}

Annual Plan-Electrification Of G.J.B School Mathikunnu At Puthur Grama Panchayat -S0 245/24-General Electrical Work, puthur-Kerala

Local Bodies has published Annual Plan-Electrification Of G.J.B School Mathikunnu At Puthur Grama Panchayat -S0 245/24-General Electrical Work. Submission Date for this Tender is 18-10-2024. Storage Chests and Cabinets and Trunks Tenders in puthur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

45705425
Annual Plan-Electrification Of G.J.B School Mathikunnu At Puthur Grama Panchayat -S0 245/24-General Electrical Work
Open Tender
Indian
Kerala
Puthur
18-10-2024

Tender Documents

Tender Details

Annual Plan-Electrification of G.J.B School Mathikunnu at Puthur Grama Panchayat -S0 245/24-General Electrical Work , Electrical , 90.2.2.1:Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Db'S Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point With 6A, Plate Ceiling Rose - Short Point , 90.2.2.4:Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Db'S Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point , 90.2.2.6:Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Db'S Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A Switch In The Same Switch Board As That Of Light Points. , 90.2.2.7:Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providingswitch Boardmain And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Db'S Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Independent Plug - Short Point , 90.3.18.2:Supply, Fabrication, Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size, Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer, Making Good The Damages, Colour Washing Etc As Required.32 Mm Dia With Hg Company Fabricated Clamps , 90.15.4.1:Supply Conveyance, Installation, Testing And Commissioning Of 20W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing,Acrylic Cover Complete With Thd Less Than10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 90.15.4.2:Supply Conveyance, Installation, Testing And Commissioning Of 36/40W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing,Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 90.3.20.3:Supply & Installation Of Light Fittings On Tw Round Block ≪Br≫ Supply, Conveyance Installation Testing And Commissioning The Light Fittings Of Following Types Made Of Crca With 0.5Mm Thicknesscomplete With All Accessories Andlamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.1200 Mm 1X20w Led Lamp With Box Type Fixture , 90.3.21.3:Supply & Installation Of Light Fittings On 'C/U' Shaped Flat Iron Bracket ≪Br≫ Supply, Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From 0.5Mm Crca Sheet Complete With All Accessories Andlamps Etc. Directly On Wall Using 2 Nos. 'C/U' Brackets Made From 20 X 3 Mm Ms Flat, Painting The Flat Iron Bracket And Giving Connections With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss Or Extending The Original Wiring And Giving Connection Etc. As Required.1200 Mm 1X20w Led Lamp With Box Type Fixture , 90.4.1:Supply And Installation Of Suitable Size Ms Rod Type Fan Clamp In The Rcc Slab As Per Is 732 As Required. , 90.4.5.4:Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply , 1.47:Supplying And Fixing Extra Down Rod Of 10 Cm Length G.I. Pipe, 15 Mm Dia, Heavy Gauge Including Painting Etc. As Required. (Note: More Than 5 Cm Length Shall Be Rounded To The Nearest 10 Cm And 5 Cm Or Less Shall Be Ignored) , 90.6.10.1:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 90.6.10.2:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required25 Mm , 1.17.2:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 1.5 Sq. Mm , 90.6.4.2:Supply And Drawing 650/1100 V Grade Frls Pvc Insulated Stranded Single Core Copper Conductor Cables Conforming To Is 694 Part I 1990 In The Existing Surface / Recess Conduit As Required Including Giving Necessary Connections Of The Following Sizes.1.00 Sq.Mm 2 Run , 90.9.1.1:Supply And Fixing 50 X 50 Mm Pvc Cable Management System With Base And Lid Along With The Following Accessories Conforming To Iec 61084/ Bs 476 & 4678 On Surface / Recessincluding Cutting The Wall And Making Good The Damages In Case Of Recessed Installation As Required.50X50mm Cable Management System With Base And Lid , 90.9.1.7:Supply And Fixing 50 X 50 Mm Pvc Cable Management System With Base And Lid Along With The Following Accessories Conforming To Iec 61084/ Bs 476 & 4678 On Surface / Recessincluding Cutting The Wall And Making Good The Damages In Case Of Recessed Installation As Required.End Cap , 1.27.1:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , 1.27.2:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.27.4:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.6 Module (200Mmx75mm) , 1.24.1:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amps Switch , 1.24.4:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Amp Socket Outlet , 90.11.1.14:Supply And Installation Ofsheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , 2.3.3:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcbirccb/Isolator12 Way, Double Door , 2.13.1:Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.10.1:Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, &Quot;C&Quot; Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , 2.14.2:Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.15.2:Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 90.12.5.40:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required.4 Core 10 Sq Mm , 90.12.7.40:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 10 Sq Mm With Factory Made Clamp , 90.12.9.2:Supplying, Laying And Jointing Of The Following Sizes Of Double Wall Corrugated (Dwc) Pipes Made Out Of Hdpe Conforming To Is 14930 Part Ii For Mechanical Protection To Underground Power Cables With All Required Accessories In Ground In The Existing Trench50/38 Mm Or Nearest Size , 9.1.32:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm (25Mm) , Od403493/2023-2024:Supplying And Providing Copper Earth Clamps For Cable Glands For The Following Sizes Ofcables As Required.4 Sq Mm -16 Sq Mm With12 Mm Wide X 1 Mm Thick Clip , 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Od403344/2023-2024:Providing And Fixing Test Joint On Watering Pipe, Made Of 2 No. Strips As Mentioned Below Of The Following Sizes Provided On Either Side Of The Conductors With 4 Nos Of Gi Bolts, Nuts Check Nuts And Spring Washers Etc. Complete As Required.2Nos25x6 Mmg.I. Strip 200 Mm Long , 5.15:Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , 90.16.1.1:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , 90.16.1.2:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.65 Mm Copper Conductor (12 Swg) , 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.5.1:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.00 Mm (14 Swg) , 90.16.5.2:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.2.65 Mm (12 Swg) , 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , Od403356/2023-2024:Supply And Providing The Following Sizes Of Bolt And Nut With Washers On The Existing Ms Box/Earth Bus Etc. As Required Including Necessary Holes As Required. 12X3mm Brass Nut And Bolt , Od403357/2023-2024:Supply And Providing The Following Sizes Of Bolt And Nut With Washers On The Existing Ms Box/Earth Bus Etc. As Required Including Necessary Holes As Required. 25X6mm Brass Nut And Bolt , Od403358/2023-2024:Supply And Providing The Following Sizes Of Bolt And Nut With Washers On The Existing Ms Box/Earth Bus Etc. As Required Including Necessary Holes As Required. 25X3mm Brass Nut And Bolt , Od403355/2023-2024:Preparing Completion And Test Certificates For Kseb Connection

Key Value

Document Fees
INR 555 /-
EMD
INR 6122.0 /-
Tender Value
INR 2.44 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail