}

Construction Of Officers Room And Temporary Shed For Kitchen, Bunker, Providing Campus Lighting, Generator And Supply Of Materials And Other Ancillary Works At Kulicherra, Lailapur, Joydhanpur, Crpf Camp At Assam- Mizoram Border In Cachar District (Phase-, cachar-Assam

Public Works Building and NH Department has published Construction Of Officers Room And Temporary Shed For Kitchen, Bunker, Providing Campus Lighting, Generator And Supply Of Materials And Other Ancillary Works At Kulicherra, Lailapur, Joydhanpur, Crpf Camp At Assam- Mizoram Border In Cachar District (Phase-. Submission Date for this Tender is 30-10-2024. Paver Blocking Tenders in cachar Assam. Bidders can get complete Tender details and download the document.




Tender Notice

45664810
Construction Of Officers Room And Temporary Shed For Kitchen, Bunker, Providing Campus Lighting, Generator And Supply Of Materials And Other Ancillary Works At Kulicherra, Lailapur, Joydhanpur, Crpf Camp At Assam- Mizoram Border In Cachar District (Phase-
Open Tender
Indian
Assam
Cachar
30-10-2024

Tender Details

Construction of Officers room and temporary shed for kitchen, bunker, providing campus lighting, Generator and supply of materials and other ancillary works at Kulicherra, Lailapur, Joydhanpur, CRPF camp at Assam- Mizoram Border in Cachar district (Phase-1)(Gr-I)-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 2 Filling available excavated earth (excluding rock) in trenches, plinthsides of foundations etc. in layers not exceeding 20cm in depthconsolidating each deposited layer by ramming and watering, lead up etc. 3 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete 4 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 6 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size) 7 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 8 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 9 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) 10 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete 11 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers 12 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts 13 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more 14 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) 15 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 16 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 17 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 18 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 19 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. 20 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm 21 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm 22 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm 23 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. completeElectric resistance or induction butt welded tubes 24 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement18 mm thick 25 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) 26 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 27 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) 28 CEMENT PLASTER (IN FINE SAND)15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer 30 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) 31 Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works 32 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 33 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 34 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats 35 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 36 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 37 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item)With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) 38 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm 39 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 40 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required :W.C. pan with ISI marked white solid plastic seat and lid 41 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 42 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 43 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm 44 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White 45 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.External workPN - 10 Pipe, 110 mm OD (SDR-11) 46 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipeshaving thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, i/c fixing the pipe with clamps etc.Concealed work, including cutting chases and making good the walls15 mm nominal dia Pipes 47 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipeshaving thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, i/c fixing the pipe with clamps etc.Concealed work, including cutting chases and making good the walls25 mm nominal dia Pipes 48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 49 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore 50 Providing and fixing factory made P.V.C. door frame of size 50x47 mmwith awall thickness of 5 mm, made out of extruded 5mm rigid PVCfoam sheet, mitred at corners and joined with 2 Nos of 150 mm longbrackets of 15x15 mm M.S. square tube, the vertical door frame profiles etc. 51 Providing and fixing factory made panel PVC door shutter consisting offrame made out of M.S. tubes of 19 gauge thickness and size of 19 mmx 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frameshall have a coat of steel primers of approved make and manufacture etc. -30 mm thick plain PVC door shutters 52 Construction of temporary shed of Bamboo structure , CI sheet wall and roofing with Barua/ jati bamboo post & post plate tying with plastic rope and Bethua / Baluka bamboo bracing and tie binding with CGI wire (18 Gauge) and fixing CGI sheet over bamboo purlins etc complete, the ci sheet wall tied with half bamboo kamies with post and bracing etc complete as specified and directed.1x5.50x3.65=20.075Sqm( Bunker)1x7.05x3.65=25.73 Sqm (Santry Post)6x6.05x4.50=190.35 Sqm ( Bunker)1x8.50x4.50 = 38.25 Sqm ( Bunker)1x8.50x6.05 = 51.425 Sqm ( Bunker)1x7.05x3.65 = 25.73 Sqm ( Bunker)1x8.50x3.65= 31.025 Sqm ( Kitchen at Kulichera)2x10x3.65=73.00 Sqm( Kitchen At M.A. Laskar CRPF camp)1x 8.50X 4.50 =38.25 Sqm(Bathroom at MA Laskar CRPF )1x 8.50X 4.50 =31.025 Sqm( Store room at MA Laskar CRPF)1x 8.50X 3.65 = 31.025 Sqm( Store Room at Kulichera) 53 Providing and Laying Factory made Chamfered Edge cement concrete paver block in park, footpath, lawns , drive ways or light traffic parking etc, of required strength , thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete as per direction of engineer in charge.. (ii) 80 mm thick paver block of M-30 grade with approved colour design and pattern. 54 Supplying, filling , ofGunny bagsfilled with specified sand/ silt ,Gunney bagsweighing not less than 35 kg, should be carry and laying proper location and position location as specified and directed. 55 Supply of 19 mm thick ply board ( Water Proof)60 nos x 3.125 sqm 56 Supply of CGI Sheet 460 nos(3.65mx1.20m) = 2014.8sqm235 nos(3.05mx1.20m) = 860.10 sqm400 nos (3.00m x 1.20m)= 1752 sqm 57 Supply of 20 mm Stone Aggregate With carrying and adding cost index difference 58 Supply of Sand With carrying and adding cost index difference 59 Supply of 1st Class Brick With carrying and adding cost index difference 60 Supply of Water Tank (2x500 Lit) including cost index difference 61 Flush Door Pannel ( 8 ft x 4 ft) 62 PVC door ( 7 ft x 2.5 ft) 63 TMT bar 10 mm dia 64 Ply board for celling ( 12 mm) ( 8 ft x 4 ft) 65 Structutal Steel L Section (1inch x1 inch) 66 Structural Steel T Section (1inch x1 inch) 67 Welding Rod 68 Enamel Paint( Berger) 69 Primer ( Berger) 70 Thinner 71 Distemper ( Berger) 72 External paint ( Berger) 73 White cement (J.K.) 74 GI Wire (18 Gauge) 75 Dao (TATA) 76 Shovel (TATA) 77 Axe (TATA) 78 Kudal (TATA) 79 Barua / Jati Bamboo 80 Bethua 81 Cement 82 6 mm MS Coil 83 Black Wire 84 GI Pipe 2inch (20 Feet) 85 J hook with Washer 86 Cutting blade 87 W. C. Seat 88 PVC Pipe 4 inch (20 Feet) 89 PVC Bend 4 inch (20 Feet) 90 PVC Tee 91 Door Handle 92 Tower Bolt 93 Basin 94 Mirror 95 Bib Cock 96 Piller Cock 97 Flushing Cistern 98 UPVC Pipe 20mm 99 UPVC Solvent 100 PVC Pipe 6 inch (20 Feet) 101 PVC Elbow 6 inch 102 UPVC pipe 15 mm dia. 103 UPVCElbow 15mm dia 104 UPVC Brass Elbow 15mm/ 105 UPVC Brass Tee 15mm 106 UPVCUnion 20mm 107 UPVC Elbow 20mm 108 UPVC R/Tee 20 x 15mm 109 UPVC coupler 20mm 110 UPVC tank Nipple 20mm 111 UPVCTee 15mm 112 Taplon Tap 113 Stop cock 15mm 114 2 in 1 Angle cock 115 Safety tank 850 Ltr. 116 Self pragyag 117 UPVC brass FTA 15mm 118 Jet Spary 119 Concealed stop cock 120 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 121 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 122 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 123 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire 124 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A 125 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group B 126 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group C 127 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch 128 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch 129 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet 130 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet 131 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module . 132 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 4 Moudle. 133 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Moudle 134 Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 135 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 136 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 137 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 138 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door 139 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door 140 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 141 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 142 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 143 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 144 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required. 145 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 146 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 147 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 148 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 149 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 150 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm 151 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 152 Generating Sets.Supplying , Installaion , testing & commissioning of D.G. sets AMF panel, bus ducting/ cables from DG sets to essential panel DG sets enclose room sound insulation/ventilaton/ smoke exhaust as reqd. earthing of DG set exhaust piping exhaust /exhaust piping/exhaust chimney as per CPCB norms, civil works connected with D.G. sets including foundation as required. 153 Supplying with fitting & fixing 63Amp, 4-pole, 415V front handle operated open execution on load changeover switch fitted in sheet steel encloser of the following capacity complete with making necessary connection.(L&T make) 154 Supplying of A/C Ceilling fan of the following sweep model etc. without regulator . Eco Ceilling fan 1200mm W/O Reg. white. 155 Supply of following size PVC/XLPE Insulated and PVC sheathed 1.1KV grade solid Aluminum conductor up to 10sq mm balance slandered conductor XLPE insulated cores laid up PVC tape inner sheathed Armour (galvanized wire for cable up to 2x10 sqmm galvanized steel strip.) extruded PVC type ST2 sheathed 650/1100 volts grade as per 15.7098(Part-1) 1988. (R.R. Kable or equivalent make).10sqmm 2-core. 156 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1KV grade solid Aluminum conductor up to 10sq mm balance slandered conductor XLPE insulated cores laid up PVC tape inner sheathed Armour (galvanized wire for cable up to 2x10 sqmm galvanized steel strip.) extruded PVC type ST2 sheathed 650/1100 volts grade as per IS.7098(Part-1) 1998. (R.R. Kable /Havells make).25sqmm 3% core 157 Supplying Domestic Exhaust fan 225mm size Model No-Spring Air (Orient make). 158 Supplying with fitting fixing of 7watt LED bulb.(ANCHOR/PANASONIC). (as per COs price) 159 Supplying with fitting & fixing of LED batten tube light-20watt 4th length including connection etc. (Anchor, Panasonic or equivalent make). 160 Supplying with fitting & fixing of LED Street light including lamp, dinner, ballast etc. of 25W Green line (Anchor, Panasonic or equivalent make) (Cod No.- PSTMO1257) 161 Supplying of 22 LCD TFT Screen (Samsung/Panasonic make). 162 Solar Street light with LED fixture

Key Value

Document Fees
INR 3000 /-
EMD
INR 258746.0 /-
Tender Value
INR 1.29 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail