| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-10-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 06-11-2024 |
| 2 | 19-10-2024 | Corrigendum No. 01 | BOQ | 30-10-2024 |
| Sl. No. | Item Description |
| 1 | Surface dressing n exc 15 cm deep complete all as specified and directed. |
| 2 | Excavation in post holes (or similar holes) each n. exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed. |
| 3 | Excavating over areas, n exc 1.5 m deep and getting out in Soft Loose soil complete all as specified and directed. |
| 4 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes, pier holes, etc. but not exceeding 10 Sqm on planand getting out insoft/ loosesoil complete all as specified and directed. |
| 5 | Excavation in trenches in any type of soil not exceeding1.5 meter wide and not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out complete all as specified and directed. |
| 6 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but n. exc 3.00 m in depth; for foundations etc. or for shafts, well cess pits, manholes, pier holes, etc. but not exceeding 10 Sqm on planand getting out insoft/ loosesoil complete all as specified and directed. |
| 7 | Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in any type soil complete all as specified and directed. |
| 8 | Removing surplus soil obtained from excavation to a distanceexceeding 50 metre but n. exc 250 mand depositing where directed at a level not exceeding 1.5 metre above the starting paint complete all as specified and directed. |
| 9 | Removing excavated material n exc 50m and depositing where directed at a level nexc 1.5m above the starting point with soil complete all as specified and directed. |
| 10 | M&L for hard core of broken stone of gauge not exceeding 63 mm, deposited, spread & levelled in layers not exceeding 15 cm thick watered and rammed to a true surfaces complete all as specified and directed. |
| 11 | M&L for Moorum red bajri filling in floor or paving laid in layers n. exc. 15cm thick spread levelled and rammed including watering complete all as specified and directed. |
| 12 | M&L for sand cushioning with a layer of sand 80mm thickbefore laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed.Note: Punned thicknes of sand shallbe measured for payment purpose. |
| 13 | Demolition of cement concrete in ground floors and pavings n exc 15cm below or above ground floor complete all as specified and directed. |
| 14 | M&L for Plain cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations / mass concrete complete all as specified and directed. |
| 15 | M&L for providing PCC 1:3:6 type C2 using (40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 16 | M&L for PCC (1:2:4) Type B-0 using 12.5 mm graded stone aggregate as levelling course/mass concrete complete all as specified and directed. |
| 17 | M&L for cement concrete ( 1:2:4) type B-1 (20mm graded agrregate) in lintels upto 1.5m clear span, cills, stes, seimic and other similar bands, plinth course, string course, lacing cours, arapets and railingsupto 60cm in height, coping, kneelers, apex stones, bed plates, kerbs, water througs and the like including wheathering slightly rounded or chamfered angle and throating complete all as specified and directed. |
| 18 | M&L for providing cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) in surfaces channels drains and benching including form work and finishing fair and smooth using extra cement complete all as specified and directed. |
| 19 | M&L for precast cement concrete (1:2:4) type B1 (using 20mm graded stone agg) as in cover slabs for man holes and set in CM 1:4 including necessary form work complete all as specified and directed.Note: Reinforcement shall be measured and paid separately |
| 20 | M&L forPCC (1:3:6) type C2, (using40mm graded stone aggregate) as in plinth protection, 75 mm thick, finishing the surface even and smooth w/o using extra cement including forming & filling expensionjoints 65 mm deep x 10 mm wide filled with sealing compound grade A complete all as specified and directed. |
| 21 | Dismantling ofTrellis work (Jafri), including taking as under of battens in trellis complete all as specified and directed. |
| 22 | M& L for RCC type B1 1:1.5:3 (20mm Graded stone aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed. |
| 23 | M&L RCC (1:2:4) (20 mm graded stone aggregate) as in foundation , raft, footing, plinth beam, base for column etc (Nominal Mix) complete all as specified and directed. |
| 24 | M&L RCC (1:2:4) (20 mm graded stone aggregate) as in column (Nominal Mix) complete all as specified and directed. |
| 25 | M&L forreinforced cement concrete Design mix M-25 (using 20 mm graded stone aggregate ) as in foundations, including rafts, footings, foundation beams, plinth beams, base for coloumnsand mass concreteetc complete all as specified and directed. |
| 26 | M&L forreinforced cement concrete Design mix M-25(using 20 mm graded stone aggregate ) as incoloumns, pillars, piers , posts and struts etc complete all as specified and directed. |
| 27 | M&L forreinforced cement concrete Design mix M-25 (using 20 mm graded stone aggregate ) as in beams , cantilevers bressummers , lintel over 1.5 m span etc. complete all as specified and directed. |
| 28 | M&L forreinforced cement concrete Design mix M-25(using 20 mm graded stone aggregate ) as in slab supported on walls ,beams, coumnns in floor , roof , landing complete all as specified and directed. |
| 29 | M&L forreinforced cement concrete Design mix M-25(using 20 mm graded stone aggregate ) asin Chajjas complete all as specified and directed. |
| 30 | M&L for use and waste formworkto sides of concrete foundation , footing, base of coulmn , raft, raft beam sides and soffits of foundationand plinth beam for rough finishedsurfaces of concretecomplete all as specified and directed |
| 31 | M&L use and waste formwork to soffits of suspended slabs such as roof slabs , floor slabs , landings and similar works , not exceeding 200 mm thick (horizontal or sloping ) including slab edges for rough finishedsurfaces of concretecomplete all as specified and directed |
| 32 | M&L use and waste formwork for to sides of pillar ,post ,struts ,pier column rough finishedsurfaces of concrete rough finishedsurfaces of concretecomplete all as specified and directed |
| 33 | M&L for use and waste Formwork to sides & soffits of floor or roof beam rough finishedsurfaces of concretecomplete all as specified and directed. |
| 34 | M&L for Use and waste Formwork to chajjas including edges for rough finishedsurfaces of concretecomplete all as specified and directed |
| 35 | M&Lfor mild steel TMT bars ,10mm dia and over, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 36 | M&Lfor mild steel TMT bars ,6 mmto 8 mm diaover, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 37 | M&Lfor mild steel TMT bars 5 mmand overuptoand including 10 mm dia , as in stirrups , spacers ,and binders, cut to length bent to shape required including cranking bending spirally for hoping for coloumns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 38 | Demolition of brick work or stone/boulder masonry, built in cement mortar mortor incl all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles completeall as specified and directed. |
| 39 | M&L for rubble random rubble uncoursed, well bounded, bedded and solidly hearted built in cement mortar 1:6 completeall as specified and directed. |
| 40 | M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) completeall as specified and directed. |
| 41 | M&L for 15 mm thick rendering in cement mortaron fair faces of brick work or concrete surfaces , applied in two layers ie. Ist layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd ( top ) layer of 5 mm thick rendering in cement mortar (1:4 ) and top layer mixed with and including water proofing compound @ 3% of wt of cement as per manufacturer\"s instruction & finished even and smooth without using extra cement completeall as specified and directed. |
| 42 | M&Lfor rendering 10 mm thickin CM (1:6) on fair faces of brick work or conrete surfaces/stone masonaryand finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 43 | M&Lfor rendering 15 mm thick on fair faces of brick work or Concrete surfaces in CM (1:4 ) Finishing the surface fair and even complete |
| 44 | M&L rendering 15 mm thick on surface other than fair face of brickwork/stone work with CM 1:4 finished even & fair complete all as specified and as directed |
| 45 | M&L for rendering 5 mm thick in Cement Mortar (1:4) on ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 46 | M&L rendering 10mm thick in cement mortar 1:4 mixed with water proofing compound applied over roof slab complete all as specified and directed.Note: WPC shall be measured and paid seperatly. |
| 47 | Supply only Liquid water proofing compound complete. |
| 48 | M&L for provn of water proofing roof treatment toRCC roof with approved modified membrane of weighing not less than 3kg/sqm and thickness not less than 3mm comprising with following items and all as specified.(i)The surface of roof,parpet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting.For cast iron drain outlets a groove shall be cut as specified and directed.(ii)Oil based Bitumenprimer conforming to IS-3384-1986 @ 0.3 kgs per sqm to be applied on prepared surface till the surface is properly impregnated. (iii)Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm(iv)Laying of water proofing treatment of weight not less than 3 Kg / sqm and thickness not less than 3mmAPP modified polymeric water proofing membrane composed of 100 micron (±10% ) high density polyethylene sheet ( HMHDPE) as center core, which is standwiched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps 75 mm and 100 mm as per manufacture instruction etc.(v) Applyingone coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqmover the membrane. (vi).Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces complete all as specified and directedat site . |
| 49 | S&F Rolled sectionsor Hollowtubes/Angleas in main and cross beams, hip and jack rafters, Posts,purlins where connected to common raftersfixedd with angle cleats or other connecting plates (Fe 290 Gde E 165) complete all as specified and directed. |
| 50 | S&F framed work (ornamental) as in steel gate of angle or other section with gusset plate ,rails braces etc completedrilled for fixing of steel sheeting or other covering door etc to be prepared for hanging or sliding with and including either hook and hinges and also fastening and fixing complete. of Fe -290(Gde E-165) complete all as specified and directed |
| 51 | S&F framed work such as grills gratings,sunshed cover fixed with nut bolts incl,cutting drilling holesetc., with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed baluster, walk ways, railings, framedwork or water tanks and similar work conforming to Fe 290gde E 165 complete all as specified and directed. |
| 52 | M &L for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed. |
| 53 | MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 54 | MS Flats for supports or stays for chain link fencing and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 55 | S&F Mild steel round bars 10mm dia and over as in strengthening bars for bending cranking spirallt for hooking for chain link, hooking end and welding with flats of chain link fencingFE-290 (Gde E-165) complete all as specified and directed. |
| 56 | S & F mild steel screw bolts (machine made) with hexagonal or Square heads at one end and screwed the other or screwed both nds, each screwed end to be fitted with washers and one hexagonal or Square nut, length of boltexc. 5 cm n exc 10 cm, complete all as specified. |
| 57 | S&F chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed by Engineer-in-charge.Note: Weight of chain link fencing will be ascertain by BOO. |
| 58 | S&F pre-painted galvatume aluminium zinc coating AZ-150+ GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and directed |
| 59 | S & FPre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified |
| 60 | Demolition of stone sett paving of any description or thickness laid, bedded and pointed in any mortar complete all as specified and directed. |
| 61 | M&L non skidceramic Coloured tiles, 300mmx300mmx7mm thick, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the colour of tiles, over and including 15 mm thick screed bed or bedding layer of cement mortar 1:6complete all as specified and directed. |
| 62 | M&L for digital glazed ceramic tiles, coloured tiles 300mm x 600mm x 7 to 8 mm thickon vertical faces ie. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 10 mm thick backing coat in cement mortar (1:3) completeall as specified and directed. |
| 63 | M&L for digital glazed ceramic tiles, coloured tiles 300mm x 450mm x 7mm thickon vertical faces ie. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 15 mm thick backing coat in cement mortar (1:4)completeall as specified and directed. |
| 64 | M&L for machine cut Kota stone slab 18 mm to 20 mm thick , as in flooring,laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:3 ) complete all as specified and directed. |
| 65 | M&L Granite slab18mm to 20mm thick machine cut, bedded and joined with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing type as incill and jamb/skirting, steps includigng rounding off the exposed edges completeall as specified and directed. |
| 66 | M&L for18-20 mm thick Graniteof any shade( table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and like including rendering 10mm thick in cement mortar (1:4)including pointing in whitecement 1:2 using marble dust with admixture of pigment to match shade of the slabsincl dismantling of old exisitng granite complete all as specified and directed |
| 67 | Supply and fixed 16-18 mm thick Graniteof any shade ( table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and likein cement mortor 1:4including pointing in whitecement 1:2 using marble dust with admixture of pigment to match shade of the slabs etc completeall as specified and directed. |
| 68 | M& L rounding/ chamferringto edges of stone slabss one edge , such as in steps , cooking plateform and othersimilar situations etc completeall as specified and directed. |
| 69 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade chemically treatedwith aproved colour, design & pattern as in foothpath, parks, lawns, drive ways or light traffic parking etc. of required strenght, thickness & size / shape, , laid in required colour & pattern over and including 30 to 50mm thick uniformly levelled surface ofstone dust cushioning, , filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement completeall as specified and directed. |
| 70 | M & L for coloured designer tiles exterior grade (ENDURA or Equivalent) 10 mm thick, over and including 15 mm thick cement mortor 1:6 set and jointed in floor and pointed in neat cement slurry with grey cement and pigment in floorincl dismantling of old existing tiles or flooring of any description, removing rubbish outside MoD land complete all as specified and directed. |
| 71 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed. |
| 72 | S&F factory made solid PVC moulded door shutterwith wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6mm raised panel design with 5 mm thick moulded PVC sheet on the front face &5mm prelam PVC sheet on back face, supplying & fixing in frame at site complete all as specified and directed. |
| 73 | S&F fixed type ventilators aluminium powder coated of frame size 50.80X 25.40mm,1.5 mm thick half portion will be fixedwith 4mm thick frosted glass and half portion will be fixed with louvers with 4mm thick frosted glass with rubber gasket and aluminium beading ,aluminium wire mess 0.36 mm dia and width of aperture 1.45mm to be fixed over louvers portion onlyincluding necessarycutting holes on wall and fixing arrangements complete all as directed by Engr-in- Charge.Note: (Al. section thickness 1.50 mm } |
| 74 | S&F aluminium windowssliding type three track powder coated consisting of frame bottom with gutter of sizemin 92.34 X 39 mm,sideand top of size min 92.34X29.70, shutters vertical 39X20 mm,shutter top & bottom of size min 20X39 mm ,shutter interlock min size 39X20 mm with rollers and conceled locking arrangements with 4 mm thick tintedglass with rubber gasket, brush and aluminium beading , ,aluminium wire mess 0.36 mm dia and aperture 1.45 mmetcincluding necessarycutting holes on wall and floor and confirming to IS complete all as directed by Engr-in- Charge. Note:(Al. section thickness 1.50 mm } |
| 75 | S&F for 18 mm thickmarine plywood board interior grade with 1mm thickwhite mica lamilation one side and 1mm thick coloured mica on another sideas in cupboard , shelve and shutter etc fixed with screws complete all as specified and directed. |
| 76 | M&L for external teak wood for plywood for external teak wood lipping, 6mm thick, fixed with nails for 18/19mm thick marine plywood boards including preparation and policing complete all as specified and directed. |
| 77 | S&F for aluminium anodised barrel tower bolts of extruded section of 100mm size complete all as specified and directed. |
| 78 | S&F for aluminium anodised barrel tower bolt of 150mmof extruded section complete all as specified and directed. |
| 79 | S&F for continuous (piano) hinges mild steel bright finish or electro galvanised width of width of flaps nexc 30 mm (when open) complete all as specified and directed. |
| 80 | S&F for extruded aluminium alloy handle of 100 mm size fabricatedtype, anodised complete all as specified and directed. |
| 81 | S&F aluminum handles cast type, anodized of 150 mm size complete all as specified and directed. |
| 82 | S&F for Hasp and staple safety type Aluminium anodised with MS hinge pin including bolt to hinge pin of 100 mm size sixed with screw complete all as specified and directed. |
| 83 | S & Fbutt Hinges, medium weight, stainless steel,100 mm size complete all as specified and directed. |
| 84 | M&L for preparation of new steel surfaces of steel and iron work of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 85 | M & L Surfaces of any description, n.exc 10cm in width or girth andwhen unconnected with other painting or when painted in a different tint with applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 86 | M&L for preparation of the newly plastered surfacesof wall & applying3 coats of white wash on wall surfaces complete all as specified and directed. |
| 87 | M&L for preparation of the newly plastered surfacesof ceiling & applying3 coats of white wash on ceiling surfaces complete all as specified and directed. |
| 88 | S&F Brass CP WHB mixer for mixing hot & cold water screwed down for table top wash basin for 15mm bore iron pipe complete all as specified. |
| 89 | S&F bib tap, cast copper alloy, screwed down high pressure with crutch of butter fly handle fancy type CP for 15 mm bore dia GI tubing complete all as specified and directed. |
| 90 | S&F 15mm angle cock chromium plated,cast copper alloy, with capston heads,scewed down high pressure, with or without lettered \"hot\" or Cold\" with long srewed shanks and flynuts, srewedfor iron pipe fixed complete all as specified and directed. |
| 91 | S&F 15mm,pillar taps Fancy type long body chromium plated,cast copper alloy, with brass ceramic disc spindle and capston heads,scewed down high pressure, with or without lettered \"hot\" or Cold\" with long srewed shanks and flynuts, srewedfor iron pipe complete all as specified and directed. |
| 92 | S&F tubular towel rail of brass chromium plated , 20 mm dia, D type, 60 cm long betweem flanges complete all as specified and directed. |
| 93 | S&F 5mm thick, 600mm wide rounded edge mirror of selected quality glass, with back polishig mounted and fixed with stainless steel decorativecap wahsers and screws set fixed on PVC rawl plugs complete all as specified and directed. |
| 94 | S&F sinks without drainage boardmade of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes pipe including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 95 | S & F 15mm dia steel tubing and connectiongalvanized with all fittings medium grade tube in floors, walls and ceiling, or fixed to wallor laid in floors complete all as specified and as directed. |
| 96 | S & F 20mm dia steel tubing and connectiongalvanized with all fittings medium grade tube in floors, walls and ceiling or fixed to wallor laid in floors complete all as specified and as directed |
| 97 | S & F 25mm dia steel tubing and connectiongalvanized with all fittings medium grade tube in floors, walls and ceiling or fixed to wallor laid in floors complete all as specified and as directed |
| 98 | S & F 50 mm dia steel tubing and connectiongalvanized with all fittings medium grade tube in floors, walls and ceiling, fixed to wallor laid in floors complete all as specified and as directed. |
| 99 | M& L for cutting of existing steel tubing for altration or additions or lengthening screw on pipe to form conectors of any size GI tubing complete .all as specified and directed |
| 100 | Cutting chases, pinning in, in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, in cement mortor 1:3 cutting not exceeding 10cm girth complete all as specified and directed. |
| 101 | S&F Rotational moulded poly-ethylene three layes insunation puffwater storage tanks (cylinderical vertical with closed top) 500 litres capacity, white in colourhoisted and fixed in position complete all as specified and directed. |
| 102 | S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top hoisted) triple layer in construction white in colour with cover and GI tank nipple and fixed in position including dismantling existing water tank etc complete all as specified and directed. |
| 103 | S & F Rotational moulded poly-ethylene multilayer water storage tanks (cylinderical vertical with closed top) 1000 litres capacity, triple layer in construction white in colour hoisted and fixed in position complete all as specified and directed. |
| 104 | S&F Ball brass valves , high pressure ,withpolythene float and fly nut complete & high-density plastic ball , suitable for 20 mm bore pipe, screwed for iron pipe complete all as specified and directed. |
| 105 | S&F for gun metal globe / gate value with iron wheel head screwed both ends for iron pipe of 15mm bore complete all as specified and directed. |
| 106 | S&F forgun metal globe / gate value with iron wheel head screwed both ends for iron pipe of 20mm bore complete all as specified and directed. |
| 107 | S&F ofvitreous china wash basin, white, table Top of 510mmx400mmx125mm , as approved by Engineer In charge Including waste coupling ,waste pipe and labour for fixing mixer ,pvc connection but including cutting for and pinning in ends of and including brackets complete all as specified and directed. Note : Pillar tap andPVC connection will be measured paid separetly. |
| 108 | S&FFloor mounted one piece(Including Flushing Cistern) pedestal pattern water closet with seat cover and inbuilt flush tank Size (mm) 380 x 630 X 660 including Soft Closing Seat Cover complete all as specified and directed. |
| 109 | S&F Vitreous China Urinals, half stall type white(excluding fjushing cistern, flush pipe and waste pipe complete including providing & fixing ;plugs bedding urinal against wall in cm 1:2 securing urinal to plug with bran screw complete all as specified and directed. |
| 110 | S&F for Heatth Faucet (ABS Body) mild steel chromium plated 15 mm diawith 1.25 meter PVC flexible bodypipe of CPincluding fixing bracket complete all as specified and directed. |
| 111 | S&F PVC connections 15 mm dia and 450 mm long with brass nutscomplete all as specified |
| 112 | S&F PVC (SWR) pipes, 75 mm bore, single sockets, in any length with rubber ring joints laid in floors or wall complete all as specified and directed. |
| 113 | S&F PVC (SWR) pipes, 110 mm bore, single sockets, in any length with rubber ring joints laid in floors or wall complete all as specified and directed. |
| 114 | S&F for 75/90 mm dia PVC(SWR)pipes single socketed, in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed. |
| 115 | S&F PVC (SWR) bends, 110 mm bore, any radius complete all as specified and directed. |
| 116 | S&F PVC (SWR) bends, 75 mm bore, any radius complete all as specified and directed. |
| 117 | M&L for PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed. |
| 118 | M&L PVC Floortrap 75mm dia with grating including jointing with solventcomplete all as specified and directed. |
| 119 | S& Fof 75mm dia PVC (SWR) multi floor trap with Hinge type SS grating including jointing with solvent cement complete all as specified and directed |
| 120 | M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 121 | M&L for cement concrete (1:3:6) type C2 using 40mm graded stone aggregate in bed to drain pipe including packing under and hunching against the sides of pipes after they are laid and tested complete for pipe size of 150mm bore complete all as specified and directed. |
| 122 | S&F HDPE double wall corrugated sewage pipe of 150 mm internal bore, SN-8, ISI marked as per IS 16908 Part-II-2013 laid in trenches, jointed and tested as per manufacturer instruction complete all asspecifed and directed. Make:Gemini-Tirupati Plastimatics Pvt Ltd, Jaipur (Raj)/ Keshav Kripa Polyplast (LLP), Kishangarh (Raj)/ Supreme Ultra Plus, Mumbai |
| 123 | Soakage well excavation in any type of soil Foundation PCC 1:3:6 Walls of honey combed masonary with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM RCC cover slab in M25/ SFRC Cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8MX 3MEffective Depth complete all as specified and directed. |
| 124 | M&L for concealed point wiringfor one light or fanpoint controlled by one switch with 1.5 Sqmm PVC-FRLS insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduitof size not less than 20mm ISI marked ivory white With all accessories,includingmodular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and directed and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . |
| 125 | M&L for concealed point wiringfor one5 Amp independent socket point controlled by one switch with 1.5 Sqmm PVC-FRLS insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduitof size not less than 20mm ISI marked ivory white With all accessories,includingmodular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and directed and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . |
| 126 | M&L for concealed point wiringfor one 3 pin ,5 Amp socket point with other switch on the same board with 1.5 Sqmm PVC-FRLS insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduitof size not less than 20mm ISI marked ivory white With all accessories,includingmodular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows,etc. of External diameter 20mmall as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and directed and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green all as directed by Engr-in-charge . |
| 127 | S&F Modular switch, one way,6 Amp 230, 1 module complete all as specified and directed. |
| 128 | S&F Modular socket6 Amp-2/3 pin combined 2 module complete all as specified and directed. |
| 129 | S&F ceiling rose, surface backlite,three terminal complete all as specified and directed. |
| 130 | S&F testing and commissioning of MCB SP 240 volt 6 Amp to 32 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. |
| 131 | S&F testing and commissioning of MCB SPN 240 volt 20/32 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. |
| 132 | S&F double door metallic sheet metal enclosure for DBdouble door(IP-43) When MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete all as specified and directed.Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces will be including in item rate . |
| 133 | M&L LED TL fitting 20 watt for surface and wall mounted LED batten with polycarbonate housing& integrated electronic driver long life corresion resistance impact proof surface mounting IP66 Lumanires PChousing in opeal finish coverwith high brighness complete all as specified and directed. |
| 134 | S&Fbox type LED optic fitting10/9 Watt2 feet box type complete all as specified and directed |
| 135 | S&F LED Bulk head 13/10 watt designed for modern homes available in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed. |
| 136 | Supply and fix exhaust fan AC single phase 230/240V of size 300mm sweep mettalic body with all accessories including making hole in stone/brick wall grouting and making god in all aspect complete all as specified and directed. |
| 137 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250MM complete all as specified and directed. |
| 138 | M&L for provn of earthing complete with MS galvanized earth plate electrode 600x600x6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below normal GL) with top edge of plate not less than 1.5 M below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of CI or steel incl excavation, PCC (1:3:6) type C-1 chamber with CI cover 10 mm thick, 15 mm dia light grade , GI protection pipe, funnel with wire mesh, watering pipe of size 20 mm dia, medium grade, lugs, main earthing lead upto main switch/DB incl charcoal dust, salt etc all as shown in electrical plate No. 3 of SSR part-I 2009 specification complete all as specified and directed. |
| 139 | Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade cross sectional area 6 sqmm 2 core complete all as specified and directed. |
| 140 | Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volt grade cross sectional area 10 sqmm 2 core complete all as specified and directed. |
| 141 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed. |
| 142 | M&L for40 mm dia GI pipe light grade laid under road and path for passing cablecomplete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy