}

Tender For Work Of Replacing Damaged Cables And Timers Of Old Poles With New Cables And Timer Parts In Municipal City Area., Bharatpur-Rajasthan

Local Bodies has published Tender For Work Of Replacing Damaged Cables And Timers Of Old Poles With New Cables And Timer Parts In Municipal City Area.. Submission Date for this Tender is 16-10-2024. Bolts Tenders in Bharatpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

45620087
Tender For Work Of Replacing Damaged Cables And Timers Of Old Poles With New Cables And Timer Parts In Municipal City Area.
Open Tender
Indian
Rajasthan
Bharatpur
16-10-2024

Tender Details

Work Of Replacing Damaged Cables And Timers Of Old Poles With New Cables And Timer Parts In Municipal City Area. , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 Core , Add Extra For Laying Of One Number Additional Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation Of Trench Of Size Additional 20 Cm In Width, With Procedure As Per Following Points :- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay Another Cable In Middle Of Trench In Such Manner That Spacing Between Another Cable Is 20 Cm., (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable.(D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 /Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supply And Fixing Of Following Lt Supporting Accessories With Nut Bolt & Clamps Made Out As Per Standard Discoms Specifications With Two Coats Of Red Oxide And Two Coats Of Aluminium Paint Etc. As Required. All As Per Pre Approved By Engineer In-Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Lt Cross Arm 600 Mm Long With Clamp , Providing & Fixing Of Ac Operated Heavy Duty 230 /440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is/Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr 4 Pole Power Contactors With Following Ac 1 Rating , Providing & Fixing Of Mechanical / Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 60730-1 And 60730-2-7 Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . One Day & Week Reserve (Digital Type , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer Incharge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Four Pole Mcb 40 A Rating , Supply And Fixing Of Lt Porcelain Shackle Insulator As Per Is:1443 1979 And As Per Discoms Standard Specifications, Suitable For Working Voltage 1100 Volts Including All Accessories Like Gi Hardware Fittings Confirming To Is:7935/1975 (Latest Amended) Nut, Bolt Etc. As Required. All As Per Pre Approved By Engineer Incharge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 75Mm X 90Mm

Key Value

Document Fees
INR 1000 /-
EMD
INR 49326.0 /-
Tender Value
INR 24.66 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail