in-after:- 16 (a) Ball Bearing of suitable size 17 (b) Rubber washer of suitable size 18 (c ) Packing sheet of suitable size 19 (d) Bush cover of suitable size 20 (e) Mechanical Seal of suitable size 21 (f) Circlips Clamp of suitable size 22 Material and labour for rewinding of damaged/burnt motor of capacity 1 H.P to 20 H.P any type by using enamelled copper wire of superior quality of existing grade and same Nos. of turns including varnishing ‘F’ class insulation and drying in heat chamber / oven including all other material / fittings and testing on completion, complete all as specified & directed. 23 Material and labour for taking out Centrifugal Pump of capacity10 HP to 20 H.P and transportation of same from site to workshop and back,dismantling of cable/ pipe connection and reinstallation of pump set after repair on the existing foundation and making electrical connections complete all as specified and directedNote : All spares parts required shall be measured and paid for separatelyas apended below:- 24 (a) Pump overhauling GM bushes ,shaft rematteling making key gland packing,incl all engineering work. 25 (b) Pump shaft stainless steel of same make and model duly grinded/polished 26 (c) Bearing of suitable size of pump 27 (d) Plugging leaks in casing by welding the same incl grinding for smooth surface 28 Material and labour for taking out Centrifugal Pump of capacity1 HP to 7.5 H.P and transportation of same from site to workshop and back,dismantling of cable/ pipe connection and reinstallation of pump set after repair on the existing foundation and making electrical connections complete all as specified and directedNote : All spares parts required shall be measured and paid for separately 29 (a) Pump overhauling GM bushes ,shaft rematteling making key gland packing,incl all engineering work. 30 (b) Pump shaft stainless steel of same make and model duly grinded/polished 31 (c) Bearing of suitable size of pump 32 (d) Plugging leaks in casing by welding the same incl grinding for smooth surface 33 Supply & Fixing in replacement of Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 20-32 Amp having protection against single phase with provn of volt/Amp meter, indicators, selector switches, push ON/OFF switch completeincluding making necessary connections and taking down old unserviceable Starter all as specified and as directed.Make : L&T / Havells / Legrand / ABB / C&S 34 Supply & Fixing in replacement of Star Delta starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 13-22 Amp having protection against single phase with provn of volt/Amp meter, indicators, selector switches, push ON/OFF switch completeincluding making necessary connections and taking down old unserviceable Starter all as specified and as directed.Make : L&T / Havells / Legrand / ABB / C&S 35 Supply & Fixing in replacement of DOL starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 18-25 Amp having protection against single phase with provn of volt/Amp meter, indicators, selector switches, push ON/OFF switch completeincluding making necessary connections and taking down old unserviceable Starter all as specified and as directed.Make : L&T / Havells / Legrand / ABB / C&S 36 Supply & Fixing in replacement of DOL starter fully automatic, 3 phase, 415 volts, 50 Hzheavy duty with overload relay ragne 23-32 Amp having protection against single phase with provn of volt/Amp meter, indicators, selector switches, push ON/OFF switch completeincluding making necessary connections and taking down old unserviceable Starter all as specified and as directed.Make : L&T / Havells / Legrand / ABB / C&S 37 Supply and fixing in replacement of CI Non Return Sluice Valves ISI Marked flanged class 1.6 PN with by-pass arrangement and necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints and testing including taking out old unserceable non returnvalves complete of following sizes :-Make : KIRLOSKAR / BIR / BIV / L&T / KARTAR/ ZOLOTO 38 (a) 150 mm bore 39 (a) 100mm bore 40 (b) 80mm bore 41 Supply and fixing in replacement of CI Sluice Valves ISI Marked flanged class 1.6 PN with necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints and testing including taking out old unserviceable sluice valves complete of following sizes :-Make :KIRLOSKAR / BIR / BIV / L&T / KARTAR/ ZOLOTO 42 (a) 150 mm bore 43 (a) 100 mm bore 44 (b) 80 mm bore 45 Supply and fixing in replacement of Gun metal globe, Ball or gate valve class-2 with iron wheel head screwed both ends for pipes of following sizes complete including taking down old unserviceable gate valves all as specified and directed :- Make :KIRLOSKAR / BIR / BIV / L&T / KARTAR /LEADER / ZOLOTO 46 (a) 80 mm bore 47 (b) 63 mm bore 48 (c) 50mm bore 49 (d) 40 mm bore 50 (e) 32 mm bore 51 (f) 25 mm bore 52 (g) 20 mm bore 53 Supply and fixing in replacement of Cast Iron Foot Valve, conforming to IS-4038, complete suitable for pipes of following sizes complete including taking down old unserviceable foot valve all as specified and directed :-Make :KIRLOSKAR / BIR / BIV / L&T / KARTAR /LEADER / ZOLOTO 54 (a) 80 mm bore 55 (b) 63 mm bore 56 (c) 50 mm bore 57 Excavation in trenches not exceeding 1.5 mtr wide and 1.5 mtr in depth for laying of pipe lines and getting out old pipes in soft/lloose soil all as specified and directed by Engr-in-Charge. 58 Returning and filling in incl spreading, levelling watering and well ramming in layers not exc 25 cm in soft / loose soil, all as specified and directed. 59 Removal of excavated surplus spoil /rocksat a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr from the starting point all as directed. 60 Taking out Mild Steel / Cast Iron / Ductile Iron /Galvaniser Iron water mains including all fittings with spigot and socket ends or flanged ends including lead / tyton joints and burning out lead joints and recovering lead, cleaning the pipe and removing to store for reuse complete all as specified and as directed :-Note : Excavation and earth work shall be measured and paid for separately. 61 (a) 100 mm bore 62 (b) 80 mm bore 63 (c ) 50 mm bre 64 (d) 40 mm bore 65 (e) 25 mm bore 66 (f)20 mm bore 67 Supply and fixing in replacement of Galavised iron tubing (GI), medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminshing pieces, caps, plugs and unions etc., laid in trenches /fixed to walls and ceilings or laid in floors, complete all as specified and as directed of the following description :- Make : JINDAL PIPES / TATA / BST / PRAKASH SURYA 68 (a) 100 mm bore 69 (b) 80 mm bore 70 (c) 50 mm bre 71 (d) 40 mm bore 72 (e)25 mm bore 73 (f) 20 mm bore 74 Material & Labour in replacing Gland for pump set capacity 2 HP to 20 HP complete all as specified and directed by Engr-in-Charge. 75 Supply only High Strength Calcium based granular disinfectant for water treatment, more stable than chlorine gas, and stronger than Bleaching Powder and Sodium Hypochlorite of following specifications :-(a) Chemical analysis & physical observations :Description : Whitish granules ofgranular size (Mesh passing through – 100 BSS) : 1.1 (± 0.1) %, Water / moisture : 5.00 (± 0.2) % Other insoluble Calcium salts: 1.1 (± 0.1) %Mercury and other Heavy Metal contaminants : BDL (The chlorination chemical must contain appropriate quantities of dispersants / corrosion inhibitors to prevent encrustation / scaling in distribution systems)(b) Stability : Projected shelf life of chlorination chemical must be one year with minimal loss of chlorine. Make : Purichlore / Mark Daxter / ALTOCH-Gp (Declivace Technologies Pvt Ltd) / Any E-in-C approved Make 76 Supply only Hypochlorous Acid (HOCL) for chlorination of drinking water disinfection solution having high residual effect, clear colour less and potent germicide non corrosive and non foaming stable up to100° C for drinking water as and when required in HDPE jericanes of 35 Litres capacity having the following features :(a) Potent germicide(b) Slim control(c) High residual effect to avoid contamination(d) Less hazardous(e) Work at low dosage in post disinfection(f) No after taste(g) Most reliable in operation(h) Eco friendly and biodegradableMake : Penta Water Treatment / Seacolor/ Hygene Maddox People Care / Super-Chlor Total 77 Supply only Potassium aluminum sulfate, clear in colour of class 1 quality suitable for purification of raw water all as specified and directed by Engr-in-Charge. 78 Supply only Bleaching powder class 1 qualiity all as specified and directed by Engr-in-Charge. 79 Supply only Lead pig superior quality all as specified and directed by Engr-in-Charge. 80 Supply only Lead wool superior quality all as specified and directed by Engr-in-Charge. 81 Draining out water from RCC overhead water storage tank of capacity 90,000 Ltrs, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes all as specified and directed. 82 Draining out water from sedimentation tank of capacity 80000 Ltrs, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes all as specified and directed. 83 Draining out water from Mild Steel water storage tank or RCC Tankof capacity 50000 / 60000 Ltrs, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes all as specified and directed. 84 Draining out water from underground water storage tank of capacity 45000 Ltrs, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose,removing all scale,dirt,algae,vegetation if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes all as specified and directed. 85 Draining out water from clear water tank of capacity 40000 Ltrs, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes all as specified and directed. 86 Draining out water from underground/ semi underground water storage tank of capacity 30000 Ltrs, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes all as specified and directed. 87 Draining out water from PVC water storage tank of capacity 10000 Ltrs, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing aftercleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes all as specified and directed. 88 Draining out water from PVC water tank of capacity 5000 Ltrs, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes all as specified and directed. 89 Draining out water from PVC overhead water tank of capacity ranging from 250 Ltrs to 500 Ltrs placed at different locations at Ramban, Banihal & Patnitop, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing after cleaning with water, cleaning walls and floors by scratching with wire brushes all as specified and directed. 90 Draining out water from PVC overhead water tank of capacity ranging from 1000 Ltrs placed at different locations at Ramban, Banihal & Patnitop, taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation if any and flushing after cleaning with water, cleaning walls and floors by scratching with wire brushes all as specified and directed.Note for Serial Item No 28 to 36 :1. The Date of Cleaning and Due on shall be written with synthetic enamel paint prominently on the tanks cleaned all as directed by the Engr-in-Charge. The quoted rate shall be deemed to be inclusive of this aspect.2. The T&P required for cleaning of the tanks is deemed to be included in the unit rate quoted by the contractor. 91 Taking out old unserviceable filter media from existing gravity type filter, cleaning the filter thoroughly from inside, outside and channel all around, taking out sludge and throwing the same in low lying area including replacing filter media with new filter media all as specified and directed by Engineer-in-Charge. NOTE :-- Supply only new filter media shall be measured & paidfor separately as under :- Supply only filter media of size as mentioned below :- 92 a) Course aggregate of size 63mm 93 b) Course aggregate of size 40mm 94 c) Course aggregate of size 20mm 95 d) Course aggregate of size 12.5mm 96 e) Course sand suitable for filter plant 97 Repair/servicing ofchemical dosingelectric operated of make Renuka Tech Model RWT-DLX-0003, at site with the replacement of following unserviceable spares installed at water supply installation.Note : All spares parts required shall be measured and paid for separately as supply only under following items of Sch ‘A’ 98 (a) Supply only non return valve of suitable size complete all as specified. 99 (b) Supply only complete set of inlet and outlet pipe for chemical dosing pump complete all as specified. 100 (c ) Supply only foot valve with strainer, 75 mm long complete all as specified 101 (d) Supply only regulator with marking from 1 to 10 to control discharge of HOCL complete all as specified. 102 Repairs/Replacement of PLC controlled unit with control panel for Sewage Treatment Plant with all electrical circuits, contactors driven by micro controller based programmable logic controller system, totally enclosed containing all necessary motor starters, circuit breakers, indicating lights, selector swtiches, relays, terminal blocks, controls and isolators complete and replacement of the following defective over load relay contactors in all respects all as specified and by Engineer-in-Charge :-(a) 3 pole contactor AC operated of capacity 12 Amp, 5.5hP, 5.5 KW rating 415 V - 01 NosMake : ABB, Product code No A-12-30-10(b) 3 pole contactor AC operated of capacity 32 Amp, 20hP, 15 KW rating 415 V - 01NosMake : ABB, Product code No A-30-30-01 103 Submersible flat cable PVC insulated and PVC sheathed LT 1100 volts grade with copper conductor of size 10 Sqmm 3 Core, complete all as specified and directed.Make : Havells / Finolex / Polycab / Plaza / Asian 104 Submersible flat cable PVC insulated and PVC sheathed LT 1100 volts grade with copper conductor of size 16 Sqmm 3 Core, complete all as specified and directed. Make : Havells / Finolex / Polycab / Plaza / Asian 105 Supply only PVC Flexible pipe of size 63mm as complete as specified and as directed by the Engr-in-Charge 106 Replacement of ON LOAD change over switch 415 volt sheet metal enclosure 4 pole of capacity 100 Amp, complete all as specified and directed. 107 Replacement of ON LOAD change over switch 415 volt sheet metal enclosure 4 pole of capacity 200 Amp, complete all as specified and directed. 108 Dismantling and refixing the complete unit of new solar water heater Plate(set of 4) of capacity 300 LPD installed at various sites completeall serviceableaccessories including repairing/replacing all defective parts such as water tank, nuts, bolts, washers, drain plug, cleaning tanks, defective tubesand all other minor accessories as required at site including painting the solar water heater water tank by rubbing the old paint and applying with two coats of synthetic enameled paint by spray painting where necessary and testing the same after repair all as specified and directed by Engineer-in Charge. 109 Dismantling and refixing the complete unit of new solar water heater Plate(set of 4) of capacity 500 LPD installed at various sites completeall serviceableaccessories including repairing/replacing all defective parts such as water tank, nuts, bolts, washers, drain plug, cleaning tanks, defective tubesand all other minor accessories as required at site including painting the solar water heater water tank by rubbing the old paint and applying with two coats of synthetic enameled paint by spray painting where necessary and testing the same after repair all as specified and directed by Engineer-in Charge. 110 Dismantling and refixing the complete unit with new solar heating plates (set 0f 10) system 1000LPD capacityincluding , drain plug, cleaning tanks, defective tubes and painting with two coats of synthetic enamelled paint by spray painting heat collector copper strips and cleaning the collector tank complete system including testing the same after repair all as specified and directed byEngineer-in Charge. 111 Supply & fixing the following items/spares in replacement for solar heaters of various capacities as mentioned in 45, 46 & 47here-in-before all as specified :- 112 (a) Heating element of capacity upto 2 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½”complete all as specified. 113 (b) Heating element of capacity upto 1.5 KW (Electric rod) having rubber washer of size 1 ¼” or 1 ½”complete all as specified. 114 (c) Glycol (Anti freezing solution) for filling in copper tubes complete all as specified. 115 (d) Dead flange with nut, bolts and washers complete all as specified. 116 (e)Float valve assembly 15mm dia complete all as specified. 117 (f) Thermostat suitable for solar heater complete all as specified 118 (g) Hot water steel tanknon stick 2mm thick with ceramic lining of capacity 300 Ltrs each including making necessary connections complete all as specified. Make : Surya Shakti / TATA BP or equivalent. 119 (h)Hot water steel tanknon stick 2mm thick with ceramic lining of capacity 1000 Ltrs each including making necessary connectionscomplete all as specified Make : Surya /Shakti, TATA BP or equivalent. 120 Supply and fixing GI Socekt ofHavey grade with and including jointing meterial and taking out old unserviceable socket complete all as specified and directed of following sizes :- Make : Make : Jindal / TATA / Prakash Tubes 121 (a)50 mm bore 122 (b)40 mm bore 123 (c)25 mm bore 124 (d) 20 mm bore 125 (e)15 mm bore 126 Supply and fixing GI Elbow ofHavey grade with and including jointing meterial and taking out old unserviceable Elbow complete all as specified and directed of following sizes :- Make : Make : Jindal / TATA / Prakash Tubes 127 (a)50 mm bore 128 (b)40 mm bore 129 (c)25 mm bore 130 (d) 20 mm bore 131 (e)15 mm bore 132 Supply and fixing GI Union ofHavey grade with and including jointing meterial and taking out old unserviceable Union complete all as specified and directed of following sizes :- Make : Make : Jindal / TATA / Prakash Tubes 133 (a)50 mm bore 134 (b)40 mm bore 135 (c)25 mm bore 136 (d) 20 mm bore 137 (e)15 mm bore 138 Repairs of LT panel with electrical circuits, contactorscontaining all necessary motor starters - 02 Nos, circuit breakers, indicating lights, selector swtiches, relays, terminal blocks, controls and isolators complete and replacement of the following defective over load relay contactors in all respects all as specified and by Engineer-in-Charge.All spares parts required shall be measured and paid for separately 139 (a) 3 pole contactor for star Delta connection, AC operated suitable for 20-32 amp range, 415 VMake : L&T, Havells, ABB, C&S 140 (b) 3 pole contactor for star Delta connection, AC operated suitable for 12-18 amp range, 415 V Make : L&T, Havells, ABB, C&S 141 (c) Thermal overload relay suitable for 12-32 Amp contactor range, 415VMake : L&T, Havells, ABB, C&S 142 (d) Single Phase preventer suitable for 5HP to 15 HP MotorMake : L&T, Havells, ABB, C&S 143 Replacement of MCCB 200 Amps 4 Pole 36 KA, Fixed Thermal and fixed magnetic setting fixed in existing panel and connected to told existing cable including necessary fixing arrangement lugs, glan etc complete including takiing down old all as specified and as directed. Make : Havells/Standard/ABB/Havells 144 Replacement of MCCB 160 Amps 4 Pole 36 KA, Fixed Thermal and fixed magnetic setting fixed in existing panel and connected to told existing cable including necessary fixing arrangement lugs, glan etc complete including takiing down old all as specified and as directed. Make : Havells/Standard/ABB/Havells 145 Replacement of MCCB 100 Amps 4 Pole 16 KA, Fixed Thermal and fixed magnetic setting fixed in existing panel and connected to told existing cable including necessary fixing arrangement lugs, glan etc complete including takiing down old all as specified and as directed. Make : Havells/Standard/ABB/Havells 146 Replacement of MCCB 63 Amps 4 Pole 16 KA, Fixed Thermal and fixed magnetic setting fixed in existing panel and connected to told existing cable including necessary fixing arrangement lugs, glan etc complete including takiing down old all as specified and as directed. Make : Havells/Standard/ABB/Havells 147 Supply & Fixing MCB SPN 40 Amps C series 240V 50Hz 10 KA suitable for lighting and other domestic loads complete including taking down all as specified and directed by Engr-in-charge. Make : C&S, Havells, Indoasian, ABB 148 Supply & Fixing MCB TPN 63 Amps C series 415V 50Hz 10 KA suitable for lighting and other domestic loads including taking downall as specified and directed by Engr-in-charge. 149 Material & Labour in replacementfor Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick burried in a pit to a depth of 2.25mtrs below ground level with top edge of earth plate at a depth of not less than 1.50 meters below ground level, earth plate packed on all sides with charcol dust mixed with salt to a thickness of 15cm,.Connected with earthing lead of 32mmx6mm strip galvanised iron, watering pipe 20mm dia light grade and water filling funnel and mess complete all as shown in plate No 4 of MES schedule part II to the earthing test point, Including PCC Work complete all as specified and as directed by the Engr-in Charge. 150 Cutting the CI/DI pipes and reducing the required length before laying for inserting of new CI specials such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc complete for the following:- Note :- CI specials and earth work will be measured and paid for seperately. 151 (a) 100 mm bore 152 Specials of Ductile iron / Cast Iron fittings for spigot and socket / flanged pipe such as bends (any type radius and angle) tapers any type (straight, bends) tee, joint piece single branch, Y junction, double branch, cross (all socket or socket and spigot or all flanged ends) collar, caps and plug, connecting piece one end flanged and other socketed or spigot and bell mouth complete of the following sizes all as specified and as directed. 1. The fittings shall be as per IS1538-19892. The joints shall be measured and paid separately. 153 (a) upto 150 mm bore