}

Tender For Supply, Installation, Testing And Commissioning Of Panel Board At Old Library Building, calicut-Kerala

Boards / Undertakings / PSU has published Tender For Supply, Installation, Testing And Commissioning Of Panel Board At Old Library Building. Submission Date for this Tender is 25-10-2024. Couplers Tenders in calicut Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

45576939
Tender For Supply, Installation, Testing And Commissioning Of Panel Board At Old Library Building
Open Tender
Indian
Kerala
Calicut
25-10-2024

Tender Documents

Tender Details

Tender For Supply, Installation, Testing And Commissioning Of Panel Board At Old Library Building; 1 WIRING IN STEEL & PVC CONDUIT 2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 3 Group C 4 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. 5 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 6 4 X 10 sq. mm + 2 X 6sq. mm earth wire 7 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 8 MCCB, MCB & DBS 9 Supplying and fixing following way,horizontal type three pole and neutral,sheetsteel,MOBdistributionboard, 415V,onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 10 4 way (4 + 12), Double door 11 Supplyingand fixingof following ways surface/ recessmounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MOB TPDB is normally used where 3 phase outlets are required.) 12 8 way (4 + 24), Double door 13 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. 14 Single pole 15 Double pole 16 Triple pole 17 Triple pole and neutral 18 Supplying and fixing followingrating, four pole, (threephase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existingMCBDB complete with connections, testing and commissioning etc. as required. 19 40A 20 63A 21 EARTHING 22 Providing and fixing 25 mm X 5 mm GI. strip on surface or in recess for connections etc. as required. 23 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 24 MV CABLE LAYING 25 Laying of one number PVCinsulated andPVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing DWC HDPE pipe as required. 26 Above 95 sq. mm and upto 185 sq. mm 27 Laying of one number PVC insulated andPVC sheathed / XLPE powercableof1.1KVgradeoffollowingsizeintheexisting masonry open duct as required. 28 Above 35 sq. mm and upto 95 sq. mm 29 Above 95 sq. mm and upto 185 sq. mm 30 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 31 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 32 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mmMS flat clamp) 33 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. 34 MV CABLE JOINTING & END TERMINATION 35 Supplyingandmakingendterminationwithbrass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. 36 3.5 C X 50 sq. mm (35mm) 37 3.5 CX 70 sq. mm (38mm) 38 3.5 C X 120 sq. mm (45mm) 39 3.5 C X 185 sq. mm (57mm) 40 MISC. CIVIL ITEMS 41 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 42 120 mm dia (00-120 mm & ID-103 mm nominal) 43 LIGHTING 44 LED TUBELIGHT 45 Supply and fixing of box type tube fittings (Batten & T8 LED Tube), complete with side holders and 18/20 watt 4 feet T8 LED tube, Including suitable GI clamp for fixing at an angle of 45 degree. etc, as required.(T8 LED-Bajaj BLRB 18W CW LED, Batten- Bajaj BLRB-DB 118 I, or compatible). 46 ARMOURED CABLE XLPE 47 Supply of 1.1 kV grade 3.5C x 70 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable as required. 48 Supply of 1.1 kV grade 3.5C x 185 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required. 49 HORIZONTAL DB 50 Supplying and fixing 4 way, single pole and neutral Double door, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 51 MCB 52 Supplying and fixing 63 amps rating, four pole, 415 Volts, C curve miniature circuit breaker suitable for inductive loadin the existing MCB DB complete with connectons, testing and commissioning etc as required. 53 STICKERING ON DB/PANEL 54 Supplying and fixing the identification details of cables and Distribution boards details with vinyl stickers on existing panel board & DB etc. as required 55 CABLE TAG 56 Supplying and fixing cable details tags using Aluminium sheet ofsize 10 cm X 3 cm X 2 mm or nearest size on the existing cable. 57 CAD DRAWINGS 58 Submission of as fitted drawing in Autocad and pdf format along with physical copy of the same in the format and standard to get the approval fromelectrical inspectorate.(along with seal,signature and license details) etc as required. 59 PANEL BOARD 60 Fabrication, supply, conveyance, installation testing and commissioningfloor /wall mounting, dust and vermin proof, cubicle type panel boardmade from 75x40x6 size C channel base frame comprising of the following components/ devices ,complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assemblyusing 2 mm POWDER COATED CRCA sheet as per approved design and requirement 2mm for frame , with frontaccess facility, bus bar chambers with copper bus , hinged doors for all switch gear compartmentsandearthing the doors usingbraided copper conductor and providingindication lamps, digital type Multi function meter suitable CTs,danger notice board, LED indicator, feeder compartment lock, terminal block, PVC trunking, slotted channel, suitable connector, termination lug, copper wire if required, meter viewing glass if required etc.The board should bepowder coating the assembly after subjecting to 7 tank processas required. 2 Nos Copper earth bar of size 25 mm x 3 mm at the rear . earth stud. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. Insulated copper bus bar for phase and Neutral adequate amperesize of Incomer Switch , out going switches. The panel Board should be fitted on the base frame for panel board using channels of class designation 75 including cutting,welding, drilling holes,painting two coats of synthatic enamel paint over a coat of zinc chromate paint botling the frame to the panel and to the furnished floor using required bolts and nuts making good the dameges colour washing and including providing and fixing the following switch gears etc as required.The charges for all control wiring, loading and unloading, testing and commissioning are included. The cable entry may be bottom or top as per direction of Engineer in charge, The Panel shall be Fabricated as perElectrical Inspectorate, KSEB, CPRI & other relevent codes and standards. 61 Incoming: (Approved make) - 400A ,50kA,415V,4 Pole MCCB Microprocessor release,ROM ,spreaders at the incoming and outgoing sides etc.complete. The MCCB shall haveshunt trip coil-1No. Outgoing (Approved make) - 200A 4P 25kA MCCB with Rotary Handle, Spreders -1 nos160A 4P 25kA MCCB with Rotary Handle, Spreders -2 nos125A 4P 25kA MCCB with Rotary Handle, Spreders -1 nos100A 4P 18kA MCCB with Rotary Handle, Spreders -5 nos63A 4P 18kA MCCB with Rotary Handle, Spreders -3 nosSpare Chamber to fix a MCCB minimum size of 100 A - 2 nosMFM meter-1nos ,6A SP MCB -3 nos, LED indication -3 nosResin cast metering CT (400/ 5 A ) 15 VA of accuracy class 0.1- 3.00 NosEarth Leackage Relay with CBCT-1 No. 62 GI PLATE EARTHING 63 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement, watering pipe of 2.7 metre long and with suitable amount (60kg) of earthing compound (EXCEL compound or equivalent) etc. as required. 64 EXHAUST FAN 65 Supplying and fixing of heavy duty 450mm sweep exhaust fan with front guard working on 240 volts,50Hz AC supply, on existing exhaust fan provision, making good the daamages,giving connection with 3 core flexible copper wire, etc as requiredspeed>1400rpm including connection etc. as required. Make:Almonard / Havells or Equivalent 66 PANEL BOARD REMOVAL 67 Charges for removing the existing Panel board, (All, UG cable, wires & PVC conduits) making good the damages of the wall / floor including painting other accessories without any damage and conveyance of the materials / Panel board to the godown etc, as required. 68 Charges for removing the existing DB, (All, cable wires & PVC conduits) and refixing the same DB on wall including cable termination, making good the damages of the wall / floor including painting other accessories without any damage etc as required.

Key Value

Document Fees
Refer document
EMD
INR 38000.0 /-
Tender Value
INR 19 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Notice 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Click here to download tender document Tender Document 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail