| 1 | Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Siliguri.(a) Depth of excavation not exceeding 1.500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earthin layers not exceeding 150 mm. including watering and ramming etc.layerby layer complete . (a) With earth obtained from excavation of foundation. |
| 3 | Single Brick Flat Soling of picked jhama brick including ramming and dressing bed to proper level and filling joints with Powdered earth or local sand. |
| 4 | (II) Cement concrete with 30 mm. down graded shingles excluding shuttering.In ground floor or foundation(b) N.B. veriety(a) 1:3:6 proportion |
| 5 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(b) River bazree. |
| 6 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction(a) For works in foundation and upto roof of ground floor/upto 4 m SAIL/ TATA/RINL |
| 7 | Hire and labour charge for shuttering with centreing and necessary staging up to 4 m. using approved stout props and thick hard wood planks of approved thick ness with required bracing for concrete slabs, beams,columns, lintels curved or staight including fitting fixing and striking out after complection of works. (up to roof of ground floor).(a) 25mmto30mm thick wooden shuttering as per decision & direction of the Engineer-in -charge. |
| 8 | 125 mm thick brick work with 1st class brick\"s in Cement mortar (4:1) in ground floor. |
| 9 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar, including rounding off corners or chamfering corners as directed and recking out joints or roughening of concrete surface.a) with (4:1) cement mortor (b)20 mm thick plaster |
| 10 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m |
| 11 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white |
| 12 | (B)WALL Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white |
| 13 | Providing and fixing factory made door frame (single rebate) made of single piece extruded solid PVC profile with homogenous fine cellular structure having smooth outer integral skin having 62mm width x 32 mm thickness (the door frame is to be made with single piece extruded solid pvc profile whereas no sheet pasted profile shall be applied for door frame fabrication) and shall be fixed to wall asper instructions of Engineer – in – charge using 100 x 8 sheet metal CSK screws. |
| 14 | ( Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC DoorShutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out ofwhich 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th.both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles&rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner sideand joined together with solvent cement adhesive. An additional 5 mm th. PVCstrip of 20 mm which is to be stuck on the interior side of the “C” channel usingPVC solvent adhesive etc. complete excluding all |
| 15 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:(v) 100 x 63 x 3.2mm. |
| 16 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S.230/72) fitted and fixed complete:.(a) With continuousplate base (hexagonal/round rod).(iv) 150 mm grip x 10 mm dia rod. |
| 17 | Anodised aluminium Aldrop/ Sliding bolt of approved manufactured from extruded section conforming to I.S. 2681/66fitted and fixed complete. (i) 250 mm 16 mm dia bolt |
| 18 | Anodised aluminium barrel/ tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74fitted and fixed with cadmium plated screws.(iii) 100mm longx10mm dia bolt |
| 19 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)Add extra for each additional floor over the rate forground floor for the above item when used on ExternalSurface |
| 20 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receiveDistemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per anufacturer\"s specification and as per direction of the EIC. (In Ground Floor)(b) two coatsii) Solvent based interior grade Acrylic Primer |
| 21 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of theEIC.(b) two coats |
| 22 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty(to be done under specific instruction of Superintending Engineer) :(Two coats) |
| 23 | a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 24 | Sanitary and Plumbing Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding \"P\" or \"S\" trap (excluding cost of concrete for fixing). (i) 530 mm x 410 mm size. |
| 25 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work(6:1) band all round and cement brick work(6:1) upto 0.90 metre from top with 19 mm thick cement plastering(4:1) to inside face upto the depth of cement brick work, 12 mm thick cement plaster(4:1) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal(50 mm to 63 mm size) including R.C.C. cover slab of designed thickness with cement concrete(4:2:1) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making necessary arrangements for pipe conections, excavation of well including shoring, dewatering and remeving the excess earth from the premisis as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work(6:1) and 1.00 m. inside dia. |
| 26 | Construction of Septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (4:1) including two 560 mm dia. R.C.C. manhloe cover of approved make supplied, fitted and fixied in the top slab with necessary fittings, 19 mm thick cement plaster(4:1) with neat cement finish to the internal surfaces and 12 mm thick plaster(4:1) to outside wall upto 200 mm below G.L. floor finished with 25 mm thick grey artificial stone including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavating earth in all sorts of soil, shoring, bailing and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tank with earth, removing spoils, fliing up the chamber with clear water, removing foreign materialsfrom the chamber and including constructing attached inspection pit as per approved dawing and connecting all necessary pipes, joints etc. with internal plaster work and artifFor 10 users.with Bazree (N.B.Variety). |
| 27 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre linemeasurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)For Concealed Works15mm |
| 28 | Supplying PVC water storage tank of aroved quality ferrule including connection with G.I. pipes of TATA make of following dia.and upto 450 mm long with screw, jamnut, socket etc., complete in all respect , including cutting trenches in all sorts of soil and filling up the trenches as per direction of the Engineer-in-charge.500 litre |
| 29 | Supplying, fitting and fixing pillar cock of approved make.d) Polythene Piller Cock (EMCO / ATLAS or equivalent)(i) 15 mm |
| 30 | Wash basin vitreous china of approved make (without fittings)supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm woodblocks and C.I. brackets including two coats of painting of C.I. brackets. |
| 31 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.(ii) 470 mm X 280 mm X 340 mm |
| 32 | Add 18 % GST |
| 33 | Add 1 % Laboaur Cess |