Jal Jeevan Mission Water Supply Project For Kanhegaon Tal Shrirampur Dist. Ahmednagar Jal Jeevan Mission Water Supply Project For Kanhegaon Tal Shrirampur Dist. Ahmednagar - Sub Work No.1 : RISING MAIN Item No. 1 :Providing and supplying in standard lengths ISI mark rigid unplasticisedPVC pipes suitable for potable water with solventcementjointsincludingcostof couplers, as per IS specification no. 4985 / 1988includingallstatutarydutiesand taxessuchasGSTleviedbyGoland GoM in all respect, transportation, freight charges, inspection charges, loading, unloading,conveyancetothe departmental stores / site and stacking the sameinclosedshedduly protectedfrom sun rays and rains including cost of jointingmateriali.e.solventcement,etc. complete(selffittypetobejointedwith cement solvent).A) 90 mm dia. PVC Pipe 6kg/cm2 2 Item No. 4 : Providing & supplying ISI mark CI D/F reflux valve (Non- returnvalve)offollowingdiaincludingalltaxes(central andlocal), railwayfreight, inspectionchargesunloading from railway wagon, loading into truck, transportation upto department stores/site, unloading, stacking etc. complete. reflux valves as per I.S.5312 part I (1984)A) Reflux valves 80 mm Dia 3 Item No. 5 :ProvidingandsupplyingAirvalvesasperIS-10845and MJP’s standard specifications of approved mark and quality offollowingdiametersincludingalltaxes (Central andlocal),railwayfright,inspectionchargesunloading fromrailwaywagons,loadingintotruck,transportation upto departmental stores/ site, unloading and stacking etc. complete.Air Valve 50 mm Dia 4 Item No. 7 :Excavationforfoundation/pipetrenchesinhardmurum and boulders, W.B.M. road including removing the excavatedmaterialuptoadistanceof50Mbeyondthe area and lifts as below, stacking and spreading as directedbyEngineer-in-charge,normaldewatering, preparingthebedforfoundationandexcludingback- filling, etc. complete. 5 Item No. 11 : Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameterincludingcostofconveyance from stores to site of works including cost of alllabour, material, except cement solvent,rubberring, etc.complete(with cement solvent joint / ring fit joint).A) 90 mm dia. PVC Pipe 6kg/cm2 6 Item No. 12 : Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) A) Sluice valves+Reflux valve+Sluice valves washout 80 mm Dia 7 Item No. 13 : Lowering,Laying andfixing inproper alignmentand position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete.Air Valve 50 mm Dia 8 Item No. 14 : Providingandfixinginpositionairvalveshaftincluding providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providingPCCblockofM-150concrete150mmthick aroundtheairvalveteeincludingencasingofvertical shaft in PCC M-150 as shown in type design together with providingandmakingflangedjointswhereverrequired and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.) upto 150 mm on Murum & harder strata 9 Item No. 15 : ProvidingandlayinginsitufollowinggradesofC.C.of trap/granite/quartzite/gneissmetalforfoundationand bedding including dewatering, form work, compacting and curing, finishing etc. complete.a) 1:2:4 (M-150) grade for encasing 10 Item No. 16 : ProvidingandconstructingB.B.masonryvalvechamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5proportion 12 mm thickcementplasterincm1:4proportiononbothsides with providing and fixing C.I. manhole frame and cover in RCC1:2:4copingorcmthickslabetc.completeas directed by Engineer-in-charge. Size 0.9 x 0.6 x 0.9 11 Item No. 18 : HydraulictestingofPVCpipelinetospecifiedpressure includingcostofallmaterialsandlabourandwaterfor testingforspecifiedlengthincludingcutting,placingend cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments,labour,operationcharges,etc.requiredfor testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. A) 90 mm dia. PVC Pipe 6kg/cm2 12 Sub Work No.2 : DISTRIBUTION SYSTEM Item No. 1 :Providing and supplying in standard lengths ISI mark rigid unplasticisedPVC pipes suitable for potable water with solventcementjointsincludingcostof couplers, as per IS specification no. 4985 / 1988includingallstatutarydutiesand taxessuchasGSTleviedbyGoland GoM in all respect, transportation, freight charges, inspection charges, loading, unloading,conveyancetothe departmental stores / site and stacking the sameinclosedshedduly protectedfrom sun rays and rains including cost of jointingmateriali.e.solventcement,etc. complete(selffittypetobejointedwith cement solvent). A) 90mm dia. PVC Pipe 4kg/cm2 13 Item No. 5 :Excavationforfoundation/pipetrenchesinhardmurum and boulders, W.B.M. road including removing the excavatedmaterialuptoadistanceof50Mbeyondthe area and lifts as below, stacking and spreading as directedbyEngineer-in-charge,normaldewatering, preparingthebedforfoundationandexcludingback- filling, etc. complete. 14 Item No. 10 : Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves)A) Sluice valve+ Sluice valve for washout 80 mm Dia 15 Item No. 11 : ProvidingandlayinginsitufollowinggradesofC.C.of trap/granite/quartzite/gneissmetalforfoundationand bedding including dewatering, form work, compacting and curing, finishing etc. complete.a) 1:2:4 (M-150) grade for encasing 16 Item No. 12 : ProvidingandconstructingB.B.masonryvalvechamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5proportion 12 mm thickcementplasterincm1:4proportiononbothsides with providing and fixing C.I. manhole frame and cover in RCC1:2:4copingorcmthickslabetc.completeas directed by Engineer-in-charge. Size 0.6 x 0.45 x 0.9 17 Item No. 14 : HydraulictestingofPVCpipelinetospecifiedpressure includingcostofallmaterialsandlabourandwaterfor testingforspecifiedlengthincludingcutting,placingend cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments,labour,operationcharges,etc.requiredfor testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. A) 90mm dia. PVC Pipe 4kg/cm2 18 Item No. 15 : Providingandfixingboarddisplayinginformation, such as Name of work, Tender cost, Name of Contractor, Work completion and liability period etc, havingrectangularshapeof1.20mx0.90msize made out 18 gauge (1.25 mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stoveenamelonbacksideandborder/messages /symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x35 x3 mm frame with properly cross braced M.S.angles of size 35 mm x 35 mm x 3 mm duly painted including Two M.S.angle iron posts of size 65 mmx 65 mmx 6 mm, 3.65mlongpaintedwithalternateblackandwhite bandsof25cmwidthincludingallfixturesetc.and fixing the boards in1:4:8 concrete block of size 60 cm x60cmx75cmincluding,excavation,refilling, transportation,andlabouretccomplete.Spec. Number As directed by Engineer in Charge MORTH 801 19 Sub Work No.3 :RCC ESR of CAPACITY 35000 Ltr 18 mtr staging htItem No. 1 - DesigningandconstructingR.C.C Elevated service reservoir of following capacitywithRCCstagingconsisting of columns, internal and external bracings,spaced vertically not more than 4.5 m c/c including excavation in all types of strata foundationconcrete cementconcretewithwaterproofing compoundtotheinside faceofthe containerincluding refilling disposing of the surplus stuff within a lead of 50 m all labour and material charges includinglowering,laying,errrecting, oistingandjointingofpipeassembly of inlet,outlet,washout,overflow and byepassarrangementasper departmental design providing and fixing accessories such as M.S.ladder, C.I.manholeframeandcoverwater level indicators, Lightening conductors G.I.piperailingaroundwalkwayand top slab, providing spiral staircase from ground level to rooflevel,B.B.masonry chambers for all Capacity of ESR Proposed 20 Item No.2 : Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.outlet, Overflow,INLET GI MEDIUM PIPE 125 mm 21 Item No.3 : Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.Inlet, Washing GI MEDIUM PIPE 150 MM DIA RATE(providing 1257 + lowering 144 22 Item No. 4 : Providing and supplying double flange sluice valves confirming for IS 2906/14846 including warn gear arrangement as per test pressure stainless steel spindle capsexcluding GST levied by Gol and GoM in all respect , transportation etc complete.Sluice Valve 100 mm Dia ( PN -1.6 ) Basic Price + Lowering =9005+2272) 23 Sub Work No.4 : PercolationWELL Excavation in general in soft material comprisingof soft soil, soft murrum, sand, hard murum with boulders in wet or dry condition for Head Works I.e. intake well, connecting pipe Jack well, pump House, supplywelletc.forlift0to1.5M&leadof1.50M includingbarricading,guarding,depositingoft surplus excavated stuff within a radius of 0.5km as directed by Engineer-in-charge-,etc complete excluding refilling. lift 0.00 to 1.5 mt 24 Lift1.50 to 3.0 m 25 Lift3.00 to 4.5 m 26 Lift4.50 to 6.0 m 27 Item No. 2 : Dewatering the excavated trenches & pools of water in the building trenches/pipeline trenches/ well works byusingpumpandotherdevicesincluding disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. 28 Item No. 3 ; ProvidingandlayinginsitucementconcreteM-10/1:3:6 of trap/granite/quartzite /gneiss metal for foundationandbeddingincludingbailing-outwater manually formwork, compacting, covering newly laid concretebygunnybag,plasticortarpaulin,curing etc.complete.(Woodenplanks/shutteringwillnot beallowed)Spec.No.:Bd.E.1PageNo.287/IS 456:2000 29 Item No. 4 : providing & casting in situ C.C. of trap / granite trap / granite / quartzite / gneiss metal of approved quality for RCC work as per detaileddrawing & design or as directed byEngineer-in-chargeincluding dewatering,centeringfromworkcompaction, finishing the formed surfaces with C.M.(1:1 1/2:3) of sufficientminimumthicknesstogiveasmooth& evensurfacewherevernecessaryorrougheningif special finish is to be provided & curing etc. complete.(ByweighbatchingandmixM200.Only useofL&T,A.C.C.,Ambuja,BirlagoldManikgad, Rajashree, etc. cement is permitted. Excluding M.S. or Tor reinforcement. For RCCM 200a)R.C.C. Ring beam. 30 b) R.C.C. Ring Wall 31 Item No. 5 : Providing & fixing in position steel bar reinforcement of various dia. for RCC pipes, caps, footings, foundation,slabs,beams,columns,canopies, staircases,newelschajjas,lintels,pardiescopings fins, arches, etc. as per detailed design & drawing & schedules,includingcutting,bending,hookingthe bars,bindingwithwiretrackwelding&supporting as required, etc. complete. Tor Steel 32 Item No. 6 : DrillingofHorizontal borewell150mmdiabyD.T.C. machine, including transportation of machine at work site 33 Item No. 7 : Carryingoutrecuperation/yeildtestforascerting thedischargeofconstructedwell asdirertedby Engineerincharge.The test carried out by drawing downwaterfromthewellbelownormal/subsoil waterleveluptofulldepthriseinwaterlevelis recorded. . to the test including cost of all materials.overhead,labours etc. completed as directed. Thetestshallbecarriedoutasper technical circular No.2597 dt. 20/11/97 and shall be carried out for 7 days. 34 Sub Work No.5 : PumpHouseItem No. 2 : Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) PWD DSR 2021-22 I. No 21.06For Column Footing 35 Item No. 4 :Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand PWD DSR 2021-22 I. No 24.01 For Column Footing,Below flooring,steps 36 Item No. 5 : Providing and laying in situ/Ready Mixcement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage andfootings of R.C.C. columns and steel stanchionsetc. including bailing out water, formwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand PWD DSR 2021-22 I. No 25.11 For Column Footing 37 Item No. 7 :Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand PWD DSR 2021-22 I. No 25.50 38 Item No. 11 :Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. PWD DSR 2021-22 I. No 27.05 39 Item No. 13 :Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.BD-T-34Page No. 499PWD DSR 2021-22 I. No 39.09 40 Item No. 14 :Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, oil painting two coats complete.PWD DSR 2021-22 I. No 39.19 41 Item No. 15 :Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand PWD DSR 2021-22 I. No 26.05 42 Item No. 16 :Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.MJP SSR 2021-22 corigendum no.7 43 Item No. 18 :Providing external cement plaster 20mm thick in two coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. completed PWD DSR 2021-22 I. No 32.06 44 Item No. 19 :Providing and laying Polished Shahabad Stone flooring 25mm to 30mm thick and required width wide in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, filling joints, with neat cement slurry, curing, polishing and cleaning etc. complete.PWD DSR 2021-22 I. No 33.04 45 Item No. 22 :Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour tonew plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.PWD DSR 2021-22 I. No 35.15 46 Vertical drop pipe 100 mm GI Heavy Duty 47 GI bend B Class 100 mm 48 GI TEE B Class 100 mm 49 Fabricating LT panell - in 12mm thick Plywood 50 Change over switch 63 amp., Pole 51 Earth leakage circuit brekar 63Amp 4 Pole (RCCB) 52 Pilot lamps - 3 nos 53 c) Cable joint kit 54 D.O.L startar 55 TPM SWITCH 32 Amp 56 M.S. Frame for Pannel Board (Iron Work) 57 L.T. Capacitor 58 Sluice Valve (PN - 1.6) 100 mm dia 59 Reflux Valve (PN - 1.6) 100 mm dia 60 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP 61 Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. 62 Providing and fixing M.S. chequerred plate flooring of following thickness supported on M.S. angles (25 x 25 x 5 mm size) including welding, cutting and fabricating the plates to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge. 63 Providing and fixing G.I. pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thick M.S. angles as verticals at 1.5 M c/c and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal and painting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour and shade including cost of all labour, transporting bends to curved shape, etc. complete( With 3 Rows) 64 Providing structural steel work in single stanchions composed of RSJ, channel, etc. with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. as per detailed design and drawing or as directed by Engineerincharge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (BdC-6/2a)ISMB 150 X 8 X 0.75 (wt 15 kg/Rmt)b) Angle 50 x 50 x 6m(wt 4.50 kg/Rmt)c) C section 4 x 2 m (wt 7.14 kg/Rmt) 65 Electictic Connections (Bulb Tube Swich) 66 Sub Work No.7 : Trial Run.Commisioning running and maintaining the scheme to quantites, rated capacity, including manning necessary personnelsuchasoperator,valveman,etc.asper requirementsoftheschemeandwhoshouldalso administer chemical dose for a period of 1 month for individual scheme and 3 months for regional scheme, togetherwithtrainingofpersonnelsparedbyMJP/ LocalBodyandhandingovertheschemetoLocal Body after completion of the above period as directed byEngineer-in-charge.