}

Shifting Of Sub Station Equipments With Allied Works From Ess Tamilnadu House To Ess Bardoloi Marg And Installation Of 11Kv Panels With Allied Works At Ess West Bengal Guest House Chankya Puri New Delhi, NEW Delhi-Delhi

New Delhi Municipal Council has published Shifting Of Sub Station Equipments With Allied Works From Ess Tamilnadu House To Ess Bardoloi Marg And Installation Of 11Kv Panels With Allied Works At Ess West Bengal Guest House Chankya Puri New Delhi. Submission Date for this Tender is 16-10-2024. Footwears Tenders in NEW Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

45615702
Shifting Of Sub Station Equipments With Allied Works From Ess Tamilnadu House To Ess Bardoloi Marg And Installation Of 11Kv Panels With Allied Works At Ess West Bengal Guest House Chankya Puri New Delhi
Open Tender
Indian
Delhi
New Delhi
16-10-2024

Tender Details

Shifting Of Sub Station Equipments With Allied Works From Ess Tamilnadu House To Ess Bardoloi Marg And Installation Of 11Kv Panels With Allied Works At Ess West Bengal Guest House Chankya Puri New Delhi- 1 Dismantling of existing 1600KVA transformer and disconnectionof HT & LT Cables , Bus-Ductingand other connections etc as per site requirement. 2 Cartage, Loading , unloadingincluding dragging and positioningof 1600 KVAtransformer from Tamilnadhu House Kautilya Marg To ESS Bardolai Marg as per the site requirement 3 Dismantling of existing 11KVPanels includingdisconnection of existing cables , Bus coupling ,earthing etc. & as per the site requirement [ESS Tamilandu House- 3 Nos. & ESS West Bengal Guest House -3Nos. ] 4 Dismantling of C&RPanels includingdisconnection of existing cables , earthing etc. & as per the site requirement [ ESS West Bengal Guest House -3Nos. ] 5 Cartage, Loading , unloadingincluding dragging and positioningof 11KV PanelsandC&R Panelsfrom ESSto NDMCstore/siteas per site requirement 6 Dismantling of existing LT ACB Two Tier Panels including disconnection of existing cabels,Bus Ducting,coupling , earthing etc. as per the site requirement 7 Cartage, Loading , unloadingincluding dragging and positioningof LT ACB Two Tier PanelsESS Tamilnadu Houseto ESS Bardoloi Marg as per site requirement 8 Dismantling and cartage of old existing Battery Tripping Unit from existing ESS Tamilnadu House to NDMCstore as per site requirement 9 Handling/Dismantling of 11KV & 1.1KV Cables of different sizes which are not laid in ground but part of it going up to panel or part in the building 10 Drawing/Dismantling of 11KV & 1.1KV Cables of different sizes in RCC Pipe/HDPE Pipe/Duct/ 11 Dismantling &Cartageof Bus Ducting from Existing electric Sub-Station Tamilnadhu House to ESS Bardaloi Margas per Site requirement 12 Installation, Testing and Commissioning of 11 KV HT VCB Panel complete in all respect as per site requirement 13 Installation, Testing and Commissioning ofLT ACB Two Tier Panels complete in all respect as per site requirement 14 Installation , Testing and commissioning of 1600 KVA dryType Transformer including connection of 11KV Cables, LT Cables/Bus Ducting etc as per site requirement 15 SITC of Battery Charger Unit along with MF batteries of rating 220V AC (Input) & output of DC 24V to 36V suitable for HT Panel, 100 AH as per specifications, complete in all respect as per site requirement. 16 Installation and commissioning of LTBus trucking including bus ducting (02 Nos. of Aluminimum Bus Bars for each phase and 01 No. for neutral ) , nut bolts, washers complete in all respect as per the site requirement 17 Modification , Installation and commissioning of LTBus trucking including bus ducting (02 Nos. of Aluminimum Bus Bars for each phase and 01 No. for neutral ) , nut bolts, washers complete in all respect as per the site requirement 18 Supplying, Installation, Including suspension, testing and commissioning of bus ducting for 2500Amps. for 415 Volts AC 50Hz rating Capacity bu strunking with aluminium bus bars having current density of 130A/ sq cm at nominal current rating in 1.6mm thick IP 42 sheet steel enclosure in convenient sections for use on 3 Phase, 4 wire , 415 Volt , 50 HZ AC supply including jointing of sections, flexible joints , expansion joints , bends and earthing with 2 runs of galvanized iron strips , suspenders , angle iron bracket , steel fasteners connecting to earthing systems etc as required. 19 Repairing & Servicing of 11KV VCBand Panel ,there operational mechanism, cleaning, oiling, alignment of breakers in panels,providing minor wiring of relays, indicating lamps, selector switches, push buttons, cleaning of carbon from bus bars and providing insulating coating with antioxidant treatment on 11KV bus bars chambers, cleaning of CTs Chamber, PTs Connections,making panel inworking conditionsas per the site requirement 20 Repairing & Servicing of LT 2 Tier Panels , cleaning of bus bars with sleeving including replacement of indication LED lamps & minor parts etcand servicing of LT ACBsincluding testing,providing minor partsas per the site requirement I making panel for smooth operation. 21 Supplying and making indoor end termination with heat shrinkable jointing kit complete with all accessories including lugs for 150sqmm/3C , XLPE aluminimum Conductor Cable of 11KV Grade Make : 3M/Raychem/Cabseal 22 Providing Maintenance free & water less earth grid to deliver earth result not exceeded more than 2 ohms for substations equipment i.e. distribution transformer body, neutral and HT Panel, LT Panel Board by providing & fixing copper bonded MS earth electrodes of appropriate size and length in convenient pieces and embedded vertically in ground after making a bore of appropriate diameter and filling the bore with an earth enhancing compound. Interconnecting the multiple earth electrodes with 50 X 6mm copper bonded MS strip below 500mm surface level. Filling the surrounding of bore with fresh soil complete in all respect including connecting test link at two places and providing masonry enclosure with RCCframe & cover. Two connections point with test link from earth electrode shall be taken up to surface level for connecting conductor to the equipment. All Earthing connections should be exothermically welded.[Transformer Body-2, Transformer Star Point-2, 11KV Panel-2, LT Panel-2 ] 23 Providing & Fixing of 25 mm x 5 mm G.I. Strip in 40mm GI Pipe from earth electrode including connection with brass, nut, bolt, spring washer excavation and refilling as required, complete in all respect as per site requirement. 24 Providing and Fixing 25mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required. 25 Supplying and laying of ISI marked PVC insulated, sheathed, armoured, copper conductor of size 2.5 sq.mm/4 C control cable for working voltage up to 1.1 KV in recess/ on surface/ in G.I. pipe/cable trays etc from Battery Tripping Unit to HT panel complete in all respect as per site requirement. Make: Plaza/Havells/Finolex/RRCable/KEI/Polycab 26 Supplying and laying of ISI marked PVC insulated, sheathed, armoured, copper conductor of size 2.5 sq.mm/10 C control cable for working voltage up to 1.1 KV in recess/ on surface/ in G.I. pipe/cable trays etc from HT Panel to Transformers for the connections of WTI ,Bucheloz Relay etc complete in respectas per site requirement. Make:Plaza/Havells/Finolex/RRCable/KEI/Polycab 27 Providing and Fixing of synthetic insulating mat 2.5 mm thickness and 1 Mtr width suitable for 11 KV HT Panel board ISI marked having di-electric strength 45 KV, confirming to IS 15625:2006, complete in all respect as per site requirement. 28 Providing and Fixing of Meter Box for 3 phase energy meter along with Test Terminal Block (TTB) of suitable size fabricated from 1.6 mm MS sheet duly powder coated including P/F Bakelite sheet of suitable size with locking arrangement, complete in all respect as per site requirement. 29 Supplying and Fixing Fire Extinguisher CO2 (4.5 Kg) complete in all respect as per site requirement. 30 Supplying and Fixing Fire Bucket complete in all respect as per site requirement. 31 Supplying and Fixing of First Aid Box complete in all respect as per site requirement. 32 Supplying & fixing of ESS name plate (2 feet x 2.5 feet) complete in all respect as per site requirement. 33 Supply & fixing of Caution Boards as per site requirements 34 Supply & fixing ofcable Boots suitable for 11KV Cable of size 400sqmm for each phase as per site requirement Make: 3M/Raychem/Cabseal/ABB/Seimens 35 SITC of 11 KV Indoor epoxy resin casted CT single wound for metering CT (as per actual load) class 0.5p10 VA burden 5, short time current 18.4 KA/1 sec insulation level 12/18/75 KVP as per ISS 2705/1992 for 11 KV HT panel. (03 Nos. in One Set), complete in all respect as per site requirement.MAKE: AE/Kappa/Areva/Crompton/Savio/Hans

Key Value

Document Fees
Refer document
EMD
INR 48194.0 /-
Tender Value
INR 24.09 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail