Tender For Annual Maintenance Contract Work Of Of 33/11 Kv Substations Under Ee,Edd, Rs Ghat. Sl. No. Item Description 1 Providing And Replacement Of Kv Ct 600/300/5 As Per Resspo Norms. (Make Gcl, Bhel, Schemer, L&T Tosiba, Stel Etc. 2 Providing , Barabanki-Uttar Pradesh

Boards / Undertakings / PSU has published Tender For Annual Maintenance Contract Work Of Of 33/11 Kv Substations Under Ee,Edd, Rs Ghat. Sl. No. Item Description 1 Providing And Replacement Of Kv Ct 600/300/5 As Per Resspo Norms. (Make Gcl, Bhel, Schemer, L&T Tosiba, Stel Etc. 2 Providing . Submission Date for this Tender is 15-10-2024. Substation Tenders in Barabanki Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

45686318
Tender For Annual Maintenance Contract Work Of Of 33/11 Kv Substations Under Ee,Edd, Rs Ghat. Sl. No. Item Description 1 Providing And Replacement Of Kv Ct 600/300/5 As Per Resspo Norms. (Make Gcl, Bhel, Schemer, L&T Tosiba, Stel Etc. 2 Providing
Open Tender
Indian
Uttar Pradesh
Barabanki
15-10-2024

Tender Details

tender for Annual maintenance contract Work of of 33/11 kv substations under EE,EDD, Rs Ghat. Sl. No. Item Description 1 PROVIDING AND REPLACEMENT OF KV CT 600/300/5 As per RESSPO Norms. (Make GCL, BHEL, SCHEMER, L&T TOSIBA, STEL ETC. 2 PROVIDING AND REPLACEMENT OF KV CT 300/150/5 As per RESSPO Norms. (Make GCL, BHEL, SCHEMER, L&T TOSIBA, STEL ETC. 3 Repairing OF DEFECTIVE 11 KV POTENTIALTRANSFORMER 4 SUPPLY & REPLACEMENTOF DEFECTIVE 11 KV PANELO/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT 5 SUPPLY & REPLACEMENT OF DEFECTIVE 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT 6 REPLACEMENT & SUPPLY OF DEFECTIVE HT HRC FUSE FOR PT OF APPROPRIATE RATING 7 SERVICING AND REPAIRING OF MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 11 KV BREAKER WARRANTY PERIOD WILL BE SIX MONTH 8 REPLACEMENT AND SUPPLY OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING 9 REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING 10 REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING 11 REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY 12 REPLACEMENT AND SUPPLY OF DEFECTIVE SPOUT 13 REPLACEMENT AND SUPPLY OF DEFECTIVE JAW (MALE/FEMALE) FOR 11 KV VCB TROLLEY 14 REPLACEMENT& SUPPLY OF DEFECTIVE INDICATOR 15 REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER 16 REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER 17 REPLACMENT & SUPPLY OF DEFECTIVE TNC SWITCH 18 REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH 19 REPLACMENT & SUPPLY OF DEFECTIVE BUZZER 20 REPLACEMENT & SUPPLY OFDEFECTIVECLOSING COIL (24 V D.C) 21 REPLACEMENT & SUPPLY OF DEFECTIVE TNC SWITCH 22 SERVCING AND REPAIRING OF ELECTRICAL SYSTEM FOR PROPER METERING, OPENING, CLOSING & TRIPPING OF 11 KV BREAKER INCLUDING PROVIDING OF NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING AND OTHER NECESSARY ACCESSORIES. BATTRERY AND BATTERY CHARGER OVERHAULING & MAINTENANCE. WARRANTY PERIOD SIX MONTH 23 IN CASE OF EMERGENCY BREAKDOWN VCB REPAIRING ETC WORK LINE CLEANING AND FEFITTING AFTER REMOVAL OF FAULT WITH IN 1 HOUR AFTER GETTING INFORMATION AND WARRANTY PERIOD WILL BE SIX MONTH 24 PROVIDING AND ERRECTION OF PIPE EARTHING VIA 2 INCH DIA GI PIPE (3MM) UPTO 40 FEET 25 The work of safe carriage of the following material from Electricity store center Barabanki to work siteunder the jurisdiction of EDD-I Barabanki Approx. distance upto 30 Km. Including safe loading and unloading. 26 33 KV O/D VCB 1250 A 27 ACSR DOG CONDUCTOR 28 LINE ISOLATOR 800A 29 33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1 30 11 KV POTENTIALTRANSFORMER 31 11 KV CAT-A ENERGYMETER 32 ERECTIONWORK 33 INSTALLATION OF 33 KV O/D VCB 1250 A 34 ACSR DOG CONDUCTOR 35 INSTALLATION OF New 33 Kv CONTROL PANEL 36 INSTALLATION OF 33 KV line isolator 33 KV (800 Amp.) 37 REPLACEMENTOF DEFECTIVE 33 KV CURRENT TRANSFORMER 400/200/1 38 REPAIRING OF DEFECTIVE 33 KV PANELO/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT 39 SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT 40 SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL AUXILARY Relay WITH RETROFITTING ARRANGEMENT 41 REPLACEMENT & Supply OFDEFECTIVECLOSING COIL 42 REPLACEMENT & SUPPLY OFDEFECTIVETRIPPING COIL 43 REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF BREAKER 44 REPLACEMENT & SUPPLY OF DEFECTIVE TNC SWITCH 45 REPLACEMENTOF DEFECTIVE CONTROL CABLEFORM PANEL TO VCB 2*2.5 SQ MMARMOURED CABLE 46 REPLACEMENT OF DEFECTIVE CONTROL CABLEFORM PANEL TO VCB 4*2.5SQ MM ARMOURED CABLE 47 REPLACEMENT AND SUPPLY OF VCB CHARGING MOTOR OF APPROPRIATE RATING 48 REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING 49 REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING 50 REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY 51 REPLACEMENT& SUPPLY OF DEFECTIVELED INDICATOR 52 REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER 53 REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER 54 REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH 55 REPLACMENT & SUPPLY OF DEFECTIVE BUZZER 56 REPLACEMENT & SUPPLY OF DEFECTIVE WTI of Power T/F 57 REPLACEMENT & SUPPLY OF DEFECTIVE OTI of Power T/F 58 REPAIRING & SUPPLY OF DEFECTIVE MAGNETIC OIL GAUGE OF POWER TF 59 REPLACEMENT & SUPPLY OF DEFECTIVE BUCHOLTZ RELAY 60 REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF TRANSFORMER 61 SUPPLY AND ERRECTION OF SILICA GEL BREATHER COMPLETE FOR 10 MVA T/F. ALL REQUIRED MATERIAL WILL BE PROVIDED BY CONTRACTOR 62 SUPPLY AND ERRECTION OF ARCHING HORN. ALL MATERIAL WILL BE PROVIDED BY CONTRACTOR. 63 SUPPLY AND ERRECTION OF COPPERMESS FOR 11 KV SIDE CONNECTION NEUTRAL. ALL MATERIAL WILL BE PROVIDED BY CONTRACTOR 64 REPLACEMENT AND SUPPLY OF DEFECTIVE BREATHER WITH SILICA GEL 65 SERVICING OF ELECTRICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS INCLUDING PROVIDING NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING& SERVICING MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS & SERVICING 33 KV PANEL FOR PROPER OPERATION OF OPENING, CLOSING, TRIPPING, ALARM, INDICATION OF BREAKER INCLUDING PROPER INTERNAL WIRING OF PANELS AND PROPER WIRING BETWEEN PANELS, DC CHARGER, 33 KV BREAKER, 33 KV CTs, 33 KV PTs, POWER TRANSFORMER OIL TEMPRATURE INDICATOR, WINDING TEMPRATUREINDICATOR, OIL LEVEL INDICATOR, BUCHOLTZ RELAY ETC WITH PROPER CONTOL CABLE, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR. MAINTENANCE OF LIGHTING ARRANGEMENT IN SWITCHYARD & CONTROL ROOM ALSO AND OTHER IMPORTANT WORKS RELATED TO 33/11KV SUBSTAION, WARRANTY WILL BE SIX MONTH. 66 SUPPLY AND REPLACEMENT OF DAMAGED HEAVY DUTY PANTHER CONDUCTOR/ PG CLAMP IN SWITCH YARD 67 SUPPLY AND REPLACEMENT OF DAMAGED ISOLATOR JAW IN COMPLETE 68 RECTIFICATION OF POWER T/F LEAKAGE 69 Centifusing of 10 MVA T/F 70 Centifusing of 5 MVA T/F 71 Painting of All stracture of swicht yard such as terminal gantry, Bus gantry, Line Isolator, Bus Isolators, Fuse sets, CT Stractures, Breaker Stractures, LA Stractures, power transformer ((spray painting) Etc with one code of red oxide and two cote of Almuniam paint

Key Value

Document Fees
INR 3540 /-
EMD
INR 47500.0 /-
Tender Value
INR 47.30 Lakhs /-
Disclaimer :